메뉴 건너뛰기




Volumn 20, Issue 2, 2005, Pages 239-243

The measurement of creep in ultrahigh molecular weight polyethylene: A comparison of conventional versus highly cross-linked polyethylene

Author keywords

Arthroplasty; Creep; Cross linking; Hip; Polyethylene

Indexed keywords

ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE;

EID: 14844312072     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2004.08.008     Document Type: Article
Times cited : (38)

References (16)
  • 1
    • 0001379590 scopus 로고    scopus 로고
    • Clinical experience with gamma irradiation-crosslinked polyethylene
    • C.J. Grobbelaar, F.A. Weber, and A. Spirakis Clinical experience with gamma irradiation-crosslinked polyethylene S. Afr. Bone Joint Surg. XI 1999 140
    • (1999) S. Afr. Bone Joint Surg. , vol.11 , pp. 140
    • Grobbelaar, C.J.1    Weber, F.A.2    Spirakis, A.3
  • 2
    • 0035217958 scopus 로고    scopus 로고
    • Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene
    • H. Oonishi, J.C. Clarke, and S. Masuda Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene J. Arthroplasty 16 Suppl. 8 2001 129
    • (2001) J. Arthroplasty , vol.16 , Issue.8 SUPPL. , pp. 129
    • Oonishi, H.1    Clarke, J.C.2    Masuda, S.3
  • 3
    • 0035078816 scopus 로고    scopus 로고
    • Gamma-irradiated cross-linked polyethylene in total hip replacement-analysis of retrieved sockets after long-term implantation
    • H. Oonishi, Y. Kadoyz, and S. Masuda Gamma-irradiated cross-linked polyethylene in total hip replacement-analysis of retrieved sockets after long-term implantation J. Biomed. Mater. Res. 58 2001 167
    • (2001) J. Biomed. Mater. Res. , vol.58 , pp. 167
    • Oonishi, H.1    Kadoyz, Y.2    Masuda, S.3
  • 4
    • 0033637708 scopus 로고    scopus 로고
    • Effect of sterilization method and other modifications of the wear resistance of acetabular cups made of ultrahigh molecular weight polyethylene: A hip simulator study
    • H. McKellop, F.W. Shen, and B. Lu Effect of sterilization method and other modifications of the wear resistance of acetabular cups made of ultrahigh molecular weight polyethylene: a hip simulator study J. Bone Joint Surg. Am. 82 2000 1788
    • (2000) J. Bone Joint Surg. Am. , vol.82 , pp. 1788
    • McKellop, H.1    Shen, F.W.2    Lu, B.3
  • 5
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
    • O.K. Muratoglu, C.R. Bragdon, and D.O. O'Connor A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award J. Arthroplasty 16 2001 49
    • (2001) J. Arthroplasty , vol.16 , pp. 49
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3
  • 6
    • 0033869250 scopus 로고    scopus 로고
    • Characterization of long-term femoral head penetration rates. Association with and prediction of osteolysis
    • J.E. Dowd, C.J. Sychterz, and A.M. Young Characterization of long-term femoral head penetration rates. Association with and prediction of osteolysis J. Bone Joint Surg. Am. 82 2000 1102
    • (2000) J. Bone Joint Surg. Am. , vol.82 , pp. 1102
    • Dowd, J.E.1    Sychterz, C.J.2    Young, A.M.3
  • 7
    • 0033835923 scopus 로고    scopus 로고
    • Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads
    • C.J. Sychterz, C.A. Engh Jr., and A.M. Young Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads J. Bone Joint Surg. Br. 82 2000 948
    • (2000) J. Bone Joint Surg. Br. , vol.82 , pp. 948
    • Sychterz, C.J.1    Engh Jr., C.A.2    Young, A.M.3
  • 8
    • 0034880751 scopus 로고    scopus 로고
    • The effect of activity levels of total hip arthroplasty patients on socket penetration
    • A.A.J. Goldsmith, D. Dowson, and B.M. Wroblewski The effect of activity levels of total hip arthroplasty patients on socket penetration J. Arthroplasty 16 2001 620
    • (2001) J. Arthroplasty , vol.16 , pp. 620
    • Goldsmith, A.A.J.1    Dowson, D.2    Wroblewski, B.M.3
  • 9
    • 0024040573 scopus 로고
    • Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints
    • D. Dowson, and B. Jobbins Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints Eng. Med. 17 1988 111
    • (1988) Eng. Med. , vol.17 , pp. 111
    • Dowson, D.1    Jobbins, B.2
  • 10
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross linked polyethylene cups
    • B.M. Wroblewski, P.D. Siney, and D. Dowson Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross linked polyethylene cups J. Bone Joint Surg. Br. 78 1996 280
    • (1996) J. Bone Joint Surg. Br. , vol.78 , pp. 280
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3
  • 11
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report
    • B.M. Wroblewski, P.D. Siney, and P.A. Fleming Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report J. Bone Joint Surg. Br. 81 1999 54
    • (1999) J. Bone Joint Surg. Br. , vol.81 , pp. 54
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 13
    • 0013955509 scopus 로고
    • Biomechanics. The biomechanics of the hip joint and its clinical relevance
    • J. Paul Biomechanics. The biomechanics of the hip joint and its clinical relevance Proc. R. Soc. Med. 59 1966 943
    • (1966) Proc. R. Soc. Med. , vol.59 , pp. 943
    • Paul, J.1
  • 16
    • 0036796360 scopus 로고    scopus 로고
    • In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
    • R.D. Komistek, D.A. Dennis, and J.A. Ochoa In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty J. Bone Joint Surg. Am. 84 2002 1205
    • (2002) J. Bone Joint Surg. Am. , vol.84 , pp. 1205
    • Komistek, R.D.1    Dennis, D.A.2    Ochoa, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.