Volumn 27, Issue 7, 2000, Pages 1490-1502

Direct measurement of mammographic x-ray spectra using a CdZnTe detector

Author keywords

Attenuation curve; CdZnTe detector; Direct measurement; Mammography; X ray spectrum

Indexed keywords

CADMIUM ALLOYS; COHERENT SCATTERING; COMPTON SCATTERING; II-VI SEMICONDUCTORS; IONIZATION CHAMBERS; MAMMOGRAPHY; MOLYBDENUM; MONTE CARLO METHODS; PHOTOIONIZATION; PHOTONS; SEMICONDUCTOR ALLOYS; X RAY SPECTROGRAPHS; X RAYS; ZINC ALLOYS;

EID: 0033868220     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.599015     Document Type: Article
Times cited : (59)

References (22)
  • 1
    • 0015784807 scopus 로고
    • Computed spectra from diagnostic and therapeutic x-ray tubes
    • V. Sundararaman, M. A. Prasad, and R. B. Vora, "Computed spectra from diagnostic and therapeutic x-ray tubes," Phys. Med. Biol. 18(2), 208-218 (1973).
    • (1973) Phys. Med. Biol. , vol.18 , Issue.2 , pp. 208-218
    • Sundararaman, V.1    Prasad, M.A.2    Vora, R.B.3
  • 2
  • 3
    • 0019422478 scopus 로고
    • X-ray spectra vs attenuation data
    • L. C. Baird, "X-ray spectra vs attenuation data," Med. Phys. 8(3), 319-323 (1981).
    • (1981) Med. Phys. , vol.8 , Issue.3 , pp. 319-323
    • Baird, L.C.1
  • 4
    • 0020362553 scopus 로고
    • A Laplace transform pair model for spectral reconstruction
    • B. R. Archer and L. K. Wagner, "A Laplace transform pair model for spectral reconstruction," Med. Phys. 9(6), 844-847 (1982).
    • (1982) Med. Phys. , vol.9 , Issue.6 , pp. 844-847
    • Archer, B.R.1    Wagner, L.K.2
  • 5
    • 0021024554 scopus 로고
    • Determination of x-ray spectral distribution from transmission measurements using K-edge filters
    • K. Chu and A. Fenster, "Determination of x-ray spectral distribution from transmission measurements using K-edge filters," Med. Phys. 10(6), 772-777 (1983).
    • (1983) Med. Phys. , vol.10 , Issue.6 , pp. 772-777
    • Chu, K.1    Fenster, A.2
  • 6
    • 33744678148 scopus 로고
    • Bremsstrahlung emission measurement from thick tungsten targets in the energy range 12 to 300 keV
    • UC-34, Physics, TID-4500
    • E. Storm, H. I. Israel, and D. W. Lier, "Bremsstrahlung emission measurement from thick tungsten targets in the energy range 12 to 300 keV," Los Alamos Scientific Laboratory Report LA-4624, UC-34, Physics, TID-4500 (1971).
    • (1971) Los Alamos Scientific Laboratory Report LA-4624
    • Storm, E.1    Israel, H.I.2    Lier, D.W.3
  • 7
    • 49649147616 scopus 로고
    • Comparison of detectors used in measurement of 10 to 300 keV x-ray spectra
    • H. I. Israel, D. W. Lier, and E. Storm, "Comparison of detectors used in measurement of 10 to 300 keV x-ray spectra," Nucl. Instrum. Methods 91, 141-157 (1971).
    • (1971) Nucl. Instrum. Methods , vol.91 , pp. 141-157
    • Israel, H.I.1    Lier, D.W.2    Storm, E.3
  • 8
    • 0018751365 scopus 로고
    • Stripping of x-ray bremsstrahlung spectra up to 300 kVp on a desk type computer
    • W. W. Seelentag and W. Panzer, "Stripping of x-ray bremsstrahlung spectra up to 300 kVp on a desk type computer," Phys. Med. Biol. 24, 767-780 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , pp. 767-780
    • Seelentag, W.W.1    Panzer, W.2
  • 9
    • 0018399326 scopus 로고
    • Computation of bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector
    • R. Birch and M. Marshall, "Computation of Bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector," Phys. Med. Biol. 24(3), 505-517 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , Issue.3 , pp. 505-517
    • Birch, R.1    Marshall, M.2
  • 12
    • 85027229231 scopus 로고
    • Measurement of diagnostic x-ray spectra with small-capacity high-voltage cables
    • H. Kanamori, M. Matsumoto, and N. Nakamori, "Measurement of diagnostic x-ray spectra with small-capacity high-voltage cables," Med. Biol. Eng. Comput. 23, Suppl. Part 2 1334-1335 (1985).
    • (1985) Med. Biol. Eng. Comput. , vol.23 , Issue.SUPPL. PART 2 , pp. 1334-1335
    • Kanamori, H.1    Matsumoto, M.2    Nakamori, N.3
  • 13
    • 0025941633 scopus 로고
    • Effects of voltage ripple and current mode on diagnostic x-ray spectra and exposures
    • M. Matsumoto, H. Kubota, H. Hayashi, and H. Kanamori, "Effects of voltage ripple and current mode on diagnostic x-ray spectra and exposures," Med. Phys. 18, 921-927 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 921-927
    • Matsumoto, M.1    Kubota, H.2    Hayashi, H.3    Kanamori, H.4
  • 14
    • 0028860322 scopus 로고
    • Experimental verification of the reverse order of diagnostic x-ray beam quality in their voltage-ripple dependence
    • M. Matsumoto, H. Kubota, Y. Ozaki, and H. Kanamori, "Experimental verification of the reverse order of diagnostic x-ray beam quality in their voltage-ripple dependence," Med. Biol. Eng. Comput. 33, 48-51 (1995).
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 48-51
    • Matsumoto, M.1    Kubota, H.2    Ozaki, Y.3    Kanamori, H.4
  • 15
    • 0027328328 scopus 로고
    • Effects of x-ray tube-voltage ripple and current mode on patient dose
    • H. Kubota, Y. Ozaki, M. Matsumoto, and H. Kanamori, "Effects of x-ray tube-voltage ripple and current mode on patient dose," Med. Phys. 20, 1023-1028 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1023-1028
    • Kubota, H.1    Ozaki, Y.2    Matsumoto, M.3    Kanamori, H.4
  • 16
    • 0028467466 scopus 로고
    • Experimental separation of diagnostic x-ray spectra into scatter and primary components
    • H. Kubota, Y. Ozaki, M. Matsumoto, and H. Kanamori, "Experimental separation of diagnostic x-ray spectra into scatter and primary components," Med. Biol. Eng. Comput. 32, 468-472 (1994).
    • (1994) Med. Biol. Eng. Comput. , vol.32 , pp. 468-472
    • Kubota, H.1    Ozaki, Y.2    Matsumoto, M.3    Kanamori, H.4
  • 17
    • 0021237558 scopus 로고
    • The use of cadmium telluride detectors for the qualitative analysis of diagnostic x-ray spectra
    • E. Di, Castro, R. Pani, R. Pellegrini, and C. Bacci, "The use of cadmium telluride detectors for the qualitative analysis of diagnostic x-ray spectra," Phys. Med. Biol. 29, 1117-1131 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1117-1131
    • Di Castro, E.1    Pani, R.2    Pellegrini, R.3    Bacci, C.4
  • 18
    • 33744595493 scopus 로고    scopus 로고
    • Direct measurement of mammographic x-ray spectra
    • M. Matsumoto, H. Kanamori, A. Taniguchi, and M. Yoshida, "Direct measurement of mammographic x-ray spectra," Med. Phys. 24(6), 1026 (1997).
    • (1997) Med. Phys. , vol.24 , Issue.6 , pp. 1026
    • Matsumoto, M.1    Kanamori, H.2    Taniguchi, A.3    Yoshida, M.4
  • 19
    • 0019174427 scopus 로고
    • Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra
    • C. S. Chen, K. Doi, C. Vyborny, H-P. Chan, and G. Holje, "Monte Carlo simulation studies of detectors used in the measurement of diagnostic x-ray spectra," Med. Phys. 7(6), 627-635 (1980).
    • (1980) Med. Phys. , vol.7 , Issue.6 , pp. 627-635
    • Chen, C.S.1    Doi, K.2    Vyborny, C.3    Chan, H.-P.4    Holje, G.5
  • 20
    • 0041559622 scopus 로고
    • Energy responses of germanium planar detectors used measurement of x-ray spectra in the energy range from 12 to 300 keV: Monte Carlo simulation studies
    • University of Chicago
    • C-T. Chen, H-P. Chan, and K. Doi, Energy responses of germanium planar detectors used measurement of x-ray spectra in the energy range from 12 to 300 keV: Monte Carlo simulation studies, Research Report UCHI-DR/84-01 (University of Chicago 1984).
    • (1984) Research Report UCHI-DR/84-01
    • Chen, C.-T.1    Chan, H.-P.2    Doi, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.