Volumn 22, Issue 4, 2009, Pages 383-392

Artifacts found during quality assurance testing of computed radiography and digital radiography detectors

Author keywords

Computed radiography; Diagnostic image quality; Digital radiology; Image artifact; Quality assurance; Radiography

Indexed keywords

ARTIFACT IMAGES; COMPUTED RADIOGRAPHY; DIAGNOSTIC IMAGE QUALITY; DIGITAL RADIOGRAPHY; DIGITAL RADIOLOGY; FLAT FIELD CORRECTION; IMAGE ARTIFACT; IMAGE RETENTION; LOW-PASS; MECHANICAL MOVEMENTS; PERFORMANCE TESTING; QUALITY ASSURANCE TESTING; SPATIAL FREQUENCY; TEST OBJECT; UNSHARP MASKING; X-RAY IMAGING DETECTOR;

EID: 68049139345     PISSN: 08971889     EISSN: 1618727X     Source Type: Journal    
DOI: 10.1007/s10278-008-9109-0     Document Type: Article
Times cited : (11)

References (20)
  • 5
    • 0030023013 scopus 로고    scopus 로고
    • Artifacts in chest radiographs with a third generation computed radiography system
    • JP Volpe ML Storto KP Andriole G Gamsu 1996 Artifacts in chest radiographs with a third generation computed radiography system Am J Roentgenol 166 653 657
    • (1996) Am J Roentgenol , vol.166 , pp. 653-657
    • Volpe, J.P.1    Storto, M.L.2    Andriole, K.P.3    Gamsu, G.4
  • 6
    • 33748621469 scopus 로고    scopus 로고
    • Recognition and prevention of computed radiography image artifacts
    • K Hammerstrom J Aldrich L Alves A Ho 2006 Recognition and prevention of computed radiography image artifacts J Digit Imaging 19 226 239
    • (2006) J Digit Imaging , vol.19 , pp. 226-239
    • Hammerstrom, K.1    Aldrich, J.2    Alves, L.3    Ho, A.4
  • 7
    • 0742306424 scopus 로고    scopus 로고
    • Artifacts and misadventures in digital radiography
    • CE Willis SK Thompson SJ Shepard 2004 Artifacts and misadventures in digital radiography Appl Radiol 33 1 11 20
    • (2004) Appl Radiol , vol.33 , Issue.1 , pp. 11-20
    • Willis, C.E.1    Thompson, S.K.2    Shepard, S.J.3
  • 10
    • 0032402683 scopus 로고    scopus 로고
    • Flat-field correction technique for digital detectors
    • JA Seibert JM Boone KK Lindfors 1998 Flat-field correction technique for digital detectors Proc SPIE 3336 348 354
    • (1998) Proc SPIE , vol.3336 , pp. 348-354
    • Seibert, J.A.1    Boone, J.M.2    Lindfors, K.K.3
  • 12
    • 1642569121 scopus 로고    scopus 로고
    • Assessment of the effects of pixel loss on image quality in direct digital radiography
    • R Padgett CJ Kotre 2004 Assessment of the effects of pixel loss on image quality in direct digital radiography Phys Med Biol 49 977 986
    • (2004) Phys Med Biol , vol.49 , pp. 977-986
    • Padgett, R.1    Kotre, C.J.2
  • 13
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager
    • JH Siewerdsen DA Jaffray 1999 A ghost story: Spatio-temporal response characteristics of an indirect-detection flat-panel imager Med Phys 26 1624 1641
    • (1999) Med Phys , vol.26 , pp. 1624-1641
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 14
    • 3042692655 scopus 로고    scopus 로고
    • Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history
    • MZ Kabir M Yunus SO Kasap 2004 Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history Proc SPIE 5368 170 176
    • (2004) Proc SPIE , vol.5368 , pp. 170-176
    • Kabir, M.Z.1    Yunus, M.2    Kasap, S.O.3
  • 15
    • 0036033452 scopus 로고    scopus 로고
    • Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
    • W Zhao G DeCrescenzo JA Rowlands 2002 Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors Proc SPIE 4682 9 20
    • (2002) Proc SPIE , vol.4682 , pp. 9-20
    • Zhao, W.1    Decrescenzo, G.2    Rowlands, J.A.3
  • 17
    • 34547417197 scopus 로고    scopus 로고
    • Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors
    • A Mackenzie ID Honey 2007 Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors Med Phys 34 8 3345 3357
    • (2007) Med Phys , vol.34 , Issue.8 , pp. 3345-3357
    • MacKenzie, A.1    Honey, I.D.2
  • 18
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • E Samei MJ Flynn 2003 An experimental comparison of detector performance for direct and indirect digital radiography systems Med Phys 30 4 608 622
    • (2003) Med Phys , vol.30 , Issue.4 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 19
    • 0036703531 scopus 로고    scopus 로고
    • Aliasing effects in digital images of line pair phantoms
    • M Albert DJ Beideck PR Bakic ADA Maidment 2002 Aliasing effects in digital images of line pair phantoms Med Phys 29 8 1716 1718
    • (2002) Med Phys , vol.29 , Issue.8 , pp. 1716-1718
    • Albert, M.1    Beideck, D.J.2    Bakic, P.R.3    Maidment, A.D.A.4
  • 20
    • 0031942883 scopus 로고    scopus 로고
    • Physical imaging performance of a compact computed radiography acquisition device
    • SM Kengyelics JH Launders AR Cowen 1998 Physical imaging performance of a compact computed radiography acquisition device Med Phys 25 354 360
    • (1998) Med Phys , vol.25 , pp. 354-360
    • Kengyelics, S.M.1    Launders, J.H.2    Cowen, A.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.