Volumn 36, Issue 10, 2009, Pages 4409-4420

A solid iodinated phantom material for use in tomographic x-ray imaging

Author keywords

Computed tomography; Dual energy; Iodine; Phantoms; Quality control; Quantitative imaging

Indexed keywords

CALIBRATION; IODINE; PHANTOMS; QUALITY CONTROL; X RAY RADIOGRAPHY;

EID: 70349684826     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3213516     Document Type: Article
Times cited : (14)

References (49)
  • 1
    • 0004266415 scopus 로고    scopus 로고
    • edited by D. O. Cosgrove, P. Dawson, and R. G. Grainger (Isis Medical Media, Oxford)
    • Textbook of Contrast Media, edited by, D. O. Cosgrove, P. Dawson, and, R. G. Grainger, (Isis Medical Media, Oxford, 1999).
    • (1999) Textbook of Contrast Media
  • 2
    • 0022230416 scopus 로고
    • Digital subtraction angiography systems: Assessing performance with phantoms
    • 0033-8419.
    • M. Goodsitt, L. Abbate, and J. Hesselink, " Digital subtraction angiography systems: Assessing performance with phantoms.," Radiology 0033-8419 156, 811-815 (1985).
    • (1985) Radiology , vol.156 , pp. 811-815
    • Goodsitt, M.1    Abbate, L.2    Hesselink, J.3
  • 3
    • 44449109634 scopus 로고    scopus 로고
    • Validation of the use of calibration factors between the iodine concentration and the computed tomography number measured outside the objects for estimation of iodine concentration inside the objects: Phantom experiment
    • DOI 10.1007/s11604-007-0220-9
    • K. Takanami, S. Higano, K. Takase, T. Kaneta, T. Yamada, H. Ishiya, I. Mori, and S. Takahashi, " Validation of the use of calibration factors between the iodine concentration and the computed tomography number measured outside the objects for estimation of iodine concentration inside the objects: Phantom experiment.," Radiat. Med. 0288-2043 26, 237-243 (2008). 10.1007/s11604-007-0220-9 (Pubitemid 351754728)
    • (2008) Radiation Medicine - Medical Imaging and Radiation Oncology , vol.26 , Issue.4 , pp. 237-243
    • Takanami, K.1    Higano, S.2    Takase, K.3    Kaneta, T.4    Yamada, T.5    Ishiya, H.6    Mori, I.7    Takahashi, S.8
  • 5
    • 35648976045 scopus 로고    scopus 로고
    • Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement
    • DOI 10.1118/1.2790841
    • M. Saito, " Dual-energy approach to contrast-enhanced mammography using the balanced filter method: Spectral optimization and preliminary phantom measurement.," Med. Phys. 0094-2405 34, 4236-4246 (2007). 10.1118/1.2790841 (Pubitemid 350029645)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4236-4246
    • Saito, M.1
  • 6
    • 34248663224 scopus 로고    scopus 로고
    • Quantitative contrast-enhanced computed tomography: Is there a need for system calibration?
    • DOI 10.1007/s00330-006-0424-x
    • K. A. Miles, H. Young, S. L. Chica, and P. D. Esser, " Quantitative contrast-enhanced computed tomography: Is there a need for system calibration?," Eur. Radiol. 0938-7994 17, 919-926 (2007). 10.1007/s00330-006-0424-x (Pubitemid 46766873)
    • (2007) European Radiology , vol.17 , Issue.4 , pp. 919-926
    • Miles, K.A.1    Young, H.2    Chica, S.L.3    Esser, P.D.4
  • 10
    • 0021804744 scopus 로고
    • Digital subtraction angiography system evaluation with phantoms
    • 0033-8419.
    • R. S. Wenstrup, K. P. Sweeney, and F. J. Scholz, " Digital subtraction angiography system evaluation with phantoms.," Radiology 0033-8419 155, 805-809 (1985).
    • (1985) Radiology , vol.155 , pp. 805-809
    • Wenstrup, R.S.1    Sweeney, K.P.2    Scholz, F.J.3
  • 11
    • 0021800508 scopus 로고
    • Dynamic and static phantoms for evaluation of digital subtraction angiographic systems
    • 0033-8419.
    • H. Fujita, K. Doi, H. P. Chan, M. L. Giger, and E. E. Duda, " Dynamic and static phantoms for evaluation of digital subtraction angiographic systems.," Radiology 0033-8419 155, 799-803 (1985).
    • (1985) Radiology , vol.155 , pp. 799-803
    • Fujita, H.1    Doi, K.2    Chan, H.P.3    Giger, M.L.4    Duda, E.E.5
  • 13
    • 0035026399 scopus 로고    scopus 로고
    • A new tool for benchmarking cardiovascular fluoroscopes
    • S. Balter, " A new tool for benchmarking cardiovascular fluoroscopes.," Radiat. Prot. Dosim. 0144-8420 94, 161-166 (2001). (Pubitemid 32433155)
    • (2001) Radiation Protection Dosimetry , vol.94 , Issue.1-2 , pp. 161-166
    • Balter, S.1
  • 14
    • 33947532649 scopus 로고    scopus 로고
    • Novel materials for low-contrast phantoms for computed tomography
    • 0895-3996.
    • K. Allert, S. Vangala, and F. DiBianca, " Novel materials for low-contrast phantoms for computed tomography.," J. X-Ray Sci. Technol. 0895-3996 15, 9-18 (2007).
    • (2007) J. X-Ray Sci. Technol. , vol.15 , pp. 9-18
    • Allert, K.1    Vangala, S.2    Dibianca, F.3
  • 15
    • 61349187579 scopus 로고    scopus 로고
    • Application- and patient size-dependent optimization of x-ray spectra for CT
    • 0094-2405,. 10.1118/1.3075901
    • W. A. Kalender, P. Deak, M. Kellermeier, M. van Straten, and S. V. Vollmar, " Application- and patient size-dependent optimization of x-ray spectra for CT.," Med. Phys. 0094-2405 36, 993-1007 (2009). 10.1118/1.3075901
    • (2009) Med. Phys. , vol.36 , pp. 993-1007
    • Kalender, W.A.1    Deak, P.2    Kellermeier, M.3    Van Straten, M.4    Vollmar, S.V.5
  • 16
    • 70349676608 scopus 로고    scopus 로고
    • Quality Assurance in Radiology and Medicine, "" (Moehrendorf, Germany), Vol.,.
    • Quality Assurance in Radiology and Medicine, " QRM-DEP-002, dual energy phantom. " (Moehrendorf, Germany, 2009), Vol. 2009, p. 2.
    • (2009) QRM-DEP-002, Dual Energy Phantom , vol.2009 , pp. 2
  • 17
    • 54049099191 scopus 로고    scopus 로고
    • Four-detector row computed tomographic angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease: Influence of contrast medium concentration
    • 0363-8715,. 10.1097/RCT.0b013e3181576cfd
    • R. Iezzi, A. R. Cotroneo, A. Filippone, D. Giancristofaro, and M. L. Storto, " Four-detector row computed tomographic angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease: Influence of contrast medium concentration.," J. Comput. Assist. Tomogr. 0363-8715 32, 690-696 (2008). 10.1097/RCT.0b013e3181576cfd
    • (2008) J. Comput. Assist. Tomogr. , vol.32 , pp. 690-696
    • Iezzi, R.1    Cotroneo, A.R.2    Filippone, A.3    Giancristofaro, D.4    Storto, M.L.5
  • 18
    • 33644868841 scopus 로고    scopus 로고
    • First-pass quantitative CT perfusion identifies thresholds for salvageable penumbra in acute stroke patients treated with intra-arterial therapy
    • 0195-6108.
    • P. W. Schaefer, L. Roccatagliata, C. Ledezma, B. Hoh, L. H. Schwamm, W. Koroshetz, R. G. Gonzalez, and M. H. Lev, " First-pass quantitative CT perfusion identifies thresholds for salvageable penumbra in acute stroke patients treated with intra-arterial therapy.," AJNR Am. J. Neuroradiol. 0195-6108 27, 20-25 (2006).
    • (2006) AJNR Am. J. Neuroradiol. , vol.27 , pp. 20-25
    • Schaefer, P.W.1    Roccatagliata, L.2    Ledezma, C.3    Hoh, B.4    Schwamm, L.H.5    Koroshetz, W.6    Gonzalez, R.G.7    Lev, M.H.8
  • 19
    • 21244502858 scopus 로고    scopus 로고
    • Assessment of the tumor microenvironment in cervix cancer using dynamic contrast enhanced CT, interstitial fluid pressure and oxygen measurements
    • 0360-3016,. 10.1016/j.ijrob2004.12.064
    • M. A. Haider, M. Milosevic, A. Fyles, I. Sitartchouk, I. Yeung, E. Henderson, G. Lockwood, T. Y. Lee, and T. P. Roberts, " Assessment of the tumor microenvironment in cervix cancer using dynamic contrast enhanced CT, interstitial fluid pressure and oxygen measurements.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 62, 1100-1107 (2005). 10.1016/j.ijrobp.2004.12. 064
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.62 , pp. 1100-1107
    • Haider, M.A.1    Milosevic, M.2    Fyles, A.3    Sitartchouk, I.4    Yeung, I.5    Henderson, E.6    Lockwood, G.7    Lee, T.Y.8    Roberts, T.P.9
  • 20
    • 36048936429 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced CT of head and neck tumors: Perfusion measurements using a distributed-parameter tracer kinetic model. Initial results and comparison with deconvolution-based analysis
    • DOI 10.1088/0031-9155/52/20/007, PII S0031915507403165
    • S. Bisdas, G. N. Konstantinou, P. S. Lee, C. H. Thng, J. Wagenblast, M. Baghi, and T. S. Koh, " Dynamic contrast-enhanced CT of head and neck tumors: Perfusion measurements using a distributed-parameter tracer kinetic model. initial results and comparison with deconvolution-based analysis.," Phys. Med. Biol. 0031-9155 52, 6181-6196 (2007). 10.1088/0031-9155/52/20/007 (Pubitemid 350093188)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.20 , pp. 6181-6196
    • Bisdas, S.1    Konstantinou, G.N.2    Lee, P.S.3    Thng, C.H.4    Wagenblast, J.5    Baghi, M.6    Koh, T.S.7
  • 22
    • 40949119836 scopus 로고    scopus 로고
    • Dedicated breast CT: Initial clinical experience
    • 0033-8419,. 10.1148/radiol.2463070410
    • K. K. Lindfors, J. M. Boone, T. R. Nelson, K. Yang, A. L. Kwan, and D. F. Miller, " Dedicated breast CT: Initial clinical experience.," Radiology 0033-8419 246, 725-733 (2008). 10.1148/radiol.2463070410
    • (2008) Radiology , vol.246 , pp. 725-733
    • Lindfors, K.K.1    Boone, J.M.2    Nelson, T.R.3    Yang, K.4    Kwan, A.L.5    Miller, D.F.6
  • 23
    • 35649005427 scopus 로고    scopus 로고
    • Radiological interpretation 2020: Toward quantitative image assessment
    • DOI 10.1118/1.2789501
    • J. Boone, " Radiological interpretation 2020: Toward quantitative image assessment.," Med. Phys. 0094-2405 34, 4173-4179 (2007). 10.1118/1.2789501 (Pubitemid 350029639)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4173-4179
    • Boone, J.M.1
  • 24
    • 44449089365 scopus 로고    scopus 로고
    • Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: A chest-phantom-study
    • DOI 10.1097/RLI.0b013e3181690042, PII 0000442420080600000006
    • Z. Szucs-Farkas, F. R. Verdun, G. von Allmen, R. L. Mini, and P. Vock, " Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: A chest-phantom-study.," Invest. Radiol. 0020-9996 43, 374 (2008). 10.1097/RLI.0b013e3181690042 (Pubitemid 351769895)
    • (2008) Investigative Radiology , vol.43 , Issue.6 , pp. 374-381
    • Szucs-Farkas, Z.1    Verdun, F.R.2    Von Allmen, G.3    Mini, R.L.4    Vock, P.5
  • 25
    • 70349697266 scopus 로고    scopus 로고
    • Epic Resins, (Epic Resins, Palmyra, WI).
    • Epic Resins, R3500/H5064 Product Datasheet (Epic Resins, Palmyra, WI, 2004).
    • (2004) R3500/H5064 Product Datasheet
  • 26
    • 0041929652 scopus 로고    scopus 로고
    • Contrast-enhanced digital mammography: Initial clinical experience
    • DOI 10.1148/radiol.2283020961
    • R. A. Jong, M. J. Yaffe, M. Skarpathiotakis, R. S. Shumak, N. M. Danjoux, A. Gunesekara, and D. B. Plewes, " Contrast-enhanced digital mammography: Initial clinical experience.," Radiology 0033-8419 228, 842-850 (2003). 10.1148/radiol.2283020961 (Pubitemid 37025497)
    • (2003) Radiology , vol.228 , Issue.3 , pp. 842-850
    • Jong, R.A.1    Yaffe, M.J.2    Skarpathiotakis, M.3    Shumak, R.S.4    Danjoux, N.M.5    Gunesekara, A.6    Plewes, D.B.7
  • 27
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiography
    • DOI 10.1088/0031-9155/42/1/001, PII S0031915597360904
    • M. J. Yaffe and J. A. Rowlands, " X-ray detectors for digital radiography.," Phys. Med. Biol. 0031-9155 42, 1-39 (1997). 10.1088/0031-9155/42/1/001 (Pubitemid 27055950)
    • (1997) Physics in Medicine and Biology , vol.42 , Issue.1 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 30
    • 21344469732 scopus 로고    scopus 로고
    • A search for optimal x-ray spectra in iodine contrast media mammography
    • DOI 10.1088/0031-9155/50/13/012
    • G. Ullman, M. Sandborg, D. R. Dance, M. Yaffe, and G. Alm Carlsson, " A search for optimal x-ray spectra in iodine contrast media mammography.," Phys. Med. Biol. 0031-9155 50, 3143-3152 (2005). 10.1088/0031-9155/50/13/012 (Pubitemid 40905190)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.13 , pp. 3143-3152
    • Ullman, G.1    Sandborg, M.2    Dance, D.R.3    Yaffe, M.4    Carlsson, G.A.5
  • 32
    • 34347399809 scopus 로고    scopus 로고
    • Physical characteristics of five clinical systems for digital mammography
    • DOI 10.1118/1.2742498
    • B. Lazzari, G. Belli, C. Gori, and M. R. Del Turco, " Physical characteristics of five clinical systems for digital mammography.," Med. Phys. 0094-2405 34, 2730-2743 (2007). 10.1118/1.2742498 (Pubitemid 47019794)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2730-2743
    • Lazzari, B.1    Belli, G.2    Gori, C.3    Del Turco, M.R.4
  • 33
    • 0033868220 scopus 로고    scopus 로고
    • Direct measurement of mammographic x-ray spectra using a CdZnTe detector
    • DOI 10.1118/1.599015
    • M. Matsumoto, A. Yamamoto, I. Honda, A. Taniguchi, and H. Kanamori, " Direct measurement of mammographic x-ray spectra using a CdZnTe detector.," Med. Phys. 0094-2405 27, 1490-1502 (2000). 10.1118/1.599015 (Pubitemid 30624244)
    • (2000) Medical Physics , vol.27 , Issue.7 , pp. 1490-1502
    • Matsumoto, M.1    Yamamoto, A.2    Honda, I.3    Taniguchi, A.4    Kanamori, H.5
  • 34
    • 0035996550 scopus 로고    scopus 로고
    • CdZnTe detector in diagnostic x-ray spectroscopy
    • DOI 10.1118/1.1485975
    • S. Miyajima, K. Imagawa, and M. Matsumoto, " CdZnTe detector in diagnostic x-ray spectroscopy.," Med. Phys. 0094-2405 29, 1421-1429 (2002). 10.1118/1.1485975 (Pubitemid 34774573)
    • (2002) Medical Physics , vol.29 , Issue.7 , pp. 1421-1429
    • Miyajima, S.1    Imagawa, K.2    Matsumoto, M.3
  • 35
    • 33645505957 scopus 로고    scopus 로고
    • Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system
    • 0094-2405,. 10.1118/1.2184445
    • S. Z. Shen, A. K. Bloomquist, G. E. Mawdsley, M. J. Yaffe, and I. Elbakri, " Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system.," Med. Phys. 0094-2405 33, 1108-1115 (2006). 10.1118/1.2184445
    • (2006) Med. Phys. , vol.33 , pp. 1108-1115
    • Shen, S.Z.1    Bloomquist, A.K.2    Mawdsley, G.E.3    Yaffe, M.J.4    Elbakri, I.5
  • 36
    • 33746617894 scopus 로고    scopus 로고
    • Lag and ghosting in a clinical flat-panel selenium digital mammography system
    • DOI 10.1118/1.2218315
    • A. K. Bloomquist, M. J. Yaffe, G. E. Mawdsley, D. M. Hunter, and D. J. Beideck, " Lag and ghosting in a clinical flat-panel selenium digital mammography system.," Med. Phys. 0094-2405 33, 2998-3005 (2006). 10.1118/1.2218315 (Pubitemid 44154572)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2998-3005
    • Bloomquist, A.K.1    Yaffe, M.J.2    Mawdsley, G.E.3    Hunter, D.M.4    Beideck, D.J.5
  • 38
    • 34447317285 scopus 로고    scopus 로고
    • Calculation of x-ray spectra emerging from an x-ray tube. Part I. Electron penetration characteristics in x-ray targets
    • DOI 10.1118/1.2734725
    • G. G. Poludniowski and P. M. Evans, " Calculation of x-ray spectra emerging from an x-ray tube. Part I. Electron penetration characteristics in x-ray targets.," Med. Phys. 0094-2405 34, 2164-2174 (2007). 10.1118/1.2734725 (Pubitemid 47055751)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2164-2174
    • Poludniowski, G.G.1    Evans, P.M.2
  • 39
    • 34447320794 scopus 로고    scopus 로고
    • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets
    • DOI 10.1118/1.2734726
    • G. G. Poludniowski, " Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.," Med. Phys. 0094-2405 34, 2175-2186 (2007). 10.1118/1.2734726 (Pubitemid 47055752)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2175-2186
    • Poludniowski, G.G.1
  • 40
    • 26644444613 scopus 로고    scopus 로고
    • edited by A. G. Griesbeck and J. Mattay (CRC / Dekker, New York), Vol..
    • Synthetic Organic Photochemistry, edited by, A. G. Griesbeck, and, J. Mattay, (CRC / Dekker, New York, 2004), Vol. 12.
    • (2004) Synthetic Organic Photochemistry , vol.12
  • 41
    • 0017692845 scopus 로고
    • Epoxy resin based tissue substitutes
    • 0007-1285,. 10.1259/0007-1285-50-599-814
    • D. R. White, R. J. Martin, and R. Darlison, " Epoxy resin based tissue substitutes.," Br. J. Radiol. 0007-1285 50, 814-821 (1977). 10.1259/0007-1285-50-599-814
    • (1977) Br. J. Radiol. , vol.50 , pp. 814-821
    • White, D.R.1    Martin, R.J.2    Darlison, R.3
  • 42
    • 0032914531 scopus 로고    scopus 로고
    • New low-contrast resolution phantoms for computed tomography
    • DOI 10.1118/1.598516
    • C. Suess, W. A. Kalender, and J. M. Coman, " New low-contrast resolution phantoms for computed tomography.," Med. Phys. 0094-2405 26, 296-302 (1999). 10.1118/1.598516 (Pubitemid 29094260)
    • (1999) Medical Physics , vol.26 , Issue.2 , pp. 296-302
    • Suess, C.1    Kalender, W.A.2    Coman, J.M.3
  • 43
    • 0036236361 scopus 로고    scopus 로고
    • Detection of low-contrast objects: Experimental comparison of single- and multi-detector row CT with a phantom
    • 0033-8419,. 10.1148/radiol.2232010810
    • F. R. Verdun, A. Denys, J. F. Valley, P. Schnyder, and R. A. Meuli, " Detection of low-contrast objects: Experimental comparison of single- and multi-detector row CT with a phantom.," Radiology 0033-8419 223, 426-431 (2002). 10.1148/radiol.2232010810
    • (2002) Radiology , vol.223 , pp. 426-431
    • Verdun, F.R.1    Denys, A.2    Valley, J.F.3    Schnyder, P.4    Meuli, R.A.5
  • 45
    • 22844451841 scopus 로고    scopus 로고
    • Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation
    • DOI 10.1097/01.rli.0000170628.69792.cb
    • T. C. Gerber, B. P. Stratmann, R. S. Kuzo, B. Kantor, and R. L. Morin, " Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation.," Invest. Radiol. 0020-9996 40, 556-563 (2005). 10.1097/01.rli.0000170628.69792.cb (Pubitemid 41040693)
    • (2005) Investigative Radiology , vol.40 , Issue.8 , pp. 556-563
    • Gerber, T.C.1    Stratmann, B.P.2    Kuzo, R.S.3    Kantor, B.4    Morin, R.L.5
  • 46
    • 34548421567 scopus 로고    scopus 로고
    • A comparative study of thoracic radiation doses from 64-slice cardiac CT
    • DOI 10.1259/bjr/34603706
    • E. L. Nickoloff and P. O. Alderson, " A comparative study of thoracic radiation doses from 64-slice cardiac CT.," Br. J. Radiol. 0007-1285 80, 537-544 (2007). 10.1259/bjr/34603706 (Pubitemid 47351081)
    • (2007) British Journal of Radiology , vol.80 , Issue.955 , pp. 537-544
    • Nickoloff, E.L.1    Alderson, P.O.2
  • 48
    • 70349674442 scopus 로고    scopus 로고
    • The Phantom Laboratory, (The Phantom Laboratory, Salem, NY)
    • The Phantom Laboratory, Catphan 500 and 600 Manual (The Phantom Laboratory, Salem, NY, 2009).
    • (2009) Catphan 500 and 600 Manual
  • 49
    • 0035989948 scopus 로고    scopus 로고
    • Direct conversion detectors: The effect of incomplete charge collection on detective quantum efficiency
    • DOI 10.1118/1.1477235
    • J. G. Mainprize, D. C. Hunt, and M. J. Yaffe, " Direct conversion detectors: The effect of incomplete charge collection on detective quantum efficiency.," Med. Phys. 0094-2405 29, 976-990 (2002). 10.1118/1.1477235 (Pubitemid 34670524)
    • (2002) Medical Physics , vol.29 , Issue.6 , pp. 976-990
    • Mainprize, J.G.1    Hunt, D.C.2    Yaffe, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.