메뉴 건너뛰기




Volumn 30, Issue 3, 2003, Pages 301-311

A virtual photon energy fluence model for Monte Carlo dose calculation

Author keywords

Dose calculation; Monte Carlo; Photon beam modeling

Indexed keywords

BIOMEDICAL ENGINEERING; ELEMENTARY PARTICLE SOURCES; GAUSSIAN BEAMS; LINEAR ACCELERATORS; PARTICLE BEAMS; PATIENT TREATMENT; PHOTOELECTRONS; PHOTONS;

EID: 0037340926     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1543152     Document Type: Article
Times cited : (164)

References (42)
  • 1
    • 0032706348 scopus 로고    scopus 로고
    • Dose calculations for external photon beams in radiotherapy
    • A. Ahnesjö and M. M. Aspradakis, "Dose calculations for external photon beams in radiotherapy," Phys. Med. Biol. 44, R99-R155 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Ahnesjö, A.1    Aspradakis, M.M.2
  • 3
    • 0003128019 scopus 로고
    • A Monte Carlo code for particle transport
    • J. S. Hendricks, "A Monte Carlo code for particle transport," Los Alamos Sci. 22, 30-43 (1994).
    • (1994) Los Alamos Sci. , vol.22 , pp. 30-43
    • Hendricks, J.S.1
  • 5
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • I. Kawrakow. "Accurate condensed history Monte Carlo simulation of electron transport, I. EGSnrc, the new EGS4 version," Med. Phys. 27, 485-498 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 6
    • 0026565958 scopus 로고
    • A macro Monte Carlo method for electron beam dose calculations
    • H. Neuenschwander and E. Born, "A macro Monte Carlo method for electron beam dose calculations," Phys. Med. Biol. 37, 107-125 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 107-125
    • Neuenschwander, H.1    Born, E.2
  • 7
    • 0029877277 scopus 로고    scopus 로고
    • 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)
    • I. Kawrakow, M. Fippel, and K. Friedrich, "3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)," Med. Phys. 23, 445-457 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 445-457
    • Kawrakow, I.1    Fippel, M.2    Friedrich, K.3
  • 8
    • 0029987123 scopus 로고    scopus 로고
    • An accurate 3-D x-ray dose calculation method combining superposition and pre-generated Monte-Carlo electron track histories
    • P. J. Keall and P. W. Hoban, "An accurate 3-D x-ray dose calculation method combining superposition and pre-generated Monte-Carlo electron track histories," Med. Phys. 23, 479-485 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 479-485
    • Keall, P.J.1    Hoban, P.W.2
  • 9
    • 0031858002 scopus 로고    scopus 로고
    • A patient-specific Monte Carlo dose-calculation method for photon beams
    • L. Wang, C. S. Chui, and M. Lovelock, "A patient-specific Monte Carlo dose-calculation method for photon beams," Med, Phys. 25, 867-878 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 867-878
    • Wang, L.1    Chui, C.S.2    Lovelock, M.3
  • 10
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • M. Fippel, "Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm," Med. Phys. 26, 1466-1475 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1466-1475
    • Fippel, M.1
  • 11
    • 0033862407 scopus 로고    scopus 로고
    • Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
    • I. Kawrakow and M. Fippel, "Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC," Phys. Med. Biol. 45, 2163-2183 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2163-2183
    • Kawrakow, I.1    Fippel, M.2
  • 12
    • 0033867657 scopus 로고    scopus 로고
    • DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
    • J. Sempau, S. J. Wilderman, and A. F. Bielajew, "DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations," Phys. Med. Biol. 45, 2263-2291 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2263-2291
    • Sempau, J.1    Wilderman, S.J.2    Bielajew, A.F.3
  • 13
    • 0033781481 scopus 로고    scopus 로고
    • Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning
    • J. S. Li, T. Pawlicki, J. Deng, S. B. Jiang, E. Mok, and C. M. Ma, "Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning," Phys. Med. Biol. 45, 2969-2985 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2969-2985
    • Li, J.S.1    Pawlicki, T.2    Deng, J.3    Jiang, S.B.4    Mok, E.5    Ma, C.M.6
  • 15
    • 0029120085 scopus 로고
    • A Monte Carlo model of photon beams used in radiation therapy
    • D. M. J. Lovelock, C. S. Chui, and R. Mohan, "A Monte Carlo model of photon beams used in radiation therapy," Med. Phys. 22, 1387-1394 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1387-1394
    • Lovelock, D.M.J.1    Chui, C.S.2    Mohan, R.3
  • 17
    • 0036130664 scopus 로고    scopus 로고
    • Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
    • D. Sheikh-Bagheri and D. W. O. Rogers, "Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters," Med. Phys. 29, 379-390 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 379-390
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 18
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • D. Sheikh-Bagheri and D. W. O. Rogers, "Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code," Med. Phys. 29, 391-402 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 19
    • 0037035317 scopus 로고    scopus 로고
    • Energy spectra, angular spread, fluence profiles and dose distributions of 6 MV and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator
    • G. X. Ding, "Energy spectra, angular spread, fluence profiles and dose distributions of 6 MV and 18 MV photon beams: Results of Monte Carlo simulations for a Varian 2100EX accelerator," Phys. Med. Biol. 47, 1025-1046 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1025-1046
    • Ding, G.X.1
  • 20
    • 0032803619 scopus 로고    scopus 로고
    • Monte Carlo modelling of electron beams from medical accelerators
    • C. M. Ma and S. B. Jiang, "Monte Carlo modelling of electron beams from medical accelerators," Phys. Med. Biol. 44, R157-R189 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Ma, C.M.1    Jiang, S.B.2
  • 21
    • 0033962673 scopus 로고    scopus 로고
    • Photon beam characterization and modelling for Monte Carlo treatment planning
    • J. Deng, S. B. Jiang, A. Kapur, J. Li, T. Pawlicki, and C. M. Ma, "Photon beam characterization and modelling for Monte Carlo treatment planning," Phys. Med. Biol. 45, 411-427 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 411-427
    • Deng, J.1    Jiang, S.B.2    Kapur, A.3    Li, J.4    Pawlicki, T.5    Ma, C.M.6
  • 22
    • 0342748359 scopus 로고    scopus 로고
    • Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations
    • A. E. Schach von Wittenau, P. M. Bergstrom, and L. J. Cox, "Patient-dependent beam-modifier physics in Monte Carlo photon dose calculations," Med. Phys. 27, 935-947 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 935-947
    • Schach von Wittenau, A.E.1    Bergstrom, P.M.2    Cox, L.J.3
  • 23
    • 0035003832 scopus 로고    scopus 로고
    • A multiple source model for 6 MV photon beam dose calculations using Monte Carlo
    • M. K. Fix, M. Stampanoni, P. Manser, E. J. Bom, R. Mini, and P. Rüegsegger, "A multiple source model for 6 MV photon beam dose calculations using Monte Carlo," Phys. Med. Biol. 46, 1407-1427 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1407-1427
    • Fix, M.K.1    Stampanoni, M.2    Manser, P.3    Bom, E.J.4    Mini, R.5    Rüegsegger, P.6
  • 24
    • 0026697038 scopus 로고
    • Application of the convolution method for calculation of output factors for therapy photon beams
    • A. Ahnesjö T. Knöös, and A. Montelius, "Application of the convolution method for calculation of output factors for therapy photon beams," Med. Phys. 19, 295-301 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 295-301
    • Ahnesjö, A.1    Knöös, T.2    Montelius, A.3
  • 25
    • 0026472120 scopus 로고
    • On the field-size dependence of relative output from a linear accelerator
    • P. B. Dunscombe and J. M. Nieminen, "On the field-size dependence of relative output from a linear accelerator," Med. Phys. 19, 1441-1444 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 1441-1444
    • Dunscombe, P.B.1    Nieminen, J.M.2
  • 26
    • 0027966969 scopus 로고
    • Analytic modeling of photon scatter from flattening filters in photon therapy beams
    • A. Ahnesjö, "Analytic modeling of photon scatter from flattening filters in photon therapy beams," Med. Phys. 21, 1227-1235 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1227-1235
    • Ahnesjö, A.1
  • 27
    • 0028818473 scopus 로고
    • Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams
    • M. B. Sharpe, D. A. Jaffray, J. J. Battista, and P. Munro, "Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams," Med. Phys. 22, 2065-2074 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 2065-2074
    • Sharpe, M.B.1    Jaffray, D.A.2    Battista, J.J.3    Munro, P.4
  • 28
    • 0028802335 scopus 로고
    • Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model
    • M. K. Yu and R. Sloboda, "Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model," Med. Phys. 22, 2045-2055 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 2045-2055
    • Yu, M.K.1    Sloboda, R.2
  • 29
    • 0029077416 scopus 로고
    • The fraction of photons undergoing head scatter in x-ray beams
    • T. C. Zhu and B. E. Bjärngard, "The fraction of photons undergoing head scatter in x-ray beams," Phys. Med. Biol. 40, 1127-1134 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1127-1134
    • Zhu, T.C.1    Bjärngard, B.E.2
  • 30
    • 0029991359 scopus 로고    scopus 로고
    • Flattening-filter-based empirical methods to parametrize the head scatter factor
    • K. L. Lam, M. S. Muthuswamy, and R. K. Ten Haken, "Flattening-filter-based empirical methods to parametrize the head scatter factor," Med. Phys. 23, 343-352 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 343-352
    • Lam, K.L.1    Muthuswamy, M.S.2    Ten Haken, R.K.3
  • 31
    • 0031439563 scopus 로고    scopus 로고
    • Clinical implementation of a two-component x-ray source model for calculation of head-scatter factors
    • P. A. Jursinic. "Clinical implementation of a two-component x-ray source model for calculation of head-scatter factors," Med. Phys. 24, 2001-2007 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 2001-2007
    • Jursinic, P.A.1
  • 32
    • 0031466421 scopus 로고    scopus 로고
    • A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams
    • H. H. Liu, T. R. Mackie, and E. C. McCullough, "A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams," Med. Phys. 24, 1960-1974 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1960-1974
    • Liu, H.H.1    Mackie, T.R.2    McCullough, E.C.3
  • 33
    • 0031467698 scopus 로고    scopus 로고
    • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model
    • H. H. Liu, T. R. Mackie, and E. C. McCullough, "Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model," Med. Phys. 24, 1975-1985 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1975-1985
    • Liu, H.H.1    Mackie, T.R.2    McCullough, E.C.3
  • 34
    • 0034977515 scopus 로고    scopus 로고
    • Modeling the output ratio in air for megavoltage photon beams
    • T. C. Zhu, B. E. Bjärngard, Y. Xiao, and C. J. Yang, "Modeling the output ratio in air for megavoltage photon beams," Med. Phys. 28, 925-937 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 925-937
    • Zhu, T.C.1    Bjärngard, B.E.2    Xiao, Y.3    Yang, C.J.4
  • 35
    • 0036735826 scopus 로고    scopus 로고
    • A three-source model for the calculation of head scatter factors
    • Y. Yang, L. Xing, A. L. Boyer, Y. Song, and Y. Hu, "A three-source model for the calculation of head scatter factors," Med. Phys. 29, 2024-2033 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2024-2033
    • Yang, Y.1    Xing, L.2    Boyer, A.L.3    Song, Y.4    Hu, Y.5
  • 36
    • 0035142023 scopus 로고    scopus 로고
    • Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation
    • S. B. Jiang, A. L. Boyer, and C. M. Ma, "Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation," Med. Phys. 28, 55-66 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 55-66
    • Jiang, S.B.1    Boyer, A.L.2    Ma, C.M.3
  • 38
    • 0031805316 scopus 로고    scopus 로고
    • A generic off-axis energy correction for linac photon beam dosimetry
    • R. C. Tailor, V. M. Tello, C. B. Schroy, M. Vossler, and W, F. Hanson, "A generic off-axis energy correction for linac photon beam dosimetry," Med. Phys. 25, 662-667 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 662-667
    • Tailor, R.C.1    Tello, V.M.2    Schroy, C.B.3    Vossler, M.4    Hanson, W.F.5
  • 40
    • 0003966099 scopus 로고
    • Technical Report No. NBSIR 87-3597, National Institute of Standards and Technology Gaithersburg, MD
    • M. J. Berger and J. H. Hubbell, "XCOM: Photon cross sections on a personal computer," Technical Report No. NBSIR 87-3597, National Institute of Standards and Technology Gaithersburg, MD, 1987.
    • (1987) XCOM: Photon Cross Sections on a Personal Computer
    • Berger, M.J.1    Hubbell, J.H.2
  • 42
    • 0037035943 scopus 로고    scopus 로고
    • Investigation of photon beam output factors for conformal radiation therapy - Monte Carlo simulations and measurements
    • F. Haryanto, M. Fippel, W. Laub, O. Dohm, and F. Nüsslin, "Investigation of photon beam output factors for conformal radiation therapy - Monte Carlo simulations and measurements," Phys. Med. Biol. 47, N133-N143 (2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Haryanto, F.1    Fippel, M.2    Laub, W.3    Dohm, O.4    Nüsslin, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.