-
1
-
-
33645224073
-
Finite element analysis applied to cornea reshaping
-
Cabrera Fernández D, Niazy AM, Kurtz RM, Djotyan GP, Juhasz T. Finite element analysis applied to cornea reshaping. J Biom Optics 2005 10 : 064018.
-
(2005)
J Biom Optics
, vol.10
, pp. 064018
-
-
Cabrera Fernández, D.1
Niazy, A.M.2
Kurtz, R.M.3
Djotyan, G.P.4
Juhasz, T.5
-
2
-
-
13844317405
-
Interferometric techniques to measure biomechanical changes in the cornea induced by refractive surgery
-
Jaycock PD, Lobo L, Ibrahim J, Tyrer J, Marshall J. Interferometric techniques to measure biomechanical changes in the cornea induced by refractive surgery. J Cataract Refract Surg 2005 31 : 175 184.
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 175-184
-
-
Jaycock, P.D.1
Lobo, L.2
Ibrahim, J.3
Tyrer, J.4
Marshall, J.5
-
3
-
-
33845499055
-
Changes in corneal biomechanics and intraocular pressure before and after LASIK using static, dynamic and noncontact tonometry
-
Pepose J, Feigenbaum S, Qazi M, Sanderson J, Roberts C. Changes in corneal biomechanics and intraocular pressure before and after LASIK using static, dynamic and noncontact tonometry. Am J Ophthalmol 2007 143 : 39 47.
-
(2007)
Am J Ophthalmol
, vol.143
, pp. 39-47
-
-
Pepose, J.1
Feigenbaum, S.2
Qazi, M.3
Sanderson, J.4
Roberts, C.5
-
4
-
-
34547105084
-
Corneal biomechanical properties in normal, post-laser in situ keratomileusis and keratoconic eyes
-
Ortiz D, Piñero D, Shabayek MH, Arnalich-Montiel F, Alió J. Corneal biomechanical properties in normal, post-laser in situ keratomileusis and keratoconic eyes. J Cataract Refract Surg 2007 33 : 1371 1375.
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 1371-1375
-
-
Ortiz, D.1
Piñero, D.2
Shabayek, M.H.3
Arnalich-Montiel, F.4
Alió, J.5
-
5
-
-
34548022426
-
Assessment of the biomechanical properties of the cornea with the Ocular Response Analyzer in normal and keratoconic eyes
-
Shah S, Laiquzzaman M Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the Ocular Response Analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 2007 48 : 3026 3031.
-
(2007)
Invest Ophthalmol Vis Sci
, vol.48
, pp. 3026-3031
-
-
Shah, S.1
Laiquzzaman, M.2
Bhojwani, R.3
Mantry, S.4
Cunliffe, I.5
-
6
-
-
13844313434
-
Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis
-
Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: Quantitative analysis. J Cataract Refract Surg 2005 31 : 146 155.
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 146-155
-
-
Liu, J.1
Roberts, C.J.2
-
7
-
-
33646190149
-
Central corneal thickness and corneal hysteresis associated with glaucoma damage
-
Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA. Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol 2006 141 : 868 875.
-
(2006)
Am J Ophthalmol
, vol.141
, pp. 868-875
-
-
Congdon, N.G.1
Broman, A.T.2
Bandeen-Roche, K.3
Grover, D.4
Quigley, H.A.5
-
8
-
-
41249092492
-
Correlations between corneal hysteresis, intraocular pressure and corneal central pachymetry
-
Touboul D, Roberts C, Kérautret J, Garra C, Maurice-Yison S, Saubusse E, Colin J. Correlations between corneal hysteresis, intraocular pressure and corneal central pachymetry. J Cataract Refract Surg 2008 34 : 616 622.
-
(2008)
J Cataract Refract Surg
, vol.34
, pp. 616-622
-
-
Touboul, D.1
Roberts, C.2
Kérautret, J.3
Garra, C.4
Maurice-Yison, S.5
Saubusse, E.6
Colin, J.7
-
9
-
-
42549163720
-
Pilot study on the influence of corneal biomechanical properties over the short term in response to corneal refractive therapy for myopia
-
González-Méijome JM, Villa-Collar C, Queirós A, Jorge J, Parafita MA. Pilot study on the influence of corneal biomechanical properties over the short term in response to corneal refractive therapy for myopia. Cornea 2008 27 : 421 426.
-
(2008)
Cornea
, vol.27
, pp. 421-426
-
-
González-Méijome, J.M.1
Villa-Collar, C.2
Queirós, A.3
Jorge, J.4
Parafita, M.A.5
-
10
-
-
13844317411
-
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
-
Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 2005 31 : 156 162.
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 156-162
-
-
Luce, D.A.1
-
11
-
-
34248347895
-
Corneal thickness- and age-related biomechanical properties of the cornea measured with the Ocular Response Analyzer
-
Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-Heath DF. Corneal thickness- and age-related biomechanical properties of the cornea measured with the Ocular Response Analyzer. Invest Ophthalmol Vis Sci 2006 47 : 5337 5347.
-
(2006)
Invest Ophthalmol Vis Sci
, vol.47
, pp. 5337-5347
-
-
Kotecha, A.1
Elsheikh, A.2
Roberts, C.R.3
Zhu, H.4
Garway-Heath, D.F.5
-
12
-
-
35848966791
-
What biomechanical properties of the cornea are relevant for the clinician?
-
S114.
-
Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol 2007 52 : S109 S114.
-
(2007)
Surv Ophthalmol
, vol.52
, pp. 109
-
-
Kotecha, A.1
-
14
-
-
33845227093
-
Corneal hysteresis and intraocular pressure measurements in children using the Reichert ocular response analyzer
-
Kirwan C, O'Keefe M, Lanigan B. Corneal hysteresis and intraocular pressure measurements in children using the Reichert ocular response analyzer. Am J Ophthalmol 2006 142 : 990 992.
-
(2006)
Am J Ophthalmol
, vol.142
, pp. 990-992
-
-
Kirwan, C.1
O'Keefe, M.2
Lanigan, B.3
-
15
-
-
41949128428
-
Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: Corneal biomechanical and tonometric implications
-
Moreno-Montañés J, Maldonado MJ, García N, Mendiluce L, García-Gómez PJ, Seguí-Gómez M. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications. Invest Ophthalmol Vis Sci 2008 49 : 968 974.
-
(2008)
Invest Ophthalmol Vis Sci
, vol.49
, pp. 968-974
-
-
Moreno-Montañés, J.1
Maldonado, M.J.2
García, N.3
Mendiluce, L.4
García-Gómez, P.J.5
Seguí-Gómez, M.6
-
16
-
-
33845807890
-
Effects of corneal thickness, corneal curvature and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry
-
Los Angeles Latino Eye Study Group
-
Francis BA, Hsieh A, Lai MY, Chopra V, Pena F, Azen S, Varma R, Los Angeles Latino Eye Study Group. Effects of corneal thickness, corneal curvature and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology 2007 114 : 20 26.
-
(2007)
Ophthalmology
, vol.114
, pp. 20-26
-
-
Francis, B.A.1
Hsieh, A.2
Lai, M.Y.3
Chopra, V.4
Pena, F.5
Azen, S.6
Varma, R.7
-
17
-
-
0036257336
-
Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study
-
The Reykjavik Eye Study Group
-
Eysteinsson T, Jonasson F, Sasaki H, Arnarsson A, Sverrisson T, Sasaki K, Stefánsson E, the Reykjavik Eye Study Group. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. Acta Ophthalmol Scand 2002 80 : 11 15.
-
(2002)
Acta Ophthalmol Scand
, vol.80
, pp. 11-15
-
-
Eysteinsson, T.1
Jonasson, F.2
Sasaki, H.3
Arnarsson, A.4
Sverrisson, T.5
Sasaki, K.6
Stefánsson, E.7
|