메뉴 건너뛰기




Volumn , Issue , 2006, Pages 393-441

Soft Lens Extended Wear and Complications

Author keywords

[No Author keywords available]

Indexed keywords


EID: 60749119041     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-0-7506-7517-8.50025-0     Document Type: Chapter
Times cited : (10)

References (201)
  • 1
    • 21344457775 scopus 로고    scopus 로고
    • International contact lens prescribing in 2003
    • Morgan P, Efron N, et al. International contact lens prescribing in 2003. CL Spectrum 2004, 19(1):34-37.
    • (2004) CL Spectrum , vol.19 , Issue.1 , pp. 34-37
    • Morgan, P.1    Efron, N.2
  • 3
    • 0015611940 scopus 로고
    • Continuous wear of hydrophilic contact lenses
    • Leibowitz HM, Laing RA, et al. Continuous wear of hydrophilic contact lenses. Arch Ophthalmol 1973, 89(4):306-310.
    • (1973) Arch Ophthalmol , vol.89 , Issue.4 , pp. 306-310
    • Leibowitz, H.M.1    Laing, R.A.2
  • 4
    • 84990556375 scopus 로고
    • High water content hydrophilic contact lenses
    • Ezekiel D High water content hydrophilic contact lenses. Aust J Optom 1974, 57:317-324.
    • (1974) Aust J Optom , vol.57 , pp. 317-324
    • Ezekiel, D.1
  • 5
    • 0017098563 scopus 로고
    • Continuous use of contact lenses
    • Benson C Continuous use of contact lenses. Trans Ophthalmol Soc N Z 1976, 2871-2874.
    • (1976) Trans Ophthalmol Soc N Z , pp. 2871-2874
    • Benson, C.1
  • 6
    • 0019773840 scopus 로고
    • Extended-wear contact lenses for myopic correction
    • Stark WJ, Martin NF Extended-wear contact lenses for myopic correction. Arch Ophthalmol 1981, 99(11):1963-1966.
    • (1981) Arch Ophthalmol , vol.99 , Issue.11 , pp. 1963-1966
    • Stark, W.J.1    Martin, N.F.2
  • 7
    • 0020561301 scopus 로고
    • Myopic extended wear with the Hydrocurve II soft contact lens
    • Binder PS Myopic extended wear with the Hydrocurve II soft contact lens. Ophthalmology 1983, 90(6):623-626.
    • (1983) Ophthalmology , vol.90 , Issue.6 , pp. 623-626
    • Binder, P.S.1
  • 8
    • 0020517555 scopus 로고
    • Pseudomonas corneal ulcer with extended-wear soft contact lenses for myopia
    • Hassman G, Sugar J Pseudomonas corneal ulcer with extended-wear soft contact lenses for myopia. Arch Ophthalmol 1983, 101:1549-1550.
    • (1983) Arch Ophthalmol , vol.101 , pp. 1549-1550
    • Hassman, G.1    Sugar, J.2
  • 9
    • 0021321655 scopus 로고
    • Corneal ulcers associated with extended-wear soft contact lenses
    • Weissman BA, Mondino BJ, et al. Corneal ulcers associated with extended-wear soft contact lenses. Am J Ophthalmol 1984, 97(4):476-481.
    • (1984) Am J Ophthalmol , vol.97 , Issue.4 , pp. 476-481
    • Weissman, B.A.1    Mondino, B.J.2
  • 10
    • 0024415812 scopus 로고
    • Contact lenses-convenience and complications
    • Smith RE, MacRae SM Contact lenses-convenience and complications. N Engl J Med 1989, 321(12):824-826.
    • (1989) N Engl J Med , vol.321 , Issue.12 , pp. 824-826
    • Smith, R.E.1    MacRae, S.M.2
  • 11
    • 0024441105 scopus 로고
    • The incidence of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses
    • Poggio EC, Glynn RJ, et al. The incidence of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses. N Engl J Med 1989, 321(12):779-783.
    • (1989) N Engl J Med , vol.321 , Issue.12 , pp. 779-783
    • Poggio, E.C.1    Glynn, R.J.2
  • 12
    • 0024469313 scopus 로고
    • The relative risk of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses. A case-control study. Microbial Keratitis Study Group
    • Schein OD, Glynn RJ, et al. The relative risk of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses. A case-control study. Microbial Keratitis Study Group. N Engl J Med 1989, 321(12):773-778.
    • (1989) N Engl J Med , vol.321 , Issue.12 , pp. 773-778
    • Schein, O.D.1    Glynn, R.J.2
  • 13
    • 0023815220 scopus 로고
    • Disposable hydrogel contact lenses for extended wear
    • Donshik P, Weinstock F, et al. Disposable hydrogel contact lenses for extended wear. CLAO J 1988, 14(4):191-194.
    • (1988) CLAO J , vol.14 , Issue.4 , pp. 191-194
    • Donshik, P.1    Weinstock, F.2
  • 14
    • 0024383112 scopus 로고
    • Pseudomonas keratitis associated with the use of disposable soft contact lenses
    • Killingsworth D, Stern G Pseudomonas keratitis associated with the use of disposable soft contact lenses. Arch Ophthalmol 1989, 107:795-796.
    • (1989) Arch Ophthalmol , vol.107 , pp. 795-796
    • Killingsworth, D.1    Stern, G.2
  • 15
    • 0033578195 scopus 로고    scopus 로고
    • Incidence of contact-lens-associated microbial keratitis and its related morbidity
    • Cheng KH, Leung SL, et al. Incidence of contact-lens-associated microbial keratitis and its related morbidity. Lancet 1999, 354(9174):181-185.
    • (1999) Lancet , vol.354 , Issue.9174 , pp. 181-185
    • Cheng, K.H.1    Leung, S.L.2
  • 16
    • 31944450712 scopus 로고    scopus 로고
    • Comfort and compliance with frequent replacement soft contact lenses
    • Jones L, Dumbleton K, et al. Comfort and compliance with frequent replacement soft contact lenses. Optom Vis Sci 2002, 79(12s):259.
    • (2002) Optom Vis Sci , vol.79 , Issue.12 S , pp. 259
    • Jones, L.1    Dumbleton, K.2
  • 17
    • 0017268045 scopus 로고
    • Polymers in contact lens applications VI. The "dissolved" oxygen permeability of hydrogel and the design of materials for use in continuous wear lenses
    • Ng C, Tighe B Polymers in contact lens applications VI. The "dissolved" oxygen permeability of hydrogel and the design of materials for use in continuous wear lenses. Br Polymer J 1976, 8:118-123.
    • (1976) Br Polymer J , vol.8 , pp. 118-123
    • Ng, C.1    Tighe, B.2
  • 18
    • 0001786961 scopus 로고
    • Measurement of oxygen transmissibility and permeability of hydrogel lenses and materials
    • Fatt I, Chaston J Measurement of oxygen transmissibility and permeability of hydrogel lenses and materials. ICLC 1982, 9(2):76-88.
    • (1982) ICLC , vol.9 , Issue.2 , pp. 76-88
    • Fatt, I.1    Chaston, J.2
  • 19
    • 0001871901 scopus 로고    scopus 로고
    • The oxygen performance of contemporary hydrogel contact lenses
    • Morgan PB, Efron N The oxygen performance of contemporary hydrogel contact lenses. Cont Lens Ant Eye 1998, 21(1):3-6.
    • (1998) Cont Lens Ant Eye , vol.21 , Issue.1 , pp. 3-6
    • Morgan, P.B.1    Efron, N.2
  • 20
    • 84882560639 scopus 로고
    • Now do we need"effective permeability"?
    • Fatt I Now do we need"effective permeability"?. Contax 1986, July:6-23.
    • (1986) Contax , vol.July , pp. 6-23
    • Fatt, I.1
  • 21
    • 15044364369 scopus 로고    scopus 로고
    • Modern contact lens materials: a clinical performance update
    • Jones L Modern contact lens materials: a clinical performance update. CL Spectrum 2002, 17(9):24-35.
    • (2002) CL Spectrum , vol.17 , Issue.9 , pp. 24-35
    • Jones, L.1
  • 22
    • 84990569156 scopus 로고
    • Epithelial erosions caused by thin high water content lenses
    • Holden B, Sweeney D, et al. Epithelial erosions caused by thin high water content lenses. Clin Exp Optom 1986, 69(3):103-107.
    • (1986) Clin Exp Optom , vol.69 , Issue.3 , pp. 103-107
    • Holden, B.1    Sweeney, D.2
  • 23
    • 0023877708 scopus 로고
    • Corneal desiccation staining with thin high water content contact lenses
    • Orsborn GN, Zantos SG Corneal desiccation staining with thin high water content contact lenses. CLAO J 1988, 14(2):81-85.
    • (1988) CLAO J , vol.14 , Issue.2 , pp. 81-85
    • Orsborn, G.N.1    Zantos, S.G.2
  • 24
    • 0021337467 scopus 로고
    • The minimum precorneal oxygen tension to avoid corneal edema
    • Holden B, Sweeney D, et al. The minimum precorneal oxygen tension to avoid corneal edema. Invest Ophthalmol Vis Sci 1984, 25:476-480.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 476-480
    • Holden, B.1    Sweeney, D.2
  • 25
    • 0032843148 scopus 로고    scopus 로고
    • Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia
    • Harvitt DM, Bonanno JA Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia. Optom Vis Sci 1999, 76(10):712-719.
    • (1999) Optom Vis Sci , vol.76 , Issue.10 , pp. 712-719
    • Harvitt, D.M.1    Bonanno, J.A.2
  • 26
    • 0032144577 scopus 로고    scopus 로고
    • On the relationship between soft contact lens oxygen transmissibility and induced limbal hyperaemia
    • Papas E On the relationship between soft contact lens oxygen transmissibility and induced limbal hyperaemia. Exp Eye Res 1998, 67(2):125-131.
    • (1998) Exp Eye Res , vol.67 , Issue.2 , pp. 125-131
    • Papas, E.1
  • 27
    • 33645097862 scopus 로고    scopus 로고
    • Clinical performance of silicone hydrogel lenses
    • Butterworth-Heinemann, Oxford, D. Sweeney (Ed.)
    • Sweeney D, du Toit R, et al. Clinical performance of silicone hydrogel lenses. Silicone Hydrogels: Continuous Wear Contact Lenses 2004, 164-216. Butterworth-Heinemann, Oxford. ed 2. D. Sweeney (Ed.).
    • (2004) Silicone Hydrogels: Continuous Wear Contact Lenses , pp. 164-216
    • Sweeney, D.1    du Toit, R.2
  • 28
    • 0019720290 scopus 로고
    • Apparent human corneal oxygen uptake rate
    • Larke J, Parrish S, et al. Apparent human corneal oxygen uptake rate. Am J Optom Physiol Opt 1981, 58(10):803-805.
    • (1981) Am J Optom Physiol Opt , vol.58 , Issue.10 , pp. 803-805
    • Larke, J.1    Parrish, S.2
  • 29
    • 0022504895 scopus 로고
    • Intersubject variability in corneal swelling response to anoxia
    • Efron N Intersubject variability in corneal swelling response to anoxia. Acta Ophthalmol (Copenh) 1986, 64(3):302-305.
    • (1986) Acta Ophthalmol (Copenh) , vol.64 , Issue.3 , pp. 302-305
    • Efron, N.1
  • 30
    • 0018397588 scopus 로고
    • Mechanism of gas transport through contact lenses
    • Refojo MF Mechanism of gas transport through contact lenses. J Am Optom Assoc 1979, 50(3):285-287.
    • (1979) J Am Optom Assoc , vol.50 , Issue.3 , pp. 285-287
    • Refojo, M.F.1
  • 31
    • 75149139339 scopus 로고    scopus 로고
    • Rigid lens materials
    • Butterworth-Heinemann, Oxford, N. Efron (Ed.)
    • Tighe B Rigid lens materials. Contact Lens Practice 2002, 153-162. Butterworth-Heinemann, Oxford. N. Efron (Ed.).
    • (2002) Contact Lens Practice , pp. 153-162
    • Tighe, B.1
  • 32
    • 21344435344 scopus 로고    scopus 로고
    • Silicone hydrogels: structure, properties and behaviour
    • Butterworth-Heinemann, Oxford, D. Sweeney (Ed.)
    • Tighe B Silicone hydrogels: structure, properties and behaviour. Silicone Hydrogels: Continuous Wear Contact Lenses 2004, 1-27. Butterworth-Heinemann, Oxford. D. Sweeney (Ed.).
    • (2004) Silicone Hydrogels: Continuous Wear Contact Lenses , pp. 1-27
    • Tighe, B.1
  • 33
    • 0018632322 scopus 로고
    • Use of silicone lenses in infants and children
    • Gurland JE Use of silicone lenses in infants and children. Ophthalmology 1979, 86(9):1599-1604.
    • (1979) Ophthalmology , vol.86 , Issue.9 , pp. 1599-1604
    • Gurland, J.E.1
  • 34
    • 0025900357 scopus 로고
    • Studies on initiation of silicone elastomer lens adhesion in vitro: binding before the indentation ring
    • Rae S, Huff J Studies on initiation of silicone elastomer lens adhesion in vitro: binding before the indentation ring. CLAO J 1991, 17(3):181-186.
    • (1991) CLAO J , vol.17 , Issue.3 , pp. 181-186
    • Rae, S.1    Huff, J.2
  • 35
    • 9644271637 scopus 로고
    • Identification and removal of deposits on polydimethylsilox-ane silicone elastomer lenses
    • Huth S, Wagner H Identification and removal of deposits on polydimethylsilox-ane silicone elastomer lenses. ICLC 1981, 7/8:19-26.
    • (1981) ICLC , pp. 19-26
    • Huth, S.1    Wagner, H.2
  • 36
    • 0035892432 scopus 로고    scopus 로고
    • Soft contact lens polymers: an evolution
    • Nicolson PC, Vogt J Soft contact lens polymers: an evolution. Biomaterials 2001, 22(24):3273-3283.
    • (2001) Biomaterials , vol.22 , Issue.24 , pp. 3273-3283
    • Nicolson, P.C.1    Vogt, J.2
  • 37
    • 0036095010 scopus 로고    scopus 로고
    • Porous structure of Purevision versus Focus Night & Day and conventional hydrogel contact lenses
    • Lopez-Alemany A, Compan V, et al. Porous structure of Purevision versus Focus Night & Day and conventional hydrogel contact lenses. J Biomed Mater Res (Appl Biomat) 2002, 63:319-325.
    • (2002) J Biomed Mater Res (Appl Biomat) , vol.63 , pp. 319-325
    • Lopez-Alemany, A.1    Compan, V.2
  • 38
    • 0031884657 scopus 로고    scopus 로고
    • Oxygen permeability of a new type of high Dk soft contact lens material
    • Alvord L, Court J, et al. Oxygen permeability of a new type of high Dk soft contact lens material. Optom Vis Sci 1998, 75(1):30-36.
    • (1998) Optom Vis Sci , vol.75 , Issue.1 , pp. 30-36
    • Alvord, L.1    Court, J.2
  • 39
    • 84902565336 scopus 로고    scopus 로고
    • Vinyl carbonate and vinyl carbamate contact lens materials.
    • Bausch & Lomb, US Patent No. 5
    • Bambury R, Seelye D. Vinyl carbonate and vinyl carbamate contact lens materials. Bausch & Lomb, US Patent No. 5,610,252.1997.
    • (1997) , vol.610 , pp. 252
    • Bambury, R.1    Seelye, D.2
  • 40
    • 4243800052 scopus 로고    scopus 로고
    • Silicone-based hydrogels for contact lens applications
    • Kunzler J Silicone-based hydrogels for contact lens applications. CL Spectrum 1999, 14(8 Suppl):9-11.
    • (1999) CL Spectrum , vol.14 , Issue.8 SUPPL , pp. 9-11
    • Kunzler, J.1
  • 41
    • 0000334707 scopus 로고    scopus 로고
    • Silicone hydrogels for contact lens applications
    • Grobe G, Kunzler J, et al. Silicone hydrogels for contact lens applications. Polymeric Materials Sci Eng 1999, 80:108-109.
    • (1999) Polymeric Materials Sci Eng , vol.80 , pp. 108-109
    • Grobe, G.1    Kunzler, J.2
  • 42
    • 10244225105 scopus 로고    scopus 로고
    • Soft lens materials
    • Butterworth-Heinemann, Oxford, N. Efron (Ed.)
    • Tighe B Soft lens materials. Contact Lens Practice 2002, 71-84. Butterworth-Heinemann, Oxford. N. Efron (Ed.).
    • (2002) Contact Lens Practice , pp. 71-84
    • Tighe, B.1
  • 43
    • 29644435060 scopus 로고    scopus 로고
    • A next generation silicone hydrogel lens for daily wear. Part 1-Material properties
    • Steffen R, Schnider C A next generation silicone hydrogel lens for daily wear. Part 1-Material properties. Optician 2004, 227(5954):23-25.
    • (2004) Optician , vol.227 , Issue.5954 , pp. 23-25
    • Steffen, R.1    Schnider, C.2
  • 44
    • 84882503073 scopus 로고    scopus 로고
    • A primer on contact lens materials
    • Snyder C A primer on contact lens materials. CL Spectrum 2004, 19(2):34-39.
    • (2004) CL Spectrum , vol.19 , Issue.2 , pp. 34-39
    • Snyder, C.1
  • 45
    • 40349109392 scopus 로고    scopus 로고
    • Finding the comfort zone
    • Steffen R, McCabe K Finding the comfort zone. CL Spectrum 2004, 13(3 Suppl):1-4.
    • (2004) CL Spectrum , vol.13 , Issue.3 SUPPL , pp. 1-4
    • Steffen, R.1    McCabe, K.2
  • 46
    • 25644449796 scopus 로고    scopus 로고
    • Masking astigmatism: CIBA Focus Night and Day vs Focus monthly
    • Edmondson L, Edmondson W, et al. Masking astigmatism: CIBA Focus Night and Day vs Focus monthly. Optom Vis Sci 2003, 80(12s):184.
    • (2003) Optom Vis Sci , vol.80 , Issue.12 S , pp. 184
    • Edmondson, L.1    Edmondson, W.2
  • 47
    • 0036799178 scopus 로고    scopus 로고
    • Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses
    • Dumbleton KA, Chalmers RL, et al. Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses. Optom Vis Sci 2002, 9(10):633-637.
    • (2002) Optom Vis Sci , vol.9 , Issue.10 , pp. 633-637
    • Dumbleton, K.A.1    Chalmers, R.L.2
  • 48
    • 64849086074 scopus 로고    scopus 로고
    • Silicone hydrogel lenses: fitting procedures and in-practice protocols for continuous wear lenses
    • Jones L, Dumbleton K Silicone hydrogel lenses: fitting procedures and in-practice protocols for continuous wear lenses. Optician 2002, 223(5840):37-45.
    • (2002) Optician , vol.223 , Issue.5840 , pp. 37-45
    • Jones, L.1    Dumbleton, K.2
  • 49
    • 0038340386 scopus 로고    scopus 로고
    • Continuous wear contact lens surface chemistry and wearability
    • discussion S57-39, S192-194.
    • Nicolson PC Continuous wear contact lens surface chemistry and wearability. Eye Cont Lens 2003, 29(1 Suppl):S30-S32. discussion S57-39, S192-194.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • Nicolson, P.C.1
  • 50
    • 32044456909 scopus 로고    scopus 로고
    • Extended wear ophthalmic lens.
    • CIBA Vision; CSIRO, US Patent No. 5
    • Nicolson P, Baron R, et al., Extended wear ophthalmic lens. CIBA Vision; CSIRO, US Patent No. 5,760,100.1998.
    • (1998) , vol.760 , pp. 100
    • Nicolson, P.1    Baron, R.2
  • 51
    • 0035869755 scopus 로고    scopus 로고
    • Evaluation of plasma polymer-coated contact lenses by electrochemical impedance spectroscopy
    • Weikart CM, Matsuzawa Y, et al. Evaluation of plasma polymer-coated contact lenses by electrochemical impedance spectroscopy. J Biomed Mater Res 2001, 54(4):597-607.
    • (2001) J Biomed Mater Res , vol.54 , Issue.4 , pp. 597-607
    • Weikart, C.M.1    Matsuzawa, Y.2
  • 52
    • 84882554656 scopus 로고    scopus 로고
    • Plasma surface treatment of silicone hydrogel contact lenses. Bausch & Lomb, US Patent No. 6
    • Valint PL Jr, Grobe GL 3rd, et al Plasma surface treatment of silicone hydrogel contact lenses. Bausch & Lomb, US Patent No. 6,193,369. 2001.
    • (2001) , vol.193 , pp. 369
    • Valint Jr., P.L.1    Grobe, G.L.2
  • 53
    • 2542427838 scopus 로고    scopus 로고
    • Drying methods for XPS analysis of Pure Vision, Focus Night&Day and conventional hydrogel contact lenses
    • Karlgard C, Sarkar D, et al. Drying methods for XPS analysis of Pure Vision, Focus Night&Day and conventional hydrogel contact lenses. Appl Surface Sci 2004, 230:106-114.
    • (2004) Appl Surface Sci , vol.230 , pp. 106-114
    • Karlgard, C.1    Sarkar, D.2
  • 54
    • 2942674904 scopus 로고    scopus 로고
    • Characterization of the surface of conventional hydrogel and silicone hydrogel contact lenses by time-of-flight secondary ion mass spectrometry
    • Maldonado-Codina C, Morgan PB, et al. Characterization of the surface of conventional hydrogel and silicone hydrogel contact lenses by time-of-flight secondary ion mass spectrometry. Optom Vis Sci 2004, 6:455-460. (81).
    • (2004) Optom Vis Sci , vol.6 , Issue.81 , pp. 455-460
    • Maldonado-Codina, C.1    Morgan, P.B.2
  • 55
    • 84882541234 scopus 로고    scopus 로고
    • The impact of contact lens care regimens on the in vitro wettability of conventional and silicone-hydrogel contact lens materials.
    • Invest Ophthalmol Vis Sci 2002;ARVO abstract No. 3097.
    • Jones L, Long J, et al., The impact of contact lens care regimens on the in vitro wettability of conventional and silicone-hydrogel contact lens materials. Invest Ophthalmol Vis Sci 2002;ARVO abstract No. 3097.
    • Jones, L.1    Long, J.2
  • 56
    • 1042265020 scopus 로고    scopus 로고
    • Wettability of silicone-hydrogel contact lenses in the presence of tear-film components
    • Cheng L, Muller SJ, et al. Wettability of silicone-hydrogel contact lenses in the presence of tear-film components. Curr Eye Res 2004, 28(2):93-108.
    • (2004) Curr Eye Res , vol.28 , Issue.2 , pp. 93-108
    • Cheng, L.1    Muller, S.J.2
  • 57
    • 0348219111 scopus 로고    scopus 로고
    • Local oxygen transmissibility of disposable contact lenses
    • Bruce A Local oxygen transmissibility of disposable contact lenses. Cont Lens Ant Eye 2003, 26(4):189-196.
    • (2003) Cont Lens Ant Eye , vol.26 , Issue.4 , pp. 189-196
    • Bruce, A.1
  • 58
    • 0034760598 scopus 로고    scopus 로고
    • Therapeutic use of Bausch & Lomb PureVision contact lenses
    • Lim L, Tan DT, et al. Therapeutic use of Bausch & Lomb PureVision contact lenses. CLAO J 2001, 27(4):179-185.
    • (2001) CLAO J , vol.27 , Issue.4 , pp. 179-185
    • Lim, L.1    Tan, D.T.2
  • 59
    • 1842485947 scopus 로고    scopus 로고
    • Therapeutic use of a lotrafilcon A silicone hydrogel soft contact lens as a bandage after LASEK surgery
    • Szaflik JP, Ambroziak AM, et al. Therapeutic use of a lotrafilcon A silicone hydrogel soft contact lens as a bandage after LASEK surgery. Eye Contact Lens 2004, 30(1):59-62.
    • (2004) Eye Contact Lens , vol.30 , Issue.1 , pp. 59-62
    • Szaflik, J.P.1    Ambroziak, A.M.2
  • 60
    • 1842538004 scopus 로고    scopus 로고
    • Therapeutic use of a silicone hydrogel contact lens in selected clinical cases
    • Ambroziak AM, Szaflik JP, et al. Therapeutic use of a silicone hydrogel contact lens in selected clinical cases. Eye Cont Lens 2004, 30(1):63-67.
    • (2004) Eye Cont Lens , vol.30 , Issue.1 , pp. 63-67
    • Ambroziak, A.M.1    Szaflik, J.P.2
  • 61
    • 0242286632 scopus 로고    scopus 로고
    • Therapeutic use of Focus Night & Day contact lenses
    • Kanpolat A, Ucakhan OO Therapeutic use of Focus Night & Day contact lenses. Cornea 2003, 22(8):726-734.
    • (2003) Cornea , vol.22 , Issue.8 , pp. 726-734
    • Kanpolat, A.1    Ucakhan, O.O.2
  • 62
    • 1842538031 scopus 로고    scopus 로고
    • A hyper-Dk piggyback contact lens system for keratoconus
    • O'Donnell C, Maldonado-Codina C A hyper-Dk piggyback contact lens system for keratoconus. Eye Cont Lens 2004, 30(1):44-48.
    • (2004) Eye Cont Lens , vol.30 , Issue.1 , pp. 44-48
    • O'Donnell, C.1    Maldonado-Codina, C.2
  • 63
    • 0030045815 scopus 로고    scopus 로고
    • The clinical presentation, prevalence and risk factors of focal corneal infiltrates in soft contact lens wearers
    • Cutter G, Chalmers R, et al. The clinical presentation, prevalence and risk factors of focal corneal infiltrates in soft contact lens wearers. CLAO J 1996, 22(1):30-37.
    • (1996) CLAO J , vol.22 , Issue.1 , pp. 30-37
    • Cutter, G.1    Chalmers, R.2
  • 64
    • 0037664608 scopus 로고    scopus 로고
    • Risk factors for corneal infiltrative events with 30-night continuous wear of silicone hydrogel lenses
    • discussion S166, S192-154
    • McNally JJ, Chalmers RL, et al. Risk factors for corneal infiltrative events with 30-night continuous wear of silicone hydrogel lenses. Eye Cont Lens 2003, 29(1 Suppl):S153-S156. discussion S166, S192-154.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • McNally, J.J.1    Chalmers, R.L.2
  • 65
    • 0035147289 scopus 로고    scopus 로고
    • A prospective study of contact lens wear in diabetes mellitus
    • O'Donnell C, Efron N, et al. A prospective study of contact lens wear in diabetes mellitus. Ophthalmic Physiol Opt 2001, 21(2):127-138.
    • (2001) Ophthalmic Physiol Opt , vol.21 , Issue.2 , pp. 127-138
    • O'Donnell, C.1    Efron, N.2
  • 66
    • 0029166361 scopus 로고
    • Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetics
    • Skaff A, Cullen AP, et al. Corneal swelling and recovery following wear of thick hydrogel contact lenses in insulin-dependent diabetics. Ophthalmic Physiol Opt 1995, 15(4):287-297.
    • (1995) Ophthalmic Physiol Opt , vol.15 , Issue.4 , pp. 287-297
    • Skaff, A.1    Cullen, A.P.2
  • 67
    • 0023968632 scopus 로고
    • A review of manifestations of diabetes mellitus in the anterior eye and cornea
    • Herse PR A review of manifestations of diabetes mellitus in the anterior eye and cornea. Am J Optom Physiol Opt 1988, 65(3):224-230.
    • (1988) Am J Optom Physiol Opt , vol.65 , Issue.3 , pp. 224-230
    • Herse, P.R.1
  • 68
    • 0026101754 scopus 로고
    • Corneal epithelium in diabetic patients
    • Tsubota K, Chiba K, et al. Corneal epithelium in diabetic patients. Cornea 1991, 10(2):156-160.
    • (1991) Cornea , vol.10 , Issue.2 , pp. 156-160
    • Tsubota, K.1    Chiba, K.2
  • 69
    • 0021708778 scopus 로고
    • Comparative bacteriology of chronic blepharitis
    • Dougherty JM, McCulley JP Comparative bacteriology of chronic blepharitis. Br J Ophthalmol 1984, 68(8):524-528.
    • (1984) Br J Ophthalmol , vol.68 , Issue.8 , pp. 524-528
    • Dougherty, J.M.1    McCulley, J.P.2
  • 70
    • 0026053375 scopus 로고
    • Lid flora in blepharitis
    • Groden LR, Murphy B, et al. Lid flora in blepharitis. Cornea 1991, 10(1):50-53.
    • (1991) Cornea , vol.10 , Issue.1 , pp. 50-53
    • Groden, L.R.1    Murphy, B.2
  • 71
    • 0018830694 scopus 로고
    • Meibomian gland dysfunction and contact lens intolerance
    • Korb DR, Henriquez AS Meibomian gland dysfunction and contact lens intolerance. J Am Optom Assoc 1980, 51(3):243-251.
    • (1980) J Am Optom Assoc , vol.51 , Issue.3 , pp. 243-251
    • Korb, D.R.1    Henriquez, A.S.2
  • 72
    • 0032806133 scopus 로고    scopus 로고
    • Giant papillary conjunctivitis in frequent replacement contact lens wearers: a retrospective study
    • Porazinski AD, Donshik PC Giant papillary conjunctivitis in frequent replacement contact lens wearers: a retrospective study. CLAO J 1999, 25(3):142-147.
    • (1999) CLAO J , vol.25 , Issue.3 , pp. 142-147
    • Porazinski, A.D.1    Donshik, P.C.2
  • 74
    • 0032964450 scopus 로고    scopus 로고
    • Colonization of hydrogel lenses with Streptococcus pneumoniae: risk of development of corneal infiltrates
    • Sankaridurg PR, Sharma S, et al. Colonization of hydrogel lenses with Streptococcus pneumoniae: risk of development of corneal infiltrates. Cornea 1999, 18(3):289-295.
    • (1999) Cornea , vol.18 , Issue.3 , pp. 289-295
    • Sankaridurg, P.R.1    Sharma, S.2
  • 75
    • 0032885174 scopus 로고    scopus 로고
    • Contact lens-induced peripheral ulcers with extended wear of disposable hydrogel lenses: histopathologic observations on the nature and type of corneal infiltrate
    • Holden BA, Reddy MK, et al. Contact lens-induced peripheral ulcers with extended wear of disposable hydrogel lenses: histopathologic observations on the nature and type of corneal infiltrate. Cornea 1999, 18(5):538-543.
    • (1999) Cornea , vol.18 , Issue.5 , pp. 538-543
    • Holden, B.A.1    Reddy, M.K.2
  • 76
    • 0030061258 scopus 로고    scopus 로고
    • Gram negative bacteria can induce contact lens related acute red eye (CLARE) responses
    • Holden B, La Hood D, et al. Gram negative bacteria can induce contact lens related acute red eye (CLARE) responses. CLAO J 1996, 22(1):47-52.
    • (1996) CLAO J , vol.22 , Issue.1 , pp. 47-52
    • Holden, B.1    La Hood, D.2
  • 77
    • 84882561470 scopus 로고    scopus 로고
    • Inflammation and infection and the effects of the closed eye
    • Willcox M Inflammation and infection and the effects of the closed eye. Optician 2000, 219(5733):39-42.
    • (2000) Optician , vol.219 , Issue.5733 , pp. 39-42
    • Willcox, M.1
  • 78
    • 0036739269 scopus 로고    scopus 로고
    • Adverse events with silicone hydrogel continuous wear
    • Dumbleton K Adverse events with silicone hydrogel continuous wear. Cont Lens Ant Eye 2002, 25:137-146.
    • (2002) Cont Lens Ant Eye , vol.25 , pp. 137-146
    • Dumbleton, K.1
  • 79
    • 0034496884 scopus 로고    scopus 로고
    • Severity and management of contact lens related complications with continuous wear of high Dk silicone hydrogel lenses
    • Dumbleton K, Fonn D, et al. Severity and management of contact lens related complications with continuous wear of high Dk silicone hydrogel lenses. Optom Vis Sci 2000, 77(12s):216.
    • (2000) Optom Vis Sci , vol.77 , Issue.12 S , pp. 216
    • Dumbleton, K.1    Fonn, D.2
  • 80
    • 33847163824 scopus 로고    scopus 로고
    • Adverse events and infections: Which ones and how many?
    • Butterworth-Heinemann, Oxford, D. Sweeney (Ed.)
    • Sankaridurg P, Holden B, et al. Adverse events and infections: Which ones and how many?. Silicone Hydrogels: Continuous Wear Contact Lenses 2004, 217-274. Butterworth-Heinemann, Oxford. ed 2. D. Sweeney (Ed.).
    • (2004) Silicone Hydrogels: Continuous Wear Contact Lenses , pp. 217-274
    • Sankaridurg, P.1    Holden, B.2
  • 81
    • 0038340339 scopus 로고    scopus 로고
    • Noninflammatory silicone hydrogel contact lens complications
    • discussion S190-181, S192-184.
    • Dumbleton K Noninflammatory silicone hydrogel contact lens complications. Eye Contact Lens 2003, 29(1 Suppl):S186-S189. discussion S190-181, S192-184.
    • (2003) Eye Contact Lens , vol.29 , Issue.1 SUPPL
    • Dumbleton, K.1
  • 82
    • 33846976596 scopus 로고    scopus 로고
    • A next generation silicone hydrogel lens for daily wear. Part 2-clinical performance
    • Schnider C, Steffen R A next generation silicone hydrogel lens for daily wear. Part 2-clinical performance. Optician 2004, 228(5958):20-24.
    • (2004) Optician , vol.228 , Issue.5958 , pp. 20-24
    • Schnider, C.1    Steffen, R.2
  • 83
    • 34547138931 scopus 로고    scopus 로고
    • Proposed practice guidelines for continuous contact lens wear
    • Brennan NA, Coles C, et al. Proposed practice guidelines for continuous contact lens wear. Clin Exp Optom 2001, 84(2):71-77.
    • (2001) Clin Exp Optom , vol.84 , Issue.2 , pp. 71-77
    • Brennan, N.A.1    Coles, C.2
  • 84
    • 0038678929 scopus 로고    scopus 로고
    • Microbial keratitis and vision loss with contact lenses
    • discussion S143-134, S192-134.
    • Holden BA, Sweeney DF, et al. Microbial keratitis and vision loss with contact lenses. Eye Cont Lens 2003, 29(1 Suppl):S131-S134. discussion S143-134, S192-134.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • Holden, B.A.1    Sweeney, D.F.2
  • 85
    • 0037664660 scopus 로고    scopus 로고
    • Effects of daily and overnight wear of hyper-oxygen transmissible rigid and silicone hydrogel lenses on bacterial binding to the corneal epithelium: 13-month clinical trials
    • discussion S26-29, S192-194.
    • Cavanagh HD, Ladage P, et al. Effects of daily and overnight wear of hyper-oxygen transmissible rigid and silicone hydrogel lenses on bacterial binding to the corneal epithelium: 13-month clinical trials. Eye Cont Lens 2003, 29(1 Suppl):S14-S16. discussion S26-29, S192-194.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • Cavanagh, H.D.1    Ladage, P.2
  • 86
    • 84882536263 scopus 로고
    • Patient education
    • J.B. Lippincott, Philadelphia, E.S. Bennett, B.A. Weissman (Eds.)
    • Yamane S, Paragina S Patient education. Clinical Contact Lens Practice 1991, 1-9. J.B. Lippincott, Philadelphia. E.S. Bennett, B.A. Weissman (Eds.).
    • (1991) Clinical Contact Lens Practice , pp. 1-9
    • Yamane, S.1    Paragina, S.2
  • 87
    • 84882557557 scopus 로고    scopus 로고
    • Silicone hydrogel lenses: follow-up and management
    • Dumbleton KA, Jones L Silicone hydrogel lenses: follow-up and management. Optician 2002, 223(5845):34-43.
    • (2002) Optician , vol.223 , Issue.5845 , pp. 34-43
    • Dumbleton, K.A.1    Jones, L.2
  • 88
    • 84882491714 scopus 로고    scopus 로고
    • Where do silicone hydrogels fit into everyday practice?
    • Butterworth-Heinemann, Oxford, D. Sweeney (Ed.)
    • Brennan N, Coles C, et al. Where do silicone hydrogels fit into everyday practice?. Silicone Hydrogels: Continuous Wear Contact Lenses 2004, 275-308. Butterworth-Heinemann, Oxford. ed 2. D. Sweeney (Ed.).
    • (2004) Silicone Hydrogels: Continuous Wear Contact Lenses , pp. 275-308
    • Brennan, N.1    Coles, C.2
  • 89
    • 0036913645 scopus 로고    scopus 로고
    • Asymptomatic corneal staining associated with the use of balafilcon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen
    • Jones L, MacDougall N, et al. Asymptomatic corneal staining associated with the use of balafilcon silicone-hydrogel contact lenses disinfected with a polyaminopropyl biguanide-preserved care regimen. Optom Vis Sci 2002, 79(12):753-761.
    • (2002) Optom Vis Sci , vol.79 , Issue.12 , pp. 753-761
    • Jones, L.1    MacDougall, N.2
  • 90
    • 33344478789 scopus 로고    scopus 로고
    • Understanding incompatibilities
    • Jones L Understanding incompatibilities. CL Spectrum 2004, 19(7 suppl):4-7.
    • (2004) CL Spectrum , vol.19 , Issue.7 SUPPL. , pp. 4-7
    • Jones, L.1
  • 91
    • 0342812437 scopus 로고    scopus 로고
    • Extended wear lenses
    • Butterworth, London, A. Phillips, L. Speedwell (Eds.)
    • Swarbrick H, Holden B Extended wear lenses. Contact Lenses 1997, 494-539. Butterworth, London. ed 4. A. Phillips, L. Speedwell (Eds.).
    • (1997) Contact Lenses , pp. 494-539
    • Swarbrick, H.1    Holden, B.2
  • 92
    • 0025126423 scopus 로고
    • Corneal hypoxia and hypercapnia during contact lens wear
    • Ang JH, Efron N Corneal hypoxia and hypercapnia during contact lens wear. Optom Vis Sci 1990, 67(7):512-521.
    • (1990) Optom Vis Sci , vol.67 , Issue.7 , pp. 512-521
    • Ang, J.H.1    Efron, N.2
  • 93
    • 0006865731 scopus 로고
    • Carbon dioxide permeability of contact lens materials
    • Ang J, Efron N Carbon dioxide permeability of contact lens materials. ICLC 1989, 16(2):48-57.
    • (1989) ICLC , vol.16 , Issue.2 , pp. 48-57
    • Ang, J.1    Efron, N.2
  • 94
    • 10644268757 scopus 로고    scopus 로고
    • The decay of Dk?
    • Morgan P, Brennan N The decay of Dk?. Optician 2004, 227(5937):27-33.
    • (2004) Optician , vol.227 , Issue.5937 , pp. 27-33
    • Morgan, P.1    Brennan, N.2
  • 95
    • 0021123317 scopus 로고
    • Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
    • Holden BA, Mertz GW Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984, 25(10):1161-1167.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , Issue.10 , pp. 1161-1167
    • Holden, B.A.1    Mertz, G.W.2
  • 97
    • 47149096447 scopus 로고    scopus 로고
    • Corneal staining
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Corneal staining. Contact Lens Complications 2004, 108-115. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 108-115
    • Efron, N.1
  • 99
    • 0017148525 scopus 로고
    • Clinical manifestations secondary to soft contact lens wear
    • Ruben M, Brown N, et al. Clinical manifestations secondary to soft contact lens wear. Br J Ophthalmol 1976, 60:529-531.
    • (1976) Br J Ophthalmol , vol.60 , pp. 529-531
    • Ruben, M.1    Brown, N.2
  • 100
    • 84990622711 scopus 로고
    • Ocular changes associated with continuous wear of contact lenses
    • Zantos S, Holden B Ocular changes associated with continuous wear of contact lenses. Aust J Optom 1978, 61:418-426.
    • (1978) Aust J Optom , vol.61 , pp. 418-426
    • Zantos, S.1    Holden, B.2
  • 101
    • 84882461916 scopus 로고    scopus 로고
    • Epithelial microcysts
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Epithelial microcysts. Contact Lens Complications 2004, 116-121. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 116-121
    • Efron, N.1
  • 102
    • 0026318647 scopus 로고
    • The significance of the microcyst response: a review
    • Holden B, Sweeney D The significance of the microcyst response: a review. Optom Vis Sci 1991, 68(9):703-707.
    • (1991) Optom Vis Sci , vol.68 , Issue.9 , pp. 703-707
    • Holden, B.1    Sweeney, D.2
  • 103
    • 0035406583 scopus 로고    scopus 로고
    • Microcysts: clinical significance and differential diagnosis
    • Keay L, Jalbert I, et al. Microcysts: clinical significance and differential diagnosis. Optometry 2001, 72(7):452-460.
    • (2001) Optometry , vol.72 , Issue.7 , pp. 452-460
    • Keay, L.1    Jalbert, I.2
  • 104
    • 0034351442 scopus 로고    scopus 로고
    • Microcyst response to high Dk/t silicone hydrogel contact lenses
    • Keay L, Sweeney DF, et al. Microcyst response to high Dk/t silicone hydrogel contact lenses. Optom Vis Sci 2000, 77(11):582-585.
    • (2000) Optom Vis Sci , vol.77 , Issue.11 , pp. 582-585
    • Keay, L.1    Sweeney, D.F.2
  • 105
    • 0000050698 scopus 로고    scopus 로고
    • High Dk silicone hydrogels do not induce an epithelial microcyst response
    • Keay L, Sweeney D, et al. High Dk silicone hydrogels do not induce an epithelial microcyst response. Optom Vis Sci 1999, 76(12s):213.
    • (1999) Optom Vis Sci , vol.76 , Issue.12 S , pp. 213
    • Keay, L.1    Sweeney, D.2
  • 106
    • 0035106234 scopus 로고    scopus 로고
    • Hypoxic effects on the anterior eye of high-Dk soft contact lens wearers are negligible
    • Covey M, Sweeney DF, et al. Hypoxic effects on the anterior eye of high-Dk soft contact lens wearers are negligible. Optom Vis Sci 2001, 78(2):95-99.
    • (2001) Optom Vis Sci , vol.78 , Issue.2 , pp. 95-99
    • Covey, M.1    Sweeney, D.F.2
  • 107
    • 0036560595 scopus 로고    scopus 로고
    • The ocular response to extended wear of a high Dk silicone hydrogel contact lens
    • Fonn D, MacDonald KE, et al. The ocular response to extended wear of a high Dk silicone hydrogel contact lens. Clin Exp Optom 2002, 85(3):176-182.
    • (2002) Clin Exp Optom , vol.85 , Issue.3 , pp. 176-182
    • Fonn, D.1    MacDonald, K.E.2
  • 108
    • 0019731768 scopus 로고
    • Stromal lactate accumulation can account for corneal edema osmotically following epithelial hypoxia in the rabbit
    • Klyce S Stromal lactate accumulation can account for corneal edema osmotically following epithelial hypoxia in the rabbit. J Physiol 1981, 321:49-64.
    • (1981) J Physiol , vol.321 , pp. 49-64
    • Klyce, S.1
  • 109
    • 0020660052 scopus 로고
    • Corneal swelling response to contact lenses worn under extended wear conditions
    • Holden BA, Mertz GW, et al. Corneal swelling response to contact lenses worn under extended wear conditions. Invest Ophthalmol Vis Sci 1983, 24(2):218-226.
    • (1983) Invest Ophthalmol Vis Sci , vol.24 , Issue.2 , pp. 218-226
    • Holden, B.A.1    Mertz, G.W.2
  • 110
    • 0032742403 scopus 로고    scopus 로고
    • Sympathetic swelling response of the control eye to soft lenses in the other eye
    • Fonn D, du Toit R, et al. Sympathetic swelling response of the control eye to soft lenses in the other eye. Invest Ophthalmol Vis Sci 1999, 40(13):3116-3121.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , Issue.13 , pp. 3116-3121
    • Fonn, D.1    du Toit, R.2
  • 111
    • 6644221287 scopus 로고
    • Striae and folds as indicators of corneal edema
    • La Hood D, Grant T Striae and folds as indicators of corneal edema. Optom Vis Sci 1990, 67(12s):196.
    • (1990) Optom Vis Sci , vol.67 , Issue.12 S , pp. 196
    • La Hood, D.1    Grant, T.2
  • 112
    • 34248554288 scopus 로고    scopus 로고
    • Stromal edema
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Stromal edema. Contact Lens Complications 2004, 133-140. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 133-140
    • Efron, N.1
  • 113
    • 0030955386 scopus 로고    scopus 로고
    • High-oxygen-transmissibility soft contact lenses do not induce limbal hyperaemia
    • Papas EB, Vajdic CM, et al. High-oxygen-transmissibility soft contact lenses do not induce limbal hyperaemia. Curr Eye Res 1997, 16(9):942-948.
    • (1997) Curr Eye Res , vol.16 , Issue.9 , pp. 942-948
    • Papas, E.B.1    Vajdic, C.M.2
  • 114
    • 0035053132 scopus 로고    scopus 로고
    • Vascular response to extended wear of hydrogel lenses with high and low oxygen permeability
    • Dumbleton KA, Chalmers RL, et al. Vascular response to extended wear of hydrogel lenses with high and low oxygen permeability. Optom Vis Sci 2001, 78(3):147-151.
    • (2001) Optom Vis Sci , vol.78 , Issue.3 , pp. 147-151
    • Dumbleton, K.A.1    Chalmers, R.L.2
  • 115
    • 0034917218 scopus 로고    scopus 로고
    • Recovery from hyperemia after overnight wear of low and high transmissibility hydrogel lenses
    • du Toit R, Simpson TL, et al. Recovery from hyperemia after overnight wear of low and high transmissibility hydrogel lenses. Curr Eye Res 2001, 22(1):68-73.
    • (2001) Curr Eye Res , vol.22 , Issue.1 , pp. 68-73
    • du Toit, R.1    Simpson, T.L.2
  • 116
    • 84882502098 scopus 로고    scopus 로고
    • Corneal vascularization
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Corneal vascularization. Contact Lens Complications 2004, 153-161. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 153-161
    • Efron, N.1
  • 117
    • 0036562698 scopus 로고    scopus 로고
    • Comparative clinical performance of two silicone hydrogel contact lenses for continuous wear
    • Morgan PB, Efron N Comparative clinical performance of two silicone hydrogel contact lenses for continuous wear. Clin Exp Optom 2002, 85(3):183-192.
    • (2002) Clin Exp Optom , vol.85 , Issue.3 , pp. 183-192
    • Morgan, P.B.1    Efron, N.2
  • 118
    • 0001394456 scopus 로고
    • Corneal endothelial polymegethism associated with extended wear
    • Schoessler J Corneal endothelial polymegethism associated with extended wear. ICLC 1983, 10(3):148-155.
    • (1983) ICLC , vol.10 , Issue.3 , pp. 148-155
    • Schoessler, J.1
  • 119
    • 77956231423 scopus 로고    scopus 로고
    • Endothelial polymegethism
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Endothelial polymegethism. Contact Lens Complications 2004, 216-222. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 216-222
    • Efron, N.1
  • 120
    • 0026756652 scopus 로고
    • Corneal exhaustion syndrome with long-term wear of contact lenses
    • Sweeney D Corneal exhaustion syndrome with long-term wear of contact lenses. Optom Vis Sci 1992, 69(8):601-608.
    • (1992) Optom Vis Sci , vol.69 , Issue.8 , pp. 601-608
    • Sweeney, D.1
  • 121
    • 0022201849 scopus 로고
    • Effects of long-term extended contact lens wear on the human cornea
    • Holden BA, Sweeney DF, et al. Effects of long-term extended contact lens wear on the human cornea. Invest Ophthalmol Vis Sci 1985, 26(11):1489-1501.
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , Issue.11 , pp. 1489-1501
    • Holden, B.A.1    Sweeney, D.F.2
  • 122
    • 0024263979 scopus 로고
    • Endothelial morphologic features and function after long-term extended wear of contact lenses
    • Carlson KH, Bourne WM Endothelial morphologic features and function after long-term extended wear of contact lenses. Arch Ophthalmol 1988, 106(12):1677-1679.
    • (1988) Arch Ophthalmol , vol.106 , Issue.12 , pp. 1677-1679
    • Carlson, K.H.1    Bourne, W.M.2
  • 123
    • 0024506288 scopus 로고
    • A morphologic and fluorophotometric analysis of the corneal endothelium in long-term extended wear soft contact lens wearers
    • Dutt RM, Stocker EG, et al. A morphologic and fluorophotometric analysis of the corneal endothelium in long-term extended wear soft contact lens wearers. CLAO J 1989, 15(2):121-123.
    • (1989) CLAO J , vol.15 , Issue.2 , pp. 121-123
    • Dutt, R.M.1    Stocker, E.G.2
  • 124
    • 9244260364 scopus 로고
    • Observation of corneal endothelial response to hydrogel lenses by non-contact specular microscope
    • Hamano H, Watanabe K, et al. Observation of corneal endothelial response to hydrogel lenses by non-contact specular microscope. J Jpn Cont Lens Soc 1993, 35:140-145.
    • (1993) J Jpn Cont Lens Soc , vol.35 , pp. 140-145
    • Hamano, H.1    Watanabe, K.2
  • 125
    • 0038825097 scopus 로고    scopus 로고
    • Corneal endothelial morphology results in the Menicon Z 30-day continuous-wear contact lens clinical trial
    • (29)
    • Barr JT, Pall B, et al. Corneal endothelial morphology results in the Menicon Z 30-day continuous-wear contact lens clinical trial. Eye Cont Lens 2003, 1:14-16. (29).
    • (2003) Eye Cont Lens , vol.1 , pp. 14-16
    • Barr, J.T.1    Pall, B.2
  • 126
    • 0018821968 scopus 로고
    • Extended wear of Hydrocurve II soft contact lenses
    • Miller J, Coon L, et al. Extended wear of Hydrocurve II soft contact lenses. J Am Optom Assoc 1980, 51:225-232.
    • (1980) J Am Optom Assoc , vol.51 , pp. 225-232
    • Miller, J.1    Coon, L.2
  • 127
    • 0032761030 scopus 로고    scopus 로고
    • Changes in myopic refractive error with nine months' extended wear of hydrogel lenses with high and low oxygen permeability
    • Dumbleton KA, Chalmers RL, et al. Changes in myopic refractive error with nine months' extended wear of hydrogel lenses with high and low oxygen permeability. Optom Vis Sci 1999, 76(12):845-849.
    • (1999) Optom Vis Sci , vol.76 , Issue.12 , pp. 845-849
    • Dumbleton, K.A.1    Chalmers, R.L.2
  • 128
    • 0002668133 scopus 로고    scopus 로고
    • A clinical look at a silicone hydrogel extended wear lens
    • McNally J, McKenney CD A clinical look at a silicone hydrogel extended wear lens. CL Spectrum 2002, 17(1):38-41.
    • (2002) CL Spectrum , vol.17 , Issue.1 , pp. 38-41
    • McNally, J.1    McKenney, C.D.2
  • 129
    • 4143152915 scopus 로고    scopus 로고
    • Changes in myopia with low-Dk hydrogel and high-Dk silicone hydrogel extended wear
    • Jalbert I, Stretton S, et al. Changes in myopia with low-Dk hydrogel and high-Dk silicone hydrogel extended wear. Optom Vis Sci 2004, 81(8):591-596.
    • (2004) Optom Vis Sci , vol.81 , Issue.8 , pp. 591-596
    • Jalbert, I.1    Stretton, S.2
  • 130
    • 0000916443 scopus 로고    scopus 로고
    • A clinical comparison of limbal and paralimbal superior epithelial arcuate lesions (SEALs) in high Dk EW
    • O'Hare N, Naduvilath T, et al. A clinical comparison of limbal and paralimbal superior epithelial arcuate lesions (SEALs) in high Dk EW. Invest Ophthalmol Vis Sci 2001, 42(4):s595.
    • (2001) Invest Ophthalmol Vis Sci , vol.42 , Issue.4
    • O'Hare, N.1    Naduvilath, T.2
  • 131
    • 0035105094 scopus 로고    scopus 로고
    • Superior epithelial arcuate lesions with soft contact lens wear
    • Holden BA, Stephenson A, et al. Superior epithelial arcuate lesions with soft contact lens wear. Optom Vis Sci 2001, 78(1):9-12.
    • (2001) Optom Vis Sci , vol.78 , Issue.1 , pp. 9-12
    • Holden, B.A.1    Stephenson, A.2
  • 132
    • 0034907207 scopus 로고    scopus 로고
    • Seven-day extended wear and 30-day continuous wear of high oxygen transmissibility soft silicone hydrogel contact lenses: a randomized 1-year study of 504 patients
    • Nilsson SE Seven-day extended wear and 30-day continuous wear of high oxygen transmissibility soft silicone hydrogel contact lenses: a randomized 1-year study of 504 patients. CLAO J 2001, 27(3):125-136.
    • (2001) CLAO J , vol.27 , Issue.3 , pp. 125-136
    • Nilsson, S.E.1
  • 133
    • 0000711324 scopus 로고    scopus 로고
    • Six months of in-practice experience with a high Dk Lotrafilcon A soft contact lens
    • Long B, Robirds S, et al. Six months of in-practice experience with a high Dk Lotrafilcon A soft contact lens. Cont Lens Ant Eye 2000, 23(4):112-118.
    • (2000) Cont Lens Ant Eye , vol.23 , Issue.4 , pp. 112-118
    • Long, B.1    Robirds, S.2
  • 134
    • 0035139743 scopus 로고    scopus 로고
    • Practical experience with a high Dk lotrafilcon A fluorosilicone hydrogel extended wear contact lens in Spain
    • (27)
    • Montero Iruzubieta J, Nebot Ripoll JR, et al. Practical experience with a high Dk lotrafilcon A fluorosilicone hydrogel extended wear contact lens in Spain. CLAO J 2001, 1:41-46. (27).
    • (2001) CLAO J , vol.1 , pp. 41-46
    • Montero Iruzubieta, J.1    Nebot Ripoll, J.R.2
  • 135
    • 0034767740 scopus 로고    scopus 로고
    • Epithelial split associated with wear of a silicone hydrogel contact lens
    • Jalbert I, Sweeney DF, et al. Epithelial split associated with wear of a silicone hydrogel contact lens. CLAO J 2001, 27(4):231-233.
    • (2001) CLAO J , vol.27 , Issue.4 , pp. 231-233
    • Jalbert, I.1    Sweeney, D.F.2
  • 136
    • 38249001355 scopus 로고
    • A hypothesis for the aetiology of soft contact lens-induced superior arcuate keratopathy
    • Young G, Mirejovsky D A hypothesis for the aetiology of soft contact lens-induced superior arcuate keratopathy. ICLC 1993, 20(9/10):177-179.
    • (1993) ICLC , vol.20 , Issue.9-10 , pp. 177-179
    • Young, G.1    Mirejovsky, D.2
  • 137
    • 0002618842 scopus 로고    scopus 로고
    • Superior epithelial arcuate lesions (SEALs): a case control study
    • O'Hare N, Naduvilath T, et al. Superior epithelial arcuate lesions (SEALs): a case control study. Invest Ophthalmol Vis Sci 2000, 41(4):s386.
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , Issue.4
    • O'Hare, N.1    Naduvilath, T.2
  • 138
    • 0033384178 scopus 로고    scopus 로고
    • Giant papillary conjunctivitis in frequent-replacement contact lens wearers: a retrospective study
    • discussion 216-220.
    • Donshik PC, Porazinski AD Giant papillary conjunctivitis in frequent-replacement contact lens wearers: a retrospective study. Trans Am Ophthalmol Soc 1999, 97:205-216. discussion 216-220.
    • (1999) Trans Am Ophthalmol Soc , vol.97 , pp. 205-216
    • Donshik, P.C.1    Porazinski, A.D.2
  • 139
    • 0030939204 scopus 로고    scopus 로고
    • Prospective trial of daily and extended wear disposable contact lenses
    • Levy B, McNamara N, et al. Prospective trial of daily and extended wear disposable contact lenses. Cornea 1997, 16(3):274-276.
    • (1997) Cornea , vol.16 , Issue.3 , pp. 274-276
    • Levy, B.1    McNamara, N.2
  • 140
    • 17344386189 scopus 로고
    • Giant papillary conjunctivitis
    • Allansmith MR Giant papillary conjunctivitis. J Am Optom Assoc 1990, 61(6 Suppl):S42-S46.
    • (1990) J Am Optom Assoc , vol.61 , Issue.6 SUPPL
    • Allansmith, M.R.1
  • 141
    • 0036559640 scopus 로고    scopus 로고
    • General and local contact lens induced papillary conjunctivitis (CLPC)
    • Skotnitsky C, Sankaridurg PR, et al. General and local contact lens induced papillary conjunctivitis (CLPC). Clin Exp Optom 2002, 85(3):193-197.
    • (2002) Clin Exp Optom , vol.85 , Issue.3 , pp. 193-197
    • Skotnitsky, C.1    Sankaridurg, P.R.2
  • 142
    • 2942657473 scopus 로고    scopus 로고
    • Comparison of the performance of 6- or 30-night extended wear schedules with silicone hydrogel lenses over 3 years
    • Stern J, Wong R, et al. Comparison of the performance of 6- or 30-night extended wear schedules with silicone hydrogel lenses over 3 years. Optom Vis Sci 2004, 81(6):398-406.
    • (2004) Optom Vis Sci , vol.81 , Issue.6 , pp. 398-406
    • Stern, J.1    Wong, R.2
  • 143
    • 64849086074 scopus 로고    scopus 로고
    • Fitting procedures and in-practice protocols for continuous wear lenses
    • Jones L, Dumbleton K Fitting procedures and in-practice protocols for continuous wear lenses. Optician 2002, 223(5840):37-45.
    • (2002) Optician , vol.223 , Issue.5840 , pp. 37-45
    • Jones, L.1    Dumbleton, K.2
  • 144
    • 0025567936 scopus 로고
    • Some unusual nonallergic causes of giant papillary conjunctivitis
    • discussion 349-351.
    • Friedlaender MH Some unusual nonallergic causes of giant papillary conjunctivitis. Trans Am Ophthalmol Soc 1990, 88:343-349. discussion 349-351.
    • (1990) Trans Am Ophthalmol Soc , vol.88 , pp. 343-349
    • Friedlaender, M.H.1
  • 145
    • 0019352796 scopus 로고
    • Giant papillary conjunctivitis after keratoplasty
    • Sugar A, Meyer RF Giant papillary conjunctivitis after keratoplasty. Am J Ophthalmol 1981, 91(2):239-242.
    • (1981) Am J Ophthalmol , vol.91 , Issue.2 , pp. 239-242
    • Sugar, A.1    Meyer, R.F.2
  • 146
    • 0023216489 scopus 로고
    • Pseudomonas ulcers following the patching of corneal abrasions associated with contact lens wear
    • Clemons C, Cohen E, et al. Pseudomonas ulcers following the patching of corneal abrasions associated with contact lens wear. CLAO J 1987, 13:161-164.
    • (1987) CLAO J , vol.13 , pp. 161-164
    • Clemons, C.1    Cohen, E.2
  • 147
    • 0033744673 scopus 로고    scopus 로고
    • Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses
    • Dumbleton K, Jones L, et al. Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses. CLAO J 2000, 26(4):186-192.
    • (2000) CLAO J , vol.26 , Issue.4 , pp. 186-192
    • Dumbleton, K.1    Jones, L.2
  • 148
    • 0033998789 scopus 로고    scopus 로고
    • Epithelial inclusions in association with mucin ball development in high-oxygen permeability hydrogel lenses
    • Pritchard N, Jones L, et al. Epithelial inclusions in association with mucin ball development in high-oxygen permeability hydrogel lenses. Optom Vis Sci 2000, 77(2):68-72.
    • (2000) Optom Vis Sci , vol.77 , Issue.2 , pp. 68-72
    • Pritchard, N.1    Jones, L.2
  • 149
    • 0036921768 scopus 로고    scopus 로고
    • An evaluation of mucin balls associated with high-DK silicone-hydrogel contact lens wear
    • Craig JP, Sherwin T, et al. An evaluation of mucin balls associated with high-DK silicone-hydrogel contact lens wear. Adv Exp Med Biol 2002, 506(Pt B):917-923.
    • (2002) Adv Exp Med Biol , vol.506 , Issue.PT B , pp. 917-923
    • Craig, J.P.1    Sherwin, T.2
  • 150
    • 0036781851 scopus 로고    scopus 로고
    • Spherical indentations of human and rabbit corneal epithelium following extended contact lens wear
    • Ladage PM, Petroll WM, et al. Spherical indentations of human and rabbit corneal epithelium following extended contact lens wear. CLAO J 2002, 28(4):177-180.
    • (2002) CLAO J , vol.28 , Issue.4 , pp. 177-180
    • Ladage, P.M.1    Petroll, W.M.2
  • 151
    • 0037396754 scopus 로고    scopus 로고
    • Mucin balls with wear of conventional and silicone hydrogel contact lenses
    • Tan J, Keay L, et al. Mucin balls with wear of conventional and silicone hydrogel contact lenses. Optom Vis Sci 2003, 80(4):291-297.
    • (2003) Optom Vis Sci , vol.80 , Issue.4 , pp. 291-297
    • Tan, J.1    Keay, L.2
  • 152
    • 0242286629 scopus 로고    scopus 로고
    • Clinical appearance and microscopic analysis of mucin balls associated with contact lens wear
    • Millar TJ, Papas EB, et al. Clinical appearance and microscopic analysis of mucin balls associated with contact lens wear. Cornea 2003, 22(8):740-745.
    • (2003) Cornea , vol.22 , Issue.8 , pp. 740-745
    • Millar, T.J.1    Papas, E.B.2
  • 153
    • 0037310973 scopus 로고    scopus 로고
    • In vivo confocal microscopy of the human cornea
    • Jalbert I, Stapleton F, et al. In vivo confocal microscopy of the human cornea. Br J Ophthalmol 2003, 87(2):225-236.
    • (2003) Br J Ophthalmol , vol.87 , Issue.2 , pp. 225-236
    • Jalbert, I.1    Stapleton, F.2
  • 154
    • 0036135686 scopus 로고    scopus 로고
    • 2 transmissible contact lenses on bacterial binding and corneal epithelium: a 1-year clinical trial
    • 2 transmissible contact lenses on bacterial binding and corneal epithelium: a 1-year clinical trial. Ophthalmology 2002, 109(1):27-39.
    • (2002) Ophthalmology , vol.109 , Issue.1 , pp. 27-39
    • Ren, D.H.1    Yamamoto, K.2
  • 155
    • 0042574490 scopus 로고    scopus 로고
    • Contact lens induced peripheral ulcers during hydrogel contact lens wear
    • Grant T, Chong MS, et al. Contact lens induced peripheral ulcers during hydrogel contact lens wear. CLAO J 1998, 24(3):145-151.
    • (1998) CLAO J , vol.24 , Issue.3 , pp. 145-151
    • Grant, T.1    Chong, M.S.2
  • 156
    • 0038340348 scopus 로고    scopus 로고
    • Differential diagnosis of microbial keratitis and contact lens-induced peripheral ulcer
    • discussion S83-64, S192-194.
    • Aasuri MK, Venkata N, et al. Differential diagnosis of microbial keratitis and contact lens-induced peripheral ulcer. Eye Cont Lens 2003, (1 Suppl):S60-S62. discussion S83-64, S192-194.
    • (2003) Eye Cont Lens , Issue.1 SUPPL
    • Aasuri, M.K.1    Venkata, N.2
  • 157
    • 0034513654 scopus 로고    scopus 로고
    • Atypical presentation of contact lens induced peripheral ulcers-multiple focal infiltrates
    • Sweeney DF, Sankaridurg P, et al. Atypical presentation of contact lens induced peripheral ulcers-multiple focal infiltrates. Optom Vis Sci 2000, 77(12s):164.
    • (2000) Optom Vis Sci , vol.77 , Issue.12 S , pp. 164
    • Sweeney, D.F.1    Sankaridurg, P.2
  • 158
    • 0001196973 scopus 로고
    • Culture negative peripheral ulcers are associated with bacterial contamination of contact lenses
    • Willcox M, Sweeney D, et al. Culture negative peripheral ulcers are associated with bacterial contamination of contact lenses. Invest Ophthalmol Vis Sci 1995, 36(4):S152.
    • (1995) Invest Ophthalmol Vis Sci , vol.36 , Issue.4
    • Willcox, M.1    Sweeney, D.2
  • 159
    • 0033988698 scopus 로고    scopus 로고
    • Isolation of Staphylococcus aureus from a contact lens at the time of a contact lens-induced peripheral ulcer: case report
    • Jalbert I, Willcox MD, et al. Isolation of Staphylococcus aureus from a contact lens at the time of a contact lens-induced peripheral ulcer: case report. Cornea 2000, 19(1):116-120.
    • (2000) Cornea , vol.19 , Issue.1 , pp. 116-120
    • Jalbert, I.1    Willcox, M.D.2
  • 160
    • 0033821157 scopus 로고    scopus 로고
    • Staphylococcus aureus causes acute inflammatory episodes in the cornea during contact lens wear
    • Wu PZ, Thakur A, et al. Staphylococcus aureus causes acute inflammatory episodes in the cornea during contact lens wear. Clin Exp Ophthalmol 2000, 28(3):194-196.
    • (2000) Clin Exp Ophthalmol , vol.28 , Issue.3 , pp. 194-196
    • Wu, P.Z.1    Thakur, A.2
  • 161
    • 31944437045 scopus 로고    scopus 로고
    • Contact lens induced peripheral ulcers (CLPU) are produced by an alpha-toxin deficient mutant of Staphylococcus aureus.
    • Hume E, Wu P, et al. Contact lens induced peripheral ulcers (CLPU) are produced by an alpha-toxin deficient mutant of Staphylococcus aureus. Invest Ophthalmol Vis Sci 2001, 42(4):s593.
    • (2001) Invest Ophthalmol Vis Sci , vol.42 , Issue.4
    • Hume, E.1    Wu, P.2
  • 162
    • 0038158079 scopus 로고    scopus 로고
    • The causes of and cures for contact lens-induced peripheral ulcer
    • discussion S83-64, S192-194.
    • Wu P, Stapleton F, et al. The causes of and cures for contact lens-induced peripheral ulcer. Eye Cont Lens 2003, 29(1 Suppl):S63-S66. discussion S83-64, S192-194.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • Wu, P.1    Stapleton, F.2
  • 163
    • 0010492318 scopus 로고    scopus 로고
    • Inflammatory adverse event rates over 3 years with silicone hydrogel lenses
    • Sweeney DF, Stern J, et al. Inflammatory adverse event rates over 3 years with silicone hydrogel lenses. Invest Ophthalmol Vis Sci 2002, 43(4):40.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , Issue.4 , pp. 40
    • Sweeney, D.F.1    Stern, J.2
  • 164
    • 0010498123 scopus 로고    scopus 로고
    • Some potential pathogenic traits of gram-negative bacteria isolated during ocular inflammation and infections
    • Willcox M, Thakur A, et al. Some potential pathogenic traits of gram-negative bacteria isolated during ocular inflammation and infections. Clin Exp Optom 1998, 81(2):56-62.
    • (1998) Clin Exp Optom , vol.81 , Issue.2 , pp. 56-62
    • Willcox, M.1    Thakur, A.2
  • 165
    • 0032819846 scopus 로고    scopus 로고
    • Differences in the pathogenesis of bacteria isolated from contact-lens-induced infiltrative conditions
    • Willcox MD, Hume EB Differences in the pathogenesis of bacteria isolated from contact-lens-induced infiltrative conditions. Aust N Z J Ophthalmol 1999, 27(3-4):231-233.
    • (1999) Aust N Z J Ophthalmol , vol.27 , Issue.3-4 , pp. 231-233
    • Willcox, M.D.1    Hume, E.B.2
  • 166
    • 0030092981 scopus 로고    scopus 로고
    • Gram negative bacteria and contact lens induced acute red eye
    • Sankaridurg PR, Vuppala N, et al. Gram negative bacteria and contact lens induced acute red eye. Indian J Ophthalmol 1996, 44(1):29-32.
    • (1996) Indian J Ophthalmol , vol.44 , Issue.1 , pp. 29-32
    • Sankaridurg, P.R.1    Vuppala, N.2
  • 167
    • 0034462898 scopus 로고    scopus 로고
    • Bacterial colonization of disposable soft contact lenses is greater during corneal infiltrative events than during asymptomatic extended lens wear
    • Sankaridurg PR, Sharma S, et al. Bacterial colonization of disposable soft contact lenses is greater during corneal infiltrative events than during asymptomatic extended lens wear. J Clin Microbiol 2000, 38(12):4420-4424.
    • (2000) J Clin Microbiol , vol.38 , Issue.12 , pp. 4420-4424
    • Sankaridurg, P.R.1    Sharma, S.2
  • 168
    • 9544255677 scopus 로고    scopus 로고
    • Haemophilus influenzae adherent to contact lenses associated with production of acute ocular inflammation
    • Sankaridurg PR, Willcox MD, et al. Haemophilus influenzae adherent to contact lenses associated with production of acute ocular inflammation. J Clin Microbiol 1996, 34(10):2426-2431.
    • (1996) J Clin Microbiol , vol.34 , Issue.10 , pp. 2426-2431
    • Sankaridurg, P.R.1    Willcox, M.D.2
  • 169
    • 84882489073 scopus 로고    scopus 로고
    • Sterile keratitis
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Sterile keratitis. Contact Lens Complications 2004, 162-174. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 162-174
    • Efron, N.1
  • 170
    • 33344478325 scopus 로고    scopus 로고
    • Inflammation and infection and the effects of the closed eye
    • Butterworth-Heinemann, Oxford, D. Sweeney (Ed.)
    • Willcox M, Sankaridurg P, et al. Inflammation and infection and the effects of the closed eye. Silicone hydrogels: continuous wear contact lenses 2004, 90-125. Butterworth-Heinemann, Oxford. D. Sweeney (Ed.).
    • (2004) Silicone hydrogels: continuous wear contact lenses , pp. 90-125
    • Willcox, M.1    Sankaridurg, P.2
  • 171
    • 84882480978 scopus 로고
    • Three questions to ask when you see infiltrates
    • Townsend W Three questions to ask when you see infiltrates. CL Spectrum 1994, 9(1):53.
    • (1994) CL Spectrum , vol.9 , Issue.1 , pp. 53
    • Townsend, W.1
  • 172
    • 0000964692 scopus 로고
    • Management of corneal infiltrates in extended-wear contact lens patients
    • Zantos S Management of corneal infiltrates in extended-wear contact lens patients. ICLC 1984, 11:604-610.
    • (1984) ICLC , vol.11 , pp. 604-610
    • Zantos, S.1
  • 173
    • 0025870491 scopus 로고
    • Contact lenses and other risk factors in microbial keratitis
    • Dart JK, Stapleton F, et al. Contact lenses and other risk factors in microbial keratitis. Lancet 1991, 338(8768):650-653.
    • (1991) Lancet , vol.338 , Issue.8768 , pp. 650-653
    • Dart, J.K.1    Stapleton, F.2
  • 174
    • 0037784221 scopus 로고    scopus 로고
    • Bacterial keratitis: predisposing factors, clinical and microbiological review of 300 cases
    • Bourcier T, Thomas F, et al. Bacterial keratitis: predisposing factors, clinical and microbiological review of 300 cases. Br J Ophthalmol 2003, 87(7):834-838.
    • (2003) Br J Ophthalmol , vol.87 , Issue.7 , pp. 834-838
    • Bourcier, T.1    Thomas, F.2
  • 175
    • 0036189164 scopus 로고    scopus 로고
    • Microbial keratitis associated with extended wear of silicone hydrogel contact lenses
    • Lim L, Loughnan MS, et al. Microbial keratitis associated with extended wear of silicone hydrogel contact lenses. Br J Ophthalmol 2002, 86(3):355-357.
    • (2002) Br J Ophthalmol , vol.86 , Issue.3 , pp. 355-357
    • Lim, L.1    Loughnan, M.S.2
  • 176
    • 0642273807 scopus 로고    scopus 로고
    • Pseudomonas keratitis associated with continuous wear silicone-hydrogel soft contact lens: a case report
    • Lee KY, Lim L Pseudomonas keratitis associated with continuous wear silicone-hydrogel soft contact lens: a case report. Eye Cont Lens 2003, 29(4):255-257.
    • (2003) Eye Cont Lens , vol.29 , Issue.4 , pp. 255-257
    • Lee, K.Y.1    Lim, L.2
  • 177
    • 1842557319 scopus 로고    scopus 로고
    • Mixed infection ( Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens
    • Syam P, Hussain B, et al. Mixed infection ( Pseudomonas and coagulase negative staphylococci) microbial keratitis associated with extended wear silicone hydrogel contact lens. Br J Ophthalmol 2004, 88(4):579.
    • (2004) Br J Ophthalmol , vol.88 , Issue.4 , pp. 579
    • Syam, P.1    Hussain, B.2
  • 178
    • 4444269053 scopus 로고    scopus 로고
    • Continuous wear silicone hydrogel contact lenses and microbial keratitis
    • Whiting MA, Raynor MK, et al. Continuous wear silicone hydrogel contact lenses and microbial keratitis. Eye 2004.
    • (2004) Eye
    • Whiting, M.A.1    Raynor, M.K.2
  • 179
    • 0035726558 scopus 로고    scopus 로고
    • Contact lens related corneal infections
    • Willcox MD, Holden BA Contact lens related corneal infections. Biosci Rep 2001, 21(4):445-461.
    • (2001) Biosci Rep , vol.21 , Issue.4 , pp. 445-461
    • Willcox, M.D.1    Holden, B.A.2
  • 180
    • 33750337123 scopus 로고    scopus 로고
    • Microbial keratitis
    • Butterworth-Heinemann, London, N. Efron (Ed.)
    • Efron N Microbial keratitis. Contact Lens Complications 2004, 175-186. Butterworth-Heinemann, London. ed 2. N. Efron (Ed.).
    • (2004) Contact Lens Complications , pp. 175-186
    • Efron, N.1
  • 181
    • 0024235389 scopus 로고
    • Predisposing factors in microbial keratitis: the significance of contact lens wear
    • Dart J Predisposing factors in microbial keratitis: the significance of contact lens wear. Br J Ophthalmol 1988, 72:926-930.
    • (1988) Br J Ophthalmol , vol.72 , pp. 926-930
    • Dart, J.1
  • 182
    • 0029160419 scopus 로고
    • Microbial etiology and predisposing factors among patients hospitalized for corneal ulceration
    • Cheung J, Slomovic AR Microbial etiology and predisposing factors among patients hospitalized for corneal ulceration. Can J Ophthalmol 1995, 30(5):251-255.
    • (1995) Can J Ophthalmol , vol.30 , Issue.5 , pp. 251-255
    • Cheung, J.1    Slomovic, A.R.2
  • 183
    • 0023895494 scopus 로고
    • Infected vs sterile corneal infiltrates in contact lens wearers
    • Stein RM, Clinch TE, et al. Infected vs sterile corneal infiltrates in contact lens wearers. Am J Ophthalmol 1988, 105(6):632-636.
    • (1988) Am J Ophthalmol , vol.105 , Issue.6 , pp. 632-636
    • Stein, R.M.1    Clinch, T.E.2
  • 184
    • 0037523497 scopus 로고    scopus 로고
    • Clinical characterization of corneal infiltrative events observed with soft contact lens wear
    • Sweeney DF, Jalbert I, et al. Clinical characterization of corneal infiltrative events observed with soft contact lens wear. Cornea 2003, 22(5):435-442.
    • (2003) Cornea , vol.22 , Issue.5 , pp. 435-442
    • Sweeney, D.F.1    Jalbert, I.2
  • 185
    • 0024442901 scopus 로고
    • Microbiology of contact lens-related keratitis
    • Schein OD, Ormerod LD, et al. Microbiology of contact lens-related keratitis. Cornea 1989, 8(4):281-285.
    • (1989) Cornea , vol.8 , Issue.4 , pp. 281-285
    • Schein, O.D.1    Ormerod, L.D.2
  • 187
    • 0029085816 scopus 로고
    • Strategies for the management of microbial keratitis
    • Allan B, Dart J Strategies for the management of microbial keratitis. Br J Ophthalmol 1995, 79:777-786.
    • (1995) Br J Ophthalmol , vol.79 , pp. 777-786
    • Allan, B.1    Dart, J.2
  • 188
    • 0031966695 scopus 로고    scopus 로고
    • Antimicrobial management of presumed microbial keratitis: guidelines for treatment of central and peripheral ulcers
    • Bennett H, Hay J, et al. Antimicrobial management of presumed microbial keratitis: guidelines for treatment of central and peripheral ulcers. Br J Ophthalmol 1998, 82:137-145.
    • (1998) Br J Ophthalmol , vol.82 , pp. 137-145
    • Bennett, H.1    Hay, J.2
  • 189
    • 0002090669 scopus 로고
    • Pseudomonas corneal ulcers associated with daily wear of disposable hydrogel contact lenses
    • Efron N, Wohl A, et al. Pseudomonas corneal ulcers associated with daily wear of disposable hydrogel contact lenses. ICLC 1991, 18(3/4):46-52.
    • (1991) ICLC , vol.18 , Issue.3-4 , pp. 46-52
    • Efron, N.1    Wohl, A.2
  • 190
    • 0005262060 scopus 로고    scopus 로고
    • A prospective study of non-compliance in contact lens wear
    • Claydon B, Efron N, et al. A prospective study of non-compliance in contact lens wear. J BCLA 1996, 19(4):133-140.
    • (1996) J BCLA , vol.19 , Issue.4 , pp. 133-140
    • Claydon, B.1    Efron, N.2
  • 191
    • 0028033039 scopus 로고
    • Non compliance in contact lens wear
    • Claydon B, Efron N Non compliance in contact lens wear. Ophthalmol Physiol Opt 1994, 14:356-364.
    • (1994) Ophthalmol Physiol Opt , vol.14 , pp. 356-364
    • Claydon, B.1    Efron, N.2
  • 192
    • 0035084595 scopus 로고    scopus 로고
    • Trends in contact lens-related corneal ulcers
    • Rattanatam T, Heng WJ, et al. Trends in contact lens-related corneal ulcers. Cornea 2001, 20(3):290-294.
    • (2001) Cornea , vol.20 , Issue.3 , pp. 290-294
    • Rattanatam, T.1    Heng, W.J.2
  • 193
    • 0031750255 scopus 로고    scopus 로고
    • Bacterial biofilm on contact lenses and lens storage cases in wearers with microbial keratitis
    • McLaughlin-Borlace L, Stapleton F, et al. Bacterial biofilm on contact lenses and lens storage cases in wearers with microbial keratitis. J Appl Microbiol 1998, 84(5):827-838.
    • (1998) J Appl Microbiol , vol.84 , Issue.5 , pp. 827-838
    • McLaughlin-Borlace, L.1    Stapleton, F.2
  • 194
    • 0038002392 scopus 로고    scopus 로고
    • Contact lens-related microbial keratitis: what can epidemiologic studies tell us?
    • discussion S115-118, S192-114.
    • Stapleton F Contact lens-related microbial keratitis: what can epidemiologic studies tell us?. Eye Cont Lens 2003, 29(1 Suppl):S85-S89. discussion S115-118, S192-114.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 SUPPL
    • Stapleton, F.1
  • 195
    • 0036527055 scopus 로고    scopus 로고
    • Bacterial keratitis and inflammatory corneal reactions: possible relations to contact lens oxygen transmissibility: the Harold A. Stein Lectureship 2001
    • Nilsson SE Bacterial keratitis and inflammatory corneal reactions: possible relations to contact lens oxygen transmissibility: the Harold A. Stein Lectureship 2001. CLAO J 2002, 28(2):62-65.
    • (2002) CLAO J , vol.28 , Issue.2 , pp. 62-65
    • Nilsson, S.E.1
  • 196
    • 0032900683 scopus 로고    scopus 로고
    • The relationship between contact lens oxygen permeability and binding of Pseudomonas aeruginosa to human corneal epithelial cells after overnight and extended wear
    • Ren DH, Petroll WM, et al. The relationship between contact lens oxygen permeability and binding of Pseudomonas aeruginosa to human corneal epithelial cells after overnight and extended wear. CLAO J 1999, 25(2):80-100.
    • (1999) CLAO J , vol.25 , Issue.2 , pp. 80-100
    • Ren, D.H.1    Petroll, W.M.2
  • 197
    • 0034972703 scopus 로고    scopus 로고
    • Effects of rigid and soft contact lens daily wear on corneal epithelium, tear lactate dehydrogenase, and bacterial binding to exfoliated epithelial cells
    • Ladage PM, Yamamoto K, et al. Effects of rigid and soft contact lens daily wear on corneal epithelium, tear lactate dehydrogenase, and bacterial binding to exfoliated epithelial cells. Ophthalmology 2001, 108(7):1279-1288.
    • (2001) Ophthalmology , vol.108 , Issue.7 , pp. 1279-1288
    • Ladage, P.M.1    Yamamoto, K.2
  • 198
    • 0038148468 scopus 로고    scopus 로고
    • A 1-year prospective clinical trial of menicon Z (tisil-focon A) rigid gas-permeable contact lenses worn on a 30-day continuous wear schedule
    • Gleason W, Tanaka H, et al. A 1-year prospective clinical trial of menicon Z (tisil-focon A) rigid gas-permeable contact lenses worn on a 30-day continuous wear schedule. Eye Cont Lens 2003, 29(1):2-9.
    • (2003) Eye Cont Lens , vol.29 , Issue.1 , pp. 2-9
    • Gleason, W.1    Tanaka, H.2
  • 199
    • 1942468628 scopus 로고    scopus 로고
    • Biological performance of a novel synthetic furanone-based antimicrobial
    • Baveja JK, Li G, et al. Biological performance of a novel synthetic furanone-based antimicrobial. Biomaterials 2004, 25(20):5013-5021.
    • (2004) Biomaterials , vol.25 , Issue.20 , pp. 5013-5021
    • Baveja, J.K.1    Li, G.2
  • 200
    • 1942470982 scopus 로고    scopus 로고
    • Furanones as potential anti-bacterial coatings on biomaterials
    • Baveja JK, Willcox MD, et al. Furanones as potential anti-bacterial coatings on biomaterials. Biomaterials 2004, 25(20):5003-5012.
    • (2004) Biomaterials , vol.25 , Issue.20 , pp. 5003-5012
    • Baveja, J.K.1    Willcox, M.D.2
  • 201
    • 11144355417 scopus 로고    scopus 로고
    • The control of Staphylococcus epidermidis biofilm formation and in vivo infection rates by covalently bound furanones
    • Hume EB, Baveja J, Muir B, et al. The control of Staphylococcus epidermidis biofilm formation and in vivo infection rates by covalently bound furanones. Biomaterials 2004, 25(20):5023-5030.
    • (2004) Biomaterials , vol.25 , Issue.20 , pp. 5023-5030
    • Hume, E.B.1    Baveja, J.2    Muir, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.