메뉴 건너뛰기




Volumn 268, Issue 3-4, 2010, Pages 481-487

Wear patterns of, and wear volume formulae for, hemispherical acetabular cup liners

Author keywords

Surface topography; Total hip replacement; UHMWPE wear; Wear formulae; Wear pattern; Wear volume

Indexed keywords

ARTHROPLASTY; CALCULATIONS; HIP PROSTHESES; INTEGRAL EQUATIONS; SURFACE TOPOGRAPHY;

EID: 73149114162     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2009.09.007     Document Type: Article
Times cited : (13)

References (41)
  • 1
    • 0029007450 scopus 로고
    • Cemented revision for aseptic acetabular loosening: a review of 387 hips
    • Raut V.V., Siney P.D., and Wroblewski B.M. Cemented revision for aseptic acetabular loosening: a review of 387 hips. J. Bone Joint Surg. Br. 77 (1995) 357-361
    • (1995) J. Bone Joint Surg. Br. , vol.77 , pp. 357-361
    • Raut, V.V.1    Siney, P.D.2    Wroblewski, B.M.3
  • 2
    • 0025165926 scopus 로고
    • Total hip arthroplastic patients younger than 45 years. A nine to ten-year follow-up study
    • Dorr L.D., Luckett M., and Conaty J.P. Total hip arthroplastic patients younger than 45 years. A nine to ten-year follow-up study. Clin. Orthop. Relat. Res. 260 (1990) 215-219
    • (1990) Clin. Orthop. Relat. Res. , vol.260 , pp. 215-219
    • Dorr, L.D.1    Luckett, M.2    Conaty, J.P.3
  • 8
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • Dumbleton J.H., Manley M.T., and Edidin A.A. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J. Arthroplasty 17 5 (2002) 649-661
    • (2002) J. Arthroplasty , vol.17 , Issue.5 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.A.3
  • 9
    • 0033029624 scopus 로고    scopus 로고
    • Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    • Sochart D.H. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin. Orthop. Relat. Res. 363 (1999) 135-150
    • (1999) Clin. Orthop. Relat. Res. , vol.363 , pp. 135-150
    • Sochart, D.H.1
  • 10
    • 33846558459 scopus 로고    scopus 로고
    • The potential role of phagocytic capacity in the osteolytic process induced by polyethylene wear particles
    • Fang H.W., Yang C.B., Chang C.H., Huang C.H., Liu H.L., and Fang S.B. The potential role of phagocytic capacity in the osteolytic process induced by polyethylene wear particles. J. Int. Med. Res. 34 (2006) 655-664
    • (2006) J. Int. Med. Res. , vol.34 , pp. 655-664
    • Fang, H.W.1    Yang, C.B.2    Chang, C.H.3    Huang, C.H.4    Liu, H.L.5    Fang, S.B.6
  • 11
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement
    • Ingham E., and Fisher J. Biological reactions to wear debris in total joint replacement. Proc. Inst. Mech. Eng. H 214 (2000) 21-37
    • (2000) Proc. Inst. Mech. Eng. H , vol.214 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 12
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J., Ilstrup D., and Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone Joint Surg. Am. 72 (1990) 18-28
    • (1990) J. Bone Joint Surg. Am. , vol.72 , pp. 18-28
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 14
    • 0029085995 scopus 로고
    • Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry
    • Ilchmann T., Mjoberg B., and Wingstrand H. Measurement accuracy in acetabular cup wear. Three retrospective methods compared with Roentgen stereophotogrammetry. J. Arthroplasty 10 (1995) 636-642
    • (1995) J. Arthroplasty , vol.10 , pp. 636-642
    • Ilchmann, T.1    Mjoberg, B.2    Wingstrand, H.3
  • 15
    • 0034089675 scopus 로고    scopus 로고
    • The effect of joint loading on acetabular wear measurement in total hip arthroplasty
    • Martell J.M., Leopold S.S., and Liu X. The effect of joint loading on acetabular wear measurement in total hip arthroplasty. J. Arthroplasty 15 (2000) 512-518
    • (2000) J. Arthroplasty , vol.15 , pp. 512-518
    • Martell, J.M.1    Leopold, S.S.2    Liu, X.3
  • 16
    • 0036208393 scopus 로고    scopus 로고
    • Measurement of polyethylene wear: a new three-dimensional methodology
    • Chen J.H., and Wu J.S.S. Measurement of polyethylene wear: a new three-dimensional methodology. Comput. Methods Prog. Biomed. 68 2 (2002) 117-127
    • (2002) Comput. Methods Prog. Biomed. , vol.68 , Issue.2 , pp. 117-127
    • Chen, J.H.1    Wu, J.S.S.2
  • 17
    • 0014457406 scopus 로고
    • The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip
    • Charnley J., Kamangar A., and Longfield M.D. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med. Biol. Eng. 7 (1969) 31-39
    • (1969) Med. Biol. Eng. , vol.7 , pp. 31-39
    • Charnley, J.1    Kamangar, A.2    Longfield, M.D.3
  • 20
    • 0031616211 scopus 로고    scopus 로고
    • The estimation of acetabular cup wear volume from two-dimensional measurements: a comprehensive analysis
    • Derbyshire B. The estimation of acetabular cup wear volume from two-dimensional measurements: a comprehensive analysis. Proc. Inst. Mech. Eng. H 212 (1998) 281-291
    • (1998) Proc. Inst. Mech. Eng. H , vol.212 , pp. 281-291
    • Derbyshire, B.1
  • 21
    • 0346243559 scopus 로고    scopus 로고
    • Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data
    • Košak R., Antolic V., Pavlovcic V., Kralj-Iglic V., Milošev I., Vidmar G., and Iglic A. Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data. Skeletal Radiol. 32 12 (2003) 679-686
    • (2003) Skeletal Radiol. , vol.32 , Issue.12 , pp. 679-686
    • Košak, R.1    Antolic, V.2    Pavlovcic, V.3    Kralj-Iglic, V.4    Milošev, I.5    Vidmar, G.6    Iglic, A.7
  • 22
    • 0042476688 scopus 로고    scopus 로고
    • Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis
    • Mizoue T., Yamamoto K., Masaoka T., Imakiire A., Akagi M., and Clarke I.C. Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis. J. Orthop. Sci. 8 4 (2003) 491-499
    • (2003) J. Orthop. Sci. , vol.8 , Issue.4 , pp. 491-499
    • Mizoue, T.1    Yamamoto, K.2    Masaoka, T.3    Imakiire, A.4    Akagi, M.5    Clarke, I.C.6
  • 23
    • 39849083930 scopus 로고    scopus 로고
    • Estimation of the wear volume after total hip replacement. A simple access to geometrical concepts
    • Ilchmann T., Reimoldb M., and Müller-Schauenburg W. Estimation of the wear volume after total hip replacement. A simple access to geometrical concepts. Med. Eng. Phys. 30 3 (2008) 373-379
    • (2008) Med. Eng. Phys. , vol.30 , Issue.3 , pp. 373-379
    • Ilchmann, T.1    Reimoldb, M.2    Müller-Schauenburg, W.3
  • 24
    • 0012962157 scopus 로고
    • Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components
    • Hashimoto Y., Bauer T.W., Jiang M., and Stulberg B.N. Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components. Trans. Orthop. Res. Soc. 20 (1995) 116
    • (1995) Trans. Orthop. Res. Soc. , vol.20 , pp. 116
    • Hashimoto, Y.1    Bauer, T.W.2    Jiang, M.3    Stulberg, B.N.4
  • 25
    • 0028836831 scopus 로고
    • The origin of submicron polyethylene wear debris in total hip arthroplasty
    • Mckellop H.A., Campbell P., and Park S.H. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin. Orthop. Relat. Res. 311 (1995) 3-20
    • (1995) Clin. Orthop. Relat. Res. , vol.311 , pp. 3-20
    • Mckellop, H.A.1    Campbell, P.2    Park, S.H.3
  • 30
    • 0035063689 scopus 로고    scopus 로고
    • In vivo" determination of hip joint separation and the forces generated due to impact loading conditions
    • Dennis D.A., Komistek R.D., Northcut E.J., Ochoa J.A., and Ritchei A. In vivo" determination of hip joint separation and the forces generated due to impact loading conditions. J. Biomech. 34 5 (2001) 623-629
    • (2001) J. Biomech. , vol.34 , Issue.5 , pp. 623-629
    • Dennis, D.A.1    Komistek, R.D.2    Northcut, E.J.3    Ochoa, J.A.4    Ritchei, A.5
  • 31
    • 0035680629 scopus 로고    scopus 로고
    • Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
    • Stewart T., Tipper J., Streicher R., Ingham E., and Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J. Mater. Sci. Mater. Med. 12 10-12 (2001) 1053-1056
    • (2001) J. Mater. Sci. Mater. Med. , vol.12 , Issue.10-12 , pp. 1053-1056
    • Stewart, T.1    Tipper, J.2    Streicher, R.3    Ingham, E.4    Fisher, J.5
  • 32
    • 73149112924 scopus 로고    scopus 로고
    • Analysis of micro-separation and contact mechanics between the femoral head and the acetabular cup in artificial hip joint replacements
    • Besong A., Jin Z.M., and Fisher J. Analysis of micro-separation and contact mechanics between the femoral head and the acetabular cup in artificial hip joint replacements. Proceedings of the 47th Annual Meeting of the Orthopaedic Research Society (2000) 1051
    • (2000) Proceedings of the 47th Annual Meeting of the Orthopaedic Research Society , pp. 1051
    • Besong, A.1    Jin, Z.M.2    Fisher, J.3
  • 33
    • 49649100846 scopus 로고    scopus 로고
    • Analysis of wear and oxidation on retrieved bipolar polyethylene liner
    • Hara K., Kaku N., Tsumura H., and Torisu T. Analysis of wear and oxidation on retrieved bipolar polyethylene liner. J. Orthop. Sci. 13 (2008) 366-370
    • (2008) J. Orthop. Sci. , vol.13 , pp. 366-370
    • Hara, K.1    Kaku, N.2    Tsumura, H.3    Torisu, T.4
  • 36
    • 0037086743 scopus 로고    scopus 로고
    • Effects of the sterilization method on the wear of UHMWPE acetabular cups tested in a hip simulator
    • Affatato S., Bordini B., Fagnano C., Taddei P., Tinti A., and Toni A. Effects of the sterilization method on the wear of UHMWPE acetabular cups tested in a hip simulator. Biomaterials 23 (2002) 1439-1446
    • (2002) Biomaterials , vol.23 , pp. 1439-1446
    • Affatato, S.1    Bordini, B.2    Fagnano, C.3    Taddei, P.4    Tinti, A.5    Toni, A.6
  • 38
    • 39849107086 scopus 로고    scopus 로고
    • The effects of irradiation and EtO-treatment on ultrahigh molecular weight polyethylene acetabular cups following accelerated aging: degradation of mechanical properties and morphology changes during hip simulator tests
    • Taddei P., Affatato S., Rocchi M., Fagnano C., and Viceconti M. The effects of irradiation and EtO-treatment on ultrahigh molecular weight polyethylene acetabular cups following accelerated aging: degradation of mechanical properties and morphology changes during hip simulator tests. J. Mol. Struct. 875 1-3 (2008) 254-263
    • (2008) J. Mol. Struct. , vol.875 , Issue.1-3 , pp. 254-263
    • Taddei, P.1    Affatato, S.2    Rocchi, M.3    Fagnano, C.4    Viceconti, M.5
  • 39
    • 33645734626 scopus 로고    scopus 로고
    • Influence of polyethylene creep behavior on wear in total hip arthroplasty
    • Penmetsa J.R., Laz P.J., Petrella A.J., and Rullkoetter P.J. Influence of polyethylene creep behavior on wear in total hip arthroplasty. J. Orthop. Res. 24 3 (2006) 422-427
    • (2006) J. Orthop. Res. , vol.24 , Issue.3 , pp. 422-427
    • Penmetsa, J.R.1    Laz, P.J.2    Petrella, A.J.3    Rullkoetter, P.J.4
  • 40
    • 57149083893 scopus 로고    scopus 로고
    • Dioscorea improves the morphometric and mechanical properties of bone in ovariectomised rat
    • Chen J.H., Wu J.S.S., Lin H.C., Wu S.L., Wang W.F., Huang S.K., and Ho Y.J. Dioscorea improves the morphometric and mechanical properties of bone in ovariectomised rat. J. Sci. Food Agric. 88 15 (2008) 2700-2706
    • (2008) J. Sci. Food Agric. , vol.88 , Issue.15 , pp. 2700-2706
    • Chen, J.H.1    Wu, J.S.S.2    Lin, H.C.3    Wu, S.L.4    Wang, W.F.5    Huang, S.K.6    Ho, Y.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.