-
1
-
-
0028798063
-
The problem is osteolysis
-
Harris W.H. The problem is osteolysis. Clin Orthop 311 (1995) 46-53
-
(1995)
Clin Orthop
, vol.311
, pp. 46-53
-
-
Harris, W.H.1
-
2
-
-
0028836831
-
The origin of submicron polyethylene wear debris in total hip arthroplasty
-
McKellop H.A., Campbell P., and Park S.H. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orth Rel Res 311 (1995) 3-20
-
(1995)
Clin Orth Rel Res
, vol.311
, pp. 3-20
-
-
McKellop, H.A.1
Campbell, P.2
Park, S.H.3
-
4
-
-
84888479051
-
-
National Joint Registry for England and Wales, 4th Annual Report 2007. ISSN 1753-9382. www.njrcentre.org.uk
-
National Joint Registry for England and Wales, 4th Annual Report 2007. ISSN 1753-9382. www.njrcentre.org.uk
-
-
-
-
5
-
-
0024330679
-
Asceptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads
-
Lombardi Jr. A.V., Mallory T.H., Vaughn B.K., and Drouillard P. Asceptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. J Bone Joint Surg Am 71A (1989) 1337-1342
-
(1989)
J Bone Joint Surg Am
, vol.71 A
, pp. 1337-1342
-
-
Lombardi Jr., A.V.1
Mallory, T.H.2
Vaughn, B.K.3
Drouillard, P.4
-
6
-
-
0031982056
-
Migration and wear of long term successful Charnley total hip replacements
-
Ilchmann T., Markovic L., Joshi A., Hardinge K., Murphy J., and Wingstrand H. Migration and wear of long term successful Charnley total hip replacements. J Bone Joint Surg Br 80-B (1998) 377-381
-
(1998)
J Bone Joint Surg Br
, vol.80 -B
, pp. 377-381
-
-
Ilchmann, T.1
Markovic, L.2
Joshi, A.3
Hardinge, K.4
Murphy, J.5
Wingstrand, H.6
-
7
-
-
0033027601
-
Charnley low frictional torque arthroplasty of the hip, 20-30 year resuls
-
Wroblewski B.M., Fleming P.A., and Siney P.D. Charnley low frictional torque arthroplasty of the hip, 20-30 year resuls. J Bone Joint Surg Br 81-B (1999) 427-430
-
(1999)
J Bone Joint Surg Br
, vol.81 -B
, pp. 427-430
-
-
Wroblewski, B.M.1
Fleming, P.A.2
Siney, P.D.3
-
9
-
-
0035181446
-
Alternative bearing surfaces: the good, the bad and the ugly
-
Greenwald A., and Garino J.P. Alternative bearing surfaces: the good, the bad and the ugly. J Bone Joint Surg Am 83-A (2001) 68-72
-
(2001)
J Bone Joint Surg Am
, vol.83 -A
, pp. 68-72
-
-
Greenwald, A.1
Garino, J.P.2
-
10
-
-
33845510652
-
Highly cross-linked polyethylene in total hip arthroplasty
-
Gordon A.C., D'Lima D.D., and Colwell Jr. C.W. Highly cross-linked polyethylene in total hip arthroplasty. J Am Acad Orthop 14 9 (2006) 511-523
-
(2006)
J Am Acad Orthop
, vol.14
, Issue.9
, pp. 511-523
-
-
Gordon, A.C.1
D'Lima, D.D.2
Colwell Jr., C.W.3
-
11
-
-
9644279463
-
Fatigue crack propagation resistance of highly cross- linked polyethylene
-
Bradford L., Baker D., Ries M.D., et al. Fatigue crack propagation resistance of highly cross- linked polyethylene. Clin Orthop Relat Res 429 (2004) 68-72
-
(2004)
Clin Orthop Relat Res
, vol.429
, pp. 68-72
-
-
Bradford, L.1
Baker, D.2
Ries, M.D.3
-
12
-
-
35349019671
-
Rim cracking of the Cross-linked Longevity acetabular liner after total hip arthroplasty
-
Tower S.S., Currier J.H., Currier B.H., Lyford K.A., van Citters D.W., and Mayor M.B. Rim cracking of the Cross-linked Longevity acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 89 (2007) 2212-2217
-
(2007)
J Bone Joint Surg Am
, vol.89
, pp. 2212-2217
-
-
Tower, S.S.1
Currier, J.H.2
Currier, B.H.3
Lyford, K.A.4
van Citters, D.W.5
Mayor, M.B.6
-
13
-
-
27644448756
-
Effects of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene
-
Ries M.D., and Pruitt L. Effects of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orth Rel Res 440 (2005) 149-156
-
(2005)
Clin Orth Rel Res
, vol.440
, pp. 149-156
-
-
Ries, M.D.1
Pruitt, L.2
-
15
-
-
0035117295
-
A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation and retain mechanical properties
-
Muratogolu O.K., Bragdon C.R., O'Connor D.O., Jasty M., and Harrris W.H. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation and retain mechanical properties. J Arthroplasty 16 (2001) 149-160
-
(2001)
J Arthroplasty
, vol.16
, pp. 149-160
-
-
Muratogolu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harrris, W.H.5
-
16
-
-
0345060377
-
Comparison of the wear rates of twenty-eight and thirty-two millimetre femoral heads on cross-linked polyethylene acetabular cups in a wear simulator
-
Hermida J.C., Bergula A., Chen P., et al. Comparison of the wear rates of twenty-eight and thirty-two millimetre femoral heads on cross-linked polyethylene acetabular cups in a wear simulator. J Bone Joint Surg Am 85 (2003) 2325-2331
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 2325-2331
-
-
Hermida, J.C.1
Bergula, A.2
Chen, P.3
-
17
-
-
0344629811
-
Highly cross-linked polyethylene in cemented THA: Randomised study of 61 hips
-
Digas G., Karrholm J., Thanner J., et al. Highly cross-linked polyethylene in cemented THA: Randomised study of 61 hips. Clin Othop Relat Res 417 (2003) 126-138
-
(2003)
Clin Othop Relat Res
, vol.417
, pp. 126-138
-
-
Digas, G.1
Karrholm, J.2
Thanner, J.3
-
18
-
-
9644254123
-
Highly cross-linked polyethylene in total hip arthroplasty: Randomised evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
-
Digas G., Karrholm J., Thanner J., et al. Highly cross-linked polyethylene in total hip arthroplasty: Randomised evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Othop Rel Res 429 (2004) 6-16
-
(2004)
Clin Othop Rel Res
, vol.429
, pp. 6-16
-
-
Digas, G.1
Karrholm, J.2
Thanner, J.3
-
19
-
-
34548215091
-
Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36 vs 28mm femoral heads
-
Bragdon C.R., Greene M.E., Freiberg A.A., et al. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36 vs 28mm femoral heads. J Arthroplasty 22 6 (2007) 125-129
-
(2007)
J Arthroplasty
, vol.22
, Issue.6
, pp. 125-129
-
-
Bragdon, C.R.1
Greene, M.E.2
Freiberg, A.A.3
-
20
-
-
33747887186
-
A randomised prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non cross-linked Eduron polyethylene liners
-
Engh C.A., Stepniewski A.S., Ginn S.D., et al. A randomised prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non cross-linked Eduron polyethylene liners. J Arthroplasty 21 2 (2006) 17-25
-
(2006)
J Arthroplasty
, vol.21
, Issue.2
, pp. 17-25
-
-
Engh, C.A.1
Stepniewski, A.S.2
Ginn, S.D.3
-
21
-
-
37249071262
-
A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking
-
Triclot P., Grosjean G., El Masri F., et al. A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. J Bone Joint Surg Br 89 (2007) 1439-1445
-
(2007)
J Bone Joint Surg Br
, vol.89
, pp. 1439-1445
-
-
Triclot, P.1
Grosjean, G.2
El Masri, F.3
-
22
-
-
23044492290
-
Clinical performance of a Durasul highly cross-linked polyethylene liner for total hip arthroplasty at five years
-
Dorr L.D., Wan Z., Shahrdar C., et al. Clinical performance of a Durasul highly cross-linked polyethylene liner for total hip arthroplasty at five years. J Bone Joint Surg Am 87 (2005) 1816-1821
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 1816-1821
-
-
Dorr, L.D.1
Wan, Z.2
Shahrdar, C.3
-
23
-
-
0025350439
-
Unsatisfactory results with ceramic total hip prosthesis
-
Mahoney O.M., and Dimron III J.H. Unsatisfactory results with ceramic total hip prosthesis. J Bone Joint Surg Am 72A (1990) 663-671
-
(1990)
J Bone Joint Surg Am
, vol.72 A
, pp. 663-671
-
-
Mahoney, O.M.1
Dimron III, J.H.2
-
24
-
-
0033641059
-
Ultra low wear rates for rigid on rigid bearings in total hip replacements
-
Clarke I.C., Good V., and Williams P. Ultra low wear rates for rigid on rigid bearings in total hip replacements. Proc Inst Mech Eng (H) 214 (2000) 331-347
-
(2000)
Proc Inst Mech Eng (H)
, vol.214
, pp. 331-347
-
-
Clarke, I.C.1
Good, V.2
Williams, P.3
-
25
-
-
34249933860
-
Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation
-
Walter W.L., O'Toole G.C., Walter W.K., Ellis A., and Zicat B.A. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 22 (2007) 496-503
-
(2007)
J Arthroplasty
, vol.22
, pp. 496-503
-
-
Walter, W.L.1
O'Toole, G.C.2
Walter, W.K.3
Ellis, A.4
Zicat, B.A.5
-
26
-
-
38949161946
-
Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty
-
Koo K.H., Ha Y.C., Jung W.H., Kim S.R., Yoo J.J., and Kim H.J. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am 90 (2008) 329-336
-
(2008)
J Bone Joint Surg Am
, vol.90
, pp. 329-336
-
-
Koo, K.H.1
Ha, Y.C.2
Jung, W.H.3
Kim, S.R.4
Yoo, J.J.5
Kim, H.J.6
-
28
-
-
0029831455
-
In vivo wear of three types of metal on metal hip prosthesis during two decades of use
-
McKellop H., Park S.H., and Chiesa R. In vivo wear of three types of metal on metal hip prosthesis during two decades of use. Clin Orthop 329 Suppl (1996) S128-S140
-
(1996)
Clin Orthop
, vol.329
, Issue.SUPPL
-
-
McKellop, H.1
Park, S.H.2
Chiesa, R.3
-
29
-
-
0029790388
-
Twenty year results of McKee-Farrar versus Charnley prosthesis
-
Jacbsson S.A., Djerf K., and Wahlstrom O. Twenty year results of McKee-Farrar versus Charnley prosthesis. Clin Orthop 329 Suppl (1996) S60-S68
-
(1996)
Clin Orthop
, vol.329
, Issue.SUPPL
-
-
Jacbsson, S.A.1
Djerf, K.2
Wahlstrom, O.3
-
30
-
-
0032190304
-
Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles
-
Doom P.F., Campbell P.A., and Worrall J. Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42 (1998) 103-111
-
(1998)
J Biomed Mater Res
, vol.42
, pp. 103-111
-
-
Doom, P.F.1
Campbell, P.A.2
Worrall, J.3
-
31
-
-
9644279533
-
Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty
-
Brodner W., Grübl A., Jankovsky R., Meisinger V., Lehr S., and Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19 Suppl 3 (2004) 66-70
-
(2004)
J Arthroplasty
, vol.19
, Issue.SUPPL. 3
, pp. 66-70
-
-
Brodner, W.1
Grübl, A.2
Jankovsky, R.3
Meisinger, V.4
Lehr, S.5
Gottsauner-Wolf, F.6
-
32
-
-
0030905094
-
Elevated serum cobalt with metal on metal articulating surfaces
-
activity and ions in patients with metal on metal bearing hip prostheses. J Bone Joint Surg A 2005; 87: 781-787
-
Brodner W., Bitzan P., Meisinger V., Kaider A., Gottsauner-Wolf F., and Kotz R. Elevated serum cobalt with metal on metal articulating surfaces. J Bone Joint Surg B 79 (1997) 316-332 activity and ions in patients with metal on metal bearing hip prostheses. J Bone Joint Surg A 2005; 87: 781-787
-
(1997)
J Bone Joint Surg B
, vol.79
, pp. 316-332
-
-
Brodner, W.1
Bitzan, P.2
Meisinger, V.3
Kaider, A.4
Gottsauner-Wolf, F.5
Kotz, R.6
-
33
-
-
16844377563
-
The relationship between activity and ions in patients with metal on metal bearing hip prostheses
-
Heisel C., Silva M., Skipor A.K., Jacobs J.J., and Schmalzreid T.P. The relationship between activity and ions in patients with metal on metal bearing hip prostheses. J Bone Joint Surg Am 87 (2005) 781-787
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 781-787
-
-
Heisel, C.1
Silva, M.2
Skipor, A.K.3
Jacobs, J.J.4
Schmalzreid, T.P.5
-
34
-
-
11844293972
-
Metal on metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
-
Willert H.G., Buchhorn G.H., and Fayyazi A. Metal on metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87 (2005) 28-36
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 28-36
-
-
Willert, H.G.1
Buchhorn, G.H.2
Fayyazi, A.3
-
35
-
-
0035207851
-
Chromosomal changes after surgery for joint replacement
-
Case C.P. Chromosomal changes after surgery for joint replacement. J Bone Joint Surg Br 83 (2001) 1093-1095
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 1093-1095
-
-
Case, C.P.1
-
36
-
-
0034999690
-
The risk of cancer following total hip or knee arthroplasty
-
Tharani R., Dorey F.J., and Schmalzried T.P. The risk of cancer following total hip or knee arthroplasty. J Bone Joint Surg Am 83 (2001) 774-780
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 774-780
-
-
Tharani, R.1
Dorey, F.J.2
Schmalzried, T.P.3
-
37
-
-
0031573493
-
Effects of metal ions on white blood cells of patients with failed total joint arthroplasties
-
Savarino L., Granchi D., Ciapetti G., et al. Effects of metal ions on white blood cells of patients with failed total joint arthroplasties. J Biomed Mater Res 47 (1999) 543-550
-
(1999)
J Biomed Mater Res
, vol.47
, pp. 543-550
-
-
Savarino, L.1
Granchi, D.2
Ciapetti, G.3
-
38
-
-
0033944829
-
Changes in the proportions of peripheral blood lymphocytes in patients with worn implants
-
Case C.P., Langkamer V.G., Lock R.J., Perry M.J., Palmer M.R., and Kemp A.J. Changes in the proportions of peripheral blood lymphocytes in patients with worn implants. J Bone Joint Surg Br 82 (2000) 748-754
-
(2000)
J Bone Joint Surg Br
, vol.82
, pp. 748-754
-
-
Case, C.P.1
Langkamer, V.G.2
Lock, R.J.3
Perry, M.J.4
Palmer, M.R.5
Kemp, A.J.6
-
39
-
-
0042169044
-
Immunological changes in patients with primary osteoarthritis of the hip after total joint replacement
-
Granchi D., Savarino L., Ciapetti G., et al. Immunological changes in patients with primary osteoarthritis of the hip after total joint replacement. J Bone Joint Surg Br 85 (2003) 758-764
-
(2003)
J Bone Joint Surg Br
, vol.85
, pp. 758-764
-
-
Granchi, D.1
Savarino, L.2
Ciapetti, G.3
-
41
-
-
62149143312
-
-
IARC, Lyon, France
-
International Agency for Research on Cancer, World Health Organization. IARC monographs on the evaluation of carcinogenic risks to humans. Cobalt in hard metals and cobalt sulfate, gallium arsenide, indium phosphide and vanadium pentoxide Vol 86 (2003), IARC, Lyon, France
-
(2003)
IARC monographs on the evaluation of carcinogenic risks to humans. Cobalt in hard metals and cobalt sulfate, gallium arsenide, indium phosphide and vanadium pentoxide
, vol.86
-
-
International Agency for Research on Cancer, World Health Organization,1
-
42
-
-
0025963553
-
Cancer risk after McKee-Farrar total hip replacement
-
Visuri T., and Koskenvuo M. Cancer risk after McKee-Farrar total hip replacement. Orthopedics 14 (1991) 137-142
-
(1991)
Orthopedics
, vol.14
, pp. 137-142
-
-
Visuri, T.1
Koskenvuo, M.2
-
43
-
-
0029789979
-
Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty
-
Visuri T., Pukkala E., Paavolainen P., Pulkkinen P., and Riska E.B. Cancer risk after metal on metal and polyethylene on metal total hip arthroplasty. Clin Orthop 329 Suppl (1996) S280-S289
-
(1996)
Clin Orthop
, vol.329
, Issue.SUPPL
-
-
Visuri, T.1
Pukkala, E.2
Paavolainen, P.3
Pulkkinen, P.4
Riska, E.B.5
-
44
-
-
0034890636
-
A novel low wearing differential hardness ceramic-on-metal hip joint prosthesis
-
Firkins P.J., Tipper J.L., Ingham E., et al. A novel low wearing differential hardness ceramic-on-metal hip joint prosthesis. J Biomech 34 (2001) 1291-1298
-
(2001)
J Biomech
, vol.34
, pp. 1291-1298
-
-
Firkins, P.J.1
Tipper, J.L.2
Ingham, E.3
-
45
-
-
84888479060
-
-
Williams S, Ingham E, Isaac G, et al. Ceramic on metal hip replacements: Part 1 in vitro testing. (extended abstractat the London hip meeting. London 2007).
-
Williams S, Ingham E, Isaac G, et al. Ceramic on metal hip replacements: Part 1 in vitro testing. (extended abstractat the London hip meeting. London 2007).
-
-
-
-
46
-
-
33645689325
-
Use of cost effectiveness analysis to evaluate new technologies in Orthopaedics: The case of alternative bearing surfaces in total hip arthroplasty
-
Bozic K.J., Morshed S., Silverstein M.D., Rubash H.E., and Kahn J.G. Use of cost effectiveness analysis to evaluate new technologies in Orthopaedics: The case of alternative bearing surfaces in total hip arthroplasty. J Bone Joint Surg Am 88 (2006) 706-714
-
(2006)
J Bone Joint Surg Am
, vol.88
, pp. 706-714
-
-
Bozic, K.J.1
Morshed, S.2
Silverstein, M.D.3
Rubash, H.E.4
Kahn, J.G.5
|