메뉴 건너뛰기




Volumn 75, Issue 2, 1998, Pages 197-204

The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray

Author keywords

Diagnostic radiology; Dose, absorbed; Medical radiation; X rays

Indexed keywords

METAL OXIDE;

EID: 0031868395     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199808000-00013     Document Type: Article
Times cited : (54)

References (17)
  • 3
    • 0030169875 scopus 로고    scopus 로고
    • Fast and slow border traps in MOS devices
    • Fleetwood, D. M. Fast and slow border traps in MOS devices. IEEE Transactions on Nucl. Sci. 43:779-785; 1996.
    • (1996) IEEE Transactions on Nucl. Sci. , vol.43 , pp. 779-785
    • Fleetwood, D.M.1
  • 5
    • 0027239158 scopus 로고
    • Transistors with > 1 μm thick gate oxide for ionizing radiation dosimetry
    • Gessinn, F.; Sarrabayrouse, G. M.O.S. transistors with > 1 μm thick gate oxide for ionizing radiation dosimetry. Materials Res. Soc. Symp. Proc. 302:555-560; 1993.
    • (1993) Materials Res. Soc. Symp. Proc. , vol.302 , pp. 555-560
    • Gessinn, F.1    Sarrabayrouse, G.M.O.S.2
  • 6
    • 0025762578 scopus 로고
    • Automated data collection and analysis system for MOSFET radiation detectors
    • Gladstone, D. J.; Chin, L. M. Automated data collection and analysis system for MOSFET radiation detectors. Med. Phys. 18:542-547; 1991.
    • (1991) Med. Phys. , vol.18 , pp. 542-547
    • Gladstone, D.J.1    Chin, L.M.2
  • 7
    • 0028939777 scopus 로고
    • Real-time, in vivo measurement of radiation dose during radioimmunotherapy in mice using a miniature MOSFET dosimeter probe
    • Gladstone, D. J.; Chin, L. M. Real-time, in vivo measurement of radiation dose during radioimmunotherapy in mice using a miniature MOSFET dosimeter probe. Radiat. Res. 141:330-335; 1995.
    • (1995) Radiat. Res. , vol.141 , pp. 330-335
    • Gladstone, D.J.1    Chin, L.M.2
  • 10
    • 0020943374 scopus 로고
    • The mechanisms of small instabilities in irradiated MOS transistors
    • Holmes-Siedle, A.; Adams, L. The mechanisms of small instabilities in irradiated MOS transistors. IEEE Transactions on Nucl. Sci. NS-30:4135-4139; 1983.
    • (1983) IEEE Transactions on Nucl. Sci. , vol.NS-30 , pp. 4135-4139
    • Holmes-Siedle, A.1    Adams, L.2
  • 11
    • 0029251910 scopus 로고
    • A design solution to increasing the sensitivity of pMOS dosimeters: The stacked RADFET approach
    • Kelleher, A.; Lane, W.; Adams, L. A design solution to increasing the sensitivity of pMOS dosimeters: the stacked RADFET approach. IEEE Transactions on Nucl. Sci. 42:48-51; 1995.
    • (1995) IEEE Transactions on Nucl. Sci. , vol.42 , pp. 48-51
    • Kelleher, A.1    Lane, W.2    Adams, L.3
  • 14
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • Soubra, M.; Cygler, J.; Mackay, G. Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter. Med. Phys. 21:567-572; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    Mackay, G.3
  • 16
    • 0030165452 scopus 로고    scopus 로고
    • Assessment of a new p-MOSFET usable as a doserate insensitive gamma dose sensor
    • Vettese, F.; Donichak, C.; Bourgeault, P. Assessment of a new p-MOSFET usable as a doserate insensitive gamma dose sensor. IEEE Transactions on Nucl. Sci. 43:991-996; 1996.
    • (1996) IEEE Transactions on Nucl. Sci. , vol.43 , pp. 991-996
    • Vettese, F.1    Donichak, C.2    Bourgeault, P.3
  • 17
    • 0028185452 scopus 로고
    • Potential biological effects following high x-ray dose interventional procedures
    • Wagner, L. K.; Eifel, P. J.; Geise, R. A. Potential biological effects following high x-ray dose interventional procedures. J. Vascular and Interventional Radiol. 5:71-84; 1994.
    • (1994) J. Vascular and Interventional Radiol. , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.