메뉴 건너뛰기




Volumn 77, Issue 5, 2005, Pages 275-280

Recommendations for thresholds for cortical bone geometry and density measurement by peripheral quantitative computed tomography

Author keywords

Bone Geometry; Cortical density; Peripheral quantitative computed tomography; Thresholds

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BONE DENSITY; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; FEMALE; GEOMETRY; HUMAN; PHANTOM; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; THICKNESS;

EID: 28244436466     PISSN: 0171967X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00223-005-0031-x     Document Type: Article
Times cited : (74)

References (8)
  • 1
    • 0000246342 scopus 로고    scopus 로고
    • Peripheral quantitative computed tomography
    • Genant H, Guglielmi G, Jergas M (eds) Berlin, Heidelberg, Springer-Verlag
    • Schneider P, Reiners C (1998) Peripheral quantitative computed tomography. In: Genant H, Guglielmi G, Jergas M (eds) Bone densitometry and osteoporosis. Berlin, Heidelberg, Springer-Verlag, pp 349-363
    • (1998) Bone Densitometry and Osteoporosis , pp. 349-363
    • Schneider, P.1    Reiners, C.2
  • 2
    • 0025362507 scopus 로고
    • Relationship between forearm and vertebral mineral density in postmenopausal women with primary hyperparathyroidism
    • Wishart J, Horowitz M, Need A, Nordin BE (1990) Relationship between forearm and vertebral mineral density in postmenopausal women with primary hyperparathyroidism. Arch Intern Med 150:1329-1331
    • (1990) Arch Intern Med , vol.150 , pp. 1329-1331
    • Wishart, J.1    Horowitz, M.2    Need, A.3    Nordin, B.E.4
  • 3
    • 0029782287 scopus 로고    scopus 로고
    • Evaluation of cortical bone by computed tomography
    • Hangartner T, Gilsanz V (1996) Evaluation of cortical bone by computed tomography. J Bone Miner Res 11:1518-1525
    • (1996) J Bone Miner Res , vol.11 , pp. 1518-1525
    • Hangartner, T.1    Gilsanz, V.2
  • 4
    • 0032998150 scopus 로고    scopus 로고
    • Accuracy limits for the determination of cortical width and density: The influence of object size and CT imaging parameters
    • Prevhal S, Engelke K, Kalender W (1999) Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Physics Med Biol 44:751-764
    • (1999) Physics Med Biol , vol.44 , pp. 751-764
    • Prevhal, S.1    Engelke, K.2    Kalender, W.3
  • 5
    • 0034012703 scopus 로고    scopus 로고
    • pQCT measurement of bone parameters in young children - Validation of technique
    • Binkley T, Specker B (2000) pQCT measurement of bone parameters in young children - validation of technique. J Clin Densitom 3:9-14
    • (2000) J Clin Densitom , vol.3 , pp. 9-14
    • Binkley, T.1    Specker, B.2
  • 6
    • 0027742499 scopus 로고
    • A phantom for standardization and quality control in peripheral bone measurements by pQCT and DXA
    • Ruegsegger P, Kalender W (1993) A phantom for standardization and quality control in peripheral bone measurements by pQCT and DXA. Phys Med Biol 38:1963-1970
    • (1993) Phys Med Biol , vol.38 , pp. 1963-1970
    • Ruegsegger, P.1    Kalender, W.2
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet Vol:307-310
    • (1986) Lancet , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 8
    • 28244473145 scopus 로고    scopus 로고
    • Assessment of cortical bone mineral density by peripheral quantitative computed tomography in children: Impact of partial volume effects
    • Kibe L, Zemel BS, Leonard MB (2004) Assessment of cortical bone mineral density by peripheral quantitative computed tomography in children: impact of partial volume effects. J Bone Miner Res 19(Suppl 1):S230
    • (2004) J Bone Miner Res , vol.19 , Issue.1 SUPPL.
    • Kibe, L.1    Zemel, B.S.2    Leonard, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.