메뉴 건너뛰기




Volumn 25, Issue 3, 1998, Pages 354-360

Physical imaging performance of a compact computed radiography acquisition device

Author keywords

Computed radiography; Detective quantum efficiency; Modulation transfer function; Noise equivalent quanta; Wiener spectrum

Indexed keywords

EFFICIENCY; IMAGE ENHANCEMENT; LUMINESCENCE; MODULATION; OPTICAL TRANSFER FUNCTION; QUANTUM NOISE; TRANSFER FUNCTIONS; X RAY RADIOGRAPHY;

EID: 0031942883     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598212     Document Type: Article
Times cited : (31)

References (12)
  • 2
    • 0029464580 scopus 로고
    • Quantitative analysis of imaging performance for computed radiography systems
    • E. Ogawa, S. Arakawa, M. Ishida, and H. Kato, "Quantitative analysis of imaging performance for computed radiography systems," Proc. SPIE 2432, 421-431 (1995).
    • (1995) Proc. SPIE , vol.2432 , pp. 421-431
    • Ogawa, E.1    Arakawa, S.2    Ishida, M.3    Kato, H.4
  • 3
    • 33847482816 scopus 로고
    • Fuji Computed Radiography Technical Review No. 2, New Technological Developments in the FCR9000
    • Fuji Photo Film Co., Ltd. Japan
    • T. Matsuda, S. Arakawa, K. Kohda, S. Tori, and N. Nakajima, "Fuji Computed Radiography Technical Review No. 2, New Technological Developments in the FCR9000," Fuji film Imaging and Information, Fuji Photo Film Co., Ltd. Japan (1993).
    • (1993) Fuji Film Imaging and Information
    • Matsuda, T.1    Arakawa, S.2    Kohda, K.3    Tori, S.4    Nakajima, N.5
  • 4
    • 0021848431 scopus 로고
    • Unified SNR analysis of medical imaging systems
    • R. F. Wagner and D. G. Brown, "Unified SNR analysis of medical imaging systems," Phys. Med. Biol. 30, 489-518 (1985).
    • (1985) Phys. Med. Biol. , vol.30 , pp. 489-518
    • Wagner, R.F.1    Brown, D.G.2
  • 6
    • 0025325133 scopus 로고
    • Quantitative radiographic imaging using a photostimulable phosphor system
    • C. E. Floyd, Jr., H. G. Chotas, J. T. Dobbins III, and C. E. Ravin, "Quantitative radiographic imaging using a photostimulable phosphor system," Med. Phys. 17, 454-459 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 454-459
    • Floyd Jr., C.E.1    Chotas, H.G.2    Dobbins III, J.T.3    Ravin, C.E.4
  • 10
    • 0027480974 scopus 로고
    • Physical aspects of photostimulable phosphor computed radiography
    • A. R. Cowen, A. Workman, and J. S. Price, "Physical aspects of photostimulable phosphor computed radiography," Br. J. Radiol. 66, 332-345 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 332-345
    • Cowen, A.R.1    Workman, A.2    Price, J.S.3
  • 11
    • 0023611229 scopus 로고
    • Imaging performance of a digital storage phosphor system
    • W. Hillen, U. Schiebel, and T. Zaengel, "Imaging performance of a digital storage phosphor system," Med. Phys. 14, 744-751 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 744-751
    • Hillen, W.1    Schiebel, U.2    Zaengel, T.3
  • 12
    • 0027738819 scopus 로고
    • Signal, Noise and SNR transfer properties of computed radiography
    • A. Workman and A. R. Cowen, "Signal, Noise and SNR transfer properties of computed radiography," Phys. Med. Biol. 38, 1789-1808 (1987).
    • (1987) Phys. Med. Biol. , vol.38 , pp. 1789-1808
    • Workman, A.1    Cowen, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.