-
1
-
-
21144440478
-
Beam modeling and verification of a photon beam multisource model
-
Ahnesjö A, Weber L, Murman A, Saxner M, Thorslund I and Traneus E 2005 Beam modeling and verification of a photon beam multisource model Med. Phys. 32 1722-37
-
(2005)
Med. Phys.
, vol.32
, Issue.6
, pp. 1722-1737
-
-
Ahnesjö, A.1
Weber, L.2
Murman, A.3
Saxner, M.4
Thorslund, I.5
Traneus, E.6
-
2
-
-
33845220491
-
Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
-
Bragg C and Conway J 2006 Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning Radiother. Oncol. 81 315-23
-
(2006)
Radiother. Oncol.
, vol.81
, Issue.3
, pp. 315-323
-
-
Bragg, C.1
Conway, J.2
-
3
-
-
7244223251
-
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium
-
Carrasco P, Jornet N, Duch M A, Weber L, Ginjaume M, Eudaldo T, Jurado D, Ruiz A and Ribas M 2004 Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium Med. Phys. 31 2899-911
-
(2004)
Med. Phys.
, vol.31
, Issue.10
, pp. 2899-2911
-
-
Carrasco, P.1
Jornet, N.2
Duch, M.A.3
Weber, L.4
Ginjaume, M.5
Eudaldo, T.6
Jurado, D.7
Ruiz, A.8
Ribas, M.9
-
4
-
-
36649020653
-
Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
-
Chetty I J et al 2007 Report of the AAPM Task Group No. 105: issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning Med. Phys. 34 4818-53
-
(2007)
Med. Phys.
, vol.34
, Issue.12
, pp. 4818-4853
-
-
Chetty, I.J.1
-
5
-
-
1642495638
-
Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning
-
Cygler J E, Daskalov G M, Chan G H and Ding G X 2004 Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning Med. Phys. 31 142-53
-
(2004)
Med. Phys.
, vol.31
, Issue.1
, pp. 142-153
-
-
Cygler, J.E.1
Daskalov, G.M.2
Chan, G.H.3
Ding, G.X.4
-
6
-
-
16444386596
-
Clinical use of a commercial Monte Carlo treatment planning system for electron beams
-
Cygler J E, Lochrin C, Daskalov G M, Howard M, Zohr R, Esche B, Eapen L, Grimard L and Caudrelier J M 2005 Clinical use of a commercial Monte Carlo treatment planning system for electron beams Phys. Med. Biol. 50 1029-34
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.5
, pp. 1029-1034
-
-
Cygler, J.E.1
Lochrin, C.2
Daskalov, G.M.3
Howard, M.4
Zohr, R.5
Esche, B.6
Eapen, L.7
Grimard, L.8
Caudrelier, J.M.9
-
7
-
-
68849122593
-
Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements
-
Edimo P, Clermont C, Kwato M G and Vynckier S 2009 Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements Phys. Med. 25 111-21
-
(2009)
Phys. Med.
, vol.25
, pp. 111-121
-
-
Edimo, P.1
Clermont, C.2
Kwato, M.G.3
Vynckier, S.4
-
8
-
-
0032772588
-
Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
-
Fippel M 1999 Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm Med. Phys. 26 1466-75
-
(1999)
Med. Phys.
, vol.26
, Issue.8
, pp. 1466-1475
-
-
Fippel, M.1
-
9
-
-
2442651547
-
Efficient particle transport simulation through beam modulating devices for Monte Carlo treatment planning
-
Fippel M 2004 Efficient particle transport simulation through beam modulating devices for Monte Carlo treatment planning Med. Phys. 31 1235-42
-
(2004)
Med. Phys.
, vol.31
, Issue.5
, pp. 1235-1242
-
-
Fippel, M.1
-
10
-
-
0037340926
-
A virtual photon energy fluence model for Monte Carlo dose calculation
-
Fippel M, Haryanto F, Dohm O, Nüsslin F and Kriesen S 2003 A virtual photon energy fluence model for Monte Carlo dose calculation Med. Phys. 30 301-11
-
(2003)
Med. Phys.
, vol.30
, Issue.3
, pp. 301-311
-
-
Fippel, M.1
Haryanto, F.2
Dohm, O.3
Nüsslin, F.4
Kriesen, S.5
-
11
-
-
40049095149
-
Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm
-
Fragoso M, Pillai S, Solberg T D and Chetty I J 2008 Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm Med. Phys. 35 1028-38
-
(2008)
Med. Phys.
, vol.35
, Issue.3
, pp. 1028-1038
-
-
Fragoso, M.1
Pillai, S.2
Solberg, T.D.3
Chetty, I.J.4
-
12
-
-
34547253812
-
Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance
-
Fuss M, Sturtewagen E, De Wagter C and Georg D 2007 Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance Phys. Med. Biol. 52 4211-25
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.14
, pp. 4211-4225
-
-
Fuss, M.1
Sturtewagen, E.2
De Wagter, C.3
Georg, D.4
-
13
-
-
0037701295
-
Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies
-
Georg D, Kroupa B, Winkler P and Pötter R 2003 Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies Med. Phys. 30 1142-50
-
(2003)
Med. Phys.
, vol.30
, Issue.6
, pp. 1142-1150
-
-
Georg, D.1
Kroupa, B.2
Winkler, P.3
Pötter, R.4
-
14
-
-
71949130070
-
Advanced kernel methods versus Monte Carlo based dose calculations for high energy photon beams
-
59
-
Georg D and Winkler P 2008 Advanced kernel methods versus Monte Carlo based dose calculations for high energy photon beams Radiother. Oncol. 88 (S2) 59
-
(2008)
Radiother. Oncol.
, vol.88
, pp. 2
-
-
Georg, D.1
Winkler, P.2
-
15
-
-
0034925140
-
Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom
-
Hartmann Siantar C L et al 2001 Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom Med. Phys. 28 1322-37
-
(2001)
Med. Phys.
, vol.28
, Issue.7
, pp. 1322-1337
-
-
Hartmann Siantar, C.L.1
-
16
-
-
34250350470
-
Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases
-
Hasenbalg F, Neuenschwander H, Mini R and Born E J 2007 Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases Phys. Med. Biol. 52 3679-91
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.13
, pp. 3679-3691
-
-
Hasenbalg, F.1
Neuenschwander, H.2
Mini, R.3
Born, E.J.4
-
17
-
-
7244257425
-
Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV
-
Heath E, Seuntjens J and Sheikh-Bagheri D 2004 Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV Med. Phys. 31 2771-9
-
(2004)
Med. Phys.
, vol.31
, Issue.10
, pp. 2771-2779
-
-
Heath, E.1
Seuntjens, J.2
Sheikh-Bagheri, D.3
-
18
-
-
34347384633
-
Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis
-
Hrbacek J, Depuydt T, Nulens A, Swinnen A and Van Den Heuvel F 2007 Quantitative evaluation of a beam-matching procedure using one-dimensional gamma analysis Med. Phys. 34 2917-27
-
(2007)
Med. Phys.
, vol.34
, Issue.7
, pp. 2917-2927
-
-
Hrbacek, J.1
Depuydt, T.2
Nulens, A.3
Swinnen, A.4
Van Den Heuvel, F.5
-
19
-
-
0003680967
-
Absorbed Dose Determination in External Beam Radiotherapy
-
International Atomic Energy Agency 2000 Absorbed Dose Determination in External Beam Radiotherapy IAEA Technical Report Series No 398 (Vienna: IAEA) pp 66-83
-
(2000)
IAEA Technical Report Series No 398
, pp. 66-83
-
-
-
20
-
-
33644700897
-
Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer
-
International Atomic Energy Agency 2004 Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer IAEA Technical Report Series No 430 (Vienna: IAEA) pp 137-48
-
(2004)
IAEA Technical Report Series No 430
, pp. 137-148
-
-
-
21
-
-
33748926237
-
Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches
-
Jang S Y, Liu H H, Wang X, Vassiliev O N, Siebers J V, Dong L and Mohan R 2006 Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches Int. J. Rad. Oncol. Biol. Phys. 66 939-48
-
(2006)
Int. J. Rad. Oncol. Biol. Phys.
, vol.66
, Issue.3
, pp. 939-948
-
-
Jang, S.Y.1
Liu, H.H.2
Wang, X.3
Vassiliev, O.N.4
Siebers, J.V.5
Dong, L.6
Mohan, R.7
-
22
-
-
33744828302
-
On the effective point of measurement in megavoltage photon beams
-
Kawrakow I 2006 On the effective point of measurement in megavoltage photon beams Med. Phys. 33 1829-39
-
(2006)
Med. Phys.
, vol.33
, Issue.6
, pp. 1829-1839
-
-
Kawrakow, I.1
-
23
-
-
0033862407
-
Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
-
Kawrakow I and Fippel M 2000 Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC Phys. Med. Biol. 45 2163-83
-
(2000)
Phys. Med. Biol.
, vol.45
, Issue.8
, pp. 2163-2183
-
-
Kawrakow, I.1
Fippel, M.2
-
24
-
-
16444375876
-
Monte Carlo- versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantom
-
Krieger T and Sauer O A 2005 Monte Carlo- versus pencil-beam-/collapsed- cone-dose calculation in a heterogeneous multi-layer phantom Phys. Med. Biol. 50 859-68
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.5
, pp. 859-868
-
-
Krieger, T.1
Sauer, O.A.2
-
25
-
-
33748881814
-
Dose distribution in SBRT of lung tumors: Comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions
-
Lax I, Panettieri V, Wennberg B, Duch M A, Näslund I, Baumann P and Gagliardi G 2006 Dose distribution in SBRT of lung tumors: comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions Acta. Oncol. 45 978-88
-
(2006)
Acta. Oncol.
, vol.45
, Issue.7
, pp. 978-988
-
-
Lax, I.1
Panettieri, V.2
Wennberg, B.3
Duch, M.A.4
Näslund, I.5
Baumann, P.6
Gagliardi, G.7
-
26
-
-
33846256274
-
Comparison of 6MV and 18MV photons for IMRT treatment of lung cancer
-
Madani I, Vanderstraeten B, Bral S, Coghe M, De Gersem W, De Wagter C, Thierens H and De Neve W 2007 Comparison of 6MV and 18MV photons for IMRT treatment of lung cancer Radiother. Oncol. 82 63-9
-
(2007)
Radiother. Oncol.
, vol.82
, Issue.1
, pp. 63-69
-
-
Madani, I.1
Vanderstraeten, B.2
Bral, S.3
Coghe, M.4
De Gersem, W.5
De Wagter, C.6
Thierens, H.7
De Neve, W.8
-
27
-
-
0028953755
-
MMC-a high-performance Monte Carlo code for electron beam treatment planning
-
Neuenschwander H, Mackie T R and Reckwerdt P J 1995 MMC-a high-performance Monte Carlo code for electron beam treatment planning Phys. Med. Biol. 40 543-74
-
(1995)
Phys. Med. Biol.
, vol.40
, Issue.4
, pp. 543-574
-
-
Neuenschwander, H.1
MacKie, T.R.2
Reckwerdt, P.J.3
-
28
-
-
0038176483
-
A widely tested model for head scatter influence on photon beam output
-
Olofsson J, Georg D and Karlsson M 2003 A widely tested model for head scatter influence on photon beam output Radiother. Oncol. 67 225-38
-
(2003)
Radiother. Oncol.
, vol.67
, Issue.2
, pp. 225-238
-
-
Olofsson, J.1
Georg, D.2
Karlsson, M.3
-
29
-
-
34247503351
-
Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry
-
Paelinck L, De Neve W and De Wagter C 2007 Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry Phys. Med. Biol. 52 231-42
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.1
, pp. 231-242
-
-
Paelinck, L.1
De Neve, W.2
De Wagter, C.3
-
30
-
-
22844452234
-
Experimental verification of lung dose with radiochromic film: Comparison with Monte Carlo simulations and commercially available treatment planning systems
-
Paelinck L, Reynaert N, Thierens H, De Neve W and De Wagter C 2005 Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems Phys. Med. Biol. 50 2055-69
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.9
, pp. 2055-2069
-
-
Paelinck, L.1
Reynaert, N.2
Thierens, H.3
De Neve, W.4
De Wagter, C.5
-
31
-
-
34547331930
-
SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems
-
Panettieri V, Wennberg B, Gagliardi G, Duch M A, Ginjaume M and Lax I 2007 SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems Phys. Med. Biol. 52 4265-81
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.14
, pp. 4265-4281
-
-
Panettieri, V.1
Wennberg, B.2
Gagliardi, G.3
Duch, M.A.4
Ginjaume, M.5
Lax, I.6
-
32
-
-
33846006240
-
Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)
-
Pemler P, Besserer J, Schneider U and Neuenschwander H 2006 Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC) Z. Med. Phys. 16 313-29
-
(2006)
Z. Med. Phys.
, vol.16
, Issue.4
, pp. 313-329
-
-
Pemler, P.1
Besserer, J.2
Schneider, U.3
Neuenschwander, H.4
-
33
-
-
20144389298
-
The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations
-
Reynaert N, Coghe M, De Smedt B, Paelinck L, Vanderstraeten B, De Gersem W, Van Duyse B, De Wagter C, De Neve W and Thierens H 2005 The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations Phys. Med. Biol. 50 831-46
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.5
, pp. 831-846
-
-
Reynaert, N.1
Coghe, M.2
De Smedt, B.3
Paelinck, L.4
Vanderstraeten, B.5
De Gersem, W.6
Van Duyse, B.7
De Wagter, C.8
De Neve, W.9
Thierens, H.10
-
34
-
-
33846618618
-
Monte Carlo treatment planning for photon and electron beams
-
Reynaert N, Van Der Marck S C, Schaart D R, Van Der Zee W, Van Vliet-Vroegindeweij C, Tomsej M, Jansen J, Heijmen B, Coghe M and De Wagter C 2007 Monte Carlo treatment planning for photon and electron beams Radiat. Phys. Chem. 76 643-86
-
(2007)
Radiat. Phys. Chem.
, vol.76
, Issue.4
, pp. 643-686
-
-
Reynaert, N.1
Van Der Marck, S.C.2
Schaart, D.R.3
Van Der Zee, W.4
Van Vliet-Vroegindeweij, C.5
Tomsej, M.6
Jansen, J.7
Heijmen, B.8
Coghe, M.9
De Wagter, C.10
-
35
-
-
65449173530
-
Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam
-
Schiapparelli P, Zefiro D and Taccini G 2009 Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam Med. Phys. 36 1759-67
-
(2009)
Med. Phys.
, vol.36
, Issue.5
, pp. 1759-1767
-
-
Schiapparelli, P.1
Zefiro, D.2
Taccini, G.3
-
36
-
-
34547099077
-
A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation
-
Sikora M, Dohm O and Alber M 2007 A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation Phys. Med. Biol. 52 4449-63
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.15
, pp. 4449-4463
-
-
Sikora, M.1
Dohm, O.2
Alber, M.3
-
37
-
-
56349160061
-
An overview of Monte Carlo treatment planning for radiotherapy
-
Spezi E and Lewis G 2008 An overview of Monte Carlo treatment planning for radiotherapy Radiat. Prot. Dosim. 131 123-9
-
(2008)
Radiat. Prot. Dosim.
, vol.131
, Issue.1
, pp. 123-129
-
-
Spezi, E.1
Lewis, G.2
-
38
-
-
34247599929
-
Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator
-
Sterpin E, Tomsej M, De Smedt B, Reynaert N and Vynckier S 2007 Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator Med. Phys. 34 1665-77
-
(2007)
Med. Phys.
, vol.34
, Issue.5
, pp. 1665-1677
-
-
Sterpin, E.1
Tomsej, M.2
De Smedt, B.3
Reynaert, N.4
Vynckier, S.5
-
39
-
-
14544300121
-
Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans
-
Stock M, Kroupa B and Georg D 2005 Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans Phys. Med. Biol. 50 399-411
-
(2005)
Phys. Med. Biol.
, vol.50
, Issue.3
, pp. 399-411
-
-
Stock, M.1
Kroupa, B.2
Georg, D.3
-
40
-
-
33750574559
-
Testing of the analytical anisotropic algorithm for photon dose calculation
-
Van Esch A, Tillikainen L, Pyykkonen J, Tenhunen M, Helminen H, Siljamäki S, Alakuijala J, Paiusco M, Iori M and Huyskens D 2006 Testing of the analytical anisotropic algorithm for photon dose calculation Med. Phys. 33 4130-48
-
(2006)
Med. Phys.
, vol.33
, Issue.11
, pp. 4130-4148
-
-
Van Esch, A.1
Tillikainen, L.2
Pyykkonen, J.3
Tenhunen, M.4
Helminen, H.5
Siljamäki, S.6
Alakuijala, J.7
Paiusco, M.8
Iori, M.9
Huyskens, D.10
-
41
-
-
33748297735
-
Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
-
Vanderstraeten B, Reynaert N, Paelinck L, Madani I, De Wagter C, De Gersem W, De Neve W and Thierens H 2006 Accuracy of patient dose calculation for lung IMRT: a comparison of Monte Carlo, convolution/superposition, and pencil beam computations Med. Phys. 33 3149-58
-
(2006)
Med. Phys.
, vol.33
, Issue.9
, pp. 3149-3158
-
-
Vanderstraeten, B.1
Reynaert, N.2
Paelinck, L.3
Madani, I.4
De Wagter, C.5
De Gersem, W.6
De Neve, W.7
Thierens, H.8
-
42
-
-
38049169064
-
Dosimetric verification of a Monte Carlo electron beam model for an add-on eMLC
-
Vatanen T, Traneus E and Lahtinen T 2008 Dosimetric verification of a Monte Carlo electron beam model for an add-on eMLC Phys. Med. Biol. 53 391-404
-
(2008)
Phys. Med. Biol.
, vol.53
, Issue.2
, pp. 391-404
-
-
Vatanen, T.1
Traneus, E.2
Lahtinen, T.3
-
43
-
-
44449122864
-
Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
-
57ilcox E E and Daskalov G M 2008 Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife Med. Phys. 35 2259-66
-
(2008)
Med. Phys.
, vol.35
, Issue.6
, pp. 2259-2266
-
-
Wilcox, E.E.1
Daskalov, G.M.2
|