메뉴 건너뛰기




Volumn 24, Issue 2, 2009, Pages 325-334

Technique for placement of oxidized titanium implants in compromised maxillary bone: Prospective study of 290 implants in 126 consecutive patients followed for a minimum of 3 years after loading

(1)  Bahat, Oded a  

a NONE   (United States)

Author keywords

Bone grafts; Bone quality; Dental implants; Marginal bone; Titanium oxide

Indexed keywords

TITANIUM;

EID: 69849111007     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (27)

References (40)
  • 1
    • 15944426386 scopus 로고    scopus 로고
    • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: An in vivo study
    • Goransson A, Wennerberg A. Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: An in vivo study.Clin Implant Dent Relat Res 2005;7:17-23.
    • (2005) Clin Implant Dent Relat Res , vol.7 , pp. 17-23
    • Goransson, A.1    Wennerberg, A.2
  • 2
    • 0042420626 scopus 로고    scopus 로고
    • A histomor- phometric analysis of the effects of various surface treatment methods on osseointegration
    • Kim YH, Koak JY, Chang IT, Wennerberg A, Heo SJ. A histomor- phometric analysis of the effects of various surface treatment methods on osseointegration. Int J Oral Maxillofac Implants 2003;18:349-356.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 349-356
    • Kim, Y.H.1    Koak, J.Y.2    Chang, I.T.3    Wennerberg, A.4    Heo, S.J.5
  • 3
  • 5
    • 0042961805 scopus 로고    scopus 로고
    • Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative study using resonance frequency analysis
    • Glauser R, Portmann M, Ruhstaller P, Lundgren A, Hammerle CH, Gottlow J. Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative study using resonance frequency analysis. Appl Osseointegration Res 2001;2:27-29.
    • (2001) Appl Osseointegration Res , vol.2 , pp. 27-29
    • Glauser, R.1    Portmann, M.2    Ruhstaller, P.3    Lundgren, A.4    Ch, H.5    Gottlow, J.6
  • 6
    • 0002533641 scopus 로고    scopus 로고
    • Removal torque comparison of TiUnite and turned implants in the greyhound dog mandible
    • Henry P, Tan A, Allan B, Hall J, Johansson C. Removal torque comparison of TiUnite and turned implants in the greyhound dog mandible. Appl Osseointegration Res 2000;1:15-17.
    • (2000) Appl Osseointegration Res , vol.1 , pp. 15-17
    • Henry, P.1    Tan, A.2    Allan, B.3    Hall, J.4    Johansson, C.5
  • 7
    • 0043014563 scopus 로고    scopus 로고
    • Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in the posterior mandible
    • Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in the posterior mandible. Clin Implant Dent Relat Res 2003;5(suppl 1):88-98.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 88-98
    • Rocci, A.1    Martignoni, M.2    Burgos, P.M.3    Gottlow, J.4    Sennerby, L.5
  • 8
    • 5444256535 scopus 로고    scopus 로고
    • Immediate loading of a Brȧnemark System implant with the TiUnite surface. Histological evaluation after 9 months
    • Rocci A, Martignoni M, Sennerby L, Gottlow J. Immediate loading of a Brȧnemark System implant with the TiUnite surface. Histological evaluation after 9 months. Appl Osseointegration Res 2002;3:25-28.
    • (2002) Appl Osseointegration Res , vol.3 , pp. 25-28
    • Rocci, A.1    Martignoni, M.2    Sennerby, L.3    Gottlow, J.4
  • 9
    • 0041960114 scopus 로고    scopus 로고
    • Stability measurements of a double-threaded titanium implant design with turned or oxidized surface
    • Rompen E, DaSilva D, Lundgren A, Gottlow J, Sennerby L. Stability measurements of a double-threaded titanium implant design with turned or oxidized surface. Appl Osseointegration Res 2000;1:18-20.
    • (2000) Appl Osseointegration Res , vol.1 , pp. 18-20
    • Rompen, E.1    Dasilva, D.2    Lundgren, A.3    Gottlow, J.4    Sennerby, L.5
  • 10
    • 0029268053 scopus 로고
    • A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
    • Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies.Clin Oral Implants Res 1995;6:24-30.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 24-30
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3    Krol, J.J.4
  • 11
    • 20744448961 scopus 로고    scopus 로고
    • One-year results of a prospective multicenter study on Brȧnemark System implants with a TiUnite surface
    • Friberg B, Dahlin C, Widmark G, Ostman PO, Billstrom C. One-year results of a prospective multicenter study on Brȧnemark System implants with a TiUnite surface. Clin Implant Dent Relat Res 2005;7(suppl 1):670-675.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1 , pp. 670-675
    • Friberg, B.1    Dahlin, C.2    Widmark, G.3    Ostman, P.O.4    Billstrom, C.5
  • 12
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants. A human cadaver study
    • O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants. A human cadaver study.Clin Implant Dent Relat Res 2000;2: 85-92.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 13
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointe- grated titanium implants
    • O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointe- grated titanium implants. Clin Oral Implant Res 2004, 15: 474-480.
    • (2004) Clin Oral Implant Res , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 14
    • 0037491371 scopus 로고    scopus 로고
    • Primary stability and osseointegration: Preliminary clinical results with a tapered diminishing-thread implant
    • Abbou M. Primary stability and osseointegration: Preliminary clinical results with a tapered diminishing-thread implant. Pract Proced Aesthet Dent 2003;15:161-168.
    • (2003) Pract Proced Aesthet Dent , vol.15 , pp. 161-168
    • Abbou, M.1
  • 15
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brȧnemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study
    • Glauser R, Lundgren AK, Gottlow J, et al. Immediate occlusal loading of Brȧnemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.Clin Implant Dent Relat Res 2003;5(suppl 1):47-56.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 47-56
    • Glauser, R.1    Lundgren, A.K.2    Gottlow, J.3
  • 16
    • 32644446492 scopus 로고    scopus 로고
    • Resonance frequency analysis measurements of implants at replacement surgery
    • Östman P-O, Hellman M, Wendelhag I, Sennerby L. Resonance frequency analysis measurements of implants at replacement surgery. Int J Prosthodont 2006;19:77-83.
    • (2006) Int J Prosthodont , vol.19 , pp. 77-83
    • Östman, P.-O.1    Hellman, M.2    Wendelhag, I.3    Sennerby, L.4
  • 17
    • 0141829269 scopus 로고    scopus 로고
    • Bjisander implant brȧnemark standard the and iv) mk (prototype implant" bone "soft a of outcome the comparing study three-center prospective e.one-year
    • Friberg BJisander S, WidmarkG, et al. One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brȧnemark implant. Clin Implant Dent Relat Res 2003:71-77.
    • (2003) Clin Implant Dent Relat Res , pp. 71-77
    • Widmarkg, S.F.1
  • 18
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • In: Brȧnemark P-l, Zarb G, Albrektsson T (eds), Chicago: Quintessence
    • Lekholm U, Zarb G. Patient selection and preparation. In: Brȧnemark P-l, Zarb G, Albrektsson T (eds). Tissue-Integrated Prostheses. Chicago: Quintessence, 1985:199-211.
    • (1985) Tissue-Integrated Prostheses , pp. 199-211
    • Lekholm, U.1    Zarb, G.2
  • 19
    • 0034268232 scopus 로고    scopus 로고
    • Bahat 0. Brȧnemark system implants in the posterior maxilla. Clinical study of 660 implants followed for 5 to 12 years
    • Bahat 0. Brȧnemark system implants in the posterior maxilla. Clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants 2000;15:646-653.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 646-653
  • 20
    • 0348069566 scopus 로고
    • Presurgical treatment planning and surgical guidelines for dental implants
    • In: Wilson TG, Kornman KS, Newman MG (eds), Chicago: Quintessence
    • Bahat O, Handelsman M. Presurgical treatment planning and surgical guidelines for dental implants. In: Wilson TG, Kornman KS, Newman MG (eds). Advances in Periodontics. Chicago: Quintessence, 1992:323-340.
    • (1992) Advances in Periodontics , pp. 323-340
    • Bahat, O.1    Handelsman, M.2
  • 21
    • 0032150708 scopus 로고    scopus 로고
    • Surgical determinants of clinical success of osseointegrated oral implants. A review of literature
    • Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants. A review of literature. Int J Prosthodont 1998; 11:414-416.
    • (1998) Int J Prosthodont , vol.11 , pp. 414-416
    • Sennerby, L.1    Roos, J.2
  • 23
    • 0027734006 scopus 로고
    • Reconstruction of the hard and soft tissues for optimal placement of osseointegrated implants
    • Bahat O, Fontanesi RV, Preston J. Reconstruction of the hard and soft tissues for optimal placement of osseointegrated implants. Int J Periodontics Restorative Dent 1993;13:271-275.
    • (1993) Int J Periodontics Restorative Dent , vol.13 , pp. 271-275
    • Bahat, O.1    Fontanesi, R.V.2    Preston, J.3
  • 24
    • 0035375937 scopus 로고    scopus 로고
    • Efficacy of implant placement after bone grafting for three-dimensional reconstruction of the posterior jaw
    • Bahat O, Fontanesi RV. Efficacy of implant placement after bone grafting for three-dimensional reconstruction of the posterior jaw. Int J Periodontics Restorative Dent 2001;21:220-231.
    • (2001) Int J Periodontics Restorative Dent , vol.21 , pp. 220-231
    • Bahat, O.1    Fontanesi, R.V.2
  • 25
    • 0022726532 scopus 로고
    • Eriksson RA.The longterm efficacy of currently used dental implants. A review and proposed criteria of success
    • Albrektsson T, Zarb GA, Worthington P, Eriksson RA.The longterm efficacy of currently used dental implants. A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.A.2    Worthington, P.3
  • 26
    • 0026084439 scopus 로고
    • Berman CL.The excessive loss of Brȧnemark fixtures in type IV bone: A 5-year analysis
    • Jaffin RA, Berman CL.The excessive loss of Brȧnemark fixtures in type IV bone: A 5-year analysis. J Periodontol 1991;62:2-4.
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.A.1
  • 27
    • 0033137313 scopus 로고    scopus 로고
    • Wannfors K.lsaksson S, Adielsson B.Oral implants in combination with bone grafts. A 3-year retrospective multi- center study using the Brȧnemark implant system
    • Lekholm U, Wannfors K.lsaksson S, Adielsson B.Oral implants in combination with bone grafts. A 3-year retrospective multi- center study using the Brȧnemark implant system. Int J Oral Maxillofac Surg 1999;28:181-187.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 181-187
    • Lekholm, U.1
  • 28
    • 27844539319 scopus 로고    scopus 로고
    • Onlay augmentation versus sinus lift procedure in the treatment of the severely resorbed maxilla: A 5-year comparative longitudinal study
    • Wiltfang J, Schultze-Mosgau S, Nkenke EJhorwarth M, Neukam FW.Schlegel KA. Onlay augmentation versus sinus lift procedure in the treatment of the severely resorbed maxilla: A 5-year comparative longitudinal study. Int J Oral Maxillofac Surg 2005;34:885-889.
    • (2005) Int J Oral Maxillofac Surg , vol.34 , pp. 885-889
    • Wiltfang, J.1    Schultze-Mosgau, S.2    Nkenke Ejhorwarth, M.3    Neukam, F.4    Schlegel, K.A.5
  • 29
    • 0042012775 scopus 로고    scopus 로고
    • Immediate loading of Brȧnemark System TiUnite and machined-surface implants in the posterior mandible: A randomized open-ended clinical trial
    • Rocci A, Martignoni M, Gottlow J. Immediate loading of Brȧnemark System TiUnite and machined-surface implants in the posterior mandible: A randomized open-ended clinical trial. Clin Implant Dent Relat Res 2003;5(suppl 1):57-63.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.SUPPL. 1 , pp. 57-63
    • Rocci, A.1    Martignoni, M.2    Gottlow, J.3
  • 30
    • 0035748966 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brȧnemark implants applied in various jawbone regions: A prospective 1-year clinical study
    • Glauser R.'Ree A, Lundgren A, Gottlow J, Hammerle CH, Scharer P. Immediate occlusal loading of Brȧnemark implants applied in various jawbone regions: A prospective 1-year clinical study.Clin Implant Dent Relat Res 2001;3:204-213.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 204-213
    • Glauser R.'Ree, A.1    Lundgren, A.2    Gottlow, J.3    Ch, H.4    Scharer, P.5
  • 31
    • 0035755990 scopus 로고    scopus 로고
    • Is surgical skill more important for clinical success than changes in implant hardware?
    • Albrektsson T. Is surgical skill more important for clinical success than changes in implant hardware? Clin Implant Dent Relat Res 2001;3:174-175.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 174-175
    • Albrektsson, T.1
  • 32
    • 20744446270 scopus 로고    scopus 로고
    • Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study
    • Renouard F, Nisand D. Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study.Clin Implant Dent Relat Res 2005;7(suppl 1):S104-S110.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Renouard, F.1    Nisand, D.2
  • 33
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    • O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004;15: 474-480.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 34
    • 20744437092 scopus 로고    scopus 로고
    • Lundgren S.Oxidized titanium implants in reconstructive jaw surgery
    • Brechter M, Nilson H, Lundgren S.Oxidized titanium implants in reconstructive jaw surgery. Clin Implant Dent Relat Res 2005;7(suppl 1):S83-S87.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Brechter, M.1    Nilson, H.2
  • 35
    • 20744446862 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brȧnemark System TiUnite implants placed predominantly in soft bone: 4-year results of a prospective clinical study
    • Glauser R, Ruhstaller P, Windisch S, et al. Immediate occlusal loading of Brȧnemark System TiUnite implants placed predominantly in soft bone: 4-year results of a prospective clinical study.Clin Implant Dent Relat Res 2005;7(suppl 1): S52-S59.
    • (2005) Clin Implant Dent Relat Res , vol.7 , Issue.SUPPL. 1
    • Glauser, R.1    Ruhstaller, P.2    Windisch, S.3
  • 36
    • 0034573443 scopus 로고    scopus 로고
    • Retrospective multicenter study of an anodized, tapered, diminishing thread implant: Success rate at exposure
    • Callan DP, Hahn J, Hebel K, et al. Retrospective multicenter study of an anodized, tapered, diminishing thread implant: Success rate at exposure. Implant Dent 2000;9:329-336.
    • (2000) Implant Dent , vol.9 , pp. 329-336
    • Callan, D.P.1    Hahn, J.2    Hebel, K.3
  • 37
    • 0037608634 scopus 로고    scopus 로고
    • Immediate placement and provisionalization of maxillary anterior single implants: 1-year prospective study
    • Kan JY, Rungcharassaeng K, Lozada J. Immediate placement and provisionalization of maxillary anterior single implants: 1-year prospective study. Int J Oral Maxillofac Implants 2003; 18:31-39.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 31-39
    • Kan, J.Y.1    Rungcharassaeng, K.2    Lozada, J.3
  • 38
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting direct bone-to-implant anchorage in man
    • Albrektsson T, Brȧnemark P-l, Hansson H-A, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting direct bone-to-implant anchorage in man. Acta Orthop Scand 1981;52:155-170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Branemark, P.-L.2    Hansson, H.-A.3    Lindstrom, J.4
  • 39
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brȧnemark implant in partially edentulous jaws. A 10-year prospecitve multicenter study
    • Lekholm U.Gunne J, Henry P, et al. Survival of the Brȧnemark implant in partially edentulous jaws. A 10-year prospecitve multicenter study. Int J Oral Maxillofac Implants 1999;14: 639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 40
    • 0027735092 scopus 로고
    • The successful application of osseointegrated implants to the posterior jaw. A long-term retrospective study
    • Nevins M, Langer B.The successful application of osseointegrated implants to the posterior jaw. A long-term retrospective study. Int J Oral Maxillofac Implants 1993, 8:428-432.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 428-432
    • Nevins, M.1    Langer, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.