메뉴 건너뛰기




Volumn 12, Issue 2, 2009, Pages 186-194

Bone and Muscle Parameters of the Tibia: Agreement Between the XCT 2000 and XCT 3000 Instruments

Author keywords

Bone geometry; bone strength; peripheral quantitative computed tomography; tibia

Indexed keywords

ACCURACY; ADULT; ARTICLE; BONE DENSITY; BONE GROWTH; BONE STRENGTH; COMPARATIVE STUDY; CORTICAL BONE; FEMALE; HUMAN; MALE; NORMAL HUMAN; PRIORITY JOURNAL; TIBIA; TRABECULAR BONE;

EID: 67349088732     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jocd.2008.09.005     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 9344263428 scopus 로고    scopus 로고
    • Noninvasive assessment of bone mineral and structure: state of the art
    • Genant H.K., Engelke K., Fuerst T., et al. Noninvasive assessment of bone mineral and structure: state of the art. J Bone Miner Res 11 (1996) 707-730
    • (1996) J Bone Miner Res , vol.11 , pp. 707-730
    • Genant, H.K.1    Engelke, K.2    Fuerst, T.3
  • 2
    • 0028789562 scopus 로고
    • Cortical thickness assessed by peripheral quantitative computed tomography: accuracy evaluated on radius specimens
    • Louis O., Willnecker J., Soykens S., et al. Cortical thickness assessed by peripheral quantitative computed tomography: accuracy evaluated on radius specimens. Osteoporos Int 5 (1995) 446-449
    • (1995) Osteoporos Int , vol.5 , pp. 446-449
    • Louis, O.1    Willnecker, J.2    Soykens, S.3
  • 3
    • 0029940024 scopus 로고    scopus 로고
    • Cortical and total bone mineral content of the radius: accuracy of peripheral computed tomography
    • Louis O., Soykens S., Willnecker J., et al. Cortical and total bone mineral content of the radius: accuracy of peripheral computed tomography. Bone 18 (1996) 467-472
    • (1996) Bone , vol.18 , pp. 467-472
    • Louis, O.1    Soykens, S.2    Willnecker, J.3
  • 4
    • 0029953581 scopus 로고    scopus 로고
    • Accuracy and precision study in vitro for peripheral quantitative computed tomography
    • Takada M., Engelke K., Hagiwara S., et al. Accuracy and precision study in vitro for peripheral quantitative computed tomography. Osteoporos Int 6 (1996) 207-212
    • (1996) Osteoporos Int , vol.6 , pp. 207-212
    • Takada, M.1    Engelke, K.2    Hagiwara, S.3
  • 5
    • 0031715104 scopus 로고    scopus 로고
    • Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT)
    • Augat P., Gordon C.L., Lang T.F., et al. Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT). Phys Med Biol 43 (1998) 2873-2883
    • (1998) Phys Med Biol , vol.43 , pp. 2873-2883
    • Augat, P.1    Gordon, C.L.2    Lang, T.F.3
  • 6
    • 17344386754 scopus 로고    scopus 로고
    • Precision and inter-site correlation of bone densitometry at the radius, tibia and femur with peripheral quantitative CT
    • Groll O., Lochmüller E.M., Bachmeier M., et al. Precision and inter-site correlation of bone densitometry at the radius, tibia and femur with peripheral quantitative CT. Skeletal Radiol 28 (1999) 696-702
    • (1999) Skeletal Radiol , vol.28 , pp. 696-702
    • Groll, O.1    Lochmüller, E.M.2    Bachmeier, M.3
  • 7
    • 3042696947 scopus 로고    scopus 로고
    • Accuracy and precision of peripheral quantitative computed tomography measurements at the tibial metaphysis
    • Veitch S.W., Findlay S.C., Ingle B.M., et al. Accuracy and precision of peripheral quantitative computed tomography measurements at the tibial metaphysis. J Clin Densitom 7 (2004) 209-217
    • (2004) J Clin Densitom , vol.7 , pp. 209-217
    • Veitch, S.W.1    Findlay, S.C.2    Ingle, B.M.3
  • 8
    • 33846673917 scopus 로고    scopus 로고
    • Analyzing cortical bone cross-sectional geometry by peripheral QCT: comparison with bone histomorphometry
    • Kontulainen S., Liu D., Manske S., et al. Analyzing cortical bone cross-sectional geometry by peripheral QCT: comparison with bone histomorphometry. J Clin Densitom 10 (2007) 86-92
    • (2007) J Clin Densitom , vol.10 , pp. 86-92
    • Kontulainen, S.1    Liu, D.2    Manske, S.3
  • 9
    • 0028310322 scopus 로고
    • Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population
    • Butz S., Wüster C., Scheidt-Nave C., et al. Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population. Osteoporos Int 4 (1994) 179-184
    • (1994) Osteoporos Int , vol.4 , pp. 179-184
    • Butz, S.1    Wüster, C.2    Scheidt-Nave, C.3
  • 10
    • 0029131195 scopus 로고
    • Assessment of the skeletal status by peripheral quantitative computed tomography of the forearm: short-term precision in vivo and comparison to dual x-ray absorptiometry
    • Grampp S., Lang P., Jergas M., et al. Assessment of the skeletal status by peripheral quantitative computed tomography of the forearm: short-term precision in vivo and comparison to dual x-ray absorptiometry. J Bone Miner Res 10 (1995) 1566-1576
    • (1995) J Bone Miner Res , vol.10 , pp. 1566-1576
    • Grampp, S.1    Lang, P.2    Jergas, M.3
  • 11
    • 0031976865 scopus 로고    scopus 로고
    • Peripheral quantitative computed tomography in human long bones: evaluation of in vitro and in vivo precision
    • Sievanen H., Koskue V., Rauhio A., et al. Peripheral quantitative computed tomography in human long bones: evaluation of in vitro and in vivo precision. J Bone Miner Res 13 (1998) 871-882
    • (1998) J Bone Miner Res , vol.13 , pp. 871-882
    • Sievanen, H.1    Koskue, V.2    Rauhio, A.3
  • 12
    • 0034012703 scopus 로고    scopus 로고
    • pQCT measurement of bone parameters in young children: validation of technique
    • Binkley T.L., and Specker B.L. pQCT measurement of bone parameters in young children: validation of technique. J Clin Densitom 3 (2000) 9-14
    • (2000) J Clin Densitom , vol.3 , pp. 9-14
    • Binkley, T.L.1    Specker, B.L.2
  • 13
    • 26444560337 scopus 로고    scopus 로고
    • Peripheral quantitative computed tomography at the distal radius: cross-calibration between two scanners
    • Rauch F., Tutlewski B., and Schoenau E. Peripheral quantitative computed tomography at the distal radius: cross-calibration between two scanners. J Musculoskelet Neuronal Interact 2 (2001) 153-155
    • (2001) J Musculoskelet Neuronal Interact , vol.2 , pp. 153-155
    • Rauch, F.1    Tutlewski, B.2    Schoenau, E.3
  • 14
    • 28244436466 scopus 로고    scopus 로고
    • Recommendations for thresholds for cortical bone geometry and density measurement by peripheral quantitative computed tomography
    • Ward K., Adams J., and Hangartner T. Recommendations for thresholds for cortical bone geometry and density measurement by peripheral quantitative computed tomography. Calcif Tissue Int 77 (2005) 275-280
    • (2005) Calcif Tissue Int , vol.77 , pp. 275-280
    • Ward, K.1    Adams, J.2    Hangartner, T.3
  • 15
    • 0031827407 scopus 로고    scopus 로고
    • Clinical evaluation of a high resolution new peripheral quantitative computerised tomography scanner for the bone densitometry at the lower limbs
    • Braun M.J., Meta M.D., Schneider P., and Reiners C. Clinical evaluation of a high resolution new peripheral quantitative computerised tomography scanner for the bone densitometry at the lower limbs. Phys Med Biol 43 (1998) 2279-2294
    • (1998) Phys Med Biol , vol.43 , pp. 2279-2294
    • Braun, M.J.1    Meta, M.D.2    Schneider, P.3    Reiners, C.4
  • 16
    • 20444386087 scopus 로고    scopus 로고
    • Does tibial bone structure differ between girls who completed a 20-month exercise intervention and controls?
    • Macdonald H.M., MacKelvie K.J., MacLean L.B., and McKay H.A. Does tibial bone structure differ between girls who completed a 20-month exercise intervention and controls?. Med Sci Sports Exerc 35 (2003) S360
    • (2003) Med Sci Sports Exerc , vol.35
    • Macdonald, H.M.1    MacKelvie, K.J.2    MacLean, L.B.3    McKay, H.A.4
  • 17
    • 20444403032 scopus 로고    scopus 로고
    • Maturity- and sex-related changes in tibial bone geometry, strength and bone-muscle strength indices during growth: a 20-month pQCT study
    • Macdonald H.M., Kontulainen S.A., MacKelvie-O'Brien K.J., et al. Maturity- and sex-related changes in tibial bone geometry, strength and bone-muscle strength indices during growth: a 20-month pQCT study. Bone 36 (2005) 1003-1011
    • (2005) Bone , vol.36 , pp. 1003-1011
    • Macdonald, H.M.1    Kontulainen, S.A.2    MacKelvie-O'Brien, K.J.3
  • 19
    • 33746679196 scopus 로고    scopus 로고
    • Bone strength and its determinants in pre- and early pubertal boys and girls
    • Macdonald H., Kontulainen S., Petit M., et al. Bone strength and its determinants in pre- and early pubertal boys and girls. Bone 39 (2006) 598-608
    • (2006) Bone , vol.39 , pp. 598-608
    • Macdonald, H.1    Kontulainen, S.2    Petit, M.3
  • 20
    • 33745787503 scopus 로고    scopus 로고
    • Change in cortical bone density and its distribution differs between boys and girls during puberty
    • Kontulainen S.A., Macdonald H.M., and McKay H.A. Change in cortical bone density and its distribution differs between boys and girls during puberty. J Clin Endocrinol Metab 91 (2006) 2555-2561
    • (2006) J Clin Endocrinol Metab , vol.91 , pp. 2555-2561
    • Kontulainen, S.A.1    Macdonald, H.M.2    McKay, H.A.3
  • 21
    • 34247261570 scopus 로고    scopus 로고
    • Is a school-based physical activity intervention effective for increasing tibial bone strength in boys and girls?
    • Macdonald H.M., Kontulainen S.A., Khan K.M., and McKay H.A. Is a school-based physical activity intervention effective for increasing tibial bone strength in boys and girls?. J Bone Miner Res 22 (2007) 434-446
    • (2007) J Bone Miner Res , vol.22 , pp. 434-446
    • Macdonald, H.M.1    Kontulainen, S.A.2    Khan, K.M.3    McKay, H.A.4
  • 22
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i (1986) 307-310
    • (1986) Lancet , vol.i , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison
    • Bland D.G., and Altman M.J. Measuring agreement in method comparison. Stat Methods Med Res 8 (1999) 135-160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, D.G.1    Altman, M.J.2
  • 24
    • 0031704384 scopus 로고    scopus 로고
    • Comparison and cross calibration of DXA systems: ODX-240 and Sophos L-XRA versus Hologic QDR-4500, for spinal bone mineral measurement. Translation of a reference database
    • Benmalek A., and Sabatier J.P. Comparison and cross calibration of DXA systems: ODX-240 and Sophos L-XRA versus Hologic QDR-4500, for spinal bone mineral measurement. Translation of a reference database. Osteoporos Int 8 (1998) 570-577
    • (1998) Osteoporos Int , vol.8 , pp. 570-577
    • Benmalek, A.1    Sabatier, J.P.2
  • 25
    • 0027532266 scopus 로고
    • Cross-calibration of DXA equipment: upgrading from a Hologic QDR 1000/W to a QDR 2000
    • Faulkner K., Gluer C.C., Estilo M., and Genant H. Cross-calibration of DXA equipment: upgrading from a Hologic QDR 1000/W to a QDR 2000. Calcif Tissue Int 52 (1993) 79-84
    • (1993) Calcif Tissue Int , vol.52 , pp. 79-84
    • Faulkner, K.1    Gluer, C.C.2    Estilo, M.3    Genant, H.4
  • 26
    • 0032998150 scopus 로고    scopus 로고
    • Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters
    • Prevhal S., Engelke K., and Kalender W. Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys Med Biol 44 (1999) 751-764
    • (1999) Phys Med Biol , vol.44 , pp. 751-764
    • Prevhal, S.1    Engelke, K.2    Kalender, W.3
  • 27
    • 0346740454 scopus 로고
    • Constant cortical density is a requirement for the accurate measurement of cortical thickness by CT
    • Hangartner T., Gilsanz V., and State W. Constant cortical density is a requirement for the accurate measurement of cortical thickness by CT. Bone Miner Res 25 (1994) S4
    • (1994) Bone Miner Res , vol.25
    • Hangartner, T.1    Gilsanz, V.2    State, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.