메뉴 건너뛰기




Volumn 223, Issue 1, 2009, Pages 27-44

Stress shielding and stress concentration of contemporary epiphyseal hip prostheses

Author keywords

Embedded strain gauges; Epiphyseal hip prostheses; Femoral head resurfacing; In vitro bone testing; Load transfer; Physiologicalloading; Proximal femur; Stress concentration; Stress shielding

Indexed keywords

EMBEDDED STRAIN GAUGES; EPIPHYSEAL HIP PROSTHESES; FEMORAL HEAD RESURFACING; IN-VITRO BONE TESTING; LOAD TRANSFER; PHYSIOLOGICALLOADING; PROXIMAL FEMUR; STRESS SHIELDING; FEMORAL HEADS; IN-VITRO; PHYSIOLOGICAL LOADINGS;

EID: 63849152664     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM470     Document Type: Article
Times cited : (24)

References (63)
  • 1
    • 50549156477 scopus 로고
    • Arthroplasty of the hip: A new operation
    • Charnley, J. C. Arthroplasty of the hip: a new operation. Lancet, 1961, 1, 1129-1132.
    • (1961) Lancet , vol.1 , pp. 1129-1132
    • Charnley, J.C.1
  • 2
    • 0019512834 scopus 로고
    • Wagner surface replacement arthroplasty of the hip. Analysis of fourteen failures in forty-one hips
    • Head, W. C. Wagner surface replacement arthroplasty of the hip. Analysis of fourteen failures in forty-one hips. J. Bone Jt Surg. Am., 1981, 63(3),420-427.
    • (1981) J. Bone Jt Surg. Am , vol.63 , Issue.3 , pp. 420-427
    • Head, W.C.1
  • 3
    • 0020607610 scopus 로고
    • ICLH surface replacement of the hip. An analysis of the first 10 years
    • Freeman, M. A. and Bradley, G. W. ICLH surface replacement of the hip. An analysis of the first 10 years. J. Bone Jt Surg. Br., 1983, 65(4), 405-411.
    • (1983) J. Bone Jt Surg. Br , vol.65 , Issue.4 , pp. 405-411
    • Freeman, M.A.1    Bradley, G.W.2
  • 4
    • 0023029397 scopus 로고
    • THARIES resurfacing arthroplasty. Evolution and long-term results
    • Amstutz, H. C., Dorey, F., and O'Carroll, P. F. THARIES resurfacing arthroplasty. Evolution and long-term results. Clin. Orthop. Related Res., 1986, 213, 92-114.
    • (1986) Clin. Orthop. Related Res , vol.213 , pp. 92-114
    • Amstutz, H.C.1    Dorey, F.2    O'Carroll, P.F.3
  • 6
    • 0026603288 scopus 로고
    • Lessons learned in 30 years of total hip arthroplasty
    • Coventry, M. B. Lessons learned in 30 years of total hip arthroplasty. Clin. Orthop. Related Res., 1992, 274, 22-29.
    • (1992) Clin. Orthop. Related Res , vol.274 , pp. 22-29
    • Coventry, M.B.1
  • 7
    • 65249138305 scopus 로고    scopus 로고
    • Consensus statement on total hip joint replacement. NIH Consensus Statement 12(5), US Department of Health and Human Services, National Institutes of Health, 12-14 September 1994, pp. 1-31.
    • Consensus statement on total hip joint replacement. NIH Consensus Statement 12(5), US Department of Health and Human Services, National Institutes of Health, 12-14 September 1994, pp. 1-31.
  • 8
    • 0021798037 scopus 로고
    • Comportement mécanique de l'épiphyse supérieure de fémur resurfacé et incidence des variations anatomiques et des différentes types de cupules.
    • Crick, D., Wagner, J., Bourgois, R., and Dehu, P. Comportement mécanique de l'épiphyse supérieure de fémur resurfacé et incidence des variations anatomiques et des différentes types de cupules. Acta Orthopaedica Belgica, 1985, 51, 168-178.
    • (1985) Acta Orthopaedica Belgica , vol.51 , pp. 168-178
    • Crick, D.1    Wagner, J.2    Bourgois, R.3    Dehu, P.4
  • 9
    • 0022342496 scopus 로고
    • Interface stresses in the resurfaced hip. Finite element analysis of load transmission in the femoral head
    • Huiskes, R., Strens, P. H. G. E., van Heck, J., and Slooff, T. J. J. H. Interface stresses in the resurfaced hip. Finite element analysis of load transmission in the femoral head. Acta Orthopaedica Scandinavica, 1985, 56, 474-478.
    • (1985) Acta Orthopaedica Scandinavica , vol.56 , pp. 474-478
    • Huiskes, R.1    Strens, P.H.G.E.2    van Heck, J.3    Slooff, T.J.J.H.4
  • 10
    • 0021348858 scopus 로고
    • Total articular resurfacing arthroplasty. Analysis of component failure in sixty-seven hips
    • Head, W. C. Total articular resurfacing arthroplasty. Analysis of component failure in sixty-seven hips. J. Bone Jt Surg. Am., 1984, 66(1), 28-34.
    • (1984) J. Bone Jt Surg. Am , vol.66 , Issue.1 , pp. 28-34
    • Head, W.C.1
  • 11
    • 33645218204 scopus 로고    scopus 로고
    • McMinn, D. and Daniel, J. History and modern concepts in surface replacement. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 239-251.
    • McMinn, D. and Daniel, J. History and modern concepts in surface replacement. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 239-251.
  • 13
    • 15044348747 scopus 로고    scopus 로고
    • Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips
    • Back, D. L., Dalziel, R., Young, D., and Shimmin, A. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J. Bone Jt Surg. Br., 2005, 87(3),324-329.
    • (2005) J. Bone Jt Surg. Br , vol.87 , Issue.3 , pp. 324-329
    • Back, D.L.1    Dalziel, R.2    Young, D.3    Shimmin, A.4
  • 14
    • 17044401726 scopus 로고    scopus 로고
    • Complications associated with hip resurfacing arthroplasty
    • Shimmin, A. J., Bare, J., and Back, D. L. Complications associated with hip resurfacing arthroplasty. Orthop. Clin. N. Am., 2005, 36, 187-193.
    • (2005) Orthop. Clin. N. Am , vol.36 , pp. 187-193
    • Shimmin, A.J.1    Bare, J.2    Back, D.L.3
  • 16
    • 33645243057 scopus 로고    scopus 로고
    • Grigoris, P., Roberts, P., Panousis, K., and Jin, Z. Hip resurfacing arthroplasty: the evolution of contemporary designs. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 95-105.
    • Grigoris, P., Roberts, P., Panousis, K., and Jin, Z. Hip resurfacing arthroplasty: the evolution of contemporary designs. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 95-105.
  • 17
    • 38949174234 scopus 로고    scopus 로고
    • Birmingham hip resurfacing arthroplasty: Short-term clinical and radiographic outcome
    • Witzleb, W. C., Arnold, M., Krummenauer, F., Knecht, A., Ranisch, H., and Gunther, K. P. Birmingham hip resurfacing arthroplasty: short-term clinical and radiographic outcome. Eur. J. Med. Res., 2008, 13(1), 39-46.
    • (2008) Eur. J. Med. Res , vol.13 , Issue.1 , pp. 39-46
    • Witzleb, W.C.1    Arnold, M.2    Krummenauer, F.3    Knecht, A.4    Ranisch, H.5    Gunther, K.P.6
  • 18
    • 65249111113 scopus 로고    scopus 로고
    • Murray, D.W., Little, J. P., Steffan, R., Fouget, P., S., K., Gundle, R., and McLardy-Smith, P. Femoral neck fractures following resurfacing. In Proceedings of the IMechE Conference on Engineers and surgeons: joined at the hip, London, UK, 2007, pp. 137-139 (Professional Engineering Publishing, London).
    • Murray, D.W., Little, J. P., Steffan, R., Fouget, P., S., K., Gundle, R., and McLardy-Smith, P. Femoral neck fractures following resurfacing. In Proceedings of the IMechE Conference on Engineers and surgeons: joined at the hip, London, UK, 2007, pp. 137-139 (Professional Engineering Publishing, London).
  • 19
    • 85047691712 scopus 로고    scopus 로고
    • Taylor, M. Finite element analysis of the resurfaced femoral head. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 289-297.
    • Taylor, M. Finite element analysis of the resurfaced femoral head. Proc. IMechE, Part H: J. Engineering in Medicine, 2006, 220(2), 289-297.
  • 21
    • 0025161210 scopus 로고
    • Post-loosening mechanical behavior of femoral resurfacing prostheses
    • Huiskes, R., Strens, P., Vroemen, W., and Slooff, T. J. Post-loosening mechanical behavior of femoral resurfacing prostheses. Clin. Mater., 1990, 6(1), 37-55.
    • (1990) Clin. Mater , vol.6 , Issue.1 , pp. 37-55
    • Huiskes, R.1    Strens, P.2    Vroemen, W.3    Slooff, T.J.4
  • 22
    • 33744521921 scopus 로고    scopus 로고
    • Bone remodelling inside a cemented resurfaced femoral head
    • Gupta, S., New, A. M. R., and Taylor, M. Bone remodelling inside a cemented resurfaced femoral head. Clin. Biomechanics, 2006, 21(6), 594-602.
    • (2006) Clin. Biomechanics , vol.21 , Issue.6 , pp. 594-602
    • Gupta, S.1    New, A.M.R.2    Taylor, M.3
  • 24
    • 4544332678 scopus 로고    scopus 로고
    • Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis
    • Beaule, P. E., Lee, J. L., Le Duff, M. J., Amstutz, H. C., and Ebramzadeh, E. Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. J. Bone Jt Surg. Am., 2004, 86(9), 2015-2021.
    • (2004) J. Bone Jt Surg. Am , vol.86 , Issue.9 , pp. 2015-2021
    • Beaule, P.E.1    Lee, J.L.2    Le Duff, M.J.3    Amstutz, H.C.4    Ebramzadeh, E.5
  • 25
    • 36748998919 scopus 로고    scopus 로고
    • Proximal femoral bone mineral density after resurfacing total hip arthroplasty and after standard stem-type cementless total hip arthroplasty, both having similar neck preservation and the same articulation type
    • Hayaishi, Y., Miki, H., Nishii, T., Hananouchi, T., Yoshikawa, H., and Sugano, N. Proximal femoral bone mineral density after resurfacing total hip arthroplasty and after standard stem-type cementless total hip arthroplasty, both having similar neck preservation and the same articulation type. J. Arthroplasty, 2007, 22(8), 1208-1213.
    • (2007) J. Arthroplasty , vol.22 , Issue.8 , pp. 1208-1213
    • Hayaishi, Y.1    Miki, H.2    Nishii, T.3    Hananouchi, T.4    Yoshikawa, H.5    Sugano, N.6
  • 26
    • 0024639289 scopus 로고
    • Proximal femoral surface strain gauge analysis of a new epiphyseal prosthesis
    • Field, R. E. and Rushton, N. Proximal femoral surface strain gauge analysis of a new epiphyseal prosthesis. J. Biomed. Engng, 1989, 11, 123-129.
    • (1989) J. Biomed. Engng , vol.11 , pp. 123-129
    • Field, R.E.1    Rushton, N.2
  • 27
    • 42049119677 scopus 로고    scopus 로고
    • Ganapathi, M., Evans, S., and Roberts, P. Strain pattern following surface replacement of the hip. Proc. IMechE, Part H: J. Engineering in Medicine, 2008, 222(1), 13-18.
    • Ganapathi, M., Evans, S., and Roberts, P. Strain pattern following surface replacement of the hip. Proc. IMechE, Part H: J. Engineering in Medicine, 2008, 222(1), 13-18.
  • 28
    • 0031408302 scopus 로고    scopus 로고
    • A critical analysis of stress shielding evaluation of hip prostheses
    • Cristofolini, L. A critical analysis of stress shielding evaluation of hip prostheses. Criti. Rev. Biomed. Engng, 1997, 25(4-5), 409-483.
    • (1997) Criti. Rev. Biomed. Engng , vol.25 , Issue.4-5 , pp. 409-483
    • Cristofolini, L.1
  • 29
    • 0032650491 scopus 로고    scopus 로고
    • Towards the standardization of in vitro load transfer investigations of hip prostheses
    • Cristofolini, L. and Viceconti, M. Towards the standardization of in vitro load transfer investigations of hip prostheses. J. Strain Analysis, 1999, 34(1), 1-15.
    • (1999) J. Strain Analysis , vol.34 , Issue.1 , pp. 1-15
    • Cristofolini, L.1    Viceconti, M.2
  • 30
    • 0020615624 scopus 로고
    • Cross-sectional geometry of Pecos Pueblo femora and tibiae - a biomechanical investigation: I. Method and general patterns of variation
    • Ruff, C. B. and Hayes, W. C. Cross-sectional geometry of Pecos Pueblo femora and tibiae - a biomechanical investigation: I. Method and general patterns of variation. Am. J. Phys. Anthropology, 1983, 60, 359-381.
    • (1983) Am. J. Phys. Anthropology , vol.60 , pp. 359-381
    • Ruff, C.B.1    Hayes, W.C.2
  • 31
    • 65249160298 scopus 로고    scopus 로고
    • Consensus statement on osteoporosis. NIH Consensus Development Conference Consensus Statement Online 5(3), US Department of Health and Human Services, National Institutes of Health, 1984, 2-4 April 1984, pp. 1-6.
    • Consensus statement on osteoporosis. NIH Consensus Development Conference Consensus Statement Online 5(3), US Department of Health and Human Services, National Institutes of Health, 1984, 2-4 April 1984, pp. 1-6.
  • 32
    • 65249174613 scopus 로고    scopus 로고
    • Consensus statement on osteoporosis prevention, diagnosis, and therapy. NIH Consensus Statement Online 17(1), US Department of Health and Human Services, National Institutes of Health, 27-29 March 2000, pp. 1-36.
    • Consensus statement on osteoporosis prevention, diagnosis, and therapy. NIH Consensus Statement Online 17(1), US Department of Health and Human Services, National Institutes of Health, 27-29 March 2000, pp. 1-36.
  • 33
    • 0003911968 scopus 로고    scopus 로고
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis, Report of a WHO study group
    • World Health Organization, Geneva, Switzerland, pp. 1-130
    • Assessment of fracture risk and its application to screening for postmenopausal osteoporosis, Report of a WHO study group. WHO Technical Report 843, World Health Organization, Geneva, Switzerland,994, pp. 1-130.
    • WHO Technical Report , vol.843 , pp. 994
  • 34
    • 0032971991 scopus 로고    scopus 로고
    • In vitro stress shielding measurements can be affected by large errors
    • Cristofolini, L. and Viceconti, M. In vitro stress shielding measurements can be affected by large errors. J. Arthroplasty, 1999, 14(2), 215-219.
    • (1999) J. Arthroplasty , vol.14 , Issue.2 , pp. 215-219
    • Cristofolini, L.1    Viceconti, M.2
  • 37
    • 1642276054 scopus 로고    scopus 로고
    • Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two-year study
    • Glyn-Jones, S., Gill, H. S., McLardy-Smith, P., and Murray, D. Roentgen stereophotogrammetric analysis of the Birmingham hip resurfacing arthroplasty. A two-year study. J. Bone Jt Surg. Br., 2004, 86(2), 172-176.
    • (2004) J. Bone Jt Surg. Br , vol.86 , Issue.2 , pp. 172-176
    • Glyn-Jones, S.1    Gill, H.S.2    McLardy-Smith, P.3    Murray, D.4
  • 38
    • 14044270106 scopus 로고    scopus 로고
    • Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study
    • Itayem, R., Arndt, A., Nistor, L., McMinn, D., and Lundberg, A. Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study. J. Bone Jt Surg Br., 2005, 87(2), 158-162.
    • (2005) J. Bone Jt Surg Br , vol.87 , Issue.2 , pp. 158-162
    • Itayem, R.1    Arndt, A.2    Nistor, L.3    McMinn, D.4    Lundberg, A.5
  • 40
    • 1242269755 scopus 로고    scopus 로고
    • Specialised CT scan protocols for 3-D pre-operative planning of total hip replacement
    • Lattanzi, R., Baruffaldi, F., Zannoni, C., and Viceconti, M. Specialised CT scan protocols for 3-D pre-operative planning of total hip replacement. Med. Engng Physics, 2004, 26(3), 237-245.
    • (2004) Med. Engng Physics , vol.26 , Issue.3 , pp. 237-245
    • Lattanzi, R.1    Baruffaldi, F.2    Zannoni, C.3    Viceconti, M.4
  • 43
    • 34447621807 scopus 로고    scopus 로고
    • Mechanical testing of cancellous bone from the femoral head: Experimental errors due to off-axis measurements
    • Ohman, C., Baleani, M., Perilli, E., Dall'Ara, E., Tassani, S., Baruffaldi, F., and Viceconti, M. Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements. J. Biomechanics, 2007, 40(11), 2426-2433.
    • (2007) J. Biomechanics , vol.40 , Issue.11 , pp. 2426-2433
    • Ohman, C.1    Baleani, M.2    Perilli, E.3    Dall'Ara, E.4    Tassani, S.5    Baruffaldi, F.6    Viceconti, M.7
  • 44
    • 0033881109 scopus 로고    scopus 로고
    • Development and validation of a technique for strain measurement inside polymethylmethacrylate
    • Cristofolini, L. and Viceconti, M. Development and validation of a technique for strain measurement inside polymethylmethacrylate. J. Strain Analysis, 2000, 35(1), 21-33.
    • (2000) J. Strain Analysis , vol.35 , Issue.1 , pp. 21-33
    • Cristofolini, L.1    Viceconti, M.2
  • 46
    • 38449113636 scopus 로고    scopus 로고
    • Cristofolini, L., Varini, E., and Viceconti, M. Invitro method for assessing femoral implant-bone micromotions in resurfacing hip implants under different loading conditions. Proc. IMechE, Part H: J Engineering in Medicine, 2007, 221(8), 943-950.
    • Cristofolini, L., Varini, E., and Viceconti, M. Invitro method for assessing femoral implant-bone micromotions in resurfacing hip implants under different loading conditions. Proc. IMechE, Part H: J Engineering in Medicine, 2007, 221(8), 943-950.
  • 47
    • 33748467122 scopus 로고    scopus 로고
    • Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy
    • Taddei, F., Cristofolini, L., Martelli, S., Gill, H. S., and Viceconti, M. Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy. J. Biomechanics 2006, 39(13), 2457-2467.
    • (2006) J. Biomechanics , vol.39 , Issue.13 , pp. 2457-2467
    • Taddei, F.1    Cristofolini, L.2    Martelli, S.3    Gill, H.S.4    Viceconti, M.5
  • 48
    • 0029294167 scopus 로고
    • Influence of thigh muscles on the axial strains in a proximal femur during early stance in gait
    • Cristofolini, L., Viceconti, M., Toni, A., and Giunti, A. Influence of thigh muscles on the axial strains in a proximal femur during early stance in gait. J. Biomechanics, 1995, 28(5), 617-624.
    • (1995) J. Biomechanics , vol.28 , Issue.5 , pp. 617-624
    • Cristofolini, L.1    Viceconti, M.2    Toni, A.3    Giunti, A.4
  • 49
    • 34548575173 scopus 로고    scopus 로고
    • In vitro replication of spontaneous fractures of the proximal human femur
    • Cristofolini, L., Juszczyk, M., Martelli, S., Taddei, F., and Viceconti, M. In vitro replication of spontaneous fractures of the proximal human femur. J. Biomechanics, 2007, 40(13), 2837-2845.
    • (2007) J. Biomechanics , vol.40 , Issue.13 , pp. 2837-2845
    • Cristofolini, L.1    Juszczyk, M.2    Martelli, S.3    Taddei, F.4    Viceconti, M.5
  • 50
    • 23244463551 scopus 로고    scopus 로고
    • Predicting proximal femoral strength using structural engineering models
    • Keyak, J. H., Kaneko, T. S., Tehranzadeh, J., and Skinner, H. B. Predicting proximal femoral strength using structural engineering models. Clin. Orthop. Related Res., 2005, 437, 219-228.
    • (2005) Clin. Orthop. Related Res , vol.437 , pp. 219-228
    • Keyak, J.H.1    Kaneko, T.S.2    Tehranzadeh, J.3    Skinner, H.B.4
  • 51
    • 0033213780 scopus 로고    scopus 로고
    • Femoral strength is better predicted by finite element models than QCT and DXA
    • Cody, D. D., Gross, G. J., Hou, F. J., Spencer, H. J., Goldstein, S. A., and Fyhrie, D. P. Femoral strength is better predicted by finite element models than QCT and DXA. J. Biomechanics, 1999, 32(10), 1013-1020.
    • (1999) J. Biomechanics , vol.32 , Issue.10 , pp. 1013-1020
    • Cody, D.D.1    Gross, G.J.2    Hou, F.J.3    Spencer, H.J.4    Goldstein, S.A.5    Fyhrie, D.P.6
  • 52
    • 0025836580 scopus 로고
    • Fracture prediction for the proximal femur using finite element models: Part I - linear analysis
    • Lotz, J. C., Cheal, E. J., and Hayes, W. C. Fracture prediction for the proximal femur using finite element models: Part I - linear analysis. J. Biomech. Engng, 1991, 113(4), 353-360.
    • (1991) J. Biomech. Engng , vol.113 , Issue.4 , pp. 353-360
    • Lotz, J.C.1    Cheal, E.J.2    Hayes, W.C.3
  • 53
    • 0036137248 scopus 로고    scopus 로고
    • Mechanical strength of the proximal femur as predicted from geometric and densitometric bone properties at the lower limb versus the distal radius
    • Lochmüller, E.-M., Groll, O., Kuhn, V., and Eckstein, F. Mechanical strength of the proximal femur as predicted from geometric and densitometric bone properties at the lower limb versus the distal radius. Bone, 2002, 30(1), 207-216.
    • (2002) Bone , vol.30 , Issue.1 , pp. 207-216
    • Lochmüller, E.-M.1    Groll, O.2    Kuhn, V.3    Eckstein, F.4
  • 56
    • 0034989298 scopus 로고    scopus 로고
    • Hipjoint abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction
    • Stolk, J., Verdonschot, N., and Huiskes, R. Hipjoint abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. J. Biomechanics, 2001, 34, 917-926.
    • (2001) J. Biomechanics , vol.34 , pp. 917-926
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 57
    • 0027579797 scopus 로고
    • Do bone ingrowth processes produce a globally optimized structure?
    • Hollister, S. J., Kikuchi, N., and Goldstein, S. A. Do bone ingrowth processes produce a globally optimized structure? J. Biomechanics, 1993, 26(4-5), 391-407.
    • (1993) J. Biomechanics , vol.26 , Issue.4-5 , pp. 391-407
    • Hollister, S.J.1    Kikuchi, N.2    Goldstein, S.A.3
  • 58
    • 0026970492 scopus 로고
    • The behavior of adaptive bone-remodeling simulation models
    • Weinans, H., Huiskes, R., and Grootenboer, H. J. The behavior of adaptive bone-remodeling simulation models. J. Biomechanics, 1992, 25(12), 1425- 1441.
    • (1992) J. Biomechanics , vol.25 , Issue.12 , pp. 1425-1441
    • Weinans, H.1    Huiskes, R.2    Grootenboer, H.J.3
  • 59
    • 0028385288 scopus 로고
    • Bone remodeling and structural optimization
    • Harrigan, T. P. and Hamilton, J. J. Bone remodeling and structural optimization. J. Biomechanics,1994, 27(3), 323-328.
    • (1994) J. Biomechanics , vol.27 , Issue.3 , pp. 323-328
    • Harrigan, T.P.1    Hamilton, J.J.2
  • 60
    • 0031277777 scopus 로고    scopus 로고
    • In vivo measuments show tensile axial strain in the proximal lateral aspect of the human femur
    • Aamodt, A., Lund-Larsen, J., Eine, J., Andersen, E., Benum, P., and Husby, O. S. In vivo measuments show tensile axial strain in the proximal lateral aspect of the human femur. J. Orthop. Res., 1997, 15(6), 927-931.
    • (1997) J. Orthop. Res , vol.15 , Issue.6 , pp. 927-931
    • Aamodt, A.1    Lund-Larsen, J.2    Eine, J.3    Andersen, E.4    Benum, P.5    Husby, O.S.6
  • 61
    • 65249153626 scopus 로고    scopus 로고
    • Lanyon, I. E. Bone remodelling, mechanical stress, and osteoporosis. In Osteoporosis (Ed. H. F. De Luca), 1980, pp. 129-138 (University Park Press, Baltimore, Maryland).
    • Lanyon, I. E. Bone remodelling, mechanical stress, and osteoporosis. In Osteoporosis (Ed. H. F. De Luca), 1980, pp. 129-138 (University Park Press, Baltimore, Maryland).
  • 62
    • 4544312502 scopus 로고    scopus 로고
    • Fracture of the neck of the femur after surface arthroplasty of the hip
    • Amstutz, H. C., Campbell, P. A., and Le Duff, M. J. Fracture of the neck of the femur after surface arthroplasty of the hip. J. Bone Jt Surg. Am., 2004, 86, 1874-1877.
    • (2004) J. Bone Jt Surg. Am , vol.86 , pp. 1874-1877
    • Amstutz, H.C.1    Campbell, P.A.2    Le Duff, M.J.3
  • 63
    • 49549113412 scopus 로고    scopus 로고
    • Cristofolini, L., Taddei, F., Baleani, M., Baruffaldi, F., Stea, S., and Viceconti, M. Multiscale investigation of the functional properties of the human femur. Phil. Trans. A, 2008, 366(1879), 3319-3341
    • Cristofolini, L., Taddei, F., Baleani, M., Baruffaldi, F., Stea, S., and Viceconti, M. Multiscale investigation of the functional properties of the human femur. Phil. Trans. A, 2008, 366(1879), 3319-3341


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.