메뉴 건너뛰기




Volumn 19, Issue 12, 2008, Pages

Difficulties in fitting the thermal response of atomic force microscope cantilevers for stiffness calibration

Author keywords

Atomic force microscopy; Cantilever calibration; Thermal response

Indexed keywords

AIR; ATOMIC FORCE MICROSCOPY; CALIBRATION; FLUID STRUCTURE INTERACTION; LOADS (FORCES); NANOCANTILEVERS; NATURAL FREQUENCIES; STIFFNESS;

EID: 64549131221     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/19/12/125101     Document Type: Article
Times cited : (10)

References (31)
  • 1
    • 27744587245 scopus 로고    scopus 로고
    • Force measurements with the atomic force microscope: Technique, interpretation and applications
    • Butt H-J, Cappella B and Kappl M 2005 Force measurements with the atomic force microscope: technique, interpretation and applications Surf. Sci. Rep. 59 1-152
    • (2005) Surf. Sci. Rep. , vol.59 , Issue.1-6 , pp. 1-152
    • Butt, H.-J.1    Cappella, B.2    Kappl, M.3
  • 2
    • 33947207859 scopus 로고    scopus 로고
    • Atomic force microscopy: Determination of unbinding force, off rate and energy barrier for protein-ligand interaction
    • Lee C K, Wang Y M, Huang L S and Lin S M 2007 Atomic force microscopy: determination of unbinding force, off rate and energy barrier for protein-ligand interaction Micron 38 446-61
    • (2007) Micron , vol.38 , Issue.5 , pp. 446-461
    • Lee, C.K.1    Wang, Y.M.2    Huang, L.S.3    Lin, S.M.4
  • 3
    • 22644436147 scopus 로고    scopus 로고
    • Application of atomic force spectroscopy (afs) to studies of adhesion phenomena: A review
    • Leite F L and Herrmann P S P 2005 Application of atomic force spectroscopy (afs) to studies of adhesion phenomena: a review J. Adhes. Sci. Technol. 19 365-405
    • (2005) J. Adhes. Sci. Technol. , vol.19 , Issue.3 , pp. 365-405
    • Leite, F.L.1    Herrmann, P.S.P.2
  • 4
    • 33750913515 scopus 로고    scopus 로고
    • Chemical force microscopy of chemical and biological interactions
    • Noy A 2006 Chemical force microscopy of chemical and biological interactions Surf. Interface Anal. 38 1429-41
    • (2006) Surf. Interface Anal. , vol.38 , Issue.11 , pp. 1429-1441
    • Noy, A.1
  • 5
    • 0037328523 scopus 로고    scopus 로고
    • Quantitative characterization of biomolecular assemblies and interactions using atomic force microscopy
    • Yang Y, Wang H and Erie D A 2003 Quantitative characterization of biomolecular assemblies and interactions using atomic force microscopy Methods 29 175-87
    • (2003) Methods , vol.29 , Issue.2 , pp. 175-187
    • Yang Wang Y, H.1    Erie, D.A.2
  • 7
    • 0030234766 scopus 로고    scopus 로고
    • Determination of the spring constants of probes for force microscopy/spectroscopy
    • Gibson C T, Watson G S and Myhra S 1996 Determination of the spring constants of probes for force microscopy/spectroscopy Nanotechnology 7 259-62
    • (1996) Nanotechnology , vol.7 , Issue.3 , pp. 259-262
    • Gibson Watson T C, G.S.1    Myhra, S.2
  • 8
    • 0041864075 scopus 로고    scopus 로고
    • Accurate force measurement in the atomic force microscope: A microfabricated array of reference springs for easy cantilever calibration
    • Cumpson P J, Hedley J and Zhdan P 2003 Accurate force measurement in the atomic force microscope: a microfabricated array of reference springs for easy cantilever calibration Nanotechnology 14 918
    • (2003) Nanotechnology , vol.14 , Issue.8 , pp. 918
    • Cumpson Hedley J P, J.1    Zhdan, P.2
  • 9
    • 0036609560 scopus 로고    scopus 로고
    • Device for the determination of spring constants of atomic force microscope cantilevers and micromachined springs
    • Jerico S K and Jerico M H 2002 Device for the determination of spring constants of atomic force microscope cantilevers and micromachined springs Rev. Sci. Instrum. 73 2483
    • (2002) Rev. Sci. Instrum. , vol.73 , Issue.6 , pp. 2483
    • Jerico, S.K.1    Jerico, M.H.2
  • 10
    • 0028422252 scopus 로고
    • Experimental determination of spring constants in atomic force microscopy
    • Senden T J and Ducker W 1994 Experimental determination of spring constants in atomic force microscopy Langmuir 10 1003-4
    • (1994) Langmuir , vol.10 , Issue.4 , pp. 1003-1004
    • Senden, T.J.1    Ducker, W.2
  • 11
    • 0027540056 scopus 로고
    • A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy
    • Cleveland J P, Manne S, Bocek D and Hansma P K 1993 A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy Rev. Sci. Instrum. 64 403-5
    • (1993) Rev. Sci. Instrum. , vol.64 , Issue.2 , pp. 403-405
    • Cleveland Manne Bocek S P J, D.1    Hansma, P.K.2
  • 12
    • 36449007442 scopus 로고
    • Calibration of atomic-force microscope tips
    • Hutter J L and Bechhoefer J 1993 Calibration of atomic-force microscope tips Rev. Sci. Instrum. 64 1868-73
    • (1993) Rev. Sci. Instrum. , vol.64 , Issue.7 , pp. 1868-1873
    • Hutter, J.L.1    Bechhoefer, J.2
  • 13
    • 36449002856 scopus 로고
    • Method for the calibration of atomic force microcope cantilevers
    • Sader J E, Larson I, Mulvaney P and White L R 1995 Method for the calibration of atomic force microcope cantilevers Rev. Sci. Instrum. 66 3789-98
    • (1995) Rev. Sci. Instrum. , vol.66 , Issue.7 , pp. 3789-3798
    • Sader Larson Mulvaney I E J, P.1    White, L.R.2
  • 14
    • 34347209835 scopus 로고
    • Calculation of thermal noise in atomic force microscopy
    • Butt H-J and Jaschke M 1995 Calculation of thermal noise in atomic force microscopy Nanotechnology 6 1-7
    • (1995) Nanotechnology , vol.6 , Issue.1 , pp. 1-7
    • Butt, H.-J.1    Jaschke, M.2
  • 16
    • 4544257551 scopus 로고    scopus 로고
    • Finite optical spot size and position corrections in thermal spring constant calibration
    • Proksch R, Schäffer T E, Cleveland J P, Callahan R C and Viani M B 2004 Finite optical spot size and position corrections in thermal spring constant calibration Nanotechnology 15 1344-50
    • (2004) Nanotechnology , vol.15 , Issue.9 , pp. 1344-1350
    • Proksch Schäffer Cleveland Callahan P J E T R, R.C.1    Viani, M.B.2
  • 17
    • 33646192726 scopus 로고    scopus 로고
    • Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants
    • Cook S M, Schäffer T E, Chyoweth K M, Wigton M, Simmonds R W and Lang K M 2006 Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants Nanotechnology 17 2135-45
    • (2006) Nanotechnology , vol.17 , Issue.9 , pp. 2135-2145
    • Cook Schäffer Chyoweth Wigton Simmonds M M K E T M S, R.W.1    Lang, K.M.2
  • 18
    • 0032109073 scopus 로고    scopus 로고
    • Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
    • Sader J E 1998 Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope J. Appl. Phys. 84 64-76
    • (1998) J. Appl. Phys. , vol.84 , Issue.1 , pp. 64-76
    • Sader, J.E.1
  • 19
    • 0001550969 scopus 로고    scopus 로고
    • Multi-mode noise analysis of cantilevers for scanning probe microscopy
    • Salapaka M V, Bergh H S, Lai J, Majumar A and McFarland E 1997 Multi-mode noise analysis of cantilevers for scanning probe microscopy J. Appl. Phys. 81 2480-7
    • (1997) J. Appl. Phys. , vol.81 , Issue.6 , pp. 2480-2487
    • Salapaka Bergh Lai Majumar J S H V M, A.1    McFarland, E.2
  • 20
    • 0001155528 scopus 로고    scopus 로고
    • Calibration of rectangular atomic force microscope cantilevers
    • Sader J E, Chon J W M and Mulvaney P 1999 Calibration of rectangular atomic force microscope cantilevers Rev. Sci. Instrum. 70 3967-9
    • (1999) Rev. Sci. Instrum. , vol.70 , Issue.10 , pp. 3967-3969
    • Sader Chon E J, J.W.M.1    Mulvaney, P.2
  • 21
    • 33847122886 scopus 로고    scopus 로고
    • Fluid-structure interaction in atomic force microscope cantilever dynamics and thermal response
    • Cole D G and Clark R L 2007 Fluid-structure interaction in atomic force microscope cantilever dynamics and thermal response J. Appl. Phys. 101 034303
    • (2007) J. Appl. Phys. , vol.101 , Issue.3 , pp. 034303
    • Cole, D.G.1    Clark, R.L.2
  • 23
    • 33845810247 scopus 로고    scopus 로고
    • The stochastic dynamics of micron and nanoscale elastic cantilevers in fluid: Fluctuations from dissipation
    • Paul M R, Clark M T and Cross M C 2006 The stochastic dynamics of micron and nanoscale elastic cantilevers in fluid: fluctuations from dissipation Nanotechnology 17 4502-13
    • (2006) Nanotechnology , vol.17 , Issue.17 , pp. 4502-4513
    • Paul Clark R M, M.T.1    Cross, M.C.2
  • 24
    • 0024861573 scopus 로고
    • A bisection method for computing the norm of a transfer matrix and related problems
    • Boyd S P, Balakrishnan V and Kabamba P 1989 A bisection method for computing the norm of a transfer matrix and related problems Math. Control Signals Syst. 2 207-19
    • (1989) Math. Control Signals Syst. , vol.2 , Issue.3 , pp. 207-219
    • Boyd Balakrishnan P S, V.1    Kabamba, P.2
  • 25
    • 0011991339 scopus 로고
    • Calculation of unsteady flows due to small motions of cylinders in a viscous fluid
    • Tuck E O 1969 Calculation of unsteady flows due to small motions of cylinders in a viscous fluid J. Eng. Math. 3 29-44
    • (1969) J. Eng. Math. , vol.3 , Issue.1 , pp. 29-44
    • Tuck, E.O.1
  • 29
    • 0000892453 scopus 로고    scopus 로고
    • Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids
    • Chon J W M, Mulvaney P and Sader J E 2000 Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids J. Appl. Phys. 87 3978-88
    • (2000) J. Appl. Phys. , vol.87 , Issue.8 , pp. 3978-3988
    • Chon Mulvaney M W J, P.1    Sader, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.