-
1
-
-
0024020391
-
Spectroscopy and imaging with a 4 tesla whole-body system
-
Bomsdorf H, Helzel T, Hunz D, Roschmann P, Tschendel O, Weiland J. Spectroscopy and imaging with a 4 tesla whole-body system. NMR Biomed 1988;1:151-158.
-
(1988)
NMR Biomed
, vol.1
, pp. 151-158
-
-
Bomsdorf, H.1
Helzel, T.2
Hunz, D.3
Roschmann, P.4
Tschendel, O.5
Weiland, J.6
-
2
-
-
0025378418
-
In vivo magnetic resonance imaging and spectroscopy of humans with a 4T whole-body magnet
-
Barfuss H, Fischer H, Hentschel D, et al. In vivo magnetic resonance imaging and spectroscopy of humans with a 4T whole-body magnet. NMR Biomed 1990;3:31-45.
-
(1990)
NMR Biomed
, vol.3
, pp. 31-45
-
-
Barfuss, H.1
Fischer, H.2
Hentschel, D.3
-
3
-
-
0034962138
-
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
-
Vaughan JT, Garwood M, Collins CM, et al. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med 2001;46:24-30.
-
(2001)
Magn Reson Med
, vol.46
, pp. 24-30
-
-
Vaughan, J.T.1
Garwood, M.2
Collins, C.M.3
-
4
-
-
0035006349
-
Robitaille PM-L. Dielectric resonances and B1 field inhomogeneity in UHFMRI: Computational analysis and experimental findings
-
Ibrahim T, Lee R, Abduljalil AM, Baertlein BA, Robitaille PM-L. Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings. Magn Reson Imaging 2001;19:219-226.
-
(2001)
Magn Reson Imaging
, vol.19
, pp. 219-226
-
-
Ibrahim, T.1
Lee, R.2
Abduljalil, A.M.3
Baertlein, B.A.4
-
5
-
-
0004442520
-
Role of B1 eigenfields of dielectric objects in highfield MRI
-
Denver
-
Roschmann P. Role of B1 eigenfields of dielectric objects in highfield MRI. In: Proceedings of the 8th Annual Meeting of ISMRM, Denver, 2000. p 151.
-
(2000)
Proceedings of the 8th Annual Meeting of ISMRM
, pp. 151
-
-
Roschmann, P.1
-
7
-
-
1242264843
-
Image brightening in samples of high dielectric constant
-
Tropp J. Image brightening in samples of high dielectric constant. J Magn Reson 2004;167:12-24.
-
(2004)
J Magn Reson
, vol.167
, pp. 12-24
-
-
Tropp, J.1
-
8
-
-
0036240672
-
Analysis of wave behavior in dielectric sample at high field
-
Yang QX, Wang JH, Collins CM, et al. Analysis of wave behavior in dielectric sample at high field. Magn Reson Med 2002;47:982-989.
-
(2002)
Magn Reson Med
, vol.47
, pp. 982-989
-
-
Yang, Q.X.1
Wang, J.H.2
Collins, C.M.3
-
9
-
-
0031733095
-
A numerical study of radiofrequency deposition in a spherical phantom using surface coils
-
Strilka RJ, Li S. Martin JT, Collins CM, Smith MB. A numerical study of radiofrequency deposition in a spherical phantom using surface coils. Magn Reson Imaging 1998;16:787-798.
-
(1998)
Magn Reson Imaging
, vol.16
, pp. 787-798
-
-
Strilka, R.J.1
Li, S.2
Martin, J.T.3
Collins, C.M.4
Smith, M.B.5
-
10
-
-
0030074979
-
The evaluation of dielectric resonators containing H2O or D2O as RF coils for high-field MR imaging and spectroscopy
-
Wen H, Jaffer FA, Denison TJ, Duewell S. Chesnick AS, Balaban RS. The evaluation of dielectric resonators containing H2O or D2O as RF coils for high-field MR imaging and spectroscopy. J Magn Reson 1996;110B;117-123.
-
(1996)
J Magn Reson
, vol.110 B
, pp. 117-123
-
-
Wen, H.1
Jaffer, F.A.2
Denison, T.J.3
Duewell, S.4
Chesnick, A.S.5
Balaban, R.S.6
-
12
-
-
0035088728
-
Signal-to-noise ratio and absorbed power as functions of main magnetic field strength and definition of "90°" RF pulse for the head in the birdcage coil
-
Collins CM, Smith MB. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength and definition of "90°" RF pulse for the head in the birdcage coil. Magn Reson Med 2001;45:684-691.
-
(2001)
Magn Reson Med
, vol.45
, pp. 684-691
-
-
Collins, C.M.1
Smith, M.B.2
-
13
-
-
0036238849
-
Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
-
Collins CM, Yang QX, Wang JH, et al. Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz. Magn Reson Med 2002;47:1026-1028.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1026-1028
-
-
Collins, C.M.1
Yang, Q.X.2
Wang, J.H.3
-
14
-
-
0034900050
-
Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties
-
Alecci M, Collins CM, Smith MB, Jezzard P. Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties. Magn Reson Med 2001;46:379-385.
-
(2001)
Magn Reson Med
, vol.46
, pp. 379-385
-
-
Alecci, M.1
Collins, C.M.2
Smith, M.B.3
Jezzard, P.4
-
15
-
-
0031884051
-
Ultimate intrinsic signal-to-noise ratio in MRI
-
Ocali O, Atalar E. Ultimate intrinsic signal-to-noise ratio in MRI. Magn Reson Med 1998;39:462-473.
-
(1998)
Magn Reson Med
, vol.39
, pp. 462-473
-
-
Ocali, O.1
Atalar, E.2
-
16
-
-
4243556316
-
Standing waves in uniform water phantoms
-
Tofts PS. Standing waves in uniform water phantoms. J Magn Reson 1994;104B:143-147.
-
(1994)
J Magn Reson
, vol.104 B
, pp. 143-147
-
-
Tofts, P.S.1
-
17
-
-
0032129166
-
Standing-wave and RF penetration artifacts caused by elliptic geometry: An electrodynamic analysis of MRI
-
Sled JG, Pike GB. Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI. IEEE Trans Med Imaging 1998;17:653-662.
-
(1998)
IEEE Trans Med Imaging
, vol.17
, pp. 653-662
-
-
Sled, J.G.1
Pike, G.B.2
|