메뉴 건너뛰기




Volumn 63, Issue 5-6 SPEC. ISS., 2005, Pages 529-535

A feasibility study of a solid-state microdosimeter

Author keywords

Microdosimetry; Neutrons; Semiconductor detectors

Indexed keywords

CHARGE CARRIERS; COMPUTER SIMULATION; DATA ACQUISITION; DOSIMETERS; ENERGY ABSORPTION; NEUTRONS; SEMICONDUCTOR MATERIALS; SILICON;

EID: 26444507958     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2005.05.001     Document Type: Conference Paper
Times cited : (26)

References (15)
  • 3
    • 26444545358 scopus 로고    scopus 로고
    • Secondary photon fields produced in accelerator-based sources for neutron generation
    • ICRS10, Madeira, Portugal, 9-14 May 2004, proceedings in press.
    • Agosteo, S., Cesana, A., Garlati, L., Pola, A., Terrani, M., 2004. Secondary photon fields produced in accelerator-based sources for neutron generation. 10th International Conference on Radiation Shielding, ICRS10, Madeira, Portugal, 9-14 May 2004, proceedings in press.
    • (2004) 10th International Conference on Radiation Shielding
    • Agosteo, S.1    Cesana, A.2    Garlati, L.3    Pola, A.4    Terrani, M.5
  • 5
    • 0032976612 scopus 로고    scopus 로고
    • Performance of silicon microdosimetry detectors in boron neutron capture therapy
    • P.D. Bradley, A.B. Rosenfeld, B.J. Allen, J. Coderre, and J. Capala Performance of silicon microdosimetry detectors in boron neutron capture therapy Radiat. Res. 151 1999 235 243
    • (1999) Radiat. Res. , vol.151 , pp. 235-243
    • Bradley, P.D.1    Rosenfeld, A.B.2    Allen, B.J.3    Coderre, J.4    Capala, J.5
  • 6
    • 0019204770 scopus 로고
    • A comparison of microdosimetric measurements with spherical proportional counters and solid-state detectors
    • J.F. Dicello, H.I. Amols, M. Zaider, and G. Tripard A comparison of microdosimetric measurements with spherical proportional counters and solid-state detectors Radiat. Res. 82 1980 441 453
    • (1980) Radiat. Res. , vol.82 , pp. 441-453
    • Dicello, J.F.1    Amols, H.I.2    Zaider, M.3    Tripard, G.4
  • 9
    • 0019551234 scopus 로고
    • A field funnelling effect on collection of alpha-particle-generated carriers in silicon devices
    • C.M. Hsieh, P.C. Murley, and R.R. O'Brien A field funnelling effect on collection of alpha-particle-generated carriers in silicon devices IEEE Electron Device Lett. EDL-2 1981 103 105
    • (1981) IEEE Electron Device Lett. , vol.2 , pp. 103-105
    • Hsieh, C.M.1    Murley, P.C.2    O'Brien, R.R.3
  • 10
    • 0028216928 scopus 로고
    • Perfomance of PIN photodiode in microdosimetry
    • A. Kadachi, A. Waheed, and M. Obeid Perfomance of PIN photodiode in microdosimetry Health Phys. 66 1994 577 580
    • (1994) Health Phys. , vol.66 , pp. 577-580
    • Kadachi, A.1    Waheed, A.2    Obeid, M.3
  • 11
    • 0032003371 scopus 로고    scopus 로고
    • Use of photodiode in microdosimetry and evaluation of effective quality factor
    • A. Kadachi, A. Waheed, M. Al-Eshaikh, and M. Obeid Use of photodiode in microdosimetry and evaluation of effective quality factor Nucl. Instrum. Methods A 404 1998 400 406
    • (1998) Nucl. Instrum. Methods a , vol.404 , pp. 400-406
    • Kadachi, A.1    Waheed, A.2    Al-Eshaikh, M.3    Obeid, M.4
  • 12
    • 0024789561 scopus 로고
    • Microdosimetric counters based on semiconductors detectors
    • M. Orlic, V. Lazarevic, and F. Boreli Microdosimetric counters based on semiconductors detectors Radiat. Prot. Dosim. 29 1989 21 22
    • (1989) Radiat. Prot. Dosim. , vol.29 , pp. 21-22
    • Orlic, M.1    Lazarevic, V.2    Boreli, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.