Assessment of the effects of pixel loss on image quality in direct digital radiography

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE QUALITY; QUALITY ASSURANCE; QUANTUM EFFICIENCY; TRANSFER FUNCTIONS;

EID: 1642569121     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/49/6/008     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 0038033836 scopus 로고    scopus 로고
    • On site evaluation of three flat panel detectors for digital radiography
    • Borasi G, Nitrosi A, Ferrari P and Tassoni D 2003 On site evaluation of three flat panel detectors for digital radiography Med. Phys. 30 1719-31
    • (2003) Med. Phys. , vol.30 , pp. 1719-1731
    • Borasi, G.1    Nitrosi, A.2    Ferrari, P.3    Tassoni, D.4
  • 2
    • 0021164719 scopus 로고
    • Analysis of variations in contrast-detail experiments
    • Cohen G, McDaniel D L and Wagner L K 1984 Analysis of variations in contrast-detail experiments Med. Phys. 11 469-73
    • (1984) Med. Phys. , vol.11 , pp. 469-473
    • Cohen, G.1    McDaniel, D.L.2    Wagner, L.K.3
  • 3
    • 0004152630 scopus 로고    scopus 로고
    • Catalogue of diagnostic x-ray spectra and other data
    • (York: Institute of Physics and Engineering in Medicine)
    • Cranley K, Gilmore B J, Fogarty G W A and Desponds L 1997 Catalogue of diagnostic x-ray spectra and other data IPEM Report 78 (York: Institute of Physics and Engineering in Medicine)
    • (1997) IPEM Report 78
    • Cranley, K.1    Gilmore, B.J.2    Fogarty, G.W.A.3    Desponds, L.4
  • 4
    • 58749103831 scopus 로고    scopus 로고
    • Degradation of the detective quantum efficiency due to a non-unity detector fill factor
    • ed R L Van Metter and J Beutel Proc. SPIE 3032
    • Cunningham I A 1997 Degradation of the detective quantum efficiency due to a non-unity detector fill factor Medical Imaging 1997: Physics of Medical Imaging ed R L Van Metter and J Beutel Proc. SPIE 3032 22-31
    • (1997) Medical Imaging 1997: Physics of Medical Imaging , pp. 22-31
    • Cunningham, I.A.1
  • 6
    • 0032812524 scopus 로고    scopus 로고
    • Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    • Flynn M J and Samei E 1999 Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems Med. Phys. 26 1612-23
    • (1999) Med. Phys. , vol.26 , pp. 1612-1623
    • Flynn, M.J.1    Samei, E.2
  • 7
    • 1642561024 scopus 로고    scopus 로고
    • Hologic Dead pixel correction, private communication
    • Hologic 2003 Dead pixel correction, private communication
    • (2003)
  • 8
    • 0034993655 scopus 로고    scopus 로고
    • The practical application of signal detection theory to image quality assessment in x-ray image intensifier-TV fluoroscopy
    • Marshall N W 2001 The practical application of signal detection theory to image quality assessment in x-ray image intensifier-TV fluoroscopy Phys. Med. Biol. 46 1631-49
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1631-1649
    • Marshall, N.W.1
  • 9
    • 0028132062 scopus 로고
    • The contrast-detail behaviour of a photostimulable phosphor based computed radiography system
    • Marshall N W, Faulkner K, Busch H P and Lehmann K J 1994 The contrast-detail behaviour of a photostimulable phosphor based computed radiography system Phys. Med. Biol. 39 2289-303
    • (1994) Phys. Med. Biol. , vol.39 , pp. 2289-2303
    • Marshall, N.W.1    Faulkner, K.2    Busch, H.P.3    Lehmann, K.J.4
  • 11
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/caesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - A contrast-detail phantom study
    • Rong X J, Shaw C C, Liu X, Lemacks M R and Thompson S K 2001 Comparison of an amorphous silicon/caesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - a contrast-detail phantom study Med. Phys. 28 2328-35
    • (2001) Med. Phys. , vol.28 , pp. 2328-2335
    • Rong, X.J.1    Shaw, C.C.2    Liu, X.3    Lemacks, M.R.4    Thompson, S.K.5
  • 12
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using and edge test device
    • Samei E and Flynn M J 1998 A method for measuring the presampled MTF of digital radiographic systems using and edge test device Med. Phys. 25 102-13
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2
  • 13
    • 0036122063 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for computed radiography systems
    • Samei E and Flynn M J 2002 An experimental comparison of detector performance for computed radiography systems Med. Phys. 29 447-59
    • (2002) Med. Phys. , vol.29 , pp. 447-459
    • Samei, E.1    Flynn, M.J.2
  • 15
    • 0035996468 scopus 로고    scopus 로고
    • Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy
    • Srinivas Y and Wilson D L 2002 Image quality evaluation of flat panel and image intensifier digital magnification in x-ray fluoroscopy Med. Phys. 29 1611-21
    • (2002) Med. Phys. , vol.29 , pp. 1611-1621
    • Srinivas, Y.1    Wilson, D.L.2
  • 16
    • 0032800112 scopus 로고    scopus 로고
    • Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors
    • Stierstorfer K and Spahn M 1999 Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors Med. Phys. 26 1312-9
    • (1999) Med. Phys. , vol.26 , pp. 1312-1319
    • Stierstorfer, K.1    Spahn, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.