메뉴 건너뛰기




Volumn 26, Issue 4, 2003, Pages 189-196

Local oxygen transmissibility of disposable contact lenses

Author keywords

Disposable contact lenses; Oxygen permeability; Oxygen transmissibility

Indexed keywords

OXYGEN; SILICON;

EID: 0348219111     PISSN: 13670484     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clae.2003.09.001     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 0031030277 scopus 로고    scopus 로고
    • Comparative study of some physiologically important properties of six brands of disposable hydrogel contact lenses
    • Fatt I. Comparative study of some physiologically important properties of six brands of disposable hydrogel contact lenses. Contact Lens Assoc Ophthalmol J 1997;23:49-54.
    • (1997) Contact Lens Assoc. Ophthalmol. J. , vol.23 , pp. 49-54
    • Fatt, I.1
  • 2
    • 0030111172 scopus 로고    scopus 로고
    • Oxygen transmissibility at various locations in hydrogel toric prism-ballasted contact lenses
    • Eghbali F, Hsui EH, Eghbali K, Weissman BA. Oxygen transmissibility at various locations in hydrogel toric prism-ballasted contact lenses. Optom Vis Sci 1996;73(3):164-8.
    • (1996) Optom. Vis. Sci. , vol.73 , Issue.3 , pp. 164-168
    • Eghbali, F.1    Hsui, E.H.2    Eghbali, K.3    Weissman, B.A.4
  • 3
    • 0027570611 scopus 로고
    • EOP and Dk/L: The quest for hyper transmissibility
    • Benjamin WJ. EOP and Dk/L: the quest for hyper transmissibility. J Am Optom Assoc 1993;64:196-200.
    • (1993) J. Am. Optom. Assoc. , vol.64 , pp. 196-200
    • Benjamin, W.J.1
  • 4
    • 0025039785 scopus 로고
    • Corneal pathophysiology with contact lenses
    • Bruce AS, Brennan NA. Corneal pathophysiology with contact lenses. Surv Ophthalmol 1990;35(1):25-58.
    • (1990) Surv. Ophthalmol. , vol.35 , Issue.1 , pp. 25-58
    • Bruce, A.S.1    Brennan, N.A.2
  • 5
    • 0021123317 scopus 로고
    • Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
    • Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984;25:1161-7.
    • (1984) Invest. Ophthalmol. Vis. Sci. , vol.25 , pp. 1161-1167
    • Holden, B.A.1    Mertz, G.W.2
  • 6
    • 0032144577 scopus 로고    scopus 로고
    • On the relationship between soft contact lens oxygen transmissibility and induced limbal hyperaemia
    • Papas E. On the relationship between soft contact lens oxygen transmissibility and induced limbal hyperaemia. Exp Eye Res 1998;67:125-31.
    • (1998) Exp. Eye Res. , vol.67 , pp. 125-131
    • Papas, E.1
  • 7
    • 0346470455 scopus 로고    scopus 로고
    • Downsizing of Dk and Dk/L: The difficulty in using hPa instead of mmHg
    • Benjamin WJ. Downsizing of Dk and Dk/L: the difficulty in using hPa instead of mmHg. Int Contact Lens Clin 1996;23:188-9.
    • (1996) Int. Contact Lens Clin. , vol.23 , pp. 188-189
    • Benjamin, W.J.1
  • 8
    • 0030067863 scopus 로고    scopus 로고
    • New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health
    • Fatt I. New physiological paradigms to assess the effect of lens oxygen transmissibility on corneal health. Contact Lens Assoc Ophthalmol J 1996;22(1):25-9.
    • (1996) Contact Lens Assoc. Ophthalmol. J. , vol.22 , Issue.1 , pp. 25-29
    • Fatt, I.1
  • 9
    • 0023877141 scopus 로고
    • Limited lateral spread of stromal edema in the human cornea fitted with a ('donut') contact lens with a large central aperture
    • Holden BA, McNally JJ, Egan P. Limited lateral spread of stromal edema in the human cornea fitted with a ('donut') contact lens with a large central aperture. Curr Eye Res 1988;7(6):601-5.
    • (1988) Curr. Eye Res. , vol.7 , Issue.6 , pp. 601-605
    • Holden, B.A.1    McNally, J.J.2    Egan, P.3
  • 10
    • 0030273109 scopus 로고    scopus 로고
    • Distribution of oxygen across the surface of the human cornea during soft contact lens wear
    • Efron N, Fitzgerald JP. Distribution of oxygen across the surface of the human cornea during soft contact lens wear. Optom Vis Sci 1996;73:659-65.
    • (1996) Optom. Vis. Sci. , vol.73 , pp. 659-665
    • Efron, N.1    Fitzgerald, J.P.2
  • 11
    • 0001555653 scopus 로고
    • Measuring oxygen permeability of gas permeable hard and hydrogel lenses and flat samples in air
    • Fatt I, Rasson JE, Melpolder JB. Measuring oxygen permeability of gas permeable hard and hydrogel lenses and flat samples in air. Int Contact Lens Clin 1987;14:389-402.
    • (1987) Int. Contact Lens Clin. , vol.14 , pp. 389-402
    • Fatt, I.1    Rasson, J.E.2    Melpolder, J.B.3
  • 12
    • 0001871901 scopus 로고    scopus 로고
    • The oxygen performance of contemporary hydrogel contact lenses
    • Morgan PB, Efron N. The oxygen performance of contemporary hydrogel contact lenses. Contact Lens Anterior Eye 1998;21:3-6.
    • (1998) Contact Lens Anterior Eye , vol.21 , pp. 3-6
    • Morgan, P.B.1    Efron, N.2
  • 13
    • 0008489232 scopus 로고    scopus 로고
    • "Wiggle Room" and the transitional Dk statistic
    • Benjamin WJ. "Wiggle Room" and the transitional Dk statistic. Int Contact Lens Clin 1998;25:118-20.
    • (1998) Int. Contact Lens Clin. , vol.25 , pp. 118-120
    • Benjamin, W.J.1
  • 14
    • 84990602621 scopus 로고
    • Simple measurement of oxygen transmissibility
    • Efron N, Brennan NA. Simple measurement of oxygen transmissibility. Aust J Optom 1985;68:27-35.
    • (1985) Aust. J. Optom. , vol.68 , pp. 27-35
    • Efron, N.1    Brennan, N.A.2
  • 15
    • 0347731243 scopus 로고
    • Optimizing the thickness-water content relationship for hydrogel lenses
    • Brennan NA, Carney LG. Optimizing the thickness-water content relationship for hydrogel lenses. Contact Lens Assoc Ophthalmol J 1987;13:264-7.
    • (1987) Contact Lens Assoc. Ophthalmol. J. , vol.13 , pp. 264-267
    • Brennan, N.A.1    Carney, L.G.2
  • 17
    • 0001786961 scopus 로고
    • Measurement of oxygen transmissibility and permeability of hydrogel lenses and materials
    • Fatt I, Chaston J. Measurement of oxygen transmissibility and permeability of hydrogel lenses and materials. Int Contact Lens Clin 1982;9:76-88.
    • (1982) Int. Contact Lens Clin. , vol.9 , pp. 76-88
    • Fatt, I.1    Chaston, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.