메뉴 건너뛰기




Volumn 417, Issue , 2003, Pages 126-138

Highly Cross-Linked Polyethylene in Cemented THA: Randomized Study of 61 Hips

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; BIOMATERIAL; BONE CEMENT; CHROMIUM; COBALT; POLYETHYLENE;

EID: 0344629811     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (137)

References (43)
  • 1
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L: Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res 46:573-581, 1999.
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 2
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty
    • Barrack LR, Mulroy Jr RD, Harris WH: Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. J Bone Joint Surg 74B:385-389, 1992.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 385-389
    • Barrack, L.R.1    Mulroy Jr., R.D.2    Harris, W.H.3
  • 3
    • 0023007566 scopus 로고
    • The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg 68A:1041-1051, 1986.
    • (1986) J Bone Joint Surg , vol.68 A , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 5
    • 0036316748 scopus 로고    scopus 로고
    • Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in total hip replacement model
    • Bragdon CR, Malchau H, Yuan X, et al: Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in total hip replacement model. J Orthop Res 20:688-695, 2002.
    • (2002) J Orthop Res , vol.20 , pp. 688-695
    • Bragdon, C.R.1    Malchau, H.2    Yuan, X.3
  • 6
    • 0015754154 scopus 로고
    • Ectopic ossification following total hip replacement: Incidence and method of classification
    • Brooker AF, Bowerman JW, Robinson RA, Riley LH: Ectopic ossification following total hip replacement: Incidence and method of classification. J Bone Joint Surg 55A:1629-1632, 1973.
    • (1973) J Bone Joint Surg , vol.55 A , pp. 1629-1632
    • Brooker, A.F.1    Bowerman, J.W.2    Robinson, R.A.3    Riley, L.H.4
  • 8
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J: Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20-32, 1976.
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 9
    • 0344927558 scopus 로고    scopus 로고
    • Assessment of polyethylene wear in total hip replacement
    • Devane PA, Horne JG: Assessment of polyethylene wear in total hip replacement. Clin Orthop 369:59-72, 1999.
    • (1999) Clin Orthop , vol.369 , pp. 59-72
    • Devane, P.A.1    Horne, J.G.2
  • 10
    • 0344062950 scopus 로고    scopus 로고
    • Increase early femoral head penetration using ethylene oxide sterilized polyethylene
    • Published October
    • Digas G, Thanner J, Nivbrand B, et al: Increase early femoral head penetration using ethylene oxide sterilized polyethylene. Acta Orthop Scand. Published October 2003.
    • (2003) Acta Orthop Scand
    • Digas, G.1    Thanner, J.2    Nivbrand, B.3
  • 11
    • 0025648955 scopus 로고
    • Wear and loosening of the hip prosthesis: A roentgen stereophotogrammetric 3-year study of 14 cases
    • Franzen H, Mjöberg B: Wear and loosening of the hip prosthesis: A roentgen stereophotogrammetric 3-year study of 14 cases. Acta Orthop Scand 61:499-501, 1990.
    • (1990) Acta Orthop Scand , vol.61 , pp. 499-501
    • Franzen, H.1    Mjöberg, B.2
  • 12
    • 0018186475 scopus 로고
    • The radiation improvement of polyethylene prostheses: A preliminary study
    • Grobbelaar CJ, du Plessis TAD, Marais F: The radiation improvement of polyethylene prostheses: A preliminary study. J Bone Joint Surg 60B:370-374, 1978.
    • (1978) J Bone Joint Surg , vol.60 B , pp. 370-374
    • Grobbelaar, C.J.1    Du Plessis, T.A.D.2    Marais, F.3
  • 13
    • 0001379590 scopus 로고    scopus 로고
    • Clinical experience with gamma irradiation cross-linked polyethylene: A 14 to 20 year follow-up report
    • Grobbelaar CJ, Weber FA, Spirakis A, et al: Clinical experience with gamma irradiation cross-linked polyethylene: A 14 to 20 year follow-up report. S Afr Bone Joint Surg 9:140-147, 1999.
    • (1999) S Afr Bone Joint Surg , vol.9 , pp. 140-147
    • Grobbelaar, C.J.1    Weber, F.A.2    Spirakis, A.3
  • 14
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: An end-result study using a new method of result evaluation
    • Harris WH: Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: An end-result study using a new method of result evaluation. J Bone Joint Surg 51A:737-755, 1969.
    • (1969) J Bone Joint Surg , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 15
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • Harris WH: The problem is osteolysis. Clin Orthop 311:46-53, 1995.
    • (1995) Clin Orthop , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 16
    • 0030331025 scopus 로고    scopus 로고
    • An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cupswear, creep or degradation?
    • Isaac GH, Dowson D, Wroblewski BM: An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cupswear, creep or degradation? Proc Inst Mech Eng H 210:209-216, 1996.
    • (1996) Proc Inst Mech Eng H , vol.210 , pp. 209-216
    • Isaac, G.H.1    Dowson, D.2    Wroblewski, B.M.3
  • 18
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty: An analysis of 128 components retrieved at autopsy or revision
    • Jasty MJ, Goetz DD, Lee KR, et al: Wear of polyethylene acetabular components in total hip arthroplasty: An analysis of 128 components retrieved at autopsy or revision. J Bone Joint Surg 79A:349-358, 1997.
    • (1997) J Bone Joint Surg , vol.79 A , pp. 349-358
    • Jasty, M.J.1    Goetz, D.D.2    Lee, K.R.3
  • 19
    • 0343118727 scopus 로고    scopus 로고
    • Radiostereometry of hip prostheses: Review of methodology and clinical results
    • Kärrholm J, Herberts P, Hultmark P, et al: Radiostereometry of hip prostheses: Review of methodology and clinical results. Clin Orthop 344:94-110, 1997.
    • (1997) Clin Orthop , vol.344 , pp. 94-110
    • Kärrholm, J.1    Herberts, P.2    Hultmark, P.3
  • 20
    • 0028558592 scopus 로고
    • Periprosthetic bone mineral density after Mueller and Zweymueller total hip arthroplasties
    • Korovessis P, Piperos G, Michael A: Periprosthetic bone mineral density after Mueller and Zweymueller total hip arthroplasties. Clin Orthop 309:214-221, 1994.
    • (1994) Clin Orthop , vol.309 , pp. 214-221
    • Korovessis, P.1    Piperos, G.2    Michael, A.3
  • 21
    • 0033179629 scopus 로고    scopus 로고
    • Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions
    • Kurtz SM, Pruitt LA, Jewett CW, et al: Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions. Biomaterials 20:1449-1462, 1999.
    • (1999) Biomaterials , vol.20 , pp. 1449-1462
    • Kurtz, S.M.1    Pruitt, L.A.2    Jewett, C.W.3
  • 22
    • 0027765535 scopus 로고
    • Computer simulations of stress-related bone remodelling around noncemented acetabular components
    • Levenstone ME, Beaupre GS, Schurman DJ, Carter DR: Computer simulations of stress-related bone remodelling around noncemented acetabular components. J Arthroplasty 8:595-605, 1993.
    • (1993) J Arthroplasty , vol.8 , pp. 595-605
    • Levenstone, M.E.1    Beaupre, G.S.2    Schurman, D.J.3    Carter, D.R.4
  • 23
    • 0036054006 scopus 로고    scopus 로고
    • Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
    • Mak MM, Besong AA, Jin ZM, Fisher J: Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proc Inst Mech Eng H 216:403-408, 2002.
    • (2002) Proc Inst Mech Eng H , vol.216 , pp. 403-408
    • Mak, M.M.1    Besong, A.A.2    Jin, Z.M.3    Fisher, J.4
  • 24
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements
    • Mc Kellop H, Shen F-W, Lu B, Campbell P, Salovey R: Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements. J Orthop Res 17:157-167, 1999.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • Mc Kellop, H.1    Shen, F.-W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 25
    • 0033178826 scopus 로고    scopus 로고
    • Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
    • Muratoglu OK, Bragdon CR, O'Connor DO, et al: Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials 20:1463-1470, 1999.
    • (1999) Biomaterials , vol.20 , pp. 1463-1470
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3
  • 26
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear reduce oxidation and retain mechanical properties
    • Muratoglou OK, Bragdon CR, O'Connor DO, et al: A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear reduce oxidation and retain mechanical properties. J Arthroplasty 16:149-160, 2001.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglou, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3
  • 27
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
    • Muratoglu OK, Bragdon CR, O'Connor D, et al: Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept. J Arthroplasty 16(8 Suppl 1):24-30, 2001.
    • (2001) J Arthroplasty , vol.16 , Issue.8 SUPPL. 1 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3
  • 28
    • 0033814067 scopus 로고    scopus 로고
    • Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
    • Nevelos J, Ingham E, Doyle C, et al: Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 15:793-795, 2000.
    • (2000) J Arthroplasty , vol.15 , pp. 793-795
    • Nevelos, J.1    Ingham, E.2    Doyle, C.3
  • 29
    • 0035664852 scopus 로고    scopus 로고
    • Bone cement with reduced proportion of monomer in total hip arthroplasty: Preclinical evaluation and randomized study of 47 cases with 5 years' follow-up
    • Nivbrant B, Karrholm J, Rohrl S, Hassander H, Wesslen B: Bone cement with reduced proportion of monomer in total hip arthroplasty: Preclinical evaluation and randomized study of 47 cases with 5 years' follow-up. Acta Orthop Scand 72:572-584, 2001.
    • (2001) Acta Orthop Scand , vol.72 , pp. 572-584
    • Nivbrant, B.1    Karrholm, J.2    Rohrl, S.3    Hassander, H.4    Wesslen, B.5
  • 30
    • 0033372584 scopus 로고    scopus 로고
    • Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases
    • Nivbrant B, Kärrholm J, Södelund P: Increased migration of the SHP prosthesis: Radiostereometric comparison with the Lubinus SP2 design in 40 cases. Acta Orthop Scand 70:569-577, 1999.
    • (1999) Acta Orthop Scand , vol.70 , pp. 569-577
    • Nivbrant, B.1    Kärrholm, J.2    Södelund, P.3
  • 31
    • 0035215807 scopus 로고    scopus 로고
    • Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models
    • Onsten I, Berzins A, Shott S, Sumner DR: Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models. J Orthop Res 19:1162-1167, 2001.
    • (2001) J Orthop Res , vol.19 , pp. 1162-1167
    • Onsten, I.1    Berzins, A.2    Shott, S.3    Sumner, D.R.4
  • 32
    • 0026881002 scopus 로고
    • Improvement of polyethylene by irradiation in artificial joints
    • Oonishi H, Takayama Y, Tsuji E: Improvement of polyethylene by irradiation in artificial joints. Radiat Phys Chem 39:495-504, 1992.
    • (1992) Radiat Phys Chem , vol.39 , pp. 495-504
    • Oonishi, H.1    Takayama, Y.2    Tsuji, E.3
  • 33
    • 0033922311 scopus 로고    scopus 로고
    • Wear of high-dose gamma-irradiated polyethylene in total hip replacements
    • Oonishi H, Kadoya Y: Wear of high-dose gamma-irradiated polyethylene in total hip replacements. J Orthop Sci 5:223-228, 2000.
    • (2000) J Orthop Sci , vol.5 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2
  • 34
    • 0028944924 scopus 로고
    • Cyclic compressive loading results in fatigue cracks in ultra high molecular weight polyethylene
    • Pruitt L, Koo J, Rimnac CM, Suresh S, Wright TM: Cyclic compressive loading results in fatigue cracks in ultra high molecular weight polyethylene. J Orthop Res 13:143-146, 1994.
    • (1994) J Orthop Res , vol.13 , pp. 143-146
    • Pruitt, L.1    Koo, J.2    Rimnac, C.M.3    Suresh, S.4    Wright, T.M.5
  • 35
    • 0344915167 scopus 로고    scopus 로고
    • Minimum 10-year results of a tapered cementless hip replacement
    • Sakalkale DP, Eng K, Hozack WJ, Rothman RH: Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop 362:138-144, 1999.
    • (1999) Clin Orthop , vol.362 , pp. 138-144
    • Sakalkale, D.P.1    Eng, K.2    Hozack, W.J.3    Rothman, R.H.4
  • 36
    • 0032945469 scopus 로고    scopus 로고
    • Current concepts review: Wear in total hip and knee replacements
    • Schmalzried TP, Callaghan JJ: Current concepts review: Wear in total hip and knee replacements. J Bone Joint Surg 81A:115-136, 1999.
    • (1999) J Bone Joint Surg , vol.81 A , pp. 115-136
    • Schmalzried, T.P.1    Callaghan, J.J.2
  • 37
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G: Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl: (232) 1-51, 1989.
    • (1989) Acta Orthop Scand Suppl , Issue.232 , pp. 1-51
    • Selvik, G.1
  • 38
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • Söderkvist I, Wedin PA: Determining the movements of the skeleton using well-configured markers. J Biomech 26:1473-1477, 1993.
    • (1993) J Biomech , vol.26 , pp. 1473-1477
    • Söderkvist, I.1    Wedin, P.A.2
  • 39
    • 0034047218 scopus 로고    scopus 로고
    • Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation
    • Thanner J, Kärrholm J, Herberts P, Malchau H: Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation. J Arthroplasty 15:405-412, 2000.
    • (2000) J Arthroplasty , vol.15 , pp. 405-412
    • Thanner, J.1    Kärrholm, J.2    Herberts, P.3    Malchau, H.4
  • 40
    • 0035087712 scopus 로고    scopus 로고
    • Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty
    • Wilkinson JM, Peel NFA, Elson RA, et al: Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty. J Bone Joint Surg 83B:283-288, 2001.
    • (2001) J Bone Joint Surg , vol.83 B , pp. 283-288
    • Wilkinson, J.M.1    Peel, N.F.A.2    Elson, R.A.3
  • 41
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyetethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN: Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyetethylene cups. J Bone Joint Surg 78B:280-285, 1996.
    • (1996) J Bone Joint Surg , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 42
    • 0032922181 scopus 로고    scopus 로고
    • Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene: A ten-year follow-up report
    • Wroblewski BM, Siney PD, Fleming PA: Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene: A ten-year follow-up report. J Bone Joint Surg 81B:54-55, 1999.
    • (1999) J Bone Joint Surg , vol.81 B , pp. 54-55
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 43
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip: The role of ultra-high molecular weight polyethylene wear particles
    • Willert HG, Bertram H, Buchhorn GH: Osteolysis in alloarthroplasty of the hip: The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop 258:95-107, 1990.
    • (1990) Clin Orthop , vol.258 , pp. 95-107
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.