메뉴 건너뛰기




Volumn 25, Issue 3, 2009, Pages 111-121

Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements

Author keywords

Electron beam dosimetry; Electron treatment planning; Monte Carlo; Output factors

Indexed keywords

ACCURACY; ARTICLE; CONTROLLED STUDY; DOSIMETRY; ELECTRON BEAM; ELECTRON THERAPY; INTERMETHOD COMPARISON; MONTE CARLO METHOD; PHANTOM; RADIATION DEPTH DOSE; RADIATION DOSE DISTRIBUTION; RADIATION FIELD; SIMULATION;

EID: 68849122593     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejmp.2008.07.001     Document Type: Article
Times cited : (23)

References (32)
  • 1
    • 0026013526 scopus 로고
    • Pencil-beam redefinition algorithm for electron dose distributions
    • Shiu A.S., and Hogstrom K.R. Pencil-beam redefinition algorithm for electron dose distributions. Med Phys 18 (1991) 7-18
    • (1991) Med Phys , vol.18 , pp. 7-18
    • Shiu, A.S.1    Hogstrom, K.R.2
  • 2
    • 0023631671 scopus 로고
    • Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations
    • Cygler J., Battista J.J., Scrimger J.W., Mah E., and Antolak J. Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculations. Phys Med Biol 32 (1987) 1073-1086
    • (1987) Phys Med Biol , vol.32 , pp. 1073-1086
    • Cygler, J.1    Battista, J.J.2    Scrimger, J.W.3    Mah, E.4    Antolak, J.5
  • 3
    • 0024347237 scopus 로고
    • Experimental evaluation of 2D and 3D electron pencil beam algorithm
    • Mah E., Antolak J., Scrimger J.W., and Battista JJ. Experimental evaluation of 2D and 3D electron pencil beam algorithm. Phys Med Biol 34 (1989) 1174-1194
    • (1989) Phys Med Biol , vol.34 , pp. 1174-1194
    • Mah, E.1    Antolak, J.2    Scrimger, J.W.3    Battista, JJ.4
  • 5
    • 0021256061 scopus 로고
    • Dosimetric evaluation of a pencil-beam algorithm for electrons employing a twodimensional heterogeneity correction
    • Hogstrom K.R., Mills M.D., Meyer J.A., Palta J.R., Mellenberg D.E., Meoz R.T., et al. Dosimetric evaluation of a pencil-beam algorithm for electrons employing a twodimensional heterogeneity correction. Int J Radiat Oncol Biol Phys 10 (1984) 561-569
    • (1984) Int J Radiat Oncol Biol Phys , vol.10 , pp. 561-569
    • Hogstrom, K.R.1    Mills, M.D.2    Meyer, J.A.3    Palta, J.R.4    Mellenberg, D.E.5    Meoz, R.T.6
  • 7
    • 68849113845 scopus 로고    scopus 로고
    • Quality assurance of 3-D treatment planning systems for external photon and electron beams: practical guidelines for acceptance testing, commissioning and periodic quality control of radiation therapy treatment planning systems
    • Bruinvis I.A.D., Keus R.B., Lenglet W.J.M., Meijer G.J., Mijnheer B.J., van't Veld A.A., et al. Quality assurance of 3-D treatment planning systems for external photon and electron beams: practical guidelines for acceptance testing, commissioning and periodic quality control of radiation therapy treatment planning systems. NCS Report 15 (2006)
    • (2006) NCS Report , vol.15
    • Bruinvis, I.A.D.1    Keus, R.B.2    Lenglet, W.J.M.3    Meijer, G.J.4    Mijnheer, B.J.5    van't Veld, A.A.6
  • 8
    • 0030945205 scopus 로고    scopus 로고
    • Accurate characterization of Monte Carlo calculated electron beams for radiotherapy
    • Ma C.M., Faddegon B.A., Rogers D.W.O., and Mackie TR. Accurate characterization of Monte Carlo calculated electron beams for radiotherapy. Med Phys 24 (1997) 401-416
    • (1997) Med Phys , vol.24 , pp. 401-416
    • Ma, C.M.1    Faddegon, B.A.2    Rogers, D.W.O.3    Mackie, TR.4
  • 9
    • 0032957195 scopus 로고    scopus 로고
    • Monte Carlo investigation of electron beam output factors versus size of square cutout
    • Zhang G.G., Rogers D.W.O., Cygler J.E., and Mackie TR. Monte Carlo investigation of electron beam output factors versus size of square cutout. Med Phys 26 (1999) 743-750
    • (1999) Med Phys , vol.26 , pp. 743-750
    • Zhang, G.G.1    Rogers, D.W.O.2    Cygler, J.E.3    Mackie, TR.4
  • 10
    • 0031766241 scopus 로고    scopus 로고
    • Monte Carlo calculations of electron beam output factors for a medical linear accelerator
    • Kapur A., Ma C.M., Mok E.C., David O.F., and Arthur L.B. Monte Carlo calculations of electron beam output factors for a medical linear accelerator. Phys Med Biol 43 (1998) 3479-3494
    • (1998) Phys Med Biol , vol.43 , pp. 3479-3494
    • Kapur, A.1    Ma, C.M.2    Mok, E.C.3    David, O.F.4    Arthur, L.B.5
  • 11
    • 85027226648 scopus 로고    scopus 로고
    • Monte Carlo calculations of output factors for clinically shaped electron fields
    • Turian J.V., Smith B.D., Bernard D.A., Griem K.L., and Chu J.C. Monte Carlo calculations of output factors for clinically shaped electron fields. J Appl Clin Med Phys 5 (2004) 42-62
    • (2004) J Appl Clin Med Phys , vol.5 , pp. 42-62
    • Turian, J.V.1    Smith, B.D.2    Bernard, D.A.3    Griem, K.L.4    Chu, J.C.5
  • 12
    • 0141514462 scopus 로고    scopus 로고
    • Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields
    • Pavon E.C., Sanchez-Doblado F., Leal A., Capote R., Lagares J.I., Perucha M., et al. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields. Phys Med Biol 48 (2003) 2783-2796
    • (2003) Phys Med Biol , vol.48 , pp. 2783-2796
    • Pavon, E.C.1    Sanchez-Doblado, F.2    Leal, A.3    Capote, R.4    Lagares, J.I.5    Perucha, M.6
  • 13
    • 22244482238 scopus 로고    scopus 로고
    • Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
    • Popescu I.A., Shaw C.P., Zavgorodni S.F., and Beckham WA. Absolute dose calculations for Monte Carlo simulations of radiotherapy beams. Phys Med Biol 50 (2005) 3375-3392
    • (2005) Phys Med Biol , vol.50 , pp. 3375-3392
    • Popescu, I.A.1    Shaw, C.P.2    Zavgorodni, S.F.3    Beckham, WA.4
  • 15
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • Kawrakow I. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med Phys 27 (2000) 485-498
    • (2000) Med Phys , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 18
    • 0033862407 scopus 로고    scopus 로고
    • Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC
    • Kawrakow I., and Fippel M. Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC. Phys Med Biol 45 (2000) 2163-2183
    • (2000) Phys Med Biol , vol.45 , pp. 2163-2183
    • Kawrakow, I.1    Fippel, M.2
  • 19
    • 0030937534 scopus 로고    scopus 로고
    • Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group
    • Fippel M., Kawrakow I., and Friedrich K. Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group. Phys Med Biol 42 (1997) 501-520
    • (1997) Phys Med Biol , vol.42 , pp. 501-520
    • Fippel, M.1    Kawrakow, I.2    Friedrich, K.3
  • 20
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • Fippel M. Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm. Med Phys 26 (1999) 1466-1475
    • (1999) Med Phys , vol.26 , pp. 1466-1475
    • Fippel, M.1
  • 21
    • 0037150009 scopus 로고    scopus 로고
    • A Monte Carlo dose calculation tool for radiotherapy treatment planning
    • Ma C.M., Li J.S., Pawlicki T., Jiang S.B., Deng J., Lee M.C., et al. A Monte Carlo dose calculation tool for radiotherapy treatment planning. Phys Med Biol 47 (2000) 1671-1689
    • (2000) Phys Med Biol , vol.47 , pp. 1671-1689
    • Ma, C.M.1    Li, J.S.2    Pawlicki, T.3    Jiang, S.B.4    Deng, J.5    Lee, M.C.6
  • 22
    • 0042977323 scopus 로고    scopus 로고
    • Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams
    • Doucet R.M., Olivares M., DeBlois F., Podgorsak E.B., Kawrakow I., and Seuntjens J. Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams. Phys Med Biol 48 (2003) 2339-2354
    • (2003) Phys Med Biol , vol.48 , pp. 2339-2354
    • Doucet, R.M.1    Olivares, M.2    DeBlois, F.3    Podgorsak, E.B.4    Kawrakow, I.5    Seuntjens, J.6
  • 23
    • 1642495638 scopus 로고    scopus 로고
    • Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning
    • Cygler J.E., Daskalov G.M., Chan G.H., and Ding GX. Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning. Med Phys 31 (2004) 142-153
    • (2004) Med Phys , vol.31 , pp. 142-153
    • Cygler, J.E.1    Daskalov, G.M.2    Chan, G.H.3    Ding, GX.4
  • 24
    • 24944573066 scopus 로고    scopus 로고
    • A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    • Ding G.X., Cygler J.E., Yu W.C., Kalach Nina I., and Daskalov G. A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm. Int J Radiat Oncol Biol Phys 63 (2005) 622-633
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 622-633
    • Ding, G.X.1    Cygler, J.E.2    Yu, W.C.3    Kalach Nina, I.4    Daskalov, G.5
  • 25
    • 33744804592 scopus 로고    scopus 로고
    • Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set
    • Popple A.R., Weinberg R., Antolak A.J., Sung-Joon Y., Prem N.P., Duan J., et al. Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set. Med Phys 33 (2006) 1540-1551
    • (2006) Med Phys , vol.33 , pp. 1540-1551
    • Popple, A.R.1    Weinberg, R.2    Antolak, A.J.3    Sung-Joon, Y.4    Prem, N.P.5    Duan, J.6
  • 26
    • 33744818167 scopus 로고    scopus 로고
    • First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning - new issues for clinical consideration
    • Ding G.X., Duggan M.D., Coffey W.C., Parvaneh S., and Cygler JE. First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning - new issues for clinical consideration. Phys Med Biol 51 (2006) 2781-2799
    • (2006) Phys Med Biol , vol.51 , pp. 2781-2799
    • Ding, G.X.1    Duggan, M.D.2    Coffey, W.C.3    Parvaneh, S.4    Cygler, JE.5
  • 27
    • 33746511273 scopus 로고    scopus 로고
    • Absorbed dose determination in external beam radiotherapy: an International Code of Practice for dosimetry based on standards of absorbed dose to water
    • Andreo P., Burns D.T., Hohlfeld K., Huq M.S., Kanai T., Laitano F., et al. Absorbed dose determination in external beam radiotherapy: an International Code of Practice for dosimetry based on standards of absorbed dose to water. IAEA TRS 398 (2000)
    • (2000) IAEA TRS , vol.398
    • Andreo, P.1    Burns, D.T.2    Hohlfeld, K.3    Huq, M.S.4    Kanai, T.5    Laitano, F.6
  • 28
    • 0028584178 scopus 로고
    • Comparison of measured and calculated dose distributions in lung after electron beam treatment of the chest wall
    • Seutjens J., Van der Plaetsen A., Thierens H., and Piessens M. Comparison of measured and calculated dose distributions in lung after electron beam treatment of the chest wall. Med Phys 21 (1994) 1959-1968
    • (1994) Med Phys , vol.21 , pp. 1959-1968
    • Seutjens, J.1    Van der Plaetsen, A.2    Thierens, H.3    Piessens, M.4
  • 29
    • 0142025621 scopus 로고    scopus 로고
    • The response of Kodak EDR2 film in high-energy electron beams
    • Gerbi J.B., and Dimitroyannis D.A. The response of Kodak EDR2 film in high-energy electron beams. Med Phys 30 (2003) 2703-2705
    • (2003) Med Phys , vol.30 , pp. 2703-2705
    • Gerbi, J.B.1    Dimitroyannis, D.A.2
  • 30
    • 0038644818 scopus 로고    scopus 로고
    • National Research Council of Canada, Ottawa NRCC Report No. PIRS-794 rev A
    • Walters B.R.B., and Rogers D.W.O. DOSXYZnrc user manuel (2004), National Research Council of Canada, Ottawa NRCC Report No. PIRS-794 rev A
    • (2004) DOSXYZnrc user manuel
    • Walters, B.R.B.1    Rogers, D.W.O.2
  • 31
    • 0022545872 scopus 로고
    • A method for conversion of Hounsfield number to electron density and prediction of macroscopic pair production cross-sections
    • Knöös T., Nilsson M., and Ahlgren L. A method for conversion of Hounsfield number to electron density and prediction of macroscopic pair production cross-sections. Radiother Oncol 5 (1986) 337-345
    • (1986) Radiother Oncol , vol.5 , pp. 337-345
    • Knöös, T.1    Nilsson, M.2    Ahlgren, L.3
  • 32
    • 0033405522 scopus 로고    scopus 로고
    • Evaluation of a commercial three-dimensional electron beam treatment planning system
    • Ding G.X., Cygler J.E., and Yu M.K. Evaluation of a commercial three-dimensional electron beam treatment planning system. Med Phys 26 (1999) 2571-2580
    • (1999) Med Phys , vol.26 , pp. 2571-2580
    • Ding, G.X.1    Cygler, J.E.2    Yu, M.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.