Volumn 64, Issue 7, 2009, Pages 762-769

Performance of three minimally invasive cardiac output monitoring systems

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; CLINICAL ARTICLE; DEVICE; HEART OUTPUT; HEART SURGERY; HUMAN; PATIENT MONITORING; PATIENT POSITIONING; PERFORMANCE; POSITIVE END EXPIRATORY PRESSURE; PRESSORECEPTOR; THERMODILUTION; TIDAL VOLUME; ULTRASOUND;

EID: 67650330148     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2009.05934.x     Document Type: Article
Times cited : (44)

References (28)
  • 1
    • 0029992651 scopus 로고    scopus 로고
    • Delayed time response of the continuous cardiac output pulmonary artery catheter
    • Siegel LC, Hennessy MM, Pearl RG. Delayed time response of the continuous cardiac output pulmonary artery catheter. Anesthesia and Analgesia 1996; 83: 1173-1177 (Pubitemid 26418799)
    • (1996) Anesthesia and Analgesia , vol.83 , Issue.6 , pp. 1173-1177
    • Siegel, L.C.1    Hennessy, M.M.2    Pearl, R.G.3
  • 2
    • 0032435617 scopus 로고    scopus 로고
    • Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes
    • DOI 10.1097/00000542-199812000-00047
    • Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG. Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998; 89: 1592-1595 (Pubitemid 29001608)
    • (1998) Anesthesiology , vol.89 , Issue.6 , pp. 1592-1595
    • Aranda, M.1    Mihm, F.G.2    Garrett, S.3    Mihm, M.N.4    Pearl, R.G.5
  • 3
    • 26844502897 scopus 로고    scopus 로고
    • Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    • DOI 10.1586/17434440.2.5.523
    • Manecke GR. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Review of Medical Devices 2005; 2: 523-527 (Pubitemid 41447649)
    • (2005) Expert Review of Medical Devices , vol.2 , Issue.5 , pp. 523-527
    • Manecke, G.R.1
  • 4
    • 34548266524 scopus 로고    scopus 로고
    • Clinical evaluation of the FloTrac/Vigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    • DOI 10.1093/bja/aem188
    • Button D, Weibel L, Reuthebuch O, Genoni M, Zollinger A, Hofer CK. Clinical evaluation of the FloTrac/Vigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. British Journal of Anaesthesia 2007; 99: 329-336 (Pubitemid 47316385)
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.3 , pp. 329-336
    • Button, D.1    Weibel, L.2    Reuthebuch, O.3    Genoni, M.4    Zollinger, A.5    Hofer, C.K.6
  • 6
    • 34648816655 scopus 로고    scopus 로고
    • Cardiac Output Measured by a New Arterial Pressure Waveform Analysis Method Without Calibration Compared with Thermodilution after Cardiac Surgery
    • DOI 10.1053/j.jvca.2007.01.001, PII S1053077007000031
    • Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld AB. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. Journal Cardiothorac and Vascular Anesthesia 2007; 21: 632-635 (Pubitemid 47464948)
    • (2007) Journal of Cardiothoracic and Vascular Anesthesia , vol.21 , Issue.5 , pp. 632-635
    • Breukers, R.1    Sepehrkhouy, S.2    Spiegelenberg, S.R.3    Groeneveld, A.B.J.4
  • 7
    • 39749138803 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: Validity of a second generation device
    • DOI 10.1213/ane.0b013e318161964d, PII 0000053920080300000027
    • Mayer J, Boldt J, Wolf MW, Lang J, Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device. Anesthesia and Analgesia 2008; 106: 867-872, table. (Pubitemid 351301408)
    • (2008) Anesthesia and Analgesia , vol.106 , Issue.3 , pp. 867-872
    • Mayer, J.1    Boldt, J.2    Wolf, M.W.3    Lang, J.4    Suttner, S.5
  • 9
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • Wesseling KH, Jansen JR, Settels JJ, Schreuder JJ. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. Journal of Applied Physiology 1993; 74: 2566-2573 (Pubitemid 23157090)
    • (1993) Journal of Applied Physiology , vol.74 , Issue.5 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.C.2    Settels, J.J.3    Schreuder, J.J.4
  • 10
    • 0032753839 scopus 로고    scopus 로고
    • Estimation of beat-to-beat changes in stroke volume from arterial pressure: A comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men
    • Jellema WT, Imholz BP, Oosting H, Wesseling KH, van LieshoutJJ. Estimation of beat-to-beat changes in stroke volume from arterial pressure: a comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men. Clinical Autonomic Research 1999; 9: 185-192
    • (1999) Clinical Autonomic Research , vol.9 , pp. 185-192
    • Jellema, W.T.1    Imholz, B.P.2    Oosting, H.3    Wesseling, K.H.4    Van Lieshout, J.J.5
  • 11
    • 0034869820 scopus 로고    scopus 로고
    • A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    • DOI 10.1093/bja/87.2.212
    • Jansen JR, Schreuder JJ, Mulier JP, Smith NT, Settels JJ, Wesseling KH. A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients. British Journal of Anaesthesia 2001; 87: 212-222 (Pubitemid 32750529)
    • (2001) British Journal of Anaesthesia , vol.87 , Issue.2 , pp. 212-222
    • Jansen, J.R.C.1    Schreuder, J.J.2    Mulier, J.P.3    Smith, N.T.4    Settels, J.J.5    Wesseling, K.H.6
  • 14
    • 0033788304 scopus 로고    scopus 로고
    • Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000
    • DOI 10.1023/A:1009902517388
    • Boulnois JL, Pechoux T. Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000. Journal of Clinical Monitoring and Computing 2000; 16: 127-140 (Pubitemid 30801982)
    • (2000) Journal of Clinical Monitoring and Computing , vol.16 , Issue.2 , pp. 127-140
    • Boulnois, J.-L.G.1    Pechoux, T.2
  • 16
    • 0022617227 scopus 로고
    • Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
    • Jansen JR, Versprille A. Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation. Intensive Care Medicine 1986; 12: 71-79 (Pubitemid 16162642)
    • (1986) Intensive Care Medicine , vol.12 , Issue.2 , pp. 71-79
    • Jansen, J.R.C.1    Versprille, A.2
  • 18
    • 0025650019 scopus 로고
    • Continuous cardiac output monitoring by pulse contour during cardiac surgery
    • Jansen JR, Wesseling KH, Settels JJ, Schreuder JJ. Continuous cardiac output monitoring by pulse contour during cardiac surgery. European Heart Journal 1990; 11 (Suppl. I): 26-32.
    • (1990) European Heart Journal , vol.11 , Issue.SUPPL. I , pp. 26-32
    • Jansen, J.R.1    Wesseling, K.H.2    Settels, J.J.3    Schreuder, J.J.4
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 34548208591 scopus 로고    scopus 로고
    • I. Using the Bland-Altman method to measure agreement with repeated measures
    • DOI 10.1093/bja/aem214
    • Myles PS, Cui JI. Using the Bland Altman method to measure agreement with repeated measures. British Journal of Anaesthesia 2007; 99: 309-311 (Pubitemid 47316383)
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.3 , pp. 309-311
    • Myles, P.S.1    Cui, J.2
  • 21
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. Journal of Clinical Monitoring and Computing 1999; 15: 85-91. (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 23
    • 0035147673 scopus 로고    scopus 로고
    • Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: A case report
    • Nelson N, Janerot-Sjoberg B. Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report. Critical Care 2001; 5: 41-45 (Pubitemid 32120626)
    • (2001) Critical Care , vol.5 , Issue.1 , pp. 41-45
    • Nelson, N.1    Janerot-Sjoberg, B.2
  • 24
    • 0042423725 scopus 로고    scopus 로고
    • Clinical evaluation of the HemoSonic monitor in cardiac surgical patients in the ICU
    • Moxon D, Pinder M, van Heerden PV, Parsons RW. Clinical evaluation of the HemoSonic monitor in cardiac surgical patients in the ICU. Anaesthesia and Intensive Care 2003; 31: 408-411 (Pubitemid 37038512)
    • (2003) Anaesthesia and Intensive Care , vol.31 , Issue.4 , pp. 408-411
    • Moxon, D.1    Pinder, M.2    Van Heerden, P.V.3    Parsons, R.W.4
  • 25
    • 0036744725 scopus 로고    scopus 로고
    • Cardiac output measurement during cardiac surgery: Esophageal Doppler versus pulmonary artery catheter
    • Su NY, Huang CJ, Tsai P, Hsu YW, Hung YC, Cheng CR. Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter. Acta Anaesthesiologica Sinica 2002; 40: 127-133
    • (2002) Acta Anaesthesiologica Sinica , vol.40 , pp. 127-133
    • Su, N.Y.1    Huang, C.J.2    Tsai, P.3    Hsu, Y.W.4    Hung, Y.C.5    Cheng, C.R.6
  • 26
    • 0242556407 scopus 로고    scopus 로고
    • Change in stroke volume in response to fluid challenge: Assessment using esophageal Doppler
    • DOI 10.1007/s00134-003-1720-4
    • Roeck M, Jakob SM, Boehlen T, Brander L, Knuesel R, Takala J. Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler. Intensive Care Medicine 2003; 29: 1729-1735 (Pubitemid 37373817)
    • (2003) Intensive Care Medicine , vol.29 , Issue.10 , pp. 1729-1735
    • Roeck, M.1    Jakob, S.M.2    Boehlen, T.3    Brander, L.4    Knuesel, R.5    Takala, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.