메뉴 건너뛰기




Volumn 7, Issue SUPPL. 1, 2005, Pages s70-s75

One-year results of a prospective multicenter study on Brånemark System® implants with a TiUnite™ surface

Author keywords

Osseointegration; Prospective multicenter study; Rough surface

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CONTROLLED STUDY; EVALUATION; FINLAND; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MAXILLA; NORWAY; PATIENT COMPLIANCE; SECOND LOOK SURGERY; SURFACE PROPERTY; SURGICAL TECHNIQUE; SWEDEN; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH RADIOGRAPHY; TREATMENT FAILURE; TREATMENT OUTCOME;

EID: 20744448961     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2005.tb00077.x     Document Type: Article
Times cited : (46)

References (25)
  • 1
    • 0030184468 scopus 로고    scopus 로고
    • Osseointegrated implants for single-tooth replacement: A prospective 5-year multicenter study
    • Henry P, Laney WR, Jemt T, et al. Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1996; 11:450-455.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 450-455
    • Henry, P.1    Laney, W.R.2    Jemt, T.3
  • 2
    • 0030144715 scopus 로고    scopus 로고
    • A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants
    • Jemt T, Chai J, Harnett J, et al. A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants 1996; 11:291-298.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 291-298
    • Jemt, T.1    Chai, J.2    Harnett, J.3
  • 3
    • 0031197231 scopus 로고    scopus 로고
    • Mk II: The self-tapping Brånemark implant: 5-Year results of a prospective 3-center study
    • Friberg B, Nilsson H, Olsson M, Palmquist C. Mk II: the self-tapping Brånemark implant: 5-year results of a prospective 3-center study. Clin Oral Implants Res 1997; 8:279-285.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 279-285
    • Friberg, B.1    Nilsson, H.2    Olsson, M.3    Palmquist, C.4
  • 4
    • 85006809401 scopus 로고
    • Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study
    • Lekholm U, van Steenberghe D, Herrmann I, et al. Osseointegrated implants in the treatment of partially edentulous jaws: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1994; 9:627-635.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 627-635
    • Lekholm, U.1    Van Steenberghe, D.2    Herrmann, I.3
  • 5
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brånemark implant in the partially edentulous jaw. A 10 year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in the partially edentulous jaw. A 10 year prospective multicenter study. Int J Oral Maxillofac Implants 1999; 14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 6
    • 0002533641 scopus 로고    scopus 로고
    • Removal torque comparison of TiUnite and turned implants in the greyhound dog mandible
    • Henry P, Tan A, Brent A, Hall J, Johansson C. Removal torque comparison of TiUnite and turned implants in the greyhound dog mandible. Appl Osseointegration Res 2000; 1:15-17.
    • (2000) Appl Osseointegration Res , vol.1 , pp. 15-17
    • Henry, P.1    Tan, A.2    Brent, A.3    Hall, J.4    Johansson, C.5
  • 8
    • 0041960114 scopus 로고    scopus 로고
    • Stability measurements of a double-threaded titanium implant design with turned or oxidized surface. An experimental resonance frequency analysis study in the dog mandible
    • Rompen E, DaSilva D, Lundgren AK, Gottlow J, Sennerby L. Stability measurements of a double-threaded titanium implant design with turned or oxidized surface. An experimental resonance frequency analysis study in the dog mandible. Appl Osseointegration Res 2000; 1:18-20.
    • (2000) Appl Osseointegration Res , vol.1 , pp. 18-20
    • Rompen, E.1    DaSilva, D.2    Lundgren, A.K.3    Gottlow, J.4    Sennerby, L.5
  • 9
    • 0042961805 scopus 로고    scopus 로고
    • Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis
    • Glauser R, Portmann M, Ruhstaller P, Lundgren AK, Hämmerle C, Gottlow J. Stability measurements of immediately loaded machined and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis. Appl Osseointegration Res 2001; 2:27-29.
    • (2001) Appl Osseointegration Res , vol.2 , pp. 27-29
    • Glauser, R.1    Portmann, M.2    Ruhstaller, P.3    Lundgren, A.K.4    Hämmerle, C.5    Gottlow, J.6
  • 10
    • 0035748966 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark implants applied in various jawbone regions: A prospective, 1-year clinical study
    • Glauser R, Ree A, Lundgren A, Gottlow J, Hammerle CH, Scharer P. Immediate occlusal loading of Brånemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res 2001; 3:204-213.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 204-213
    • Glauser, R.1    Ree, A.2    Lundgren, A.3    Gottlow, J.4    Hammerle, C.H.5    Scharer, P.6
  • 11
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-Year results of a prospective clinical study
    • Glauser R, Lundgren AK, Gottlow J, et al. Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res 2003; 5(Suppl 1):47-56.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.1 SUPPL. , pp. 47-56
    • Glauser, R.1    Lundgren, A.K.2    Gottlow, J.3
  • 12
    • 20744452281 scopus 로고    scopus 로고
    • The influence of anodic oxidation on implant integration and stability in bone defects. An RFA study in the dog mandible
    • Salata L, Rasmusson L, Novaes A Jr, Papalexiou V, Sennerby L. The influence of anodic oxidation on implant integration and stability in bone defects. An RFA study in the dog mandible. Appl Osseointegration Res 2002; 3:32-34.
    • (2002) Appl Osseointegration Res , vol.3 , pp. 32-34
    • Salata, L.1    Rasmusson, L.2    Novaes Jr., A.3    Papalexiou, V.4    Sennerby, L.5
  • 13
    • 1342313093 scopus 로고    scopus 로고
    • Preliminary results of a prospective multicenter clinical study on TiUnite implants
    • Friberg B, Billström C. Preliminary results of a prospective multicenter clinical study on TiUnite implants. Appl Osseointegration Res 2002; 3:29-31.
    • (2002) Appl Osseointegration Res , vol.3 , pp. 29-31
    • Friberg, B.1    Billström, C.2
  • 14
    • 0002172340 scopus 로고
    • Patient selection and preparation
    • Brånemark P-I, Zarb GA, Albrektsson T, eds. Chicago: Quintessence Publishing Co
    • Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark P-I, Zarb GA, Albrektsson T, eds. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago: Quintessence Publishing Co, 1985:199-209.
    • (1985) Tissue-integrated Prostheses: Osseointegration in Clinical Dentistry , pp. 199-209
    • Lekholm, U.1    Zarb, G.A.2
  • 15
    • 1342345177 scopus 로고    scopus 로고
    • Mk III: A third generation of the self-tapping Brånemark System® implant, including the new Stargrip™ internal grip design. A 1-year prospective four-center study
    • Widmark G, Friberg B, Johansson B, Sindet-Pedersen S, Taylor Å. Mk III: a third generation of the self-tapping Brånemark System® implant, including the new Stargrip™ internal grip design. A 1-year prospective four-center study. Clin Implant Dent Relat Res 2003; 5:273-279.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 273-279
    • Widmark, G.1    Friberg, B.2    Johansson, B.3    Sindet-Pedersen, S.4    Taylor, Å.5
  • 16
    • 0026167719 scopus 로고
    • Early failures in 4641 consecutively placed Brånemark dental implants: A study from stage 1 surgery to the connection of completed prostheses
    • Friberg B, Jemt T, Lekholm U. Early failures in 4641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed prostheses. Int J Oral Maxillofac Implants 1991; 6:142-146.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 142-146
    • Friberg, B.1    Jemt, T.2    Lekholm, U.3
  • 17
    • 0029200739 scopus 로고
    • Mk II - A modified self-tapping Brånemark implant: 3-Year results of a controlled prospective pilot study
    • Olsson M, Friberg B, Nilsson H, Kultje C. Mk II - a modified self-tapping Brånemark implant: 3-year results of a controlled prospective pilot study. Int J Oral Maxillofac Implants 1995; 10:15-21.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 15-21
    • Olsson, M.1    Friberg, B.2    Nilsson, H.3    Kultje, C.4
  • 18
    • 0031989768 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated implants. (1). Success criteria and epidemiology
    • Esposito M, Hirsch J-M, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated implants. (1). Success criteria and epidemiology. Eur J Oral Sci 1998; 106:527-551.
    • (1998) Eur J Oral Sci , vol.106 , pp. 527-551
    • Esposito, M.1    Hirsch, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 20
    • 0034268232 scopus 로고    scopus 로고
    • Brånemark System implants in the posterior maxilla: Clinical study of 660 implants followed for 5 to 12 years
    • Bahat O. Brånemark System implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants 2000; 15:646-653.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 646-653
    • Bahat, O.1
  • 22
    • 0036719340 scopus 로고    scopus 로고
    • Clinical outcome of Brånemark System™ implants of various diameters. A retrospective study
    • Friberg B, Ekestubbe A, Sennerby L. Clinical outcome of Brånemark System™ implants of various diameters. A retrospective study. Int J Oral Maxillofac Impl 2002; 17:671-677.
    • (2002) Int J Oral Maxillofac Impl , vol.17 , pp. 671-677
    • Friberg, B.1    Ekestubbe, A.2    Sennerby, L.3
  • 23
    • 0026084439 scopus 로고
    • The excessive loss of Brånemark fixtures in type IV bone: A 5-year analysis
    • Jaffin R, Berman C. The excessive loss of Brånemark fixtures in type IV bone: a 5-year analysis. J Periodontol 1991; 62:2-4.
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.1    Berman, C.2
  • 24
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.