메뉴 건너뛰기




Volumn 18, Issue 5, 1996, Pages 467-472

Cortical and total bone mineral content of the radius: Accuracy of peripheral computed tomography

Author keywords

Bone mineral content; Calcium content; Peripheral quantitative computed tomography

Indexed keywords

ACCURACY; ADULT; AGED; ANALYTICAL ERROR; ARTICLE; ATOMIC ABSORPTION SPECTROMETRY; BONE MINERAL; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; FEMALE; HUMAN; HUMAN TISSUE; NEUTRON ACTIVATION ANALYSIS; RADIUS;

EID: 0029940024     PISSN: 87563282     EISSN: None     Source Type: Journal    
DOI: 10.1016/8756-3282(96)00040-3     Document Type: Article
Times cited : (56)

References (25)
  • 1
    • 0023179349 scopus 로고
    • Vertebral trabecular bone: Comparison of single and dual energy CT measurements with chemical analysis
    • Burgess, A., Colborne, B., and Zoffmann, E. Vertebral trabecular bone: Comparison of single and dual energy CT measurements with chemical analysis. J Comput Assist Tomogr 11:506-515; 1987.
    • (1987) J Comput Assist Tomogr , vol.11 , pp. 506-515
    • Burgess, A.1    Colborne, B.2    Zoffmann, E.3
  • 2
    • 0028310322 scopus 로고
    • Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population
    • Butz, S., Wüster, C., Scheidt-Nave, C., Götz, M., and Liegler, R. Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population. Osteopor Int 4:179-184; 1994.
    • (1994) Osteopor Int , vol.4 , pp. 179-184
    • Butz, S.1    Wüster, C.2    Scheidt-Nave, C.3    Götz, M.4    Liegler, R.5
  • 3
    • 0023905804 scopus 로고
    • Quantitative CT for determination of bone mineral density: A review
    • Cann, C. E. Quantitative CT for determination of bone mineral density: A review. Radiology 166:509-512; 1988.
    • (1988) Radiology , vol.166 , pp. 509-512
    • Cann, C.E.1
  • 4
    • 0023851634 scopus 로고
    • Vertebral mineral determination of quantitative computed tomography (QCT): Accuracy of single and dual energy measurements
    • Glüer, C., Reiser, U., Davis, C., Rutt, B., and Genant, H. K. Vertebral mineral determination of quantitative computed tomography (QCT): Accuracy of single and dual energy measurements. J Comput Assist Tomogr 12:242-258; 1988.
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 242-258
    • Glüer, C.1    Reiser, U.2    Davis, C.3    Rutt, B.4    Genant, H.K.5
  • 5
    • 0025358771 scopus 로고
    • Accuracy of dual energy radiographic absorptiometry of the lumbar spine: Cadaver study
    • Ho, C., Kim, R., Schaffer, M., and Sartoris, D. Accuracy of dual energy radiographic absorptiometry of the lumbar spine: Cadaver study. Radiology 176:171-173; 1990.
    • (1990) Radiology , vol.176 , pp. 171-173
    • Ho, C.1    Kim, R.2    Schaffer, M.3    Sartoris, D.4
  • 6
    • 0027361884 scopus 로고
    • Measurement of trabecular bone mineral density in the distal radius by two gamma-ray computed tomography scanners
    • Hosie, C. J. Measurement of trabecular bone mineral density in the distal radius by two gamma-ray computed tomography scanners. Physiol Meas 14:269-276; 1993.
    • (1993) Physiol Meas , vol.14 , pp. 269-276
    • Hosie, C.J.1
  • 7
    • 0027703734 scopus 로고
    • Cross-sectional geometrical properties and bone mineral contents of the human radius and ulna
    • Hsu, E., Patwardhan, A.C., Meade, K., Light, T., and Martin, W. Cross-sectional geometrical properties and bone mineral contents of the human radius and ulna. J Biomech 26:1307-1318; 1993.
    • (1993) J Biomech , vol.26 , pp. 1307-1318
    • Hsu, E.1    Patwardhan, A.C.2    Meade, K.3    Light, T.4    Martin, W.5
  • 8
    • 0021674163 scopus 로고
    • A post-processing dual energy technique for vertebral CT densitometry
    • Laval-Jeantet, A. M., Cann, C., Roger, B., and Dallant, P. A post-processing dual energy technique for vertebral CT densitometry. J Comput Assist Tomogr 8:1164-1167; 1984.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 1164-1167
    • Laval-Jeantet, A.M.1    Cann, C.2    Roger, B.3    Dallant, P.4
  • 10
    • 0026632784 scopus 로고
    • Dual energy X-ray absorptiometry of lumbar vertebrae: Relative contribution of body and posterior elements and accuracy in relation with neutron activation analysis
    • Louis, O., Van Den Winkel, P., Covens, P., Schoutens, A., and Osteaux, M. Dual energy X-ray absorptiometry of lumbar vertebrae: Relative contribution of body and posterior elements and accuracy in relation with neutron activation analysis. Bone 13:317-320; 1992.
    • (1992) Bone , vol.13 , pp. 317-320
    • Louis, O.1    Van Den Winkel, P.2    Covens, P.3    Schoutens, A.4    Osteaux, M.5
  • 11
    • 0028351511 scopus 로고
    • Mineral content of vertebral trabecular bone: Accuracy of dual energy quantitative computed tomography evaluated against neutron activation analysis and flame atomic absorption spectrometry
    • Louis, O., Van Den Winkel, P., Covens, P., Schoutens, A., and Osteaux, M. Mineral content of vertebral trabecular bone: Accuracy of dual energy quantitative computed tomography evaluated against neutron activation analysis and flame atomic absorption spectrometry. Bone 15:35-39; 1994.
    • (1994) Bone , vol.15 , pp. 35-39
    • Louis, O.1    Van Den Winkel, P.2    Covens, P.3    Schoutens, A.4    Osteaux, M.5
  • 12
    • 0029123722 scopus 로고
    • Cortical mineral content of the radius assessed by peripheral QCT predicts compressive strength on biomechanical testing
    • Louis, O., Boulpaep, F., Willnecker, J., Van Den Winkel, P., and Osteaux, M. Cortical mineral content of the radius assessed by peripheral QCT predicts compressive strength on biomechanical testing. Bone 16:375-379; 1995.
    • (1995) Bone , vol.16 , pp. 375-379
    • Louis, O.1    Boulpaep, F.2    Willnecker, J.3    Van Den Winkel, P.4    Osteaux, M.5
  • 13
    • 0028789562 scopus 로고
    • Cortical thickness assessed by peripheral quantitative computed tomography: Accuracy evaluated in radius specimens
    • Louis, O., Willnecker, J., Soykens, S., Van Den Winkel, P., and Osteaux, M. Cortical thickness assessed by peripheral quantitative computed tomography: Accuracy evaluated in radius specimens. Osteopor Int 5:466-449; 1995.
    • (1995) Osteopor Int , vol.5 , pp. 466-1449
    • Louis, O.1    Willnecker, J.2    Soykens, S.3    Van Den Winkel, P.4    Osteaux, M.5
  • 14
    • 0020531670 scopus 로고
    • Errors in measuring trabecular bone by computed tomography due to marrow and bone composition
    • Mazess, R. B. Errors in measuring trabecular bone by computed tomography due to marrow and bone composition. Calcif Tissue Int 35:148-152; 1983.
    • (1983) Calcif Tissue Int , vol.35 , pp. 148-152
    • Mazess, R.B.1
  • 15
    • 0024312025 scopus 로고
    • Peripheral QCT: A low risk procedure to identify women predisposed to osteoporosis
    • Müller, A., Rüegsegger, E., and Rüegsegger, P. Peripheral QCT: A low risk procedure to identify women predisposed to osteoporosis. Phys Med Biol 34:741-749; 1989.
    • (1989) Phys Med Biol , vol.34 , pp. 741-749
    • Müller, A.1    Rüegsegger, E.2    Rüegsegger, P.3
  • 16
    • 0026596676 scopus 로고
    • Bone mass measurements in the distal forearm using dual energy X-ray absorptiometry and γ-ray computed tomography: A longitudinal, in vivo comparative study
    • Verton, T. and Wheeler, G. D. Bone mass measurements in the distal forearm using dual energy X-ray absorptiometry and γ-ray computed tomography: A longitudinal, in vivo comparative study. J Bone Miner Res 7:371-375; 1992.
    • (1992) J Bone Miner Res , vol.7 , pp. 371-375
    • Verton, T.1    Wheeler, G.D.2
  • 17
    • 0022455793 scopus 로고
    • Assessment of cortical and trabecular bone distribution in the beagle skeleton by neutron activation analysis
    • Parks, N. J., Jee, W. S., Dell, R. B., and Miller, G. E. Assessment of cortical and trabecular bone distribution in the beagle skeleton by neutron activation analysis. Anat Rec 215:230-250; 1986.
    • (1986) Anat Rec , vol.215 , pp. 230-250
    • Parks, N.J.1    Jee, W.S.2    Dell, R.B.3    Miller, G.E.4
  • 18
    • 0028268457 scopus 로고
    • Quantitative peripheral computed tomodensitometry study of cortical and trabecular bone mass in relation with menopause
    • Rico, H., Diaz, H., Duran, C., Villa, L., and Penela, S. Quantitative peripheral computed tomodensitometry study of cortical and trabecular bone mass in relation with menopause. Maturitas 18:183-189; 1994.
    • (1994) Maturitas , vol.18 , pp. 183-189
    • Rico, H.1    Diaz, H.2    Duran, C.3    Villa, L.4    Penela, S.5
  • 19
    • 0025881432 scopus 로고
    • Differential effects of ageing and disease in trabecular and compact bone density of the radius
    • Rüegsegger, P., Durand, P., and Dambacher, M. A. Differential effects of ageing and disease in trabecular and compact bone density of the radius. Bone 12:99-105; 1991.
    • (1991) Bone , vol.12 , pp. 99-105
    • Rüegsegger, P.1    Durand, P.2    Dambacher, M.A.3
  • 20
    • 0343817859 scopus 로고
    • Periphere quantitative computertomographie zur knochenmineralmessung mit einem neuen speziallen QCT-Scanner
    • Schneider, P. and Börner, W. Periphere quantitative computertomographie zur Knochenmineralmessung mit einem neuen speziallen QCT-Scanner. Nuklear-mediciner 11:145-152; 1988.
    • (1988) Nuklear-mediciner , vol.11 , pp. 145-152
    • Schneider, P.1    Börner, W.2
  • 21
    • 0342512603 scopus 로고
    • Atomic spectroscopy based upon flame and electrothermal atomization
    • New York
    • Skoog, D. Atomic spectroscopy based upon flame and electrothermal atomization. Principles of instrumental analysis. New York: 1985.
    • (1985) Principles of Instrumental Analysis
    • Skoog, D.1
  • 22
    • 0029056614 scopus 로고
    • Impact of soft tissue on in vivo accuracy of bone numeral measurements in the spine, hip and forearm: A human cadaver study
    • Svendsen, O., Hassager, C., Skodt, V., and Christiansen, C. Impact of soft tissue on in vivo accuracy of bone numeral measurements in the spine, hip and forearm: A human cadaver study. J Bone Miner Res 10:860-873; 1995.
    • (1995) J Bone Miner Res , vol.10 , pp. 860-873
    • Svendsen, O.1    Hassager, C.2    Skodt, V.3    Christiansen, C.4
  • 23
    • 0019151527 scopus 로고
    • Age changes in bone mineralization, cortical thickness and aversian canal area
    • Thompson, D. Age changes in bone mineralization, cortical thickness and aversian canal area. Calcif Tissue Int 31:5-11; 1980.
    • (1980) Calcif Tissue Int , vol.31 , pp. 5-11
    • Thompson, D.1
  • 24
    • 0024505667 scopus 로고
    • Methods of bone mineral measurement
    • Tothill, P. Methods of bone mineral measurement. Phys Med Biol 34:543-572; 1989.
    • (1989) Phys Med Biol , vol.34 , pp. 543-572
    • Tothill, P.1
  • 25
    • 84908835918 scopus 로고
    • De bepaling van sporenelementen in biologisch materiaal door neutron activeringsanalyse. Verhandelingen van de koninklijke vlaamse academie voor wetenschappen
    • Brussels
    • Van Den Winkel, P. De bepaling van sporenelementen in biologisch materiaal door neutron activeringsanalyse. Verhandelingen van de Koninklijke Vlaamse Academie voor Wetenschappen, Letteren en Schone Kunsten van België, Klasse der Wetenschappen, Jaargang XXXII, No. 114, Brussels; 1970.
    • (1970) Letteren en Schone Kunsten van België, Klasse der Wetenschappen, Jaargang , vol.32 , Issue.114
    • Van Den Winkel, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.