Novel materials for low-contrast phantoms for computed tomography

Author keywords

Atomic number; Computed tomography; Contrast; Density; Low contrast performance; Phantoms

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DENSITY (OPTICAL); GLYCEROL; POLYSTYRENES; RESINS;

EID: 33947532649     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (12)
  • 2
    • 0033849806 scopus 로고    scopus 로고
    • A variable resolution x-ray detector for CT: I. Theoretical basis and experimental verification
    • F.A. DiBianca and V. Gupta, A variable resolution x-ray detector for CT: I. Theoretical basis and experimental verification, Medical Physics 27(8) (2000), 1865-1874.
    • (2000) Medical Physics , vol.27 , Issue.8 , pp. 1865-1874
    • DiBianca, F.A.1    Gupta, V.2
  • 3
    • 0033849839 scopus 로고    scopus 로고
    • A variable resolution x-ray detector for CT: II. Imaging theory and performance
    • F.A. DiBianca, P. Zou, L.M. Jordan, J.S. Laughter and H.D. Zeman, A variable resolution x-ray detector for CT: II. Imaging theory and performance, Medical Physics 27(8) (2000), 1875-1880.
    • (2000) Medical Physics , vol.27 , Issue.8 , pp. 1875-1880
    • DiBianca, F.A.1    Zou, P.2    Jordan, L.M.3    Laughter, J.S.4    Zeman, H.D.5
  • 5
    • 33947516298 scopus 로고    scopus 로고
    • Specification and Acceptance Testing Of Computed Tomography Scanners. AAPM Report No. 39, American Institute of Physics, New York, NY 1993
    • Specification and Acceptance Testing Of Computed Tomography Scanners. AAPM Report No. 39, American Institute of Physics, New York, NY 1993.
  • 6
    • 0029145191 scopus 로고
    • Toward consensus on quantitative assessment of medical imaging systems
    • Jul
    • C.E. Metz, R.F. Wagner, K. Doi, D.G. Brown, R.M. Nishikawa and K.J. Myers, Toward consensus on quantitative assessment of medical imaging systems, Medical Physics 22(7) (Jul. 1995), 1057-1061.
    • (1995) Medical Physics , vol.22 , Issue.7 , pp. 1057-1061
    • Metz, C.E.1    Wagner, R.F.2    Doi, K.3    Brown, D.G.4    Nishikawa, R.M.5    Myers, K.J.6
  • 7
    • 0021493640 scopus 로고
    • Factors related to low contrast resolution in CT scanners
    • Sep
    • D.J. Goodenough and K.E. Weaver, Factors related to low contrast resolution in CT scanners, Computerized Radiology 8(5) (Sep. 1984), 297-308.
    • (1984) Computerized Radiology , vol.8 , Issue.5 , pp. 297-308
    • Goodenough, D.J.1    Weaver, K.E.2
  • 8
    • 0018357627 scopus 로고
    • The Use of Contrast-Detail-Dose Evaluation of Image Quality in a Computed Tomographic Scanner
    • G. Cohen and F.A. DiBianca, The Use of Contrast-Detail-Dose Evaluation of Image Quality in a Computed Tomographic Scanner, Journal of Computed Assisted Tomography 3(2) (1979), 189-195.
    • (1979) Journal of Computed Assisted Tomography , vol.3 , Issue.2 , pp. 189-195
    • Cohen, G.1    DiBianca, F.A.2
  • 11
    • 33947537251 scopus 로고    scopus 로고
    • Tomoscan LX Technical Documents Release 1.0, Phillips Medical Systems, 1991
    • Tomoscan LX Technical Documents Release 1.0, Phillips Medical Systems, 1991.
  • 12
    • 0021336242 scopus 로고
    • Digital Image Processing: Effect on Detectability of Simulated Low-Contrast Radiographic Patterns
    • M. Ishida, K. Doi, L.-N. Loo, C.E. Metz and J.L. Lehr, Digital Image Processing: Effect on Detectability of Simulated Low-Contrast Radiographic Patterns, Radiology 150 (1984), 569-575.
    • (1984) Radiology , vol.150 , pp. 569-575
    • Ishida, M.1    Doi, K.2    Loo, L.-N.3    Metz, C.E.4    Lehr, J.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.