메뉴 건너뛰기




Volumn 5, Issue 2, 2003, Pages 71-77

One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant

Author keywords

Implant stability; Oral implants; Osseointegration; Resonance frequency analysis

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FOLLOW UP; HUMAN; IMPLANT; JAW; MALE; MANDIBLE; MAXILLA; OSTEOLYSIS; PERIODONTAL DISEASE; PROSPECTIVE STUDY; SURGICAL TECHNIQUE; TORQUE; TREATMENT OUTCOME;

EID: 0141829269     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2003.tb00186.x     Document Type: Article
Times cited : (75)

References (19)
  • 1
    • 0012364874 scopus 로고
    • The Brånemark implant technique: A standardised procedure under continuous development
    • Laney WR, Tolman DE, eds. Mayo Medical Center, Rochester, Minnesota. Chicago: Quintessence
    • Lekholm U. The Brånemark implant technique: a standardised procedure under continuous development. In: Laney WR, Tolman DE, eds. Tissue integration in oral, orthopedic, and maxillofacial reconstruction. Mayo Medical Center, Rochester, Minnesota. Chicago: Quintessence, 1990:194-199.
    • (1990) Tissue Integration in Oral, Orthopedic, and Maxillofacial Reconstruction , pp. 194-199
    • Lekholm, U.1
  • 2
    • 0026823202 scopus 로고
    • A new self-tapping Brånemark implant: Clinical and radiographic evaluation
    • Friberg B, Gröndahl K, Lekholm U. A new self-tapping Brånemark implant: clinical and radiographic evaluation. Int J Oral Maxillofac Implants 1992; 7:80-85.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 80-85
    • Friberg, B.1    Gröndahl, K.2    Lekholm, U.3
  • 3
    • 0029200739 scopus 로고
    • Mk II - A modified self-tapping Brånemark implant: 3-Year results of a controlled prospective pilot study
    • Olsson M, Friberg B, Nilsson H, Kultje C. Mk II - a modified self-tapping Brånemark implant: 3-year results of a controlled prospective pilot study. Int J Oral Maxillofac Implants 1995; 10:15-21.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 15-21
    • Olsson, M.1    Friberg, B.2    Nilsson, H.3    Kultje, C.4
  • 4
    • 0031197231 scopus 로고    scopus 로고
    • Mk II: The self-tapping Brånemark implant: 5-Year results of a prospective 3-center study
    • Friberg B, Nilsson H, Olsson M, Palmquist C. Mk II: the self-tapping Brånemark implant: 5-year results of a prospective 3-center study. Clin Oral Implants Res 1997; 8:279-285.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 279-285
    • Friberg, B.1    Nilsson, H.2    Olsson, M.3    Palmquist, C.4
  • 5
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: A human cadaver study
    • O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res 2000; 2:85-92.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 6
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Brånemark P-I, Zarb GA, Albrektsson T, eds. Chicago: Quintessence Publishing Co
    • Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark P-I, Zarb GA, Albrektsson T, eds. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago: Quintessence Publishing Co, 1985:199-209.
    • (1985) Tissue-integrated Prostheses: Osseointegration in Clinical Dentistry , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 7
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 8
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996; 7:261-267.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 9
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in-vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in-vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997; 8:226-233.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 11
    • 0033122309 scopus 로고    scopus 로고
    • Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw
    • Jemt T, Bäck T, Pettersson A. Precision of CNC-milled titanium frameworks for implant treatment in the edentulous jaw. Int J Prosthodont 1999; 12:209-215.
    • (1999) Int J Prosthodont , vol.12 , pp. 209-215
    • Jemt, T.1    Bäck, T.2    Pettersson, A.3
  • 12
  • 15
    • 0032150708 scopus 로고    scopus 로고
    • Resonance frequency analysis: Measuring implant stability and osseointegration
    • Sennerby L, Meredith N. Resonance frequency analysis: measuring implant stability and osseointegration. Compendium 1998; 11:408-420.
    • (1998) Compendium , vol.11 , pp. 408-420
    • Sennerby, L.1    Meredith, N.2
  • 16
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 17
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000; 11:12-25.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 19
    • 84995811049 scopus 로고
    • A new self-tapping Brånemark implant: Clinical and radiographical evaluation
    • Friberg B, Gröndahl K, Lekholm U. A new self-tapping Brånemark implant: clinical and radiographical evaluation. Int J Oral Maxillofac Implants 1992; 7:80-85.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 80-85
    • Friberg, B.1    Gröndahl, K.2    Lekholm, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.