Volumn 9, Issue 4, 1999, Pages 185-192

Estimation of beat-to-beat changes in stroke volume from arterial pressure: A comparison of two pressure wave analysis techniques during head- up tilt testing in young, healthy men

Author keywords

Aortic impedance; Blood pressure; Finapres; Head up tilt; Pulse contour; Simulation; Stroke volume

Indexed keywords

ADULT; AORTA; ARTICLE; BRACHIAL ARTERY; CONTROLLED STUDY; EXERCISE TEST; HEAD TILTING; HEART STROKE VOLUME; HUMAN; HUMAN EXPERIMENT; IMPEDANCE; MALE; MATHEMATICAL MODEL; MEAN ARTERIAL PRESSURE; NORMAL HUMAN; ORTHOSTATIC HYPOTENSION; VERTIGO;

EID: 0032753839     PISSN: 09599851     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02330482     Document Type: Article
Times cited : (49)

References (34)
  • 1
    • 0030199184 scopus 로고    scopus 로고
    • Tilt table testing for assessing syncope
    • American College of Cardiology
    • Benditt DG, Ferguson DW, Grubb BP, et al. Tilt table testing for assessing syncope. American College of Cardiology. J Am Coll Cardiol 1996; 28:263-275.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 263-275
    • Benditt, D.G.1    Ferguson, D.W.2    Grubb, B.P.3
  • 2
    • 0029886270 scopus 로고    scopus 로고
    • Clinical approach to cardio-vascular reflex testing
    • Smit AAJ, Wieling W, Karemaker JM, Clinical approach to cardio-vascular reflex testing. Clin Sci 1996; 91 (Suppl):108-112.
    • (1996) Clin Sci , vol.91 , Issue.SUPPL. , pp. 108-112
    • Smit, A.A.J.1    Wieling, W.2    Karemaker, J.M.3
  • 3
    • 0013877001 scopus 로고
    • Cardiovascular dynamics during orthostasis and the influence of intravascular instrumentation
    • Stevens PM. Cardiovascular dynamics during orthostasis and the influence of intravascular instrumentation. Am J Cardiol 1966; 17:211-218.
    • (1966) Am J Cardiol , vol.17 , pp. 211-218
    • Stevens, P.M.1
  • 4
    • 0001856401 scopus 로고
    • General response to orthostatic stress
    • Smith JJ, Ed. Boca Raton, FL: CRC Press
    • Smith JJ, Ebert, J. General response to orthostatic stress. In: Smith JJ, Ed. Circulatory Response to the Upright Posture. Boca Raton, FL: CRC Press; 1990:1-46.
    • (1990) Circulatory Response to the Upright Posture , pp. 1-46
    • Smith, J.J.1    Ebert, J.2
  • 5
    • 0032102644 scopus 로고    scopus 로고
    • Fifteen years experience with finger arterial pressure monitoring: Assessment of the technology
    • Imholz BPM, Wieling W, Van Montfrans GA, et al. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res 1998; 38:605-616.
    • (1998) Cardiovasc Res , vol.38 , pp. 605-616
    • Imholz, B.P.M.1    Wieling, W.2    Van Montfrans, G.A.3
  • 6
    • 0029736631 scopus 로고    scopus 로고
    • Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects
    • Jellema WT, Imholz BPM, Van Goudoever J, et al. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects. Clin Sci 1996; 91:193-200.
    • (1996) Clin Sci , vol.91 , pp. 193-200
    • Jellema, W.T.1    Imholz, B.P.M.2    Van Goudoever, J.3
  • 7
    • 0029396344 scopus 로고
    • A comparison of non-invasive continuous finger blood pressure measurement (Finapres) with intra-arterial pressure during prolonged head-up tilt
    • Petersen ME, Williams TR, Sutton R. A comparison of non-invasive continuous finger blood pressure measurement (Finapres) with intra-arterial pressure during prolonged head-up tilt. Eur Heart J 1995; 16:1641-1654.
    • (1995) Eur Heart J , vol.16 , pp. 1641-1654
    • Petersen, M.E.1    Williams, T.R.2    Sutton, R.3
  • 8
    • 0014819412 scopus 로고
    • Application of impedance cardiography to study of postural stress
    • Smith JJ, Bush JE, Wiedmeier VT, et al. Application of impedance cardiography to study of postural stress. J Appl Physiol 1970; 29:133-137.
    • (1970) J Appl Physiol , vol.29 , pp. 133-137
    • Smith, J.J.1    Bush, J.E.2    Wiedmeier, V.T.3
  • 10
    • 0030767783 scopus 로고    scopus 로고
    • A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography
    • Marik PE, Pendelton JE, Smith R. A comparison of hemodynamic parameters derived from transthoracic electrical bioimpedance with those parameters obtained by thermodilution and ventricular angiography. Crit Care Med 1997; 25:1545-1550.
    • (1997) Crit Care Med , vol.25 , pp. 1545-1550
    • Marik, P.E.1    Pendelton, J.E.2    Smith, R.3
  • 11
    • 0021249532 scopus 로고
    • The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model
    • Langewouters GJ, Wesseling KH, Goedhard WJA. The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model. J Biomech 1984; 17:425-535.
    • (1984) J Biomech , vol.17 , pp. 425-535
    • Langewouters, G.J.1    Wesseling, K.H.2    Goedhard, W.J.A.3
  • 12
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • Wesseling KH, Jansen JRC, Settels JJ, et al. Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J Appl Physiol 1993; 74:2566-2573.
    • (1993) J Appl Physiol , vol.74 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.C.2    Settels, J.J.3
  • 14
    • 0001945079 scopus 로고
    • Physiocal, calibrating finger vascular physiology for Finapres
    • Wesseling KH, De Wit B, Van der Hoeven GMA, et al. Physiocal, calibrating finger vascular physiology for Finapres. Homeostasis 1995; 36:67-82.
    • (1995) Homeostasis , vol.36 , pp. 67-82
    • Wesseling, K.H.1    De Wit, B.2    Van der Hoeven, G.M.A.3
  • 15
    • 0002765004 scopus 로고
    • A simple device for the continuous measurement of cardiac output
    • Wesseling KH, De Wit B, Weber JAP, et al. A simple device for the continuous measurement of cardiac output. Adv Cardiovasc Physics 1983; 5-11:16-52.
    • (1983) Adv Cardiovasc Physics , vol.5-11 , pp. 16-52
    • Wesseling, K.H.1    De Wit, B.2    Weber, J.A.P.3
  • 16
    • 0025650019 scopus 로고
    • Continuous cardiac output monitoring by pulse contour during cardiac surgery
    • Jansen JRC, Wesseling KH, Settels JJ, et al. Continuous cardiac output monitoring by pulse contour during cardiac surgery. Eur Heart J 1990; 11 (Suppl):26-32.
    • (1990) Eur Heart J , vol.11 , Issue.SUPPL. , pp. 26-32
    • Jansen, J.R.C.1    Wesseling, K.H.2    Settels, J.J.3
  • 17
    • 0027176837 scopus 로고
    • Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing
    • Stok WJ, Baisch F, Hillebrecht A. et al. Noninvasive cardiac output measurement by arterial pulse analysis compared with inert gas rebreathing. J Appl Physiol 1993; 74:2687-2693.
    • (1993) J Appl Physiol , vol.74 , pp. 2687-2693
    • Stok, W.J.1    Baisch, F.2    Hillebrecht, A.3
  • 18
    • 0015147582 scopus 로고
    • An artificial arterial system for pumping hearts
    • Westerhof N, Elzinga G, Sipkema P. An artificial arterial system for pumping hearts. J Appl Physiol 1971; 31:776-781.
    • (1971) J Appl Physiol , vol.31 , pp. 776-781
    • Westerhof, N.1    Elzinga, G.2    Sipkema, P.3
  • 19
    • 0023730394 scopus 로고
    • Assessment of Windkessel as a model of aortic input impedance
    • Burkhoff D, Alexander JJ, Schipke J. Assessment of Windkessel as a model of aortic input impedance. Am J Physiol 1988; 255:H742-H753.
    • (1988) Am J Physiol , vol.255
    • Burkhoff, D.1    Alexander, J.J.2    Schipke, J.3
  • 20
    • 0032942194 scopus 로고    scopus 로고
    • Continuous cardiac output in septic shock by simulating a model of the aortic input impedance. A comparison with bolus injection thermodilution
    • Jellema WT, Wesseling KH, Groeneveld ABJ, et al. Continuous cardiac output in septic shock by simulating a model of the aortic input impedance. A comparison with bolus injection thermodilution. Anesthesiology 1999; 90:1317-1328.
    • (1999) Anesthesiology , vol.90 , pp. 1317-1328
    • Jellema, W.T.1    Wesseling, K.H.2    Groeneveld, A.B.J.3
  • 21
    • 0030733450 scopus 로고    scopus 로고
    • Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform
    • Hirschl MM, Binder M, Gwechenberger M, et al. Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform. Crit Care Med 1997; 25:1909-1914.
    • (1997) Crit Care Med , vol.25 , pp. 1909-1914
    • Hirschl, M.M.1    Binder, M.2    Gwechenberger, M.3
  • 22
    • 0005928630 scopus 로고    scopus 로고
    • Continuous stroke volume by modelling flow from non-invasive arterial pressure in humans under orthostatic stress
    • in press
    • Harms MPM, Wesseling KH, Pott F, et al. Continuous stroke volume by modelling flow from non-invasive arterial pressure in humans under orthostatic stress. Clin Sci 1999, in press.
    • (1999) Clin Sci
    • Harms, M.P.M.1    Wesseling, K.H.2    Pott, F.3
  • 23
    • 0029818936 scopus 로고    scopus 로고
    • Reconstruction of brachial artery pressure from noninvasive finger pressure measurements
    • Bos WJW, Van Goudoever J, Van Montfrans GA, et al. Reconstruction of brachial artery pressure from noninvasive finger pressure measurements. Circulation 1996; 94:1870-1875.
    • (1996) Circulation , vol.94 , pp. 1870-1875
    • Bos, W.J.W.1    Van Goudoever, J.2    Van Montfrans, G.A.3
  • 24
    • 0030758224 scopus 로고    scopus 로고
    • Finger-to-brachial comparability of "Modelflow" stroke volume improves after pulsewave reconstruction
    • Voogel AJ, Bos WJW, Van Goudoever J, Van Montfrans GA, Wesseling KH. Finger-to-brachial comparability of "Modelflow" stroke volume improves after pulsewave reconstruction. Clin Physiol 1997; 17:327-337.
    • (1997) Clin Physiol , vol.17 , pp. 327-337
    • Voogel, A.J.1    Bos, W.J.W.2    Van Goudoever, J.3    Van Montfrans, G.A.4    Wesseling, K.H.5
  • 25
    • 0003503387 scopus 로고
    • New York: John Wiley and Sons
    • Ward A. Sequential Analysis. New York: John Wiley and Sons; 1947.
    • (1947) Sequential Analysis
    • Ward, A.1
  • 26
    • 0026080696 scopus 로고
    • Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance
    • Sprangers RLH, Wesseling KH, Imhotz ALT, et al. Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. J Appl Physiol 1991; 70:523-530.
    • (1991) J Appl Physiol , vol.70 , pp. 523-530
    • Sprangers, R.L.H.1    Wesseling, K.H.2    Imhotz, A.L.T.3
  • 27
    • 0000761417 scopus 로고
    • Pressure wave transmission along the human aorta; Changes with age and in arterial degenerative disease
    • O'Rourke MF, Blazek JV, Moreels CL, et al. Pressure wave transmission along the human aorta; changes with age and in arterial degenerative disease. Circ Res 1955; 3:623-631.
    • (1955) Circ Res , vol.3 , pp. 623-631
    • O'Rourke, M.F.1    Blazek, J.V.2    Moreels, C.L.3
  • 28
    • 0032102644 scopus 로고    scopus 로고
    • Fifteen years experience with finger arterial pressure monitoring: Assessment of the technology
    • Imholz BPM, Wieling W, Van Montfrans GA, et al. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res 1998; 38:605-616.
    • (1998) Cardiovasc Res , vol.38 , pp. 605-616
    • Imholz, B.P.M.1    Wieling, W.2    Van Montfrans, G.A.3
  • 29
    • 0026637505 scopus 로고
    • The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease
    • Bos WJW, Imholz BPM, Van Goudoever J, et al. The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease. Am J Hypertens 1992; 5:529-535.
    • (1992) Am J Hypertens , vol.5 , pp. 529-535
    • Bos, W.J.W.1    Imholz, B.P.M.2    Van Goudoever, J.3
  • 30
    • 0027460281 scopus 로고
    • An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man
    • Karamanoglu M, O'Rourke MF, Avolio AP, et al. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J 1993; 14:160-167.
    • (1993) Eur Heart J , vol.14 , pp. 160-167
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3
  • 31
    • 0028930125 scopus 로고
    • Comparison of cardiac output measurement techniques: Thermodilution, Doppler, CO2-rebreathing and the direct Fick method
    • Espersen K, Jensen EW, Rosenborg D, et al. Comparison of cardiac output measurement techniques: thermodilution, Doppler, CO2-rebreathing and the direct Fick method. Acta Anaesthesiol Scand 1995; 39:245-251.
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 245-251
    • Espersen, K.1    Jensen, E.W.2    Rosenborg, D.3
  • 32
    • 0025242457 scopus 로고
    • Improved method for cardiac output determination in man using ultrasound Doppler technique
    • Eriksen M, Walloe L. Improved method for cardiac output determination in man using ultrasound Doppler technique. Med Biol Eng Comput. 1990; 28:555-560.
    • (1990) Med Biol Eng Comput , vol.28 , pp. 555-560
    • Eriksen, M.1    Walloe, L.2
  • 33
    • 0009550689 scopus 로고    scopus 로고
    • Comparison of pulse contour and impedance cardiograph measurements of stroke volume and cardiac output during head-up tilt
    • Schondorf R, Cameli L, Benoit J, et al. Comparison of pulse contour and impedance cardiograph measurements of stroke volume and cardiac output during head-up tilt (abstract). Clin Autonom Res 1997; 7:265.
    • (1997) Clin Autonom Res , vol.7 , pp. 265
    • Schondorf, R.1    Cameli, L.2    Benoit, J.3
  • 34
    • 4243350093 scopus 로고    scopus 로고
    • Non-invasive continuous cardiac stroke volume monitoring: Evaluation of a novel technique
    • Abstract
    • Van Lieshout EJ, Toska K, Eriksen M, et al. Non-invasive continuous cardiac stroke volume monitoring: evaluation of a novel technique. Neth J Med 1998; 52:A44 (Abstract).
    • (1998) Neth J Med , vol.52
    • Van Lieshout, E.J.1    Toska, K.2    Eriksen, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.