메뉴 건너뛰기




Volumn 16, Issue 4, 2006, Pages 313-329

Evaluation of a commercial electron treatment planning system based on Monte Carlo techniques (eMC)

Author keywords

Commissioning; Electrons; Monte Carlo; Treatment planning

Indexed keywords

ARTICLE; CALIBRATION; CONTROLLED STUDY; DOSE CALCULATION; ELECTRON BEAM; HUMAN; MATHEMATICAL ANALYSIS; MONTE CARLO METHOD; PHANTOM; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 33846006240     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1078/0939-3889-00330     Document Type: Article
Times cited : (29)

References (18)
  • 1
    • 84939588546 scopus 로고    scopus 로고
    • Kawrakow, I.: VMC++ electron and photon Monte Carlo calculations optimised for radiation treatment planning. In: Advanced Monte Carlo on Radiation Physics, Particle Transport Simulation and Applications (ds.: A. Kling, F. Bararo, M. Nakagawa, L. Tavora, P. Vaz), Springer Verlag, Berlin-Heidelberg-New York, 229-236
    • Kawrakow, I.: VMC++ electron and photon Monte Carlo calculations optimised for radiation treatment planning. In: Advanced Monte Carlo on Radiation Physics, Particle Transport Simulation and Applications (ds.: A. Kling, F. Bararo, M. Nakagawa, L. Tavora, P. Vaz), Springer Verlag, Berlin-Heidelberg-New York, 229-236
  • 2
    • 0029877277 scopus 로고    scopus 로고
    • 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)
    • Kawarakow, I., Fippel, M., Friedrich, K.: 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC). Med. Phys. 23 (1996) 445-457
    • (1996) Med. Phys , vol.23 , pp. 445-457
    • Kawarakow, I.1    Fippel, M.2    Friedrich, K.3
  • 4
    • 33744804592 scopus 로고    scopus 로고
    • Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification set
    • Popple, R., Weinberg, R., Antolak, J., Ye, S., Pareek, P., Duan, J., Shen, S., Brezovich, I.: Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification set. Med. Phys. 33 (2006) 1540-1551
    • (2006) Med. Phys , vol.33 , pp. 1540-1551
    • Popple, R.1    Weinberg, R.2    Antolak, J.3    Ye, S.4    Pareek, P.5    Duan, J.6    Shen, S.7    Brezovich, I.8
  • 5
    • 33744818167 scopus 로고    scopus 로고
    • First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning - new issues for clinical consideration
    • Ding, G., Duggan, D., Coffey, C., Shokrani, P., Cygler, J.: First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning - new issues for clinical consideration. Phys. Med. Biol. 51 (2006) 2781-2799
    • (2006) Phys. Med. Biol , vol.51 , pp. 2781-2799
    • Ding, G.1    Duggan, D.2    Coffey, C.3    Shokrani, P.4    Cygler, J.5
  • 6
    • 85030500394 scopus 로고    scopus 로고
    • Varian_Medical_Systems: The Reference Guide for Eclipse Algorithms version 6.5 (P/N B401653R01M). 2005
    • Varian_Medical_Systems: The Reference Guide for Eclipse Algorithms version 6.5 (P/N B401653R01M). 2005
  • 7
    • 84907107159 scopus 로고    scopus 로고
    • Lax, I., Brahme, A.: Elektron Beam Dose Planning Using Gaussian Beams. Acta Radiologica Oncology 24 (1985) 75-85
    • Lax, I., Brahme, A.: Elektron Beam Dose Planning Using Gaussian Beams. Acta Radiologica Oncology 24 (1985) 75-85
  • 9
    • 24944573066 scopus 로고    scopus 로고
    • A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
    • Ding, G., Cygler, J., Yu, C., Kalach, N., Daskalov, G.: A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm. Int. J. Radiat. Oncol. Biol Phys. 63 (2005) 622-633
    • (2005) Int. J. Radiat. Oncol. Biol Phys , vol.63 , pp. 622-633
    • Ding, G.1    Cygler, J.2    Yu, C.3    Kalach, N.4    Daskalov, G.5
  • 11
    • 0033405522 scopus 로고    scopus 로고
    • Evaluation of a commercial three-dimensional electron beam treatment planning system
    • Ding, G., Cygler, J., Zhang, G., Yu, M.: Evaluation of a commercial three-dimensional electron beam treatment planning system. Med. Phys. 26 (1999) 2571-2580
    • (1999) Med. Phys , vol.26 , pp. 2571-2580
    • Ding, G.1    Cygler, J.2    Zhang, G.3    Yu, M.4
  • 12
    • 0035128760 scopus 로고    scopus 로고
    • A model to determine the initial phase space of a clinical electron beam from measured beam data
    • Janssen, J., Korevaar, E., Battum, L., Storchi, P., Huizenga, H.: A model to determine the initial phase space of a clinical electron beam from measured beam data. Phys. Med. Biol. 46 (2001) 269-286
    • (2001) Phys. Med. Biol , vol.46 , pp. 269-286
    • Janssen, J.1    Korevaar, E.2    Battum, L.3    Storchi, P.4    Huizenga, H.5
  • 13
    • 0026565958 scopus 로고
    • A macro Monte Carlo method for electron beam dose calculations
    • Neuenschwander, H., Born, E.: A macro Monte Carlo method for electron beam dose calculations. Phys. Med. Biol. 37 (1992) 107-125
    • (1992) Phys. Med. Biol , vol.37 , pp. 107-125
    • Neuenschwander, H.1    Born, E.2
  • 14
    • 0028953755 scopus 로고
    • MMC - a high performance Monte Carlo Code for electron beam treatment planning
    • Neuenschwander, H., Mackie, T., Reckwerdt, P.: MMC - a high performance Monte Carlo Code for electron beam treatment planning. Phys. Med. Biol. 40 (1995) 543-574
    • (1995) Phys. Med. Biol , vol.40 , pp. 543-574
    • Neuenschwander, H.1    Mackie, T.2    Reckwerdt, P.3
  • 15
    • 0035073179 scopus 로고    scopus 로고
    • Evaluation des Elektronendichtephantoms CIRS Model 62
    • Pemler, P., Schneider, U., Besserer, J.: Evaluation des Elektronendichtephantoms CIRS Model 62. Z. Med. Phys. 11 (2001) 25-32
    • (2001) Z. Med. Phys , vol.11 , pp. 25-32
    • Pemler, P.1    Schneider, U.2    Besserer, J.3
  • 16
    • 0029665664 scopus 로고    scopus 로고
    • Burn,s D., Ding, G., Rogers, D.: R50 as a beam quality specifier for selecting stopping-power ratios and refernce depth for electron dosimetry. Med. Phys. 23 (1996) 383-388
    • Burn,s D., Ding, G., Rogers, D.: R50 as a beam quality specifier for selecting stopping-power ratios and refernce depth for electron dosimetry. Med. Phys. 23 (1996) 383-388
  • 17
    • 33845997325 scopus 로고    scopus 로고
    • Recommendation No. 10: High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers
    • Swiss Society of Radiobiology and Medical Physics
    • Swiss Society of Radiobiology and Medical Physics: Recommendation No. 10: High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers. ISBN 3-908 125 30-8, 2002
    • (2002) ISBN , vol.3-908 , Issue.125 , pp. 30-38
  • 18
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low, D., Harms, W., Mutic, S., Purdy, J.: A technique for the quantitative evaluation of dose distributions. Med. Phys 25 (1998) 656-661
    • (1998) Med. Phys , vol.25 , pp. 656-661
    • Low, D.1    Harms, W.2    Mutic, S.3    Purdy, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.