메뉴 건너뛰기




Volumn 29, Issue 8, 2002, Pages 1716-1718

Aliasing effects in digital images of line-pair phantoms

Author keywords

[No Author keywords available]

Indexed keywords

ALIASING EFFECTS; DIGITAL IMAGE; MEDICAL PHYSICISTS; PERIODIC PATTERN; SCREEN-FILM SYSTEM; SUPER RESOLUTION;

EID: 0036703531     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1493212     Document Type: Article
Times cited : (9)

References (7)
  • 3
    • 0021253653 scopus 로고
    • Investigation of basic imaging properties in digital radiography. I. Modulation transfer function
    • M. L. Giger and K. Doi. "Investigation of basic imaging properties in digital radiography. I. Modulation transfer function," Med. Phys. 11, 287-295 (1984)
    • (1984) Med. Phys , vol.11 , pp. 287-295
    • Giger, M.L.1    Doi, K.2
  • 4
    • 0032403949 scopus 로고    scopus 로고
    • Thin film transistor array technology for high performance, direct conversion x-ray sensors
    • SPIE 3336 (Bellingham, Washington)
    • W. den Boer et al., "Thin film transistor array technology for high performance, direct conversion x-ray sensors," SPIE Conference on Physics of Medical Imaging, SPIE 3336 (Bellingham, Washington, 1998), pp. 520-528
    • (1998) SPIE Conference on Physics of Medical Imaging , pp. 520-528
    • Den Boer, W.1
  • 5
    • 0032402954 scopus 로고    scopus 로고
    • Improved imaging performance of a 14×17-inch Direct Radiolgraphy(TM) System using Se/TFT detector
    • SPIE 3336 (Bellingham, Washington)
    • D. L. Lee, L. K. Cheung, B. Rodricks, and G. F. Powell, "Improved imaging performance of a 14×17-inch Direct Radiolgraphy(TM) System using Se/TFT detector," SPIE Conference on Physics of Medical Imaging, SPIE 3336 (Bellingham, Washington, 1998), pp. 14-23
    • (1998) SPIE Conference on Physics of Medical Imaging , pp. 14-23
    • Lee, D.L.1    Cheung, L.K.2    Rodricks, B.3    Powell, G.F.4
  • 6
    • 0033983981 scopus 로고    scopus 로고
    • Signal-to-noise ratio and spatial resolution in x-ray electronic imagers: Is the MTF a relevant parameter?
    • J.-P. Moy, "Signal-to-noise ratio and spatial resolution in x-ray electronic imagers: Is the MTF a relevant parameter?," Med. Phys. 27, 86-93 (2000)
    • (2000) Med. Phys , vol.27 , pp. 86-93
    • Moy, J.-P.1
  • 7
    • 0033750998 scopus 로고    scopus 로고
    • Linear response theory for detectors consisting of discrete arrays
    • M. Albert and A. D. A. Maidment, "Linear response theory for detectors consisting of discrete arrays," Med. Phys. 27. 2417-2434 (2000)
    • (2000) Med. Phys , vol.27 , pp. 2417-2434
    • Albert, M.1    Maidment, A.D.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.