Comparison of the IOPen® and iCare® rebound tonometers with the Goldmann tonometer in a normal population

Author keywords

Applanation tonometry; ICare ; Impact tonometry; Induction; Intraocular pressure; IOPen ; Rebound tonometer

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; FEMALE; GOLDMANN APPLANATION TONOMETER; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; NORMAL HUMAN; OCULOPLETHYSMOGRAPHY; PRIORITY JOURNAL; REBOUND TONOMETER; TONOMETER; INSTRUMENTATION; INTRAOCULAR HYPERTENSION; MIDDLE AGED; NONPARAMETRIC TEST; STANDARD;

EID: 72449188737     PISSN: 02755408     EISSN: 14751313     Source Type: Journal    
DOI: 10.1111/j.1475-1313.2009.00697.x     Document Type: Article
Times cited : (24)

References (17)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J. M. Altman, D. G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1, 307 310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 38149099312 scopus 로고    scopus 로고
    • Accuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication
    • Diaz, A., Yebra-Pimentel, E., Resua, C. G., Gilino, J. Giraldez, M. J. (2008) Accuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication. Ophthalmic Physiol. Opt. 28, 29 34.
    • (2008) Ophthalmic Physiol. Opt. , vol.28 , pp. 29-34
    • Diaz, A.1    Yebra-Pimentel, E.2    Resua, C.G.3    Gilino, J.4    Giraldez, M.J.5
  • 5
    • 33644629030 scopus 로고    scopus 로고
    • Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes
    • Garcia-Resua, C., Gonzalez-Meijome, J. M., Gilino, J. Yebra-Pimentel, E. (2006) Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes. Optom. Vis. Sci. 83, 102 107.
    • (2006) Optom. Vis. Sci. , vol.83 , pp. 102-107
    • Garcia-Resua, C.1    Gonzalez-Meijome, J.M.2    Gilino, J.3    Yebra-Pimentel, E.4
  • 9
    • 58149123724 scopus 로고    scopus 로고
    • Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry
    • Jorge, J. M., Gonzalez-Meijome, J. M., Queiros, A., Fernandes, P. Parafita, M. A. (2008) Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometry. J. Glaucoma 17, 442 448.
    • (2008) J. Glaucoma , vol.17 , pp. 442-448
    • Jorge, J.M.1    Gonzalez-Meijome, J.M.2    Queiros, A.3    Fernandes, P.4    Parafita, M.A.5
  • 10
    • 0034115306 scopus 로고    scopus 로고
    • A new induction-based impact method for measuring intraocular pressure
    • Kontiola, A. I. (2000) A new induction-based impact method for measuring intraocular pressure. Acta Ophthalmol. Scand. 78, 142 145.
    • (2000) Acta Ophthalmol. Scand. , vol.78 , pp. 142-145
    • Kontiola, A.I.1
  • 11
    • 0035704347 scopus 로고    scopus 로고
    • The induction/impact tonometer: A new instrument to measure intraocular pressure in the rat
    • Kontiola, A. I., Goldblum, D., Mittag, T. Danias, J. (2001) The induction/impact tonometer: a new instrument to measure intraocular pressure in the rat. Exp. Eye Res. 73, 781 785.
    • (2001) Exp. Eye Res. , vol.73 , pp. 781-785
    • Kontiola, A.I.1    Goldblum, D.2    Mittag, T.3    Danias, J.4
  • 14
    • 45349104331 scopus 로고    scopus 로고
    • Comparison of rebound and applanation tonometry in the management of patients treated for glaucoma or ocular hypertension
    • Rehnman, J. B. Martin, L. (2008) Comparison of rebound and applanation tonometry in the management of patients treated for glaucoma or ocular hypertension. Ophthalmic Physiol. Opt. 28, 382 386.
    • (2008) Ophthalmic Physiol. Opt. , vol.28 , pp. 382-386
    • Rehnman, J.B.1    Martin, L.2
  • 15
    • 0018903467 scopus 로고
    • The non-contact tonometer. Its value and limitation
    • Shields, M. B. (1980) The non-contact tonometer. Its value and limitation. Surv. Ophthalmol. 24, 211 219.
    • (1980) Surv. Ophthalmol. , vol.24 , pp. 211-219
    • Shields, M.B.1
  • 16
    • 0016517107 scopus 로고
    • Clinical tonometric measurements comparing three non-contact tonometers
    • Walby, M. A., Augsburger, A. Polasky, M. (1975) Clinical tonometric measurements comparing three non-contact tonometers. Am. J. Optom. Physiol. Opt. 52, 414 418.
    • (1975) Am. J. Optom. Physiol. Opt. , vol.52 , pp. 414-418
    • Walby, M.A.1    Augsburger, A.2    Polasky, M.3
  • 17
    • 0017598952 scopus 로고
    • A clinical evaluation of the non-contact tonometer
    • Wittenberg, S. (1977) A clinical evaluation of the non-contact tonometer. J. Am. Optom. Assoc. 48, 196 207.
    • (1977) J. Am. Optom. Assoc. , vol.48 , pp. 196-207
    • Wittenberg, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.