메뉴 건너뛰기




Volumn 17, Issue 6, 2009, Pages 543-550

Photoconductor-based (direct) large-area x-ray imagers

Author keywords

A Se; A Si TFT arrays; CdTe; CZT; Direct x ray imaging; Indirect x ray imaging; Lead iodide; Mercuric iodide; Organic semiconductors; X ray imagers

Indexed keywords

A-SI TFT; CDTE; DIRECT X-RAY; LEAD IODIDE; MERCURIC IODIDE; ORGANIC SEMICONDUCTOR; X-RAY IMAGERS; XRAY IMAGING;

EID: 72149114072     PISSN: 10710922     EISSN: None     Source Type: Journal    
DOI: 10.1889/JSID17.6.543     Document Type: Article
Times cited : (19)

References (24)
  • 3
    • 0033739938 scopus 로고    scopus 로고
    • Direct selenium x-ray detector for fluoroscopy, R&F, and radiography
    • M. Choquette et al., "Direct selenium x-ray detector for fluoroscopy, R&F, and radiography," Medical Imaging 2000: Physics of Medical Imaging 3977, 128-136 (2000).
    • (2000) Medical Imaging 2000: Physics of Medical Imaging , vol.3977 , pp. 128-136
    • Choquette, M.1
  • 4
    • 33847645786 scopus 로고    scopus 로고
    • A comparison of the performance of digital mammography systems
    • Monnin et al., "A comparison of the performance of digital mammography systems," Med. Phys. 34(3), 906-914 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.3 , pp. 906-914
    • Monnin1
  • 5
    • 3042544818 scopus 로고    scopus 로고
    • Systematic development of input-quantum-limited fluoroscopic imagers based on active-matrix flat-panel technology
    • L. E. Antonuk et al., "Systematic development of input-quantum-limited fluoroscopic imagers based on active-matrix flat-panel technology," Medical Imaging 2004: Physics of Medical Imaging 5368, 127-138 (2004).
    • (2004) Medical Imaging 2004: Physics of Medical Imaging , vol.5368 , pp. 127-138
    • Antonuk, L.E.1
  • 6
    • 15944403143 scopus 로고    scopus 로고
    • New developments in full-field radiography detectors: Direct conversion selenium detector with avalanche gain layer
    • D.L. Lee et al., "New developments in full-field radiography detectors: Direct conversion selenium detector with avalanche gain layer," Penetrating Radiation Systems and Applications VI 5541, 126-132 (2004).
    • (2004) Penetrating Radiation Systems and Applications VI , vol.5541 , pp. 126-132
    • Lee, D.L.1
  • 7
    • 0034874445 scopus 로고    scopus 로고
    • Alternate pixel architectures for large-area medical imaging
    • K.S. Karim et al., "Alternate pixel architectures for large-area medical imaging," Medical Imaging 2001: Physics of Medical Imaging 4320, 35-46 (2001).
    • (2001) Medical Imaging 2001: Physics of Medical Imaging , vol.4320 , pp. 35-46
    • Karim, K.S.1
  • 8
    • 14644406158 scopus 로고    scopus 로고
    • Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium
    • W. Zhao et al., "Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium," Med. Phys. 32(2), 488-500 (2005).
    • (2005) Med. Phys. , vol.32 , Issue.2 , pp. 488-500
    • Zhao, W.1
  • 9
    • 0033740082 scopus 로고    scopus 로고
    • Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy
    • S. Adachi et al., "Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy," Medical Imaging 2000: Physics of Medical Imaging 3977, 38-47 (2000).
    • (2000) Medical Imaging 2000: Physics of Medical Imaging , vol.3977 , pp. 38-47
    • Adachi, S.1
  • 10
    • 48149084457 scopus 로고    scopus 로고
    • Photon counting energy dispersive detector arrays for x-ray imaging
    • J. S. Iwanczyk et al., "Photon counting energy dispersive detector arrays for x-ray imaging," Nuclear Science Symposium Conference Record, 2741-2748 (2007).
    • (2007) Nuclear Science Symposium Conference Record , pp. 2741-2748
    • Iwanczyk, J.S.1
  • 11
    • 33750424074 scopus 로고    scopus 로고
    • Comparison of mercuric iodide and lead iodide x-ray detectors for x-ray imaging applications
    • G. Zentai et al., "Comparison of Mercuric Iodide and Lead Iodide X-Ray Detectors for X-Ray Imaging Applications," IEEE Trans. Nucl. Sci. 53(5), 2506-2512 (2006).
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.5 , pp. 2506-2512
    • Zentai, G.1
  • 12
    • 0032594454 scopus 로고    scopus 로고
    • X-ray imaging using lead iodide as a semiconductor detector
    • R. A. Street et al., "X-ray imaging using lead iodide as a semiconductor detector," Medical Imaging 1999: Physics of Medical Imaging 3659, 36-47 (1999).
    • (1999) Medical Imaging 1999: Physics of Medical Imaging , vol.3659 , pp. 36-47
    • Street, R.A.1
  • 13
    • 0016923735 scopus 로고
    • The behaviour of HgI2 nuclear detectors irradiated with high x-ray fluences
    • M. Schieber et al., "The behaviour of HgI2 nuclear detectors irradiated with high x-ray fluences," IEEE Trans. Nucl. Sci. 24(1), 148-153 (1977).
    • (1977) IEEE Trans. Nucl. Sci. , vol.24 , Issue.1 , pp. 148-153
    • Schieber, M.1
  • 14
    • 0035250924 scopus 로고    scopus 로고
    • Fabrication of mercuric iodide radiation detectors
    • L. van den Berg and R. Vigil, "Fabrication of mercuric iodide radiation detectors," Nucl. Inst. Method Phys. Res. A 458(1-2), 148-151 (2001).
    • (2001) Nucl. Inst. Method Phys. Res. A , vol.458 , Issue.1-2 , pp. 148-151
    • Van Den Berg, L.1    Vigil, R.2
  • 15
    • 72149130422 scopus 로고    scopus 로고
    • HgI2 polycrystalline films for digital X-ray imagers
    • J. S. Iwanczyk et al., "HgI2 polycrystalline films for digital X-ray imagers," Nucl. Sci. Symposium Conf. Record, 8/12 (2000).
    • (2000) Nucl. Sci. Symposium Conf. Record , vol.8-12
    • Iwanczyk, J.S.1
  • 17
    • 0346449309 scopus 로고    scopus 로고
    • Deposition of thick films of polycrystalline mercuric iodide x-ray detectors
    • H. Hermon et al., "Deposition of thick films of polycrystalline mercuric iodide x-ray detectors," Medical Imaging 2001: Physics of Medical Imaging 4320, 133-139 (2001).
    • (2001) Medical Imaging 2001: Physics of Medical Imaging , vol.4320 , pp. 133-139
    • Hermon, H.1
  • 18
    • 0033732134 scopus 로고    scopus 로고
    • Theoretical investigation of advanced design active matrix flat-panel imagers for mammography
    • K.-W. Jee et al., "Theoretical investigation of advanced design active matrix flat-panel imagers for mammography," Medical Imaging 2000: Physics of Medical Imaging 3977, 250-256 (2000).
    • (2000) Medical Imaging 2000: Physics of Medical Imaging , vol.3977 , pp. 250-256
    • Jee, K.-W.1
  • 20
    • 35148851198 scopus 로고    scopus 로고
    • Dark current and DQE improvements of mercuric iodide medical imagers
    • G. Zentai et al., "Dark current and DQE improvements of mercuric iodide medical imagers," Medical Imaging 2007: Physics of Medical Imaging 6510, 65100Q-65106 (2007).
    • (2007) Medical Imaging 2007: Physics of Medical Imaging , vol.6510
    • Zentai, G.1
  • 22
  • 23
    • 23844438943 scopus 로고    scopus 로고
    • Printed active-matrix TFT arrays for x-ray imaging (Invited Paper)
    • R. A. Street et al., "Printed active-matrix TFT arrays for x-ray imaging (Invited Paper)," Medical Imaging 2005: Physics of Medical Imaging 5745, 7-17 (2005).
    • (2005) Medical Imaging 2005: Physics of Medical Imaging , vol.5745 , pp. 7-17
    • Street, R.A.1
  • 24
    • 43149124996 scopus 로고    scopus 로고
    • Exploration of the potential performance of polycrystalline silicon-based active matrix flat-panel imagers incorporating active pixel sensor architectures
    • L. E. Antonuk et al., "Exploration of the potential performance of polycrystalline silicon-based active matrix flat-panel imagers incorporating active pixel sensor architectures," Medical Imaging 2008: Physics of Medical Imaging 6913, 69130I-69113 (2008).
    • (2008) Medical Imaging 2008: Physics of Medical Imaging , vol.6913 , pp. 6913-6916
    • Antonuk, L.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.