메뉴 건너뛰기




Volumn 67, Issue 2, 2003, Pages 225-238

A widely tested model for head scatter influence on photon beam output

Author keywords

Extra focal scatter source; Output factor in air; Semi analytical head scatter model

Indexed keywords

ARTICLE; CALCULATION; CLINICAL STUDY; COLLIMATOR; EXPERIMENTAL TEST; GEOMETRY; HEAD; MEASUREMENT; MODEL; PHOTON; PRIORITY JOURNAL; RADIATION BEAM; RADIATION DOSE;

EID: 0038176483     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(02)00409-7     Document Type: Article
Times cited : (22)

References (28)
  • 1
    • 0026697038 scopus 로고
    • Application of the convolution method for calculation of output factors for therapy photon beams
    • Ahnesjö A., Knöös T., Montelius A. Application of the convolution method for calculation of output factors for therapy photon beams. Med Phys. 19:1992;295-301.
    • (1992) Med Phys , vol.19 , pp. 295-301
    • Ahnesjö, A.1    Knöös, T.2    Montelius, A.3
  • 2
    • 0027966969 scopus 로고
    • Analytical modeling of photon scatter from flattening filters in photon therapy beams
    • Ahnesjö A. Analytical modeling of photon scatter from flattening filters in photon therapy beams. Med Phys. 21:1994;1227-1235.
    • (1994) Med Phys , vol.21 , pp. 1227-1235
    • Ahnesjö, A.1
  • 3
    • 0028922435 scopus 로고
    • Collimator scatter in photon beams
    • Ahnesjö A. Collimator scatter in photon beams. Med Phys. 22:1995;267-278.
    • (1995) Med Phys , vol.22 , pp. 267-278
    • Ahnesjö, A.1
  • 4
    • 0028783999 scopus 로고
    • Modeling transmission and scatter for photon beam attenuators
    • Ahnesjö A., Weber L., Nilsson P. Modeling transmission and scatter for photon beam attenuators. Med Phys. 22:1995;1711-1720.
    • (1995) Med Phys , vol.22 , pp. 1711-1720
    • Ahnesjö, A.1    Weber, L.2    Nilsson, P.3
  • 5
    • 0031690712 scopus 로고    scopus 로고
    • Beam characteristics of a retrofitted double focused multileaf collimator
    • Das I.J., Desobry G.E., McNeeley S.W., Cheng E., Schutheiss T.E. Beam characteristics of a retrofitted double focused multileaf collimator. Med Phys. 25:1998;1676-1684.
    • (1998) Med Phys , vol.25 , pp. 1676-1684
    • Das, I.J.1    Desobry, G.E.2    McNeeley, S.W.3    Cheng, E.4    Schutheiss, T.E.5
  • 7
    • 0026472120 scopus 로고
    • On the field size dependence of relative output factors from a linear accelerator
    • Dunscombe N., Nieminen J.M. On the field size dependence of relative output factors from a linear accelerator. Med Phys. 19:1992;1441-1444.
    • (1992) Med Phys , vol.19 , pp. 1441-1444
    • Dunscombe, N.1    Nieminen, J.M.2
  • 8
    • 0032800939 scopus 로고    scopus 로고
    • Monitor unit calculation on the beams axis of open and wedged asymmetric high-energy photon beams
    • Georg D. Monitor unit calculation on the beams axis of open and wedged asymmetric high-energy photon beams. Phys Med Biol. 44:1999;2987-3007.
    • (1999) Phys Med Biol , vol.44 , pp. 2987-3007
    • Georg, D.1
  • 9
    • 0029773929 scopus 로고    scopus 로고
    • The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields
    • Hounsell A.R., Wilkinson J.M. The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields. Phys Med Biol. 41:1996;2155-2172.
    • (1996) Phys Med Biol , vol.41 , pp. 2155-2172
    • Hounsell, A.R.1    Wilkinson, J.M.2
  • 10
    • 0030758971 scopus 로고    scopus 로고
    • Head scatter modeling for irregular field shaping and beam intensity modulation
    • Hounsell A.R., Wilkinson J.M. Head scatter modeling for irregular field shaping and beam intensity modulation. Phys Med Biol. 42:1997;1737-1749.
    • (1997) Phys Med Biol , vol.42 , pp. 1737-1749
    • Hounsell, A.R.1    Wilkinson, J.M.2
  • 11
    • 0035142023 scopus 로고    scopus 로고
    • Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation
    • Jiang S.B., Boyer A.L., Ma C.M. Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation. Med Phys. 28:2001;55-66.
    • (2001) Med Phys , vol.28 , pp. 55-66
    • Jiang, S.B.1    Boyer, A.L.2    Ma, C.M.3
  • 12
    • 0031439563 scopus 로고    scopus 로고
    • Clinical implementation of a two-component x-ray source model for calculation of head scatter factors
    • Jursinic P. Clinical implementation of a two-component x-ray source model for calculation of head scatter factors. Med Phys. 24:1997;2001-2007.
    • (1997) Med Phys , vol.24 , pp. 2001-2007
    • Jursinic, P.1
  • 14
    • 0022471631 scopus 로고
    • Head scatter data for several linear accelerators (4-18MV)
    • Kase K., Svensson G.K. Head scatter data for several linear accelerators (4-18MV). Med Phys. 13:1986;530-532.
    • (1986) Med Phys , vol.13 , pp. 530-532
    • Kase, K.1    Svensson, G.K.2
  • 15
    • 0031837396 scopus 로고    scopus 로고
    • The equivalent square concept for the head scatter based on scatter from flattening filter
    • Kim S., Palta J., Zhu T.C. The equivalent square concept for the head scatter based on scatter from flattening filter. Phys Med Biol. 43:1998;1593-1603.
    • (1998) Phys Med Biol , vol.43 , pp. 1593-1603
    • Kim, S.1    Palta, J.2    Zhu, T.C.3
  • 16
    • 0033026880 scopus 로고    scopus 로고
    • Two effective source method for the calculation of in-air output at various source to detector distances in wedged fields
    • Kim S., Liu C., Chen C., Palta J.R. Two effective source method for the calculation of in-air output at various source to detector distances in wedged fields. Med Phys. 26:1999;949-955.
    • (1999) Med Phys , vol.26 , pp. 949-955
    • Kim, S.1    Liu, C.2    Chen, C.3    Palta, J.R.4
  • 17
    • 0029991359 scopus 로고    scopus 로고
    • Flattening filter based empirical methods to parameterise the head scatter factor
    • Lam K.L., Muthuswamy S., TenHaken R.K. Flattening filter based empirical methods to parameterise the head scatter factor. Med Phys. 23:1996;343-352.
    • (1996) Med Phys , vol.23 , pp. 343-352
    • Lam, K.L.1    Muthuswamy, S.2    TenHaken, R.K.3
  • 18
    • 0031467698 scopus 로고    scopus 로고
    • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model
    • Liu H., Mackie T.R., McCullogh E.C. Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model. Med Phys. 24:1997;1975-1985.
    • (1997) Med Phys , vol.24 , pp. 1975-1985
    • Liu, H.1    Mackie, T.R.2    McCullogh, E.C.3
  • 19
    • 0023905228 scopus 로고
    • Output factor constituents of a high-energy photon beam
    • Luxton G., Astrahan M.A. Output factor constituents of a high-energy photon beam. Med Phys. 15:1988;88-91.
    • (1988) Med Phys , vol.15 , pp. 88-91
    • Luxton, G.1    Astrahan, M.A.2
  • 20
    • 0034918182 scopus 로고    scopus 로고
    • Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing
    • Naqvi S.A., Sarfaraz M., Holmes T., Yu C.X., Li X.A. Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing. Phys Med Biol. 46:2001;2009-2028.
    • (2001) Phys Med Biol , vol.46 , pp. 2009-2028
    • Naqvi, S.A.1    Sarfaraz, M.2    Holmes, T.3    Yu, C.X.4    Li, X.A.5
  • 21
    • 0032969026 scopus 로고    scopus 로고
    • A macropencil beam model: Clinical implementation for conformal radiotherapy and intensity modulated radiotherapy
    • Philips M.H., Singer M.K., Hounsell A.R. A macropencil beam model: clinical implementation for conformal radiotherapy and intensity modulated radiotherapy. Phys Med Biol. 44:1999;1067-1088.
    • (1999) Phys Med Biol , vol.44 , pp. 1067-1088
    • Philips, M.H.1    Singer, M.K.2    Hounsell, A.R.3
  • 22
    • 0025350649 scopus 로고
    • Collimator scatter in modelling radiation beam profiles
    • Rosen L.M.D. II, Lane R.G. Collimator scatter in modelling radiation beam profiles. Med Phys. 17:1990;422-428.
    • (1990) Med Phys , vol.17 , pp. 422-428
    • Rosen L.M.D. II1    Lane, R.G.2
  • 23
    • 0028818473 scopus 로고
    • Extra focal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams
    • Sharpe M.B., Jaffray D.A., Battista J.J., Munro P. Extra focal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams. Med Phys. 22:1995;2065-2074.
    • (1995) Med Phys , vol.22 , pp. 2065-2074
    • Sharpe, M.B.1    Jaffray, D.A.2    Battista, J.J.3    Munro, P.4
  • 25
    • 0030866208 scopus 로고    scopus 로고
    • Build-up cap materials for measurement of photon head scatter factors Phys
    • Weber L., Nilsson P., Ahnesjö A. Build-up cap materials for measurement of photon head scatter factors Phys. Med Biol. 42:1997;1875-1886.
    • (1997) Med Biol , vol.42 , pp. 1875-1886
    • Weber, L.1    Nilsson, P.2    Ahnesjö, A.3
  • 26
    • 0029088228 scopus 로고
    • Parametrization of head scatter factors for rectangular photon fields using an equivalent square formalism
    • Yu M.K., Murray B., Sloboda R. Parametrization of head scatter factors for rectangular photon fields using an equivalent square formalism. Med Phys. 22:1995;1329-1332.
    • (1995) Med Phys , vol.22 , pp. 1329-1332
    • Yu, M.K.1    Murray, B.2    Sloboda, R.3
  • 27
    • 0028802335 scopus 로고
    • Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model
    • Yu M.K., Sloboda R. Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model. Med Phys. 22:1995;2045-2055.
    • (1995) Med Phys , vol.22 , pp. 2045-2055
    • Yu, M.K.1    Sloboda, R.2
  • 28
    • 0030936245 scopus 로고    scopus 로고
    • Effect of beam blocking on linac head scatter factors
    • Yu M.K., Sloboda R. Effect of beam blocking on linac head scatter factors. Int J Radiat Oncol Biol Phys. 37:1997;465-468.
    • (1997) Int J Radiat Oncol Biol Phys , vol.37 , pp. 465-468
    • Yu, M.K.1    Sloboda, R.2