-
1
-
-
0036033208
-
Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium
-
Yorker J.G.,Jeromin L. S.,Lee D.L.Y,Palecki E.F.,Golden K.P.and Jing, Z.,"Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium," SPIE 4682, 21-29 (2002).
-
(2002)
SPIE
, vol.4682
, pp. 21-29
-
-
Yorker, J.G.1
Jeromin, L.S.2
Lee, D.L.Y.3
Palecki, E.F.4
Golden, K.P.5
Jing, Z.6
-
2
-
-
0041374313
-
Performance of advanced a-Si/CsIbased flat panel x-ray detectors for mammography
-
Albagli, D., Hudspeth, H., Possin, G., Lee, J., Granfors, P. and Giambattista, B. "Performance of advanced a-Si/CsIbased flat panel x-ray detectors for mammography," SPIE 5030, 553-563 (2003).
-
(2003)
SPIE
, vol.5030
, pp. 553-563
-
-
Albagli, D.1
Hudspeth, H.2
Possin, G.3
Lee, J.4
Granfors, P.5
Giambattista, B.6
-
3
-
-
66849110292
-
Computed radiography systems for mammography.fuji FCR 5000 mA and FCR profect CS. a technical report
-
Lawinski, C., Mackenzie, A., Cole, H., Blake, P. and Honey, I., "Computed Radiography Systems for Mammography. Fuji FCR 5000 mA and FCR Profect CS. A Technical Report," MHRA Report 04094, (2004).
-
(2004)
MHRA Report 04094
-
-
Lawinski, C.1
Mackenzie, A.2
Cole, H.3
Blake, P.4
Honey, I.5
-
4
-
-
0002050483
-
Applied linear-systems theory
-
in Physics and Psychophysics, Handbook of Medical Imaging Vol. 1, edited by J. Beutel, H. Kundel, and R. L. Van Metter
-
Cunningham, I. A., "Applied Linear-Systems Theory", in Physics and Psychophysics, Handbook of Medical Imaging Vol. 1, edited by J. Beutel, H. Kundel, and R. L. Van Metter, SPIE, Bellingham, WA, 79-159 (2000).
-
(2000)
SPIE, Bellingham,WA
, vol.1
, pp. 79-159
-
-
Cunningham, I.A.1
-
5
-
-
0034874464
-
Investigation of imaging performance of asmorphous selenium flat-panel dtectors for digital mammography
-
Zhao, W., Ji, W. G., Rowlands, J. A. and Debrie, A.,"Investigation of Imaging Performance of Amorphous Selenium Flat-Panel Detectors For Digital Mammography," Proc. SPIE 4320, 536-546 (2001).
-
(2001)
Proc.SPIE
, vol.4320
, pp. 536-546
-
-
Zhao, W.1
Ji, W.G.2
Rowlands, J.A.3
Debrie, A.4
-
6
-
-
0036145048
-
A comparison of the imaging properties of CCD-based devices used for small field digital mammography
-
Evans, D. S., Workman, A. and Payne, M, quot;A comparison of the imaging properties of CCD-based devices used for small field digital mammography,quot; Phys. Med. Biol. 47, 117-135 (2002).
-
(2002)
Phys.Med. Biol.
, vol.47
, pp. 117-135
-
-
Evans, D.S.1
Workman, A.2
Payne, M.3
-
7
-
-
31844442646
-
A new CMOS-based digital imaging detector for applications in mammography
-
Baysal, M. A., Toker, E., "A new CMOS-based digital imaging detector for applications in mammography," Proc. SPIE 5923, 59230G-1 (2005).
-
(2005)
Proc. SPIE
, vol.5923
-
-
Baysal, M.A.1
Toker, E.2
-
8
-
-
9244230065
-
Lubberts effect in columnar phosphors
-
Badano, A., Gagne, R. M., Gallas, B.D., Jennings, R. J., Boswell, J. S. and Myers, K. J., "Lubberts effect in columnar phosphors," Med. Phys. 31, 3122-3131 (2004).
-
(2004)
Med.Phys.
, vol.31
, pp. 3122-3131
-
-
Badano, A.1
Gagne, R.M.2
Gallas, B.D.3
Jennings, R.J.4
Boswell, J.S.5
Myers, K.J.6
-
9
-
-
33749396880
-
Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors
-
Hajdok, G., Yao, J., Battista, J. J. and Cunningham, I. A., "Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors," Med. Phys. 33, 3601-3620 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 3601-3620
-
-
Hajdok, G.1
Yao, J.2
Battista, J.J.3
Cunningham, I.A.4
-
10
-
-
33845964617
-
Performance of a high fill factor,indirect detection prototype flat-panel imager for mammography
-
El-Mohri, Y., Antonuk, L. E., Zhao, Q., Wang, Y., Li, Y., Du, H. and Sawant, A.,"Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography," Med. Phys. 34, 315-327 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 315-327
-
-
El-Mohri, Y.1
Antonuk, L.E.2
Zhao, Q.3
Wang, Y.4
Li, Y.5
Du, H.6
Sawant, A.7
-
11
-
-
0000194699
-
Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays
-
Mulato, M., Lu, J. P. and Street, R. A., aquot;Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays,aquot; J. Appl. Phys. 89, 638-647 (2001).
-
(2001)
J.Appl. Phys.
, vol.89
, pp. 638-647
-
-
Mulato, M.1
Lu, J.P.2
Street, R.A.3
-
12
-
-
23844474189
-
Investigation of strategies to achieve optimal DQE performance from indirect detection, active matrix flat-panel imagers through novel pixel amplification architectures
-
Antonuk, L. E., Li, Y., Du, H., El-Mohri, Y., Zhao, Q., Yamamoto, J., Sawant, A., Wang. Y., Su, Z., Lu, J. P., Street, R. A., Weisfield, R. and Yao, B.,"Investigation of Strategies to achieve optimal DQE performance from Indirect detection, Active matrix flat-panel imagers through novel pixel amplification architectures," Proc. SPIE 5745, 18-31 (2005).
-
(2005)
Proc. SPIE
, vol.5745
, pp. 18-31
-
-
Antonuk, L.E.1
Li, Y.2
Du, H.3
El-Mohri, Y.4
Zhao, Q.5
Yamamoto, J.6
Sawant, A.7
Wang, Y.8
Su, Z.9
Lu, J.P.10
Street, R.A.11
Weisfield, R.12
Yao, B.13
-
13
-
-
33847645786
-
A comparison of the performance of digital mammography systems
-
Monnin, P., Gutierrez, D., Bulling, S., Guntern, D. and Verdun, F. R.,"A comparison of the performance of digital mammography systems," Med. Phys. 34, 315-327 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 315-327
-
-
Monnin, P.1
Gutierrez, D.2
Bulling, S.3
Guntern, D.4
Verdun, F.R.5
-
14
-
-
66849133564
-
-
in Computed radiography, editied by Tateno, Y.Iinuma, T.and Takano M, Springer-Verlag, Tokyo,chap.
-
Kato, H., "Image reading: conversion to digital signals," in Computed radiography, editied by Tateno, Y., Iinuma, T. and Takano, M., Springer-Verlag, Tokyo, chap. 3 (1987).
-
(1987)
Image reading:conversion to digital signals
, vol.3
-
-
Kato, H.1
-
15
-
-
0018007682
-
A method of electronic readout of electrophotographic and electroradiographic images
-
Korn, D. M., Johnson, S. P., Nelson, O. L. and Ziegler, R. J., "A method of electronic readout of electrophotographic and electroradiographic images,"J. Appl. Photo. Eng. 4, 178-182 (1978).
-
(1978)
J.Appl. Photo. Eng.
, vol.4
, pp. 178-182
-
-
Korn, D.M.1
Johnson, S.P.2
Nelson, O.L.3
Ziegler, R.J.4
-
16
-
-
0020885540
-
-
J.Non-Cryst. Solids 59&60
-
Kempter, K., Kiendl, A., Müller, W. and Volt, H., "Charge trapping in a multilayer ELIC device," J. Non-Cryst. Solids 59&60, 1219-1222 (1983).
-
(1983)
Charge trapping in a multilayer ELIC device
, pp. 1219-1222
-
-
Kempter, K.1
Kiendl, A.2
Müller, W.3
Volt, H.4
-
17
-
-
0024549833
-
A new photoconductor imaging system for digital radiography
-
De Monts, H. and Beaumont, F., "A new photoconductor imaging system for digital radiography," Med. Phys. 16, 105-109 (1989).
-
(1989)
Med. Phys.
, vol.16
, pp. 105-109
-
-
De Monts, H.1
Beaumont, F.2
-
18
-
-
0028802332
-
X-ray imaging using amorphous selenium: Photoinduced discharge (PID) readout for digital general radiography
-
Rowlands, J. A. and Hunter, D. M.,"X-ray imaging using amorphous selenium: Photoinduced discharge (PID) readout for digital general radiography," Med. Phys. 22, 1983-1996 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 1983-1996
-
-
Rowlands, J.A.1
Hunter, D.M.2
-
19
-
-
40049084048
-
Digital radiography using amorphous selenium:Photoconductively activated switch (PAS) readout system
-
Reznik, N., Komljenovic, P. T., Germann, S. and Rowlands, J. A.,"Digital radiography using amorphous selenium: Photoconductively activated switch (PAS) readout system," Med. Phys. 35, 1039-1050 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 1039-1050
-
-
Reznik, N.1
Komljenovic, P.T.2
Germann, S.3
Rowlands, J.A.4
-
20
-
-
0038151339
-
Electronic states in vitreous selenium
-
Hartke, J. L., Regensburger, P. J.,"Electronic states in vitreous Selenium," Phys. Rev. 139, A970-A980 (1965).
-
(1965)
Phys. Rev.
, vol.139
-
-
Hartke, J.L.1
Regensburger, P.J.2
|