-
1
-
-
0028079558
-
Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D
-
Bhagwandien R, Moerland MA, Bakker CJG, Beersma R, Lagenijk JJW. Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. Magn. Reson. Imag. 1994; 12: 101-107.
-
(1994)
Magn. Reson. Imag.
, vol.12
, pp. 101-107
-
-
Bhagwandien, R.1
Moerland, M.A.2
Bakker, C.J.G.3
Beersma, R.4
Lagenijk, J.J.W.5
-
2
-
-
0029911435
-
Threedimensional mapping of the static magnetic field inside the human head
-
Li S, Dardzinski BJ, Collins CM, Yang QX, Smith MB. Threedimensional mapping of the static magnetic field inside the human head. Magn. Reson. Med. 1999; 36: 705-714.
-
(1999)
Magn. Reson. Med.
, vol.36
, pp. 705-714
-
-
Li, S.1
Dardzinski, B.J.2
Collins, C.M.3
Yang, Q.X.4
Smith, M.B.5
-
3
-
-
0036592745
-
Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head
-
Collins CM, Yang B, Yang QX, Smith MB. Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head. Magn. Reson. Imaging 2002; 20: 413-424.
-
(2002)
Magn. Reson. Imaging
, vol.20
, pp. 413-424
-
-
Collins, C.M.1
Yang, B.2
Yang, Q.X.3
Smith, M.B.4
-
4
-
-
0345073761
-
Threedimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head
-
Truong TK, Clymer BD, Chakeres DW, Schmalbrock P. Threedimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head. Magn. Reson. Imaging 2002; 20: 759-770.
-
(2002)
Magn. Reson. Imaging
, vol.20
, pp. 759-770
-
-
Truong, T.K.1
Clymer, B.D.2
Chakeres, D.W.3
Schmalbrock, P.4
-
5
-
-
0041491637
-
Calculation of electric fields induced by body and head motion in high-field MRI
-
Liu F, Zhao HW, Crozier S. Calculation of electric fields induced by body and head motion in high-field MRI. J. Magn. Reson. 2003; 161: 99-107.
-
(2003)
J. Magn. Reson.
, vol.161
, pp. 99-107
-
-
Liu, F.1
Zhao, H.W.2
Crozier, S.3
-
7
-
-
4243079824
-
Perturbation method for magnetic field calculations of nonconductive objects
-
Jenkinson M, Wilson JL, Jezzard P. Perturbation method for magnetic field calculations of nonconductive objects. Magn. Reson. Med. 2004; 52: 471-477.
-
(2004)
Magn. Reson. Med.
, vol.52
, pp. 471-477
-
-
Jenkinson, M.1
Wilson, J.L.2
Jezzard, P.3
-
8
-
-
20144364751
-
Application of a fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility
-
Marques JP, Bowtell R. Application of a fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility. Concepts in Magnetic Resonance Engineering Part B - Magnetic Resonance Engineering 2005; 25B: 65-78.
-
(2005)
Concepts in Magnetic Resonance Engineering Part B - Magnetic Resonance Engineering
, vol.25 B
, pp. 65-78
-
-
Marques, J.P.1
Bowtell, R.2
-
9
-
-
33846873463
-
Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance
-
Koch KM, Papademetris X, Rothman DL, de Graaf RA. Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance. Phys. Med. Biol. 2006; 51: 6381-6402.
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 6381-6402
-
-
Koch, K.M.1
Papademetris, X.2
Rothman, D.L.3
De Graaf, R.A.4
-
10
-
-
70849106055
-
Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets
-
Crozier S, Trakic A, Wang H, Liu F. Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, May 19-25, 2007, Berlin, p. 1098.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, May 19-25, 2007, Berlin
, pp. 1098
-
-
Crozier, S.1
Trakic, A.2
Wang, H.3
Liu, F.4
-
12
-
-
13444282105
-
The SIMRI project: A versatile and interactive MRI simulator
-
Benoit-Cattin H, Collowet G, Belaroussi, Saint-Jalmes H, Odet C. The SIMRI project: a versatile and interactive MRI simulator. J. Magn. Reson. 2005; 173: 97-115.
-
(2005)
J. Magn. Reson.
, vol.173
, pp. 97-115
-
-
Benoit-Cattin, H.1
Collowet, G.2
Belaroussi3
Saint-Jalmes, H.4
Odet, C.5
-
14
-
-
0035126320
-
On a possible mechanism for peripheral nerve stimulation during magnetic resonance imaging scans
-
Forbes LK, Crozier S. On a possible mechanism for peripheral nerve stimulation during magnetic resonance imaging scans. Phys. Med. Biol. 2001; 46: 591-608.
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 591-608
-
-
Forbes, L.K.1
Crozier, S.2
-
15
-
-
0036788387
-
Induction of electric fields due to gradient switching: A numerical approach
-
Brand M, Heid O. Induction of electric fields due to gradient switching: a numerical approach. Magn. Reson. Med. 2002; 48: 731-734.
-
(2002)
Magn. Reson. Med.
, vol.48
, pp. 731-734
-
-
Brand, M.1
Heid, O.2
-
16
-
-
0042664135
-
On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI
-
Liu F, Zhao W, Crozier S. On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRI. IEEE Trans. Biomed. Eng. 2003; 50: 804-811.
-
(2003)
IEEE Trans. Biomed. Eng.
, vol.50
, pp. 804-811
-
-
Liu, F.1
Zhao, W.2
Crozier, S.3
-
18
-
-
33744961733
-
Reducing peripheral nerve stimulation due to switched transverse field gradients using additional concomitant field coil
-
Bowtell R, Bencsik M, Bowley R. Reducing peripheral nerve stimulation due to switched transverse field gradients using additional concomitant field coil. In Proceedings of the 11th Annual Meeting of ISMRM, Toronto, 2003, p. 2424.
-
Proceedings of the 11th Annual Meeting of ISMRM, Toronto, 2003
, pp. 2424
-
-
Bowtell, R.1
Bencsik, M.2
Bowley, R.3
-
19
-
-
33744955709
-
Calculations of the complete electric field within a loaded gradient coil
-
Mao W, Chronik BA, Feldman RE, Smith MB, Collins CM. Calculations of the complete electric field within a loaded gradient coil. Magn. Reson. Med. 2006; 55: 1424-1432.
-
(2006)
Magn. Reson. Med.
, vol.55
, pp. 1424-1432
-
-
Mao, W.1
Chronik, B.A.2
Feldman, R.E.3
Smith, M.B.4
Collins, C.M.5
-
20
-
-
70849107434
-
Modelling regulatory compliance of occupationally exposed MRI workers during gradient pulsing
-
Crozier S,Wang H, Trakic A, Liu F. Modelling regulatory compliance of occupationally exposed MRI workers during gradient pulsing. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, May 19-25, 2007, Berlin, p. 1089.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, May 19-25, 2007, Berlin
, pp. 1089
-
-
Crozier, S.1
Wang, H.2
Trakic, A.3
Liu, F.4
-
21
-
-
0037712877
-
Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils
-
Chronik BA, Ramachandran M. Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils. J. Magn. Reson. Imaging 2003; 17: 716-721.
-
(2003)
J. Magn. Reson. Imaging
, vol.17
, pp. 716-721
-
-
Chronik, B.A.1
Ramachandran, M.2
-
22
-
-
0018190215
-
RF magnetic field penetration, phase shift and power dissipation in biological tissue: Implications for NMR imaging
-
Bottomley PA, Andrew ER. RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. Phys. Med. Biol. 1978; 23: 630-643.
-
(1978)
Phys. Med. Biol.
, vol.23
, pp. 630-643
-
-
Bottomley, P.A.1
Andrew, E.R.2
-
23
-
-
0000132799
-
The sensitivity of the zeugmatographic experiment involving human samples
-
Hoult DI, Lauterbur PC. The sensitivity of the zeugmatographic experiment involving human samples. J. Magn. Reson. 1979; 34: 425-433.
-
(1979)
J. Magn. Reson.
, vol.34
, pp. 425-433
-
-
Hoult, D.I.1
Lauterbur, P.C.2
-
26
-
-
0001184266
-
Comparison of linear and circular polarization for magnetic resonance imaging
-
Glover GH, Hayes CE, Pelc NJ, Edelstein WA, Mueller OM, Hart HR, Hardy CJ, O'Donnell M, Barber WD. Comparison of linear and circular polarization for magnetic resonance imaging. J. Magn. Reson. 1985; 64: 255-270.
-
(1985)
J. Magn. Reson.
, vol.64
, pp. 255-270
-
-
Glover, G.H.1
Hayes, C.E.2
Pelc, N.J.3
Edelstein, W.A.4
Mueller, O.M.5
Hart, H.R.6
Hardy, C.J.7
O'Donnell, M.8
Barber, W.D.9
-
27
-
-
0026340831
-
Electromagnetic fields of surface coil in vivo NMR at high frequencies
-
Keltner JR, Carlson JW, Roos MS, Wong TS, Wong TL, Budinger TF. Electromagnetic fields of surface coil in vivo NMR at high frequencies. Magn. Reson. Med. 1991; 22: 467-480.
-
(1991)
Magn. Reson. Med.
, vol.22
, pp. 467-480
-
-
Keltner, J.R.1
Carlson, J.W.2
Roos, M.S.3
Wong, T.S.4
Wong, T.L.5
Budinger, T.F.6
-
28
-
-
0345748112
-
Calculation of electromagnetic field of an MRI antenna loaded by a body
-
Ochi H, Yamamoto E, Sawaya K, Adachi S. Calculation of electromagnetic field of an MRI antenna loaded by a body. In Book of Abstracts, 11th Annual Meeting, Society of Magnetic Resonance in Medicine, Berlin, 1992; p. 4021.
-
Book of Abstracts, 11th Annual Meeting, Society of Magnetic Resonance in Medicine, Berlin, 1992
, pp. 4021
-
-
Ochi, H.1
Yamamoto, E.2
Sawaya, K.3
Adachi, S.4
-
29
-
-
0027177693
-
Predicting RF field penetration in heterogeneous bodies using a 3D finite element approach: Preliminary results
-
Petropolous LS, Haacke EM, Brown RW, Boerner E. Predicting RF field penetration in heterogeneous bodies using a 3D finite element approach: preliminary results. Magn. Reson. Med. 1993; 30: 366-372.
-
(1993)
Magn. Reson. Med.
, vol.30
, pp. 366-372
-
-
Petropolous, L.S.1
Haacke, E.M.2
Brown, R.W.3
Boerner, E.4
-
30
-
-
0027716022
-
Radio frequency eddy current losses for an annular conductor in MRI: Theory and applications
-
McRobbie DW. Radio frequency eddy current losses for an annular conductor in MRI: theory and applications. Med. Phys. 1993; 20: 1555-1560.
-
(1993)
Med. Phys.
, vol.20
, pp. 1555-1560
-
-
McRobbie, D.W.1
-
32
-
-
4243556316
-
Standing waves in uniform water phantoms
-
Tofts PS. Standing waves in uniform water phantoms. J. Magn. Reson. 1994; 104B: 143-147.
-
(1994)
J. Magn. Reson.
, vol.104 B
, pp. 143-147
-
-
Tofts, P.S.1
-
33
-
-
0036240672
-
Analysis of Wave Behavior in Dielectric Samples at High Field
-
Yang QX, Wang JH, Collins CM, Smith MB, Zhang X, Liu H, Michaeli S, Zhu X-H, Adriany G, Vaughan JT, Anderson P, Ugurbil K, Chen W. Analysis of Wave Behavior in Dielectric Samples at High Field. Magn. Reson. Med. 2002; 47: 982-989.
-
(2002)
Magn. Reson. Med.
, vol.47
, pp. 982-989
-
-
Yang, Q.X.1
Wang, J.H.2
Collins, C.M.3
Smith, M.B.4
Zhang, X.5
Liu, H.6
Michaeli, S.7
Zhu, X.-H.8
Adriany, G.9
Vaughan, J.T.10
Anderson, P.11
Ugurbil, K.12
Chen, W.13
-
34
-
-
70849107750
-
3D numerical modeling of high frequency volume coils for clinical NMR
-
McDuffie JH, Harrison JG, Pohost GM, Vaughan JT. 3D numerical modeling of high frequency volume coils for clinical NMR. In Proceedings of the Society of Magnetic Resonance, 3rd Scientific Meeting, Nice, 1995; p. 185.
-
Proceedings of the Society of Magnetic Resonance, 3rd Scientific Meeting, Nice, 1995
, pp. 185
-
-
McDuffie, J.H.1
Harrison, J.G.2
Pohost, G.M.3
Vaughan, J.T.4
-
36
-
-
0031027330
-
An FEM approach for the characterization of the field homogeneity at high field
-
Guclu C, Kashmar G, Hacinliyan A, Nalcioglu O. An FEM approach for the characterization of the field homogeneity at high field. Magn. Reson. Med. 1997; 37: 76-83.
-
(1997)
Magn. Reson. Med.
, vol.37
, pp. 76-83
-
-
Guclu, C.1
Kashmar, G.2
Hacinliyan, A.3
Nalcioglu, O.4
-
37
-
-
0031083035
-
1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field
-
1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field. J. Magn. Reson. 1997; 125: 72-83.
-
(1997)
J. Magn. Reson.
, vol.125
, pp. 72-83
-
-
Singerman, R.W.1
Denison, T.J.2
Wen, H.3
Balaban, R.S.4
-
38
-
-
0031733095
-
A numerical study of radiofrequency deposition in a spherical phantom using surface coils
-
Strilka RJ, Li S, Martin JT, Collins CM, Smith MB. A numerical study of radiofrequency deposition in a spherical phantom using surface coils. Magn. Reson. Imaging 1998; 16: 787-798.
-
(1998)
Magn. Reson. Imaging
, vol.16
, pp. 787-798
-
-
Strilka, R.J.1
Li, S.2
Martin, J.T.3
Collins, C.M.4
Smith, M.B.5
-
39
-
-
0031884051
-
Ultimate intrinsic signal-to-noise ratio in MRI
-
Ocali O, Atalar E. Ultimate intrinsic signal-to-noise ratio in MRI. Magn. Reson. Imaging 1998; 39: 462-473.
-
(1998)
Magn. Reson. Imaging
, vol.39
, pp. 462-473
-
-
Ocali, O.1
Atalar, E.2
-
40
-
-
0033945956
-
The sensitivity and power deposition of the high field imaging experiment
-
Hoult DI. The sensitivity and power deposition of the high field imaging experiment. J. Magn. Reson. Imaging 2000; 12: 46-67.
-
(2000)
J. Magn. Reson. Imaging
, vol.12
, pp. 46-67
-
-
Hoult, D.I.1
-
41
-
-
0036238849
-
Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
-
Collins CM, Yang QX, Wang JH, Zhu X-H, Adriany G, Michaeli S, Vaughan JT, Zhang X, Liu H, Anderson P, Ugurbil K, Smith MB, Chen W. Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz. Magn. Reson. Med. 2003; 47: 1026-1028.
-
(2003)
Magn. Reson. Med.
, vol.47
, pp. 1026-1028
-
-
Collins, C.M.1
Yang, Q.X.2
Wang, J.H.3
Zhu, X.-H.4
Adriany, G.5
Michaeli, S.6
Vaughan, J.T.7
Zhang, X.8
Liu, H.9
Anderson, P.10
Ugurbil, K.11
Smith, M.B.12
Chen, W.13
-
42
-
-
7544231110
-
Parallel imaging performance as a function of field strength - An experimental investigation using electrodynamic scaling
-
Wiesinger F, Van de Moortele P-F, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP. Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling. Magn. Reson. Med. 2004; 52: 953-964.
-
(2004)
Magn. Reson. Med.
, vol.52
, pp. 953-964
-
-
Wiesinger, F.1
Van De Moortele, P.-F.2
Adriany, G.3
De Zanche, N.4
Ugurbil, K.5
Pruessmann, K.P.6
-
43
-
-
12744262814
-
Central brightening due to constructive interference with, without, and despite dielectric resonance
-
Collins CM, Liu W, Schreiber W, Yang QX, Smith MB. Central brightening due to constructive interference with, without, and despite dielectric resonance. J. Magn. Reson. Imag. 2005; 21: 192-196.
-
(2005)
J. Magn. Reson. Imag.
, vol.21
, pp. 192-196
-
-
Collins, C.M.1
Liu, W.2
Schreiber, W.3
Yang, Q.X.4
Smith, M.B.5
-
44
-
-
70849117863
-
Toward understanding SAR patterns in the human head at high field (200 to 400 MHz) MRI with volume coils
-
th Scientific Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine, May 6-12, Seattle, Washington, 2006; p. 1390.
-
th Scientific Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine, May 6-12, Seattle, Washington, 2006
, pp. 1390
-
-
Wang, Z.1
Collins, C.M.2
Smith, M.B.3
-
45
-
-
79954748083
-
Electrodynamic constraints on minimum SAR in parallel excitation
-
Lattanzi R, Grant AK, Sodickson DK, Zhu Y. Electrodynamic constraints on minimum SAR in parallel excitation. In Joint Annual Meeting ISMRM-ESMRMB, May 19-25, Berlin, 2007; p. 675.
-
Joint Annual Meeting ISMRM-ESMRMB, May 19-25, Berlin, 2007
, pp. 675
-
-
Lattanzi, R.1
Grant, A.K.2
Sodickson, D.K.3
Zhu, Y.4
-
46
-
-
0032252606
-
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil
-
Collins CM, Li S, Smith MB. SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Magn. Reson. Med. 1998; 40: 847-856.
-
(1998)
Magn. Reson. Med.
, vol.40
, pp. 847-856
-
-
Collins, C.M.1
Li, S.2
Smith, M.B.3
-
47
-
-
70949098426
-
Optimization of RF coils for high field imaging: Why the head is different than symmetrical phantoms
-
Ibrahim TS. Optimization of RF coils for high field imaging: why the head is different than symmetrical phantoms. In ISMRM Twelfth Scientific Meeting, May 15-21, Kyoto, 2004; p. 1643.
-
ISMRM Twelfth Scientific Meeting, May 15-21, Kyoto, 2004
, pp. 1643
-
-
Ibrahim, T.S.1
-
48
-
-
70849100423
-
Finite element calculation of radiofrequency magnetic fields in simulated human organs
-
Smith MB, Ashtiani CN, Cendes ZJ, Williams GD, Martin JT. Finite element calculation of radiofrequency magnetic fields in simulated human organs. In Book of abstracts, SMRM Eighth Annual Meeting and Exhibition. 1989; p. 995.
-
Book of Abstracts, SMRM Eighth Annual Meeting and Exhibition. 1989
, pp. 995
-
-
Smith, M.B.1
Ashtiani, C.N.2
Cendes, Z.J.3
Williams, G.D.4
Martin, J.T.5
-
49
-
-
0027989884
-
High frequency volume coils for clinical NMR imaging and spectroscopy
-
Vaughan JT, Hetherington HP, Otu JO, Pan JW, Pohost GM. High frequency volume coils for clinical NMR imaging and spectroscopy. Magn. Reson. Imaging 1994; 32: 206-218.
-
(1994)
Magn. Reson. Imaging
, vol.32
, pp. 206-218
-
-
Vaughan, J.T.1
Hetherington, H.P.2
Otu, J.O.3
Pan, J.W.4
Pohost, G.M.5
-
50
-
-
0030709486
-
On the SAR and field inhomogeneity of birdcage coils loaded with the human head
-
Jin J, Chen J. On the SAR and field inhomogeneity of birdcage coils loaded with the human head. Magn. Reson. Med. 1997; 38: 953-963.
-
(1997)
Magn. Reson. Med.
, vol.38
, pp. 953-963
-
-
Jin, J.1
Chen, J.2
-
52
-
-
0030058959
-
Spatial distribution of high-frequency electromagnetic energy in human head during MRI: Numerical results and measurements
-
Simunic D, Wach P, Renhart W, Stollberger R. Spatial distribution of high-frequency electromagnetic energy in human head during MRI: numerical results and measurements. IEEE Trans. Biomed. Eng. 1996; 43: 88-94.
-
(1996)
IEEE Trans. Biomed. Eng.
, vol.43
, pp. 88-94
-
-
Simunic, D.1
Wach, P.2
Renhart, W.3
Stollberger, R.4
-
53
-
-
0029827185
-
Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications
-
Jin JM, Chen J, Chew WC, Gan H, Magin RL, Dimbylow PJ. Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications. Phys. Med. Biol. 1996; 41: 2719-2738.
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 2719-2738
-
-
Jin, J.M.1
Chen, J.2
Chew, W.C.3
Gan, H.4
Magin, R.L.5
Dimbylow, P.J.6
-
55
-
-
0035088728
-
Signal-to-noise ratio and absorbed power as functions of main magnetic field strength and definition of "90°" RF pulse for the head in the birdcage coil
-
Collins CM, Smith MB. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength and definition of "90°" RF pulse for the head in the birdcage coil. Magn. Reson. Med. 2001; 45: 684-691.
-
(2001)
Magn. Reson. Med.
, vol.45
, pp. 684-691
-
-
Collins, C.M.1
Smith, M.B.2
-
56
-
-
0035685766
-
Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator
-
Ibrahim TS, Lee R, Baertlein BA, Abduljalil AM, Zhu H, Robitaille PL. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn. Reson. Imaging 2001; 19: 1339-1347.
-
(2001)
Magn. Reson. Imaging
, vol.19
, pp. 1339-1347
-
-
Ibrahim, T.S.1
Lee, R.2
Baertlein, B.A.3
Abduljalil, A.M.4
Zhu, H.5
Robitaille, P.L.6
-
57
-
-
84890006459
-
New high resolution head model for accurate electromagnetic field computation
-
Angelone LM, Tulloch S, Wiggins G, Iwaki S, Makris N, Bonmassar G. New high resolution head model for accurate electromagnetic field computation. In: Proceedings of the International Society of Magnetic Resonance in Medicine 2005; 13: 881.
-
(2005)
Proceedings of the International Society of Magnetic Resonance in Medicine
, vol.13
, pp. 881
-
-
Angelone, L.M.1
Tulloch, S.2
Wiggins, G.3
Iwaki, S.4
Makris, N.5
Bonmassar, G.6
-
58
-
-
0025040158
-
Magnetic resonance imaging: Calculation of rates of energy absorption by a human-torso model
-
Grandolfo M, Vecchia P, Gandhi OP. Magnetic resonance imaging: calculation of rates of energy absorption by a human-torso model. Bioelectromagnetics 1990; 11: 117-128 (Pubitemid 20307843)
-
(1990)
Bioelectromagnetics
, vol.11
, Issue.2
, pp. 117-128
-
-
Grandolfo, M.1
Vecchia, P.2
Gandhi, O.P.3
-
59
-
-
0035088714
-
1 distribution, SNR, and SAR for a surface coil against an anatomically-accurate human body model
-
1 distribution, SNR, and SAR for a surface coil against an anatomically-accurate human body model. Magn. Reson. Med. 2001; 45: 692-699.
-
(2001)
Magn. Reson. Med.
, vol.45
, pp. 692-699
-
-
Collins, C.M.1
Smith, M.B.2
-
60
-
-
26044442541
-
Calculations of B1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHz
-
Liu W, Collins CM, Smith MB. Calculations of B1 distribution, specific energy absorption rate, and intrinsic signal-to-noise ratio for a body-size birdcage coil loaded with different human subjects at 64 and 128 MHz. Appl. Magn. Reson. 2005; 29: 5-18.
-
(2005)
Appl. Magn. Reson.
, vol.29
, pp. 5-18
-
-
Liu, W.1
Collins, C.M.2
Smith, M.B.3
-
61
-
-
12244304888
-
Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils
-
Alecci M, Collins CM, Wilson J, LiuW, Smith MB, Jezzard P. Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils. Magn. Reson. Med. 2003; 49: 363-370.
-
(2003)
Magn. Reson. Med.
, vol.49
, pp. 363-370
-
-
Alecci, M.1
Collins, C.M.2
Wilson, J.3
Liu, W.4
Smith, M.B.5
Jezzard, P.6
-
63
-
-
0345748112
-
Calculation of electromagnetic field of an MRI antenna loaded by a body
-
Ochi H, Yamamoto E, Sawaya K, Adachi S. Calculation of electromagnetic field of an MRI antenna loaded by a body. In Book of Abstracts, 11th Annual Meeting, Society of Magnetic Resonance in Medicine, Berlin, 1992; p. 4021.
-
Book of Abstracts, 11th Annual Meeting, Society of Magnetic Resonance in Medicine, Berlin, 1992
, pp. 4021
-
-
Ochi, H.1
Yamamoto, E.2
Sawaya, K.3
Adachi, S.4
-
64
-
-
70849083851
-
Analysis of MRI antenna inside an RF shield using moment method
-
Ochi H, Yamamoto E, Sawaya K, Adachi S. Analysis of MRI antenna inside an RF shield using moment method. In Proceedings of the Society of Magnetic Resonance in Medicine, 12th Annual Meeting, New York, 1993; p. 1356.
-
Proceedings of the Society of Magnetic Resonance in Medicine, 12th Annual Meeting, New York, 1993
, pp. 1356
-
-
Ochi, H.1
Yamamoto, E.2
Sawaya, K.3
Adachi, S.4
-
65
-
-
1542753791
-
Three-dimensional full wave solution of MRI radio frequency resonator
-
Yang QX, Maramis H, Li S, Smith MB. Three-dimensional full wave solution of MRI radio frequency resonator. In Proceedings of the Society of Magnetic Resonance, 2nd Annual Meeting, San Francisco, 1994; p. 1110.
-
Proceedings of the Society of Magnetic Resonance, 2nd Annual Meeting, San Francisco, 1994
, pp. 1110
-
-
Yang, Q.X.1
Maramis, H.2
Li, S.3
Smith, M.B.4
-
68
-
-
0033770165
-
Computational analysis of the high pass birdcage resonator: Finite difference time domain simulations for high-field MRI
-
Ibrahim TS, Lee R, Baertlein BA, Yu Y, Robitaille PML. Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI. Magn. Reson. Imaging 2000; 18: 835-843.
-
(2000)
Magn. Reson. Imaging
, vol.18
, pp. 835-843
-
-
Ibrahim, T.S.1
Lee, R.2
Baertlein, B.A.3
Yu, Y.4
Robitaille, P.M.L.5
-
69
-
-
0034962138
-
7 T vs. 4 T: RF power, homogeneity, and signal-to-noise comparison in head images
-
Vaughan JT, Garwood M, Collins CM, Liu W, DelaBarre L, Adriany G, Andersen P, Merkle H, Goebel R, Smith MB, Ugurbil K. 7 T vs. 4 T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn. Reson. Med. 2001; 46: 24-30.
-
(2001)
Magn. Reson. Med.
, vol.46
, pp. 24-30
-
-
Vaughan, J.T.1
Garwood, M.2
Collins, C.M.3
Liu, W.4
DelaBarre, L.5
Adriany, G.6
Andersen, P.7
Merkle, H.8
Goebel, R.9
Smith, M.B.10
Ugurbil, K.11
-
71
-
-
70849090187
-
Radiofrequency field calculations for high field MRI
-
Robitaille PML, Berliner L (eds). Springer: New York
-
Collins CM. Radiofrequency field calculations for high field MRI. In Ultra High Field Magnetic Resonance Imaging, Robitaille PML, Berliner L (eds). Springer: New York, 2006; 209-233.
-
(2006)
Ultra High Field Magnetic Resonance Imaging
, pp. 209-233
-
-
Collins, C.M.1
-
72
-
-
34748907869
-
Large-scale simulations including a human-body model for MRI
-
Vogel MH, Kleihorst RP. Large-scale simulations including a human-body model for MRI. In IEEE MTT-S 2007 International Microwave Symposium Technical Program, Honolulu, June 3-8, 2007; p. 1010.
-
IEEE MTT-S 2007 International Microwave Symposium Technical Program, Honolulu, June 3-8, 2007
, pp. 1010
-
-
Vogel, M.H.1
Kleihorst, R.P.2
-
73
-
-
19544387778
-
Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest: Theoretical considerations
-
Li BK, Liu F, Crozier S. Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest: theoretical considerations. Magn. Reson. Med. 2005; 53: 1251-1257.
-
(2005)
Magn. Reson. Med.
, vol.53
, pp. 1251-1257
-
-
Li, B.K.1
Liu, F.2
Crozier, S.3
-
74
-
-
0034405181
-
The principle of reciprocity in signal strength calculations - A mathematical guide
-
Hoult DI. The principle of reciprocity in signal strength calculations - a mathematical guide. Concepts in Magnetic Resonance 2000; 12: 173-187.
-
(2000)
Concepts in Magnetic Resonance
, vol.12
, pp. 173-187
-
-
Hoult, D.I.1
-
75
-
-
24144440068
-
Analytical approach to the MR signal
-
Ibrahim TS. Analytical approach to the MR signal. Magn. Reson. Med. 2005; 54: 677-682.
-
(2005)
Magn. Reson. Med.
, vol.54
, pp. 677-682
-
-
Ibrahim, T.S.1
-
76
-
-
28444487453
-
Combination of optimized transmit arrays and some parallel imaging reconstruction methods can yield homogeneous images at very high frequencies
-
Collins CM, Liu W, Swift BJ, Smith MB. Combination of optimized transmit arrays and some parallel imaging reconstruction methods can yield homogeneous images at very high frequencies. Magn. Reson. Med. 2005; 54: 1327-1332.
-
(2005)
Magn. Reson. Med.
, vol.54
, pp. 1327-1332
-
-
Collins, C.M.1
Liu, W.2
Swift, B.J.3
Smith, M.B.4
-
78
-
-
36149010109
-
Thermal agitation of electric charge in conductors
-
Nyquist H. Thermal agitation of electric charge in conductors. Phys. Rev. 1928; 32: 110-113.
-
(1928)
Phys. Rev.
, vol.32
, pp. 110-113
-
-
Nyquist, H.1
-
79
-
-
46549092488
-
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
-
Hayes CE, EdelsteinWA, Schenck JF, Mueller OM, Eash M. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T. J. Magn. Reson. 1985; 63: 622-628.
-
(1985)
J. Magn. Reson.
, vol.63
, pp. 622-628
-
-
Hayes, C.E.1
Edelstein, W.A.2
Schenck, J.F.3
Mueller, O.M.4
Eash, M.5
-
80
-
-
28444473098
-
B1 interferences and spatial phase patterns at 7 tesla with a head transceiver array coil
-
Van de Moortele P-F, Akgun C, Adriany G, Moeller S, Ritter J, Collins CM, Smith MB, Vaughan JT, Ugurbil K. B1 interferences and spatial phase patterns at 7 tesla with a head transceiver array coil. Magn. Reson. Med. 2005; 54: 1503-1518.
-
(2005)
Magn. Reson. Med.
, vol.54
, pp. 1503-1518
-
-
Van De Moortele, P.-F.1
Akgun, C.2
Adriany, G.3
Moeller, S.4
Ritter, J.5
Collins, C.M.6
Smith, M.B.7
Vaughan, J.T.8
Ugurbil, K.9
-
81
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn. Reson. Med. 1990; 16: 192-225.
-
(1990)
Magn. Reson. Med.
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
82
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Ultra-fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays. Magn. Reson. Med. 1997; 38: 591-603.
-
(1997)
Magn. Reson. Med.
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
84
-
-
0033772492
-
Partially parallel imaging with localized sensitivities (PILS)
-
Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A. Partially parallel imaging with localized sensitivities (PILS). Magn. Reson. Med. 2000; 44: 602-609.
-
(2000)
Magn. Reson. Med.
, vol.44
, pp. 602-609
-
-
Griswold, M.A.1
Jakob, P.M.2
Nittka, M.3
Goldfarb, J.W.4
Haase, A.5
-
85
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn. Reson. Med. 2002; 47: 1202-1210.
-
(2002)
Magn. Reson. Med.
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
86
-
-
0034845169
-
A generalized approach to parallel magnetic resonance imaging
-
Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med. Phys. 2001; 28: 1629-1643.
-
(2001)
Med. Phys.
, vol.28
, pp. 1629-1643
-
-
Sodickson, D.K.1
McKenzie, C.A.2
-
87
-
-
33646383376
-
Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: A modeling study
-
Li BK, Xu B, Liu F, Crozier S. Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: a modeling study. Concepts Magnetic Resonance Part B - Magnetic Resonance Engineering 2006; 29B: 95-105.
-
(2006)
Concepts Magnetic Resonance Part B - Magnetic Resonance Engineering
, vol.29 B
, pp. 95-105
-
-
Li, B.K.1
Xu, B.2
Liu, F.3
Crozier, S.4
-
88
-
-
33846804494
-
Proposed radiofrequency phased-array excitation scheme for homogenous and localized 7-Tesla whole-body imaging based on full-wave numerical simulations
-
Abraham R, Ibrahim TS. Proposed radiofrequency phased-array excitation scheme for homogenous and localized 7-Tesla whole-body imaging based on full-wave numerical simulations. Magn. Reson. Med. 2007; 57: 235-242.
-
(2007)
Magn. Reson. Med.
, vol.57
, pp. 235-242
-
-
Abraham, R.1
Ibrahim, T.S.2
-
89
-
-
33847718735
-
Array-optimized composite pulses for excellent whole-brain homogeneity in high field MRI
-
Collins CM,Wang Z, MaoW, Fang J, LiuW, Smith MB. Array-optimized composite pulses for excellent whole-brain homogeneity in high field MRI. Magn. Reson. Med. 2007; 57: 470-474.
-
(2007)
Magn. Reson. Med.
, vol.57
, pp. 470-474
-
-
Collins, C.M.1
Wang, Z.2
Mao, W.3
Fang, J.4
Liu, W.5
Smith, M.B.6
-
91
-
-
34547928157
-
A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission
-
Xu D, King KF, Zhu Y, McKinnon GC, Liang Z-P. A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission. Magn. Reson. Med. 2007; 58: 326-334.
-
(2007)
Magn. Reson. Med.
, vol.58
, pp. 326-334
-
-
Xu, D.1
King, K.F.2
Zhu, Y.3
McKinnon, G.C.4
Liang, Z.-P.5
-
92
-
-
51649086514
-
SAR reduction in transmit SENSE using adapted excitation k-space trajectories
-
Wu X, Akgun C, Vaughan JT, Ugurbil K, Van de Moortele P-F. SAR reduction in transmit SENSE using adapted excitation k-space trajectories. In Proceedings of the Joint Annual Meeting ISMRM- ESMRMB, Berlin, May 19-25, 2007; p. 673.
-
Proceedings of the Joint Annual Meeting ISMRM- ESMRMB, Berlin, May 19-25, 2007
, pp. 673
-
-
Wu, X.1
Akgun, C.2
Vaughan, J.T.3
Ugurbil, K.4
Van De Moortele, P.-F.5
-
93
-
-
77955321240
-
SAR reduction for parallel transmission using VERSE and K-space filtering
-
Graesslin I, Biederer S, Schweser F, Zimmermann K-H, Katscher U, Börnert P. SAR reduction for parallel transmission using VERSE and K-space filtering. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 674.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 674
-
-
Graesslin, I.1
Biederer, S.2
Schweser, F.3
Zimmermann, K.-H.4
Katscher, U.5
Börnert, P.6
-
95
-
-
51649087790
-
RF shimming considering both excitation homogeneity and SAR
-
Wang Z, Oh S-H, Smith MB, Collins CM. RF shimming considering both excitation homogeneity and SAR. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1022.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1022
-
-
Wang, Z.1
Oh, S.-H.2
Smith, M.B.3
Collins, C.M.4
-
96
-
-
79954799003
-
A novel RF head coil for 7 T homogeneity and parallel imaging applications
-
Akgun CE, Snyder CJ, DelaBarre L, Tian J, Van de Moortele P-F, Moeller S, Ugurbil K, Vaughan JT. A novel RF head coil for 7 T homogeneity and parallel imaging applications. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1031.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1031
-
-
Akgun, C.E.1
Snyder, C.J.2
DelaBarre, L.3
Tian, J.4
Van De Moortele, P.-F.5
Moeller, S.6
Ugurbil, K.7
Vaughan, J.T.8
-
98
-
-
79954745233
-
Real-time SAR monitoring to ensure patient safety for parallel transmission systems
-
Graesslin I, Biederer S, Falaggis K, Vernickel P, Dingemans H, Mens G, Roeschmann P, Leussler C, Zhai Z, Morich M, Katscher U. Real-time SAR monitoring to ensure patient safety for parallel transmission systems. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1086.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1086
-
-
Graesslin, I.1
Biederer, S.2
Falaggis, K.3
Vernickel, P.4
Dingemans, H.5
Mens, G.6
Roeschmann, P.7
Leussler, C.8
Zhai, Z.9
Morich, M.10
Katscher, U.11
-
99
-
-
73349106624
-
A conservative method for ensuring safety within transmit arrays
-
Collins CM, Wang Z, Smith MB. A conservative method for ensuring safety within transmit arrays. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1092.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1092
-
-
Collins, C.M.1
Wang, Z.2
Smith, M.B.3
-
100
-
-
70849117581
-
Array-optimized composite pulse for homogeneous whole-brain inversion in high field MRI
-
Oh S-H, Wang Z, Smith MB, Collins CM. Array-optimized composite pulse for homogeneous whole-brain inversion in high field MRI. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1692.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1692
-
-
Oh, S.-H.1
Wang, Z.2
Smith, M.B.3
Collins, C.M.4
-
101
-
-
77955335890
-
Pulse design methods for reduction of specific absorption rate in parallel RF excitation
-
Zelinski AC, Setsompop K, Alagappan V, Gagoski BA, Angelone LM, Bonmassar G, Fontius U, Schmitt F, Adalsteinsson E, Wald LL. pulse design methods for reduction of specific absorption rate in parallel RF excitation. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1698.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1698
-
-
Zelinski, A.C.1
Setsompop, K.2
Alagappan, V.3
Gagoski, B.A.4
Angelone, L.M.5
Bonmassar, G.6
Fontius, U.7
Schmitt, F.8
Adalsteinsson, E.9
Wald, L.L.10
-
102
-
-
51649124376
-
Designing RF pulses with optimal specific absorption rate (SAR) characteristics and exploring excitation fidelity, SAR and pulse duration tradeoffs
-
Zelinski AC, Goyal VK, Angelone L, Bonmassar B, Wald LL, Adalsteinsson E. Designing RF pulses with optimal specific absorption rate (SAR) characteristics and exploring excitation fidelity, SAR and pulse duration tradeoffs. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 1699.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 1699
-
-
Zelinski, A.C.1
Goyal, V.K.2
Angelone, L.3
Bonmassar, B.4
Wald, L.L.5
Adalsteinsson, E.6
-
104
-
-
33845271477
-
9.4 T human MRI: Preliminary results
-
Vaughan JT, DelaBarre L, Snyder C, Tian J, Akgun C, Shrivastava D, Liu W, Olson C, Adriany G, Strupp J, Andersen P, Gopinath A, van de Moortele P-F, Garwood M, Ugurbil K. 9.4 T human MRI: preliminary results. Magn. Reson. Med. 2007; 56: 1274-1282.
-
(2007)
Magn. Reson. Med.
, vol.56
, pp. 1274-1282
-
-
Vaughan, J.T.1
DelaBarre, L.2
Snyder, C.3
Tian, J.4
Akgun, C.5
Shrivastava, D.6
Liu, W.7
Olson, C.8
Adriany, G.9
Strupp, J.10
Andersen, P.11
Gopinath, A.12
Van De Moortele, P.-F.13
Garwood, M.14
Ugurbil, K.15
-
105
-
-
38949137883
-
Stripline/TEM transceiver array for 7 T body imaging
-
Snyder CJ, DelaBarre L, Van de Moortele P-F, Snyder ALL, Akgun C, Tian J, Metzger G, Ugurbil K, Vaughan JT. Stripline/TEM transceiver array for 7 T body imaging. In Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007; p. 164.
-
Proceedings of the Joint Annual Meeting ISMRM-ESMRMB, Berlin, May 19-25, 2007
, pp. 164
-
-
Snyder, C.J.1
DelaBarre, L.2
Van De Moortele, P.-F.3
Snyder, A.L.L.4
Akgun, C.5
Tian, J.6
Metzger, G.7
Ugurbil, K.8
Vaughan, J.T.9
-
107
-
-
0041326692
-
Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: A study at 64 MHz in a magnetic resonance imaging coil
-
Collins CM, Smith MB. Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: a study at 64 MHz in a magnetic resonance imaging coil. J. Magn. Reson. Imaging 2003; 18: 383-388.
-
(2003)
J. Magn. Reson. Imaging
, vol.18
, pp. 383-388
-
-
Collins, C.M.1
Smith, M.B.2
-
108
-
-
2442570617
-
Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
-
Collins CM, Liu W, Wang JH, Gruetter R, Vaughan JT, Ugurbil K, Smith MB. Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz. J. Magn. Reson. Imaging 2004; 19: 650-656.
-
(2004)
J. Magn. Reson. Imaging
, vol.19
, pp. 650-656
-
-
Collins, C.M.1
Liu, W.2
Wang, J.H.3
Gruetter, R.4
Vaughan, J.T.5
Ugurbil, K.6
Smith, M.B.7
-
109
-
-
33645766940
-
Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy
-
Hand JW, Li Y, Thomas EL, Rutherford MA, Hajnal JV. Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy. Magn. Reson. Med. 2006; 55: 883-893.
-
(2006)
Magn. Reson. Med.
, vol.55
, pp. 883-893
-
-
Hand, J.W.1
Li, Y.2
Thomas, E.L.3
Rutherford, M.A.4
Hajnal, J.V.5
-
110
-
-
33645761295
-
Numerical evaluation of B1-field and SAR for heterogeneous and homogeneous body model
-
th Scientific meeting of the International Society for Magnetic Resonance in Medicine, Kyoto, 2004; p. 666.
-
th Scientific Meeting of the International Society for Magnetic Resonance in Medicine, Kyoto, 2004
, pp. 666
-
-
Zhai, Z.1
DeMeester, G.D.2
Morich, M.A.3
Shvartsman, S.M.4
Kleihorst, R.P.5
-
111
-
-
3242718767
-
Numerical evaluation of heating of human head due to magnetic resonance image
-
Nguyen UD, Brown JS, Chang IA, Krycia J, Mirotznik MS. Numerical evaluation of heating of human head due to magnetic resonance image. IEEE Trans. Biomed. Eng. 2004; 51: 1301-1309.
-
(2004)
IEEE Trans. Biomed. Eng.
, vol.51
, pp. 1301-1309
-
-
Nguyen, U.D.1
Brown, J.S.2
Chang, I.A.3
Krycia, J.4
Mirotznik, M.S.5
-
112
-
-
0033945857
-
SAR and temperature changes in the leg due to an RF decoupling coil at frequencies between 64 and 213 MHz
-
Hand JW, Lagendijk JJW, Hajnal JV, Lau RW, Young IR. SAR and temperature changes in the leg due to an RF decoupling coil at frequencies between 64 and 213 MHz. J. Magn. Reson. Imag. 2000; 12: 68-74.
-
(2000)
J. Magn. Reson. Imag.
, vol.12
, pp. 68-74
-
-
Hand, J.W.1
Lagendijk, J.J.W.2
Hajnal, J.V.3
Lau, R.W.4
Young, I.R.5
-
113
-
-
0032765213
-
Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil
-
Hand JW, Lau RW, Lagendijk JJW, Ling J, Burl M, Young IR. Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil. J. Magn. Reson. Imaging 1999; 42: 183-192.
-
(1999)
J. Magn. Reson. Imaging
, vol.42
, pp. 183-192
-
-
Hand, J.W.1
Lau, R.W.2
Lagendijk, J.J.W.3
Ling, J.4
Burl, M.5
Young, I.R.6
-
114
-
-
33847735550
-
Evaluations of specific absorption rate and temperature increase within pregnant female models in magnetic resonance imaging birdcage coils
-
Wu DG, Shamsi S, Chen J, Kainz W. Evaluations of specific absorption rate and temperature increase within pregnant female models in magnetic resonance imaging birdcage coils. IEEE Trans. Microw. Theory Tech. 2006; 54: 4472-4478.
-
(2006)
IEEE Trans. Microw. Theory Tech.
, vol.54
, pp. 4472-4478
-
-
Wu, D.G.1
Shamsi, S.2
Chen, J.3
Kainz, W.4
-
115
-
-
34548864083
-
Evaluation of MR-induced hot spots for different temporal SAR modes using a time-dependant finite-difference method with explicit temperature gradient treatment
-
Nadobny J, Szimtenings M, Diehl D, Stetter E, Brinker G, Wust P. Evaluation of MR-induced hot spots for different temporal SAR modes using a time-dependant finite-difference method with explicit temperature gradient treatment. IEEE Trans. Biomed. Eng. 2007; 54: 1837-1850.
-
(2007)
IEEE Trans. Biomed. Eng.
, vol.54
, pp. 1837-1850
-
-
Nadobny, J.1
Szimtenings, M.2
Diehl, D.3
Stetter, E.4
Brinker, G.5
Wust, P.6
|