메뉴 건너뛰기




Volumn 19, Issue 5, 2009, Pages 303-310

Microneedles and transdermal drug delivery

Author keywords

Iontophoresis; Microneedles; Microparticles; Physical enhancement; Stratum corneum; Transdermal delivery

Indexed keywords

ANTISENSE OLIGONUCLEOTIDE; CARBOHYDRATE DERIVATIVE; DESMOPRESSIN; GLASS; INSULIN; LOW MOLECULAR WEIGHT HEPARIN; MALTOSE; METHOTREXATE; MICROSPHERE; POLYMER; SILICON; TITANIUM;

EID: 70350067448     PISSN: 17732247     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1773-2247(09)50065-2     Document Type: Review
Times cited : (34)

References (58)
  • 1
    • 0032883241 scopus 로고    scopus 로고
    • Transdermal penetration enhancers: Applications, limitations, and potential
    • Finnin B.C., Morgan T.M. - Transdermal penetration enhancers: applications, limitations, and potential. - J Pharm Sci, 88, 955-958, 1999.
    • (1999) J Pharm Sci , vol.88 , pp. 955-958
    • Finnin, B.C.1    Morgan, T.M.2
  • 2
    • 55649101168 scopus 로고    scopus 로고
    • Micro-scale devices for transdermal drug delivery
    • Arora A., Prausnitz M.R., Mitragotri S. - Micro-scale devices for transdermal drug delivery. - Int J Pharm, 364, 227-236, 2008.
    • (2008) Int J Pharm , vol.364 , pp. 227-236
    • Arora, A.1    Prausnitz, M.R.2    Mitragotri, S.3
  • 3
    • 53549130424 scopus 로고    scopus 로고
    • Proteins and peptides: Strategies for delivery to and across the skin
    • Benson H.A., Namjoshi S. - Proteins and peptides: strategies for delivery to and across the skin. - J Pharm Sci, 97, 3591-3610, 2008.
    • (2008) J Pharm Sci , vol.97 , pp. 3591-3610
    • Benson, H.A.1    Namjoshi, S.2
  • 4
    • 23544463503 scopus 로고
    • Drug Delivery Device
    • Alza Corporation, USA. International patent classification A61M 700. Patent number 3964482
    • Gerstel M.S., Place V.A. - Drug Delivery Device. Alza Corporation, USA. International patent classification A61M 700. Patent number 3964482, 1976.
    • (1976)
    • Gerstel, M.S.1    Place, V.A.2
  • 7
    • 0037462995 scopus 로고    scopus 로고
    • Microfabricated drug delivery systems: From particles to pores
    • DOI 10.1016/S0169-409X(02)00227-2
    • Tao S.L., Desai T.A. - Microfabricated drug delivery systems: from particles to pores. - Adv Drug Deliv Rev, 55, 315-328, 2003. (Pubitemid 36293790)
    • (2003) Advanced Drug Delivery Reviews , vol.55 , Issue.3 , pp. 315-328
    • Tao, S.L.1    Desai, T.A.2
  • 8
    • 22144493011 scopus 로고    scopus 로고
    • Process optimization and characterization of silicon microneedles fabricated by wet etch technology
    • DOI 10.1016/j.mejo.2005.04.044, PII S0026269205001825
    • Wilke N., Mulcahy A., Ye S.-R., Morrissey A. - Process optimization of silicon microneedles fabricated by wet etch technology. - Microelectronics Journal, 36, 650-656, 2005. (Pubitemid 40973306)
    • (2005) Microelectronics Journal , vol.36 , Issue.7 , pp. 650-656
    • Wilke, N.1    Mulcahy, A.2    Ye, S.-R.3    Morrissey, A.4
  • 10
    • 40349099997 scopus 로고    scopus 로고
    • Membrane-sealed hollow microneedles and related administration schemes for transdermal drug delivery
    • DOI 10.1007/s10544-007-9133-8
    • Roxhed N., Griss P., Stemme G. - Membrane-sealed hollow microneedles and related administration schemes for transdermal drug delivery. - Biomed Microdevices, 10, 271-279, 2008. (Pubitemid 351337929)
    • (2008) Biomedical Microdevices , vol.10 , Issue.2 , pp. 271-279
    • Roxhed, N.1    Griss, P.2    Stemme, G.3
  • 13
    • 33744550696 scopus 로고    scopus 로고
    • Microfabricated silicon microneedle array for transdermal drug delivery
    • DOI 10.1088/1742-6596/34/1/186
    • Ji J., Tay F.E.H., Miao J., Iliescu C. - Microfabricated silicon microneedle array for transdermal drug delivery. - Journal of Physics: Conference Series, 34, 1127-1131, 2006. (Pubitemid 43812576)
    • (2006) Journal of Physics: Conference Series , vol.34 , Issue.1 , pp. 1127-1131
    • Ji, J.1    Tay, F.E.H.2    Miao, J.3    Iliescu, C.4
  • 14
    • 18144410179 scopus 로고    scopus 로고
    • Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
    • DOI 10.1016/j.jconrel.2005.02.002
    • Park J.H., Allen M.G., Prausnitz M.R. - Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery. - J Control Release, 104, 51-66, 2005. (Pubitemid 40615235)
    • (2005) Journal of Controlled Release , vol.104 , Issue.1 , pp. 51-66
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 16
    • 33847301400 scopus 로고    scopus 로고
    • Polymeric microneedle fabrication using a microinjection molding technique
    • DOI 10.1007/s00542-006-0204-1, HARMST, High Asprect Ratio Micro Structure Technology Workshop, Gyenogju, Korea, 10-13 June 2005 - part 2
    • Sammoura F., Kang J.J., Heo Y.-M., Jung T.S., Lin L. - Polymerie microneedle fabrication using a microinjection molding technique. - Microsystem Technologies, 13, 517-522, 2007. (Pubitemid 46324428)
    • (2007) Microsystem Technologies , vol.13 , Issue.5-6 , pp. 517-522
    • Sammoura, F.1    Kang, J.2    Heo, Y.-M.3    Jung, T.4    Lin, L.5
  • 17
    • 11344280016 scopus 로고    scopus 로고
    • Projection ablation of glass-based single and arrayed microstructures using excimer laser
    • DOI 10.1016/j.optlastec.2004.04.007, PII S003039920400091X
    • Chen Y.T., Ma K.J., Tseng A.A., Chen P.H.- Projection ablation of glass-based single and arrayed microstructures using excimer laser. - Optics and Laser Technology, 37, 271-280, 2005. (Pubitemid 40073332)
    • (2005) Optics and Laser Technology , vol.37 , Issue.4 , pp. 271-280
    • Chen, Y.-T.1    Ma, K.-J.2    Tseng, A.A.3    Chen, P.H.4
  • 18
    • 44249091951 scopus 로고    scopus 로고
    • Silicon microneedle array with biodegradable tips for transdermal drug delivery
    • Chen B., Wei J., Tay F.E.H., Wong Y.T., Iliescu C. - Silicon microneedle array with biodegradable tips for transdermal drug delivery. - Microsystem Technologies, 14, 1015-1019, 2008.
    • (2008) Microsystem Technologies , vol.14 , pp. 1015-1019
    • Chen, B.1    Wei, J.2    Tay, F.E.H.3    Wong, Y.T.4    Iliescu, C.5
  • 19
    • 0035659567 scopus 로고    scopus 로고
    • Transdermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology
    • DOI 10.1023/A:1013395102049
    • Lin W., Cormier M., Samiee A., Griffin A., Johnson B., Teng C.L., Hardee G.E., Daddona P.E. - Transdermal delivery of antisense oligonucleotides with microprojection patch (Macroflux) technology. - Pharm Res, 18, 1789-1793, 2001. (Pubitemid 34020438)
    • (2001) Pharmaceutical Research , vol.18 , Issue.12 , pp. 1789-1793
    • Lin, W.1    Cormier, M.2    Samiee, A.3    Griffin, A.4    Johnson, B.5    Teng, C.-L.6    Hardee, G.E.7    Daddona, P.E.8
  • 20
    • 38049146196 scopus 로고    scopus 로고
    • Characterization of solid maltose microneedles and their use for transdermal delivery
    • Kolli C.S., Banga A.K. - Characterization of solid maltose microneedles and their use for transdermal delivery. - Pharm Res, 25, 104-113, 2008.
    • (2008) Pharm Res , vol.25 , pp. 104-113
    • Kolli, C.S.1    Banga, A.K.2
  • 22
    • 58949100880 scopus 로고    scopus 로고
    • In vitro transdermal delivery of therapeutic antibodies using maltose microneedles
    • Li G., Badkar A., Nema S., Kolli C.S., Banga A.K. - In vitro transdermal delivery of therapeutic antibodies using maltose microneedles. - Int J Pharm, 368, 109-115, 2009.
    • (2009) Int J Pharm , vol.368 , pp. 109-115
    • Li, G.1    Badkar, A.2    Nema, S.3    Kolli, C.S.4    Banga, A.K.5
  • 23
    • 57049106811 scopus 로고    scopus 로고
    • Enhanced transdermal delivery of low molecular weight heparin by barrier perturbation
    • Lanke S.S., Kolli C.S., Strom J.G., Banga A.K. - Enhanced transdermal delivery of low molecular weight heparin by barrier perturbation. - Int J Pharm, 365, 26-33, 2009.
    • (2009) Int J Pharm , vol.365 , pp. 26-33
    • Lanke, S.S.1    Kolli, C.S.2    Strom, J.G.3    Banga, A.K.4
  • 24
    • 38349175137 scopus 로고    scopus 로고
    • Synergistic effect of iontophoresis and soluble microneedles for transdermal delivery of methotrexate
    • Vemulapalli V., Yang Y., Friden P.M., Banga A.K. - Synergistic effect of iontophoresis and soluble microneedles for transdermal delivery of methotrexate. - J Pharm Pharmacol, 60, 27-33, 2008.
    • (2008) J Pharm Pharmacol , vol.60 , pp. 27-33
    • Vemulapalli, V.1    Yang, Y.2    Friden, P.M.3    Banga, A.K.4
  • 25
    • 40049112272 scopus 로고    scopus 로고
    • Dissolving microneedles for transdermal drug delivery
    • Lee J.W., Park J.H., Prausnitz M.R. - Dissolving microneedles for transdermal drug delivery. - Biomaterials, 29, 2113-2124, 2008.
    • (2008) Biomaterials , vol.29 , pp. 2113-2124
    • Lee, J.W.1    Park, J.H.2    Prausnitz, M.R.3
  • 27
    • 53249119663 scopus 로고    scopus 로고
    • Transdermal drug delivery by coated microneedles: Geometry effects on effective skin thickness and drug permeability
    • Davidson A., Al-Qallaf B., Das D.B. - Transdermal drug delivery by coated microneedles: Geometry effects on effective skin thickness and drug permeability. - Chemical Engineering Research and Design, 86, 1196-1206, 2008.
    • (2008) Chemical Engineering Research and Design , vol.86 , pp. 1196-1206
    • Davidson, A.1    Al-Qallaf, B.2    Das, D.B.3
  • 28
    • 0344270926 scopus 로고    scopus 로고
    • Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies
    • McAllister D.V., Wang P.M., Davis S.R, Park J.H., Canatella P.J., Allen M.G., Prausnitz M.R. - Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: fabrication methods and transport studies. - Proc Natl Acad Sci U S A, 100, 13755-13760, 2003.
    • (2003) Proc Natl Acad Sci U S A , vol.100 , pp. 13755-13760
    • McAllister, D.V.1    Wang, P.M.2    Davis, S.R.3    Park, J.H.4    Canatella, P.J.5    Allen, M.G.6    Prausnitz, M.R.7
  • 29
    • 32544446281 scopus 로고    scopus 로고
    • Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system
    • DOI 10.1016/j.vaccine.2005.09.049, PII S0264410X05010157
    • Widera G., Johnson J., Kim L., Libiran L., Nyam K., Daddona P.E., Cormier M. - Effect of delivery parameters on immunization to ovalbumin following intracutaneous administration by a coated microneedle array patch system. - Vaccine, 24, 1653-1664, 2006. (Pubitemid 43238242)
    • (2006) Vaccine , vol.24 , Issue.10 , pp. 1653-1664
    • Widera, G.1    Johnson, J.2    Kim, L.3    Libiran, L.4    Nyam, K.5    Daddona, P.E.6    Cormier, M.7
  • 30
    • 0036007129 scopus 로고    scopus 로고
    • Macroflux microprojection array patch technology: A new and efficient approach for intracutaneous immunization
    • DOI 10.1023/A:1013607400040
    • Matriano J.A., Cormier M., Johnson J., Young W.A., Buttery M., Nyam K., Daddona P.E. - Macroflux microprojection array patch technology: a new and efficient approach for intracutaneous immunization. - Pharm Res, 19, 63-70, 2002. (Pubitemid 34075108)
    • (2002) Pharmaceutical Research , vol.19 , Issue.1 , pp. 63-70
    • Matriano, J.A.1    Cormier, M.2    Johnson, J.3    Young, W.A.4    Buttery, M.5    Nyam, K.6    Daddona, P.E.7
  • 31
    • 3042556333 scopus 로고    scopus 로고
    • Transdermal delivery of desmopressin using a coated microneedle array patch system
    • DOI 10.1016/j.jconrel.2004.04.003, PII S0168365904001713
    • Cormier M., Johnson B., Ameri M., Nyam K., Libiran L., Zhang D.D., Daddona P. - Transdermal delivery of desmopressin using a coated microneedle array patch system. - J Control Release, 97, 503-511, 2004. (Pubitemid 38802952)
    • (2004) Journal of Controlled Release , vol.97 , Issue.3 , pp. 503-511
    • Cormier, M.1    Johnson, B.2    Ameri, M.3    Nyam, K.4    Libiran, L.5    Zhang, D.D.6    Daddona, P.7
  • 32
    • 33846492454 scopus 로고    scopus 로고
    • Coated microneedles for transdermal delivery
    • Gill H.S., Prausnitz M.R. - Coated microneedles for transdermal delivery. - J Control Release, 117, 227-237, 2007.
    • (2007) J Control Release , vol.117 , pp. 227-237
    • Gill, H.S.1    Prausnitz, M.R.2
  • 33
    • 33646882359 scopus 로고    scopus 로고
    • Polymer microneedles for controlled-release drug delivery
    • DOI 10.1007/s11095-006-0028-9
    • Park J.H., Allen M.G., Prausnitz M.R. - Polymer microneedles for controlled-release drug delivery. - Pharm Res, 23, 1008-1019, 2006. (Pubitemid 43781409)
    • (2006) Pharmaceutical Research , vol.23 , Issue.5 , pp. 1008-1019
    • Park, J.-H.1    Allen, M.G.2    Prausnitz, M.R.3
  • 34
    • 33646148967 scopus 로고    scopus 로고
    • Precise microinjection into skin using hollow microneedles
    • Wang P.M., Cornwell M., Hill J., Prausnitz M.R. - Precise microinjection into skin using hollow microneedles. - J Invest Dermatol, 126, 1080-1087, 2006.
    • (2006) J Invest Dermatol , vol.126 , pp. 1080-1087
    • Wang, P.M.1    Cornwell, M.2    Hill, J.3    Prausnitz, M.R.4
  • 36
    • 4344666269 scopus 로고    scopus 로고
    • Microneedle array for transdermal biological fluid extraction and in situ analysis
    • Mukerjee E.V., Collins S.D., Isseroff R.R., Smith R.L. - Microneedle array for transdermal biological fluid extraction and in situ analysis. - Sensors and Actuators A, 114, 267-275, 2004.
    • (2004) Sensors and Actuators A , vol.114 , pp. 267-275
    • Mukerjee, E.V.1    Collins, S.D.2    Isseroff, R.R.3    Smith, R.L.4
  • 38
    • 34249872741 scopus 로고    scopus 로고
    • Novel microneedle patches for active insulin delivery are efficient in maintaining glycaemic control: An initial comparison with subcutaneous administration
    • DOI 10.1007/s11095-007-9256-x
    • Nordquist L., Roxhed N., Griss P., Stemme G. - Novel microneedle patches for active insulin delivery are efficient in maintaining glycaemic control: an initial comparison with subcutaneous administration. - Pharm Res, 24, 1381-1388, 2007. (Pubitemid 46870597)
    • (2007) Pharmaceutical Research , vol.24 , Issue.7 , pp. 1381-1388
    • Nordquist, L.1    Roxhed, N.2    Griss, P.3    Stemme, G.4
  • 39
    • 18144406466 scopus 로고    scopus 로고
    • In vitro and in vivo characterization of MEMS microneedles
    • DOI 10.1007/s10544-005-6171-y
    • Teo M.A., Shearwood C., Ng K.C., Lu J., Moochhala S. - In vitro and in vivo characterization of MEMS microneedles. - Biomed Microdevices, 7, 47-52, 2005. (Pubitemid 40613130)
    • (2005) Biomedical Microdevices , vol.7 , Issue.1 , pp. 47-52
    • Ling Teo, M.A.1    Shearwood, C.2    Ng, K.C.3    Lu, J.4    Moochhala, S.5
  • 40
    • 33646709695 scopus 로고    scopus 로고
    • Mechanism of fluid infusion during microneedle insertion and retraction
    • DOI 10.1016/j.jconrel.2006.02.017, PII S0168365906001076
    • Martanto W., Moore J.S., Couse T., Prausnitz M.R. - Mechanism of fluid infusion during microneedle insertion and retraction. - J Control Release, 112, 357-361, 2006. (Pubitemid 43737149)
    • (2006) Journal of Controlled Release , vol.112 , Issue.3 , pp. 357-361
    • Martanto, W.1    Moore, J.S.2    Couse, T.3    Prausnitz, M.R.4
  • 41
    • 4544385215 scopus 로고    scopus 로고
    • Microneedle insertion force reduction using vibratory actuation
    • DOI 10.1023/B:BMMD.0000042046.07678.2e
    • Yang M., Zahn J.D. - Microneedle insertion force reduction using vibratory actuation. - Biomed Microdevices, 6, 177-182, 2004. (Pubitemid 39256163)
    • (2004) Biomedical Microdevices , vol.6 , Issue.3 , pp. 177-182
    • Yang, M.1    Zahn, J.D.2
  • 42
    • 2942716734 scopus 로고    scopus 로고
    • Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
    • Davis S.P., Landis B.J., Adams Z.H., Allen M.G., Prausnitz M.R. - Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force. - J Biomech, 37, 1155-1163, 2004.
    • (2004) J Biomech , vol.37 , pp. 1155-1163
    • Davis, S.P.1    Landis, B.J.2    Adams, Z.H.3    Allen, M.G.4    Prausnitz, M.R.5
  • 43
    • 0008670190 scopus 로고    scopus 로고
    • Microfabricated polysilicon microneedles for minimally invasive biomedical devices
    • Zahn J.D., Talbot N.H., Liepmann D., Pisano A.P. - Microfabricated polysilicon microneedles for minimally invasive biomedical devices. - Biomedical Microdevices, 2, 295-303, 2000.
    • (2000) Biomedical Microdevices , vol.2 , pp. 295-303
    • Zahn, J.D.1    Talbot, N.H.2    Liepmann, D.3    Pisano, A.P.4
  • 44
  • 49
    • 50449085359 scopus 로고    scopus 로고
    • In vivo assessment of safety of microneedle arrays in human skin
    • Bal S.M., Caussin J., Pavel S., Bouwstra J.A. - In vivo assessment of safety of microneedle arrays in human skin. - Eur J Pharm Sci, 35, 193-202, 2008.
    • (2008) Eur J Pharm Sci , vol.35 , pp. 193-202
    • Bal, S.M.1    Caussin, J.2    Pavel, S.3    Bouwstra, J.A.4
  • 50
    • 14844286423 scopus 로고    scopus 로고
    • Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter
    • DOI 10.1111/j.1600-0846.2005.00101.x
    • De Paepe K., Houben E., Adam R., Wiesemann F., Rogiers V. - Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter. - Skin Res Technol, 11, 61-69, 2005. (Pubitemid 40347610)
    • (2005) Skin Research and Technology , vol.11 , Issue.1 , pp. 61-69
    • De Paepe, K.1    Houben, E.2    Adam, R.3    Wiessemann, F.4    Rogiers, V.5
  • 51
    • 0029807938 scopus 로고    scopus 로고
    • Transdermal delivery of peptides by iontophoresis
    • Hirvonen J., Kalia Y.N., Guy R.H. - Transdermal delivery of peptides by iontophoresis. - Nat Biotechnol, 14, 1710-1713, 1996.
    • (1996) Nat Biotechnol , vol.14 , pp. 1710-1713
    • Hirvonen, J.1    Kalia, Y.N.2    Guy, R.H.3
  • 52
    • 35448967913 scopus 로고    scopus 로고
    • Skin pretreatment with an Er:YAG laser promotes the transdermal delivery of three narcotic analgesics
    • Lee W.R., Shen S.C., Fang C.L., Liu C.R., Fang J.Y. - Skin pretreatment with an Er:YAG laser promotes the transdermal delivery of three narcotic analgesics. - Lasers Med Sci, 22, 271-278, 2007.
    • (2007) Lasers Med Sci , vol.22 , pp. 271-278
    • Lee, W.R.1    Shen, S.C.2    Fang, C.L.3    Liu, C.R.4    Fang, J.Y.5
  • 54
    • 0037472111 scopus 로고    scopus 로고
    • Radiofrequency-driven skin microchanneling as a new way for electrically assisted transdermal delivery of hydrophilic drugs
    • DOI 10.1016/S0168-3659(03)00123-8
    • Sintov A.C., Krymberk I., Daniel D., Hannan T., Sohn Z., Levin G. - Radiofrequency-driven skin microchanneling as a new way for electrically assisted transdermal delivery of hydrophilic drugs. - J Control Release, 89, 311-320, 2003. (Pubitemid 36507024)
    • (2003) Journal of Controlled Release , vol.89 , Issue.2 , pp. 311-320
    • Sintov, A.C.1    Krymberk, I.2    Daniel, D.3    Hannan, T.4    Sohn, Z.5    Levin, G.6
  • 55
    • 3142717491 scopus 로고    scopus 로고
    • Effect of tape stripping on percutaneous penetration and topical vaccination
    • DOI 10.1159/000078695
    • Choi M.J., Zhai H., Loffler H., Dreher F., Maibach H.I. - Effect of tape stripping on percutaneous penetration and topical vaccination. - Exogenous Dermatology, 2, 262-269, 2003. (Pubitemid 38916089)
    • (2003) Exogenous Dermatology , vol.2 , Issue.5 , pp. 262-269
    • Choi, M.J.1    Zhai, H.2    Loffler, H.3    Dreher, F.4    Maibach, H.I.5
  • 56
    • 0035962388 scopus 로고    scopus 로고
    • In vivo assessment of enhanced topical delivery of terbinafine to human stratum corneum
    • DOI 10.1016/S0168-3659(01)00244-9, PII S0168365901002449
    • Alberti I., Kalia Y.N., Naik A., Bonny J.D., Guy R.H. - In vivo assessment of enhanced topical delivery of terbinafine to human stratum corneum. - J Control Release, 71, 319-327, 2001. (Pubitemid 32276051)
    • (2001) Journal of Controlled Release , vol.71 , Issue.3 , pp. 319-327
    • Alberti, I.1    Kalia, Y.N.2    Naik, A.3    Bonny, J.-D.4    Guy, R.H.5
  • 58
    • 33645226351 scopus 로고    scopus 로고
    • Controlled transdermal delivery of model drug compounds by MEMS microneedle array
    • DOI 10.1016/j.nano.2005.03.001, PII S1549963405000547
    • Xie Y., Xu B., Gao Y. - Controlled transdermal delivery of model drug compounds by MEMS microneedle array. - Nanomedicine, 1, 184-190, 2005. (Pubitemid 43963615)
    • (2005) Nanomedicine: Nanotechnology, Biology, and Medicine , vol.1 , Issue.2 , pp. 184-190
    • Xie, Y.1    Xu, B.2    Gao, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.