메뉴 건너뛰기




Volumn 123, Issue 9, 2005, Pages 1226-1230

Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CONTRAST SENSITIVITY; CONTROLLED STUDY; EVALUATION; FEMALE; HUMAN; LENS IMPLANT; LENS IMPLANTATION; MAJOR CLINICAL STUDY; MALE; PATIENT SELECTION; PRIORITY JOURNAL; PSEUDOPHAKIA; PUPIL; REFRACTIVE SURGERY; VISUAL ACUITY; AGED; CATARACT EXTRACTION; CORNEA; FOREIGN BODY; KERATOMETRY; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; PROSTHESIS; PROSTHESIS FAILURE; REFRACTION ERROR;

EID: 24944471397     PISSN: 00039950     EISSN: None     Source Type: Journal    
DOI: 10.1001/archopht.123.9.1226     Document Type: Article
Times cited : (84)

References (12)
  • 1
    • 0036859728 scopus 로고    scopus 로고
    • Prospective randomized trial of an anterior surface modified prolate intraocular lens
    • Packer M, Fine IH, Hoffman RS, Piers PA. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg. 2002;18:692-696.
    • (2002) J Refract Surg , vol.18 , pp. 692-696
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3    Piers, P.A.4
  • 2
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: Clinical comparative study
    • Mester U, Dillinger P, Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg. 2003;29:652-660.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 3
    • 0141643152 scopus 로고    scopus 로고
    • Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses: Prospective evaluation
    • Kershner RM. Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses: prospective evaluation. J Cataract Refract Surg. 2003;29:1684-1694.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1684-1694
    • Kershner, R.M.1
  • 5
    • 0037325668 scopus 로고    scopus 로고
    • Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation
    • Bueeler M, Mrochen M, Seiler T. Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation. J Cataract Refract Surg. 2003;29:257-263.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 257-263
    • Bueeler, M.1    Mrochen, M.2    Seiler, T.3
  • 6
    • 0042397961 scopus 로고    scopus 로고
    • Standards for reporting the optical aberrations of eyes
    • MacRae SM, Krueger RR, Applegate RA, eds. Thorofare, NJ: Slack Inc
    • Thibos LN, Applegate RA, Schwiegerling JT, et al. Standards for reporting the optical aberrations of eyes. In: MacRae SM, Krueger RR, Applegate RA, eds. Customized Corneal Ablation, the Quest for Supervision. Thorofare, NJ: Slack Inc;2001:348-361.
    • (2001) Customized Corneal Ablation, the Quest for Supervision , pp. 348-361
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3
  • 7
    • 0141458945 scopus 로고    scopus 로고
    • A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    • Wallin TR, Hinckley M, Nilson C, Olson RJ. A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses.Am J Ophthalmol. 2003;136:614-619.
    • (2003) Am J Ophthalmol , vol.136 , pp. 614-619
    • Wallin, T.R.1    Hinckley, M.2    Nilson, C.3    Olson, R.J.4
  • 8
    • 0033510540 scopus 로고    scopus 로고
    • Update on fixation of rigid and foldable posterior chamber intraocular lenses, part I: Elimination of fixation-induced decentration to achieve precise optical correction and visual rehabilitation
    • Ram J, Apple DJ, Peng Q, et al. Update on fixation of rigid and foldable posterior chamber intraocular lenses, part I: Elimination of fixation-induced decentration to achieve precise optical correction and visual rehabilitation. Ophthalmology. 1999;106:883-890.
    • (1999) Ophthalmology , vol.106 , pp. 883-890
    • Ram, J.1    Apple, D.J.2    Peng, Q.3
  • 9
    • 0342748697 scopus 로고    scopus 로고
    • Decentration and tilt: Silicone multifocal versus acrylic soft intraocular lenses
    • Jung CK, Chung SK, Baek NH. Decentration and tilt: silicone multifocal versus acrylic soft intraocular lenses. J Cataract Refract Surg. 2000;26:582-585.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 582-585
    • Jung, C.K.1    Chung, S.K.2    Baek, N.H.3
  • 10
    • 0033987985 scopus 로고    scopus 로고
    • Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism
    • Seiler T, Kaemmerer M, Mierdel P, Krinke HE. Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism. Arch Ophthalmol. 2000;118:17-21.
    • (2000) Arch Ophthalmol , vol.118 , pp. 17-21
    • Seiler, T.1    Kaemmerer, M.2    Mierdel, P.3    Krinke, H.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.