메뉴 건너뛰기




Volumn 25, Issue 3, 2009, Pages 141-147

Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams

Author keywords

Electron beam radiotherapy; In vivo dosimetry; MOSFET

Indexed keywords

ARTICLE; DEPENDENT PERSONALITY DISORDER; DOSE RESPONSE; DOSIMETER; DOSIMETRY; ELECTRON BEAM; ENERGY; IONIZATION CHAMBER; METAL OXIDE SEMICONDUCTOR FIELD EFFECT TRANSISTOR DETECTOR; PHANTOM; RADIATION DETECTOR; RADIATION FIELD; REPRODUCIBILITY; TEMPERATURE DEPENDENCE;

EID: 68849111322     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejmp.2008.11.003     Document Type: Article
Times cited : (22)

References (29)
  • 3
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: report of AAPM radiation therapy committee
    • Task group 40
    • Kutcher G.J., Coia L., Gillin M., Hanson F.W., Leibel S., Morton R.J., et al. Comprehensive QA for radiation oncology: report of AAPM radiation therapy committee. Task group 40. Med Phys 21 (1994) 581-618
    • (1994) Med Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3    Hanson, F.W.4    Leibel, S.5    Morton, R.J.6
  • 4
    • 85044686530 scopus 로고
    • Protection of the patient in radiation therapy. ICRP publication 44. International Commission on Radiological Protection (ICRP)
    • Protection of the patient in radiation therapy. ICRP publication 44. International Commission on Radiological Protection (ICRP). Ann ICRP, 15:2; 1985.
    • (1985) Ann ICRP , vol.15 , pp. 2
  • 6
    • 0029856223 scopus 로고    scopus 로고
    • Quality assurance in radiotherapy: the importance of medical physics staffing levels. Recommendations from an ESTRO/EFOMP joint task group
    • Belleti S., Dutreix G., Garavaglia G., Gfirtner H., Haywood J., Jessen K.A., et al. Quality assurance in radiotherapy: the importance of medical physics staffing levels. Recommendations from an ESTRO/EFOMP joint task group. Radiother Oncol 41 (1996) 89-94
    • (1996) Radiother Oncol , vol.41 , pp. 89-94
    • Belleti, S.1    Dutreix, G.2    Garavaglia, G.3    Gfirtner, H.4    Haywood, J.5    Jessen, K.A.6
  • 9
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide semiconductor field effect transistor detector as radiation detector
    • Soubra M., Cygler J., and Mackay G. Evaluation of a dual bias dual metal oxide semiconductor field effect transistor detector as radiation detector. Med Phys 21 (1994) 567-572
    • (1994) Med Phys , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    Mackay, G.3
  • 11
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • Chuang C.F., Verhey L.J., and Xia P. Investigation of the use of MOSFET for clinical IMRT dosimetric verification. Med Phys 29 (2002) 1109-1115
    • (2002) Med Phys , vol.29 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 12
    • 0031956451 scopus 로고    scopus 로고
    • Use of new types of radiochromic film, a new parallel plate chamber, MOSFETs and TLD 800 microcubes in the dosimetry of small beams
    • Franscescon P., Cora S., Cavedon C., Scalchi P., Sonia R., and Colombo F. Use of new types of radiochromic film, a new parallel plate chamber, MOSFETs and TLD 800 microcubes in the dosimetry of small beams. Med Phys 25 (1998) 503-511
    • (1998) Med Phys , vol.25 , pp. 503-511
    • Franscescon, P.1    Cora, S.2    Cavedon, C.3    Scalchi, P.4    Sonia, R.5    Colombo, F.6
  • 14
    • 4644311758 scopus 로고    scopus 로고
    • Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
    • Jornet N., Carrasco P., Jurado D., Ruiz A., Eudaldo T., and Ribas M. Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams. Med Phys 31 (2004) 2534-2542
    • (2004) Med Phys , vol.31 , pp. 2534-2542
    • Jornet, N.1    Carrasco, P.2    Jurado, D.3    Ruiz, A.4    Eudaldo, T.5    Ribas, M.6
  • 15
    • 16344393413 scopus 로고    scopus 로고
    • In vivo measurements with MOSFET detectors in oropharynx and nasopharynx intensity modulated radiotherapy
    • Marcie S., Charpiot E., Bensadour R.J., Ciasis G., Herault J., Costa A., et al. In vivo measurements with MOSFET detectors in oropharynx and nasopharynx intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys 61 (2005) 1603-1606
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1603-1606
    • Marcie, S.1    Charpiot, E.2    Bensadour, R.J.3    Ciasis, G.4    Herault, J.5    Costa, A.6
  • 16
    • 13644255923 scopus 로고    scopus 로고
    • Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV
    • Ehringfeld C., Schmid S., Poljanc K., Kirisits C., Aiginger H., and Georg D. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV. Phys Med Biol 50 (2005) 289-303
    • (2005) Phys Med Biol , vol.50 , pp. 289-303
    • Ehringfeld, C.1    Schmid, S.2    Poljanc, K.3    Kirisits, C.4    Aiginger, H.5    Georg, D.6
  • 17
    • 0036888598 scopus 로고    scopus 로고
    • Characterization of high sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF: Mg, Cu, P thermoluminescence dosimeters for use in diagnostic radiology
    • Dong S.L., Chu T.C., Lan G.Y., Wu T.H., Lin Y.C., and Lee J.S. Characterization of high sensitivity metal oxide semiconductor field effect transistor dosimeters system and LiF: Mg, Cu, P thermoluminescence dosimeters for use in diagnostic radiology. Appl Radiat Isot 57 (2002) 883-891
    • (2002) Appl Radiat Isot , vol.57 , pp. 883-891
    • Dong, S.L.1    Chu, T.C.2    Lan, G.Y.3    Wu, T.H.4    Lin, Y.C.5    Lee, J.S.6
  • 18
    • 0031868395 scopus 로고    scopus 로고
    • The characterization of a commercial MOSFET dosimeter system for use in diagnostic X-ray
    • Bower M.W., and Hintenlang D.E. The characterization of a commercial MOSFET dosimeter system for use in diagnostic X-ray. Health Phys 75 (1998) 197-204
    • (1998) Health Phys , vol.75 , pp. 197-204
    • Bower, M.W.1    Hintenlang, D.E.2
  • 19
    • 25844482617 scopus 로고    scopus 로고
    • In vivo dosimetry with MOSFETs: dosimetric characterization and first clinical results in intraoperative radiotherapy
    • Consorti R., Petrucci A., Fortunate F., Soriani A., Marzi S., Iaccarino G., et al. In vivo dosimetry with MOSFETs: dosimetric characterization and first clinical results in intraoperative radiotherapy. Int J Radiat Oncol Biol Phys 63 (2005) 952-960
    • (2005) Int J Radiat Oncol Biol Phys , vol.63 , pp. 952-960
    • Consorti, R.1    Petrucci, A.2    Fortunate, F.3    Soriani, A.4    Marzi, S.5    Iaccarino, G.6
  • 21
    • 27644477356 scopus 로고    scopus 로고
    • Characterization of responses and comparison of calibration factor for commercial MOSFET detectors
    • Bharanidharan G., Manigandan D., Devan K., Subramani V., Gopishankar N., Ganesh T., et al. Characterization of responses and comparison of calibration factor for commercial MOSFET detectors. Med Dosim 30 (2005) 213-218
    • (2005) Med Dosim , vol.30 , pp. 213-218
    • Bharanidharan, G.1    Manigandan, D.2    Devan, K.3    Subramani, V.4    Gopishankar, N.5    Ganesh, T.6
  • 22
    • 4544233994 scopus 로고    scopus 로고
    • Performance characteristics of a micro MOSFET as an in vivo dosimeter in radiation therapy
    • Ramaseshan A., Kohli K.S., Zhang T.J., Lam T., Norlinger B., Hallil A., et al. Performance characteristics of a micro MOSFET as an in vivo dosimeter in radiation therapy. Phys Med Biol 49 (2004) 4031-4048
    • (2004) Phys Med Biol , vol.49 , pp. 4031-4048
    • Ramaseshan, A.1    Kohli, K.S.2    Zhang, T.J.3    Lam, T.4    Norlinger, B.5    Hallil, A.6
  • 24
  • 25
    • 33846892998 scopus 로고    scopus 로고
    • Beta dosimetry with micro MOSFETs for endovascular brachytherapy
    • Drud E., Todorovic M., Schonborn T., and Schmidt R. Beta dosimetry with micro MOSFETs for endovascular brachytherapy. Phys Med Biol 51 (2006) 5977-5986
    • (2006) Phys Med Biol , vol.51 , pp. 5977-5986
    • Drud, E.1    Todorovic, M.2    Schonborn, T.3    Schmidt, R.4
  • 26
    • 33846882152 scopus 로고    scopus 로고
    • Experimental evaluation of a MOSFET dosimeter for proton dose measurements
    • Kohno R., Nishio T., Miyagishi T., Hirano E., Hotta K., Kawashima M., et al. Experimental evaluation of a MOSFET dosimeter for proton dose measurements. Phys Med Biol 51 (2006) 6077-6086
    • (2006) Phys Med Biol , vol.51 , pp. 6077-6086
    • Kohno, R.1    Nishio, T.2    Miyagishi, T.3    Hirano, E.4    Hotta, K.5    Kawashima, M.6
  • 27
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • Essers M., and Mijnheer B.J. In vivo dosimetry during external photon beam radiotherapy. Int J Radiat Oncol Biol Phys 43 (1999) 245-249
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 245-249
    • Essers, M.1    Mijnheer, B.J.2
  • 28
    • 68849087494 scopus 로고    scopus 로고
    • Thomson and Nielsen Electronics Ltd Ottawa
    • Thomson and Nielsen Electronics Ltd (Ottawa). Technical note no: 4; 1996.
    • (1996) Technical note , Issue.4
  • 29
    • 0003982205 scopus 로고    scopus 로고
    • Stopping powers for electrons and positrons
    • no. 37; 1984
    • Stopping powers for electrons and positrons. ICRU report no. 37; 1984.
    • ICRU report


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.