Accuracy and precision study in vitro for peripheral quantitative computed tomography

Author keywords

Accuracy; Ash weight; Bone mineral measurement; Peripheral quantitative computed tomography (pQCT); Precision; Radius

Indexed keywords

ACCURACY; ARTICLE; BONE DENSITY; BONE MINERAL; CADAVER; COMPUTER ASSISTED TOMOGRAPHY; FOREARM; HUMAN; HUMAN TISSUE; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; TRABECULAR BONE;

EID: 0029953581     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF01622736     Document Type: Article
Times cited : (57)

References (20)
  • 1
    • 0026047329 scopus 로고
    • An evaluation of forearm bone mineral measurement with dual-energy x-ray absorptiometry
    • Larcos G, Wahner HW. An evaluation of forearm bone mineral measurement with dual-energy x-ray absorptiometry. J Nucl Med 1991;32:2101-6.
    • (1991) J Nucl Med , vol.32 , pp. 2101-2106
    • Larcos, G.1    Wahner, H.W.2
  • 2
    • 0026350549 scopus 로고
    • Dual-energy x-ray absorptiometry versus single photon absorptiometry of the radius
    • Weinstein RS, New KD, Sappington LJ. Dual-energy x-ray absorptiometry versus single photon absorptiometry of the radius. Calcif tissue Int 1991;49:313-6.
    • (1991) Calcif Tissue Int , vol.49 , pp. 313-316
    • Weinstein, R.S.1    New, K.D.2    Sappington, L.J.3
  • 3
    • 0026735628 scopus 로고
    • Comparison of single-photon and dual-energy x-ray absorptiometry of the radius
    • Nelson D, Feingold M, Mascha E, Kleerekoper M. Comparison of single-photon and dual-energy x-ray absorptiometry of the radius. Bone Miner 1992;18:77-83.
    • (1992) Bone Miner , vol.18 , pp. 77-83
    • Nelson, D.1    Feingold, M.2    Mascha, E.3    Kleerekoper, M.4
  • 4
    • 0027104417 scopus 로고
    • Comparative assessment of bone mineral density of the forearm using single photon and dual x-ray absorptiometry
    • Nieves JW, Cosman F, Mars C, Lindsay R. Comparative assessment of bone mineral density of the forearm using single photon and dual x-ray absorptiometry. Calcif Tissue Int 1992;51:352-5.
    • (1992) Calcif Tissue Int , vol.51 , pp. 352-355
    • Nieves, J.W.1    Cosman, F.2    Mars, C.3    Lindsay, R.4
  • 5
    • 0026636091 scopus 로고
    • Dual-energy x-ray absorptiometry of the forearm: Reproducibility and correlation with single-photon absorptiometry
    • Leboff MS, Fuleihan GE, Angell JE, Chung S, Curtis K. Dual-energy x-ray absorptiometry of the forearm: reproducibility and correlation with single-photon absorptiometry. J Bone Miner Res 1992;7:841-6.
    • (1992) J Bone Miner Res , vol.7 , pp. 841-846
    • Leboff, M.S.1    Fuleihan, G.E.2    Angell, J.E.3    Chung, S.4    Curtis, K.5
  • 7
    • 0028294325 scopus 로고
    • Single x-ray absorptiometry of the forearm: Precision, correlation, and reference data
    • Kelly TL, Crane G, Baran DT. Single x-ray absorptiometry of the forearm: precision, correlation, and reference data. Calcif Tissue Int 1994;54:212-8.
    • (1994) Calcif Tissue Int , vol.54 , pp. 212-218
    • Kelly, T.L.1    Crane, G.2    Baran, D.T.3
  • 9
    • 0024274412 scopus 로고
    • Quantitative computed tomography at peripheral measuring sites
    • Rüegsegger P. Quantitative computed tomography at peripheral measuring sites. Ann Chir Gynaecol 1988;77:204-7.
    • (1988) Ann Chir Gynaecol , vol.77 , pp. 204-207
    • Rüegsegger, P.1
  • 10
    • 0024312025 scopus 로고
    • Peripheral QCT: A lowrisk procedure to identify women predisposed to osteoporosis
    • Müller A, Rüegsegger E, Rüegsegger P. Peripheral QCT: a lowrisk procedure to identify women predisposed to osteoporosis. Phys Med Biol 1989;34:741-9.
    • (1989) Phys Med Biol , vol.34 , pp. 741-749
    • Müller, A.1    Rüegsegger, E.2    Rüegsegger, P.3
  • 11
    • 0026118810 scopus 로고
    • Peripheral quantitative computed tomography for bone mineral measurement with a new special purpose QCT-scanner: Method, normal references, comparison to osteoporotic patients
    • Schneider P, Börner W. Peripheral quantitative computed tomography for bone mineral measurement with a new special purpose QCT-scanner: method, normal references, comparison to osteoporotic patients. Fortschr Rontgenstr 1991;154:292-9.
    • (1991) Fortschr Rontgenstr , vol.154 , pp. 292-299
    • Schneider, P.1    Börner, W.2
  • 12
    • 0023552633 scopus 로고
    • Performance evaluation of density measurements of axial and peripheral bone with x-ray and gamma-ray computed tomography
    • Hangartner TN, Battista JJ, Overton TR. Performance evaluation of density measurements of axial and peripheral bone with x-ray and gamma-ray computed tomography. Phys Med Biol 1987:32:1393-406.
    • (1987) Phys Med Biol , vol.32 , pp. 1393-1406
    • Hangartner, T.N.1    Battista, J.J.2    Overton, T.R.3
  • 13
    • 0026102650 scopus 로고
    • Localization of regional forearm bone loss from high resolution computed tomographic images
    • Rüegsegger P, Durand E, Dambacher MA. Localization of regional forearm bone loss from high resolution computed tomographic images. Osteoporosis Int 1991;1:76-80.
    • (1991) Osteoporosis Int , vol.1 , pp. 76-80
    • Rüegsegger, P.1    Durand, E.2    Dambacher, M.A.3
  • 14
    • 0028587259 scopus 로고
    • European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: Assessment of precision, accuracy and stability
    • Pearson J, Ruegsegger P, Dequeker J, et al. European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision, accuracy and stability. Bone Miner 1994:27:109-20.
    • (1994) Bone Miner , vol.27 , pp. 109-120
    • Pearson, J.1    Ruegsegger, P.2    Dequeker, J.3
  • 15
    • 0023851634 scopus 로고
    • Vertebral mineral determination by quantitative computed tomography (QCT): Accuracy of single and dual energy measurements
    • Glüer CC, Reiser UJ, Davis CA, Rutt BK, Genant HK. Vertebral mineral determination by quantitative computed tomography (QCT): accuracy of single and dual energy measurements. J Comput Assist Tomogr 1988;12:242-58.
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 242-258
    • Glüer, C.C.1    Reiser, U.J.2    Davis, C.A.3    Rutt, B.K.4    Genant, H.K.5
  • 16
    • 0028001373 scopus 로고
    • Dual x-ray absorptiometry forearm software: Accuracy and intermachine relationship
    • Hagiwara S, Engelke K, Yang S-O, et al. Dual x-ray absorptiometry forearm software: accuracy and intermachine relationship. J Bone Miner Res 1994;9:1425-7.
    • (1994) J Bone Miner Res , vol.9 , pp. 1425-1427
    • Hagiwara, S.1    Engelke, K.2    Yang, S.-O.3
  • 17
    • 0026576867 scopus 로고
    • Reproducibility of bone density measurements of the distal radius using a high resolution special scanner for peripheral quantitative computed tomography (sinsle energy pQCT)
    • Lehmann R, Wapniarz M, Kvasnicka HM, Baedeker S, Klein K, Allolio B. Reproducibility of bone density measurements of the distal radius using a high resolution special scanner for peripheral quantitative computed tomography (sinsle energy pQCT). Radiologe 1992;32:177-81.
    • (1992) Radiologe , vol.32 , pp. 177-181
    • Lehmann, R.1    Wapniarz, M.2    Kvasnicka, H.M.3    Baedeker, S.4    Klein, K.5    Allolio, B.6
  • 18
    • 0028310322 scopus 로고
    • Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population
    • Burtz S, Wüster C, Scheidt-Nave C, Götz M, Ziegler R. Forearm BMD as measured by peripheral quantitative computed tomography (pQCT) in a German reference population. Osteoporosis Int 1994;4:179-84.
    • (1994) Osteoporosis Int , vol.4 , pp. 179-184
    • Burtz, S.1    Wüster, C.2    Scheidt-Nave, C.3    Götz, M.4    Ziegler, R.5
  • 19
    • 0029131195 scopus 로고
    • Assessment of the skeletal status by peripheral quantitative computed tomography: Short-term precision in-vivo and comparison to dual x-ray absorptiometry
    • Grampp S, Lang P, Jergas M, et al. Assessment of the skeletal status by peripheral quantitative computed tomography: short-term precision in-vivo and comparison to dual x-ray absorptiometry. J Bone Miner Res 1995;10:1566-76.
    • (1995) J Bone Miner Res , vol.10 , pp. 1566-1576
    • Grampp, S.1    Lang, P.2    Jergas, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.