메뉴 건너뛰기




Volumn 36, Issue 10, 2009, Pages 4486-4494

RBE estimation of proton radiation fields using a Δe-E telescope

Author keywords

Microdosimetry; Proton therapy; RBE

Indexed keywords

CHARGED PARTICLES; HADRONS; PHANTOMS; POSITRON EMISSION TOMOGRAPHY; PROTON BEAMS; TELESCOPES;

EID: 70349678713     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3215927     Document Type: Article
Times cited : (20)

References (36)
  • 3
    • 0028313985 scopus 로고
    • Radiobiological effectiveness of radiation beams with broad let spectra-Microdosimetric analysis using biological weighting functions
    • 0144-8420.
    • T. Loncol, " Radiobiological effectiveness of radiation beams with broad let spectra-Microdosimetric analysis using biological weighting functions.," Radiat. Prot. Dosim. 0144-8420 52, 347-352 (1994).
    • (1994) Radiat. Prot. Dosim. , vol.52 , pp. 347-352
    • Loncol, T.1
  • 4
    • 84869636354 scopus 로고
    • ICRU, "Microdosimetry," Report No. 36.
    • ICRU, "Microdosimetry," Report No. 36, 1983.
    • (1983)
  • 6
    • 0028521381 scopus 로고
    • Relative biological effectiveness and microdosimetry of a mixed energy field of protons up to 200 MeV
    • 0273-1177,. 10.1016/0273-1177(94)90477-4
    • J. B. Robertson, " Relative biological effectiveness and microdosimetry of a mixed energy field of protons up to 200 MeV.," Adv. Space Res. 0273-1177 14, 271-275 (1994). 10.1016/0273-1177(94)90477-4
    • (1994) Adv. Space Res. , vol.14 , pp. 271-275
    • Robertson, J.B.1
  • 8
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-a simulation toolkit
    • 0168-9002 (),. 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli, " GEANT4-a simulation toolkit.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 506 (3), 250-303 (2003). 10.1016/S0168-9002(03) 01368-8
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.506 , Issue.3 , pp. 250-303
    • Agostinelli, S.1
  • 9
    • 3242675283 scopus 로고    scopus 로고
    • Monolithic silicon E-Delta e telescope produced by the quasi-selective epitaxy
    • 0168-9002 (),. 10.1016/j.nima.2004.02.034
    • A. J. Kordyasz, " Monolithic silicon E-Delta E telescope produced by the quasi-selective epitaxy.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 528 (3), 721-730 (2004). 10.1016/j.nima.2004.02.034
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.528 , Issue.3 , pp. 721-730
    • Kordyasz, A.J.1
  • 12
    • 4243131359 scopus 로고    scopus 로고
    • Response to heavy ions and fission fragments of the monolithic silicon E-delta e telescopes produced by the quasi-selective epitaxy
    • 0168-9002 (),. 10.1016/j.nima.2004.05.053
    • A. J. Kordyasz, " Response to heavy ions and fission fragments of the monolithic silicon E-delta E telescopes produced by the quasi-selective epitaxy.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 530 (1-2), 87-91 (2004). 10.1016/j.nima.2004.05.053
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.530 , Issue.12 , pp. 87-91
    • Kordyasz, A.J.1
  • 16
  • 17
    • 33645686854 scopus 로고    scopus 로고
    • A micrometric thickness silicon diode proposed as a microdosimeter
    • 0018-9499 (),. 10.1109/TNS.2006.869832
    • A. Fazzi, " A micrometric thickness silicon diode proposed as a microdosimeter.," IEEE Trans. Nucl. Sci. 0018-9499 53 (1), 312-316 (2006). 10.1109/TNS.2006.869832
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.1 , pp. 312-316
    • Fazzi, A.1
  • 18
    • 46549085542 scopus 로고    scopus 로고
    • A pixelated silicon telescope for solid state microdosimetry
    • 1350-4487 (),. 10.1016/j.radmeas.2007.12.053
    • S. Agosteo, P. G. Fallica, A. Fazzi, " A pixelated silicon telescope for solid state microdosimetry.," Radiat. Meas. 1350-4487 43 (2-6), 585-589 (2008). 10.1016/j.radmeas.2007.12.053
    • (2008) Radiat. Meas. , vol.43 , Issue.26 , pp. 585-589
    • Agosteo, S.1    Fallica, P.G.2    Fazzi, A.3
  • 19
    • 85027217889 scopus 로고    scopus 로고
    • NIST, National Institute of Standards and Technology PSTAR Database Program.
    • NIST, National Institute of Standards and Technology PSTAR Database Program, http://physics.nist.gov/PhysRefData/Star/Text/PSTAR.html.
  • 20
    • 0040138724 scopus 로고
    • Radiological use of fast protons
    • 0033-8419.
    • R. R. Wilson, " Radiological use of fast protons.," Radiology 0033-8419 47, 487-491 (1946).
    • (1946) Radiology , vol.47 , pp. 487-491
    • Wilson, R.R.1
  • 21
    • 0037034088 scopus 로고    scopus 로고
    • Dosimetry system for the irradiation of thin biological samples with therapeutic proton beams
    • DOI 10.1088/0031-9155/47/3/304, PII S0031915502285607
    • V. Bashkirov and R. W. Schulte, " Dosimetry system for the irradiation of thin biological samples with therapeutic proton beams.," Phys. Med. Biol. 0031-9155 47, 409-420 (2002). 10.1088/0031-9155/47/3/304 (Pubitemid 34141350)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.3 , pp. 409-420
    • Bashkirov, V.1    Schulte, R.W.2
  • 22
    • 0025723455 scopus 로고
    • A prototype beam delivery system for the proton medical accelerator at Loma-Linda
    • 0094-2405,. 10.1118/1.596617
    • G. Coutrakon, " A prototype beam delivery system for the proton medical accelerator at Loma-Linda.," Med. Phys. 0094-2405 18, 1093-1099 (1991). 10.1118/1.596617
    • (1991) Med. Phys. , vol.18 , pp. 1093-1099
    • Coutrakon, G.1
  • 25
    • 33144478340 scopus 로고    scopus 로고
    • Detailed analysis of the cell-inactivation mechanism by accelerated protons and light ions
    • DOI 10.1088/0031-9155/51/5/010, PII S0031915506073684
    • P. Kundrat, " Detailed analysis of the cell-inactivation mechanism by accelerated protons and light ions.," Phys. Med. Biol. 0031-9155 51, 1185-1199 (2006). 10.1088/0031-9155/51/5/010 (Pubitemid 43267188)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.5 , pp. 1185-1199
    • Kundrat, P.1
  • 26
    • 33846855999 scopus 로고    scopus 로고
    • A nanodosimetry-based linear-quadratic model of cell survival for mixed-LET radiations
    • DOI 10.1088/0031-9155/51/23/010, PII S0031915506277236, 010
    • C. K. C. Wang and X. Zhang, " A nanodosimetry-based linear-quadratic model of cell survival for mixed-LET radiations.," Phys. Med. Biol. 0031-9155 51, 6087-6098 (2006). 10.1088/0031-9155/51/23/010 (Pubitemid 46217651)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.23 , pp. 6087-6098
    • Chris Wang, C.-K.1    Zhang, X.2
  • 27
    • 0032700567 scopus 로고    scopus 로고
    • RBE for carbon track-segment irradiation in cell lines of differing repair capacity
    • 0955-3022,. 10.1080/095530099139232
    • W. K. Weyrather, " RBE for carbon track-segment irradiation in cell lines of differing repair capacity.," Int. J. Radiat. Biol. 0955-3022 75, 1357-1364 (1999). 10.1080/095530099139232
    • (1999) Int. J. Radiat. Biol. , vol.75 , pp. 1357-1364
    • Weyrather, W.K.1
  • 32
    • 0026740390 scopus 로고
    • Direct comparison between protons and alpha-particles of the same let. 1. Irradiation methods and inactivation of asynchronous V79, Hela and C3h 10t1/2 cells
    • 0955-3022,. 10.1080/09553009214551421
    • D. T. Goodhead, " Direct comparison between protons and alpha-particles of the same let. 1. Irradiation methods and inactivation of asynchronous V79, Hela and C3h 10t1/2 cells.," Int. J. Radiat. Biol. 0955-3022 61, 611-624 (1992). 10.1080/09553009214551421
    • (1992) Int. J. Radiat. Biol. , vol.61 , pp. 611-624
    • Goodhead, D.T.1
  • 34
    • 3442895110 scopus 로고    scopus 로고
    • A phenomenological model for the relative biological effectiveness in therapeutic proton beams
    • DOI 10.1088/0031-9155/49/13/004, PII S0031915504749842
    • J. J. Wilkens and U. Oelfke, " A phenomenological model for the relative biological effectiveness in therapeutic proton beams.," Phys. Med. Biol. 0031-9155 49, 2811-2825 (2004). 10.1088/0031-9155/49/13/004 (Pubitemid 39004134)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.13 , pp. 2811-2825
    • Wilkens, J.J.1    Oelfke, U.2
  • 35
    • 4644338631 scopus 로고    scopus 로고
    • Microdosimetric investigation at the therapeutic proton beam facility of Catana
    • DOI 10.1093/rpd/nch111, Advances in Nuclear Particle Dosimetry for Radiation Protection and Medicine
    • L. De Nardo, " Microdosimetric investigation at the therapeutic proton beam facility of CATANA.," Radiat. Prot. Dosim. 0144-8420 110, 681-686 (2004). 10.1093/rpd/nch111 (Pubitemid 39276816)
    • (2004) Radiation Protection Dosimetry , vol.110 , Issue.1-4 , pp. 681-686
    • De Nardo, L.1    Moro, D.2    Colautti, P.3    Conte, V.4    Tornielli, G.5    Cuttone, G.6
  • 36
    • 0030942892 scopus 로고    scopus 로고
    • Microdosimetric studies on the Orsay proton synchrocyclotron at 73 and 200 MeV
    • 0144-8420.
    • V. P. Cosgrove, " Microdosimetric studies on the Orsay proton synchrocyclotron at 73 and 200 MeV.," Radiat. Prot. Dosim. 0144-8420 70, 493-496 (1997).
    • (1997) Radiat. Prot. Dosim. , vol.70 , pp. 493-496
    • Cosgrove, V.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.