메뉴 건너뛰기




Volumn 42, Issue 5, 1999, Pages 813-828

Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI

Author keywords

Cardiac imaging; Dynamic imaging; fMRI; Rapid imaging; Reduced FOV

Indexed keywords

CHEMICAL ACTIVATION; HEART; SIGNAL ENCODING;

EID: 0032751897     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO;2-S     Document Type: Article
Times cited : (378)

References (52)
  • 2
    • 0029029302 scopus 로고
    • Three-dimensional myocardial deformations: Calculation with displacement field fitting to tagged MR images
    • O'Dell WG, Moore CC, Hunter WC, Zerhouni EA, McVeigh ER. Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. Radiology 1995;195:829-835.
    • (1995) Radiology , vol.195 , pp. 829-835
    • O'Dell, W.G.1    Moore, C.C.2    Hunter, W.C.3    Zerhouni, E.A.4    McVeigh, E.R.5
  • 3
    • 0024469533 scopus 로고
    • Retrospective cardiac gating: A review of technical aspects and future directions
    • Lenz GW, Haacke EM, White RD. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Imaging 1989;7: 445-455.
    • (1989) Magn Reson Imaging , vol.7 , pp. 445-455
    • Lenz, G.W.1    Haacke, E.M.2    White, R.D.3
  • 6
    • 0026478873 scopus 로고
    • Real-time dynamics of an extravascular magnetic resonance contrast medium in acutely infarcted myocardium using inversion recovery and gradient-recalled echo-planar imaging
    • Yu KK, Saeed M, Wendland MF, Derugin N, Cavagna FM, Higgins CB. Real-time dynamics of an extravascular magnetic resonance contrast medium in acutely infarcted myocardium using inversion recovery and gradient-recalled echo-planar imaging. Invest Radiol 1992;27:927-934.
    • (1992) Invest Radiol , vol.27 , pp. 927-934
    • Yu, K.K.1    Saeed, M.2    Wendland, M.F.3    Derugin, N.4    Cavagna, F.M.5    Higgins, C.B.6
  • 7
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990;87:9868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 8
    • 0027403503 scopus 로고
    • The sensitivity of magnetic resonance image signals of a rat brain to changes in the cerebral venous blood oxygenation
    • Ogawa S, Lee TM, Barrere B. The sensitivity of magnetic resonance image signals of a rat brain to changes in the cerebral venous blood oxygenation. Magn Reson Med 1993;29:205-210.
    • (1993) Magn Reson Med , vol.29 , pp. 205-210
    • Ogawa, S.1    Lee, T.M.2    Barrere, B.3
  • 11
    • 0024580929 scopus 로고
    • MR imaging of the breast: Fast imaging sequences with and without Gd-DTPA. Preliminary observations
    • Kaiser WA, Zeitler E. MR imaging of the breast: fast imaging sequences with and without Gd-DTPA. preliminary observations. Radiology 1989; 170:681-686.
    • (1989) Radiology , vol.170 , pp. 681-686
    • Kaiser, W.A.1    Zeitler, E.2
  • 12
    • 23744477998 scopus 로고    scopus 로고
    • Dynamic MR imaging of the breast combined with analysis of contrast agent kinetics in the differentiation of primary breast tumours
    • Mussurakis S, Buckley DL, Drew PJ, Fox JN, Carleton PJ, Turnbull LW, Horsman A. Dynamic MR imaging of the breast combined with analysis of contrast agent kinetics in the differentiation of primary breast tumours. Clin Radiol 1997;52:516-526.
    • (1997) Clin Radiol , vol.52 , pp. 516-526
    • Mussurakis, S.1    Buckley, D.L.2    Drew, P.J.3    Fox, J.N.4    Carleton, P.J.5    Turnbull, L.W.6    Horsman, A.7
  • 16
    • 0027468047 scopus 로고
    • K-space description for MR imaging of dynamic objects
    • Xiang QS, Henkelman RM. K-space description for MR imaging of dynamic objects. Magn Reson Med 1993;29:422-428.
    • (1993) Magn Reson Med , vol.29 , pp. 422-428
    • Xiang, Q.S.1    Henkelman, R.M.2
  • 19
    • 0031421868 scopus 로고    scopus 로고
    • Limitations of the keyhole technique for quantitative dynamic contrast-enhanced breast MRI
    • Bishop JE, Santyr GE, Kelcz F, Plewes DB. Limitations of the keyhole technique for quantitative dynamic contrast-enhanced breast MRI. J Magn Reson Imaging 1997;7:716-723.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 716-723
    • Bishop, J.E.1    Santyr, G.E.2    Kelcz, F.3    Plewes, D.B.4
  • 20
    • 0029035832 scopus 로고
    • Dynamic three-dimensional imaging with partial k-space sampling: Initial application for gadolinium-enhanced rate characterization of breast lesions
    • Chenevert TL, Helvie MA, Aisen AM, Francis IR, Adler DD, Roubidoux MA, Londy FJ. Dynamic three-dimensional imaging with partial k-space sampling: initial application for gadolinium-enhanced rate characterization of breast lesions. Radiology 1995;196:135-142.
    • (1995) Radiology , vol.196 , pp. 135-142
    • Chenevert, T.L.1    Helvie, M.A.2    Aisen, A.M.3    Francis, I.R.4    Adler, D.D.5    Roubidoux, M.A.6    Londy, F.J.7
  • 21
    • 0027690283 scopus 로고
    • Application of reduced-encoding MR imaging with generalized-series reconstruction (RIGR)
    • Webb AG, Liang Z-P, Magin RL, Lauterbur PC. Application of reduced-encoding MR imaging with generalized-series reconstruction (RIGR). J Magn Reson Imaging 1993;3:925-928.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 925-928
    • Webb, A.G.1    Liang, Z.-P.2    Magin, R.L.3    Lauterbur, P.C.4
  • 22
    • 0030227654 scopus 로고    scopus 로고
    • Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging
    • Chandra S, Liang Z-P, Webb A, Lee H, Morris D, Lauterbur PC. Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging. J Magn Reson Imaging 1996;6:783-797.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 783-797
    • Chandra, S.1    Liang, Z.-P.2    Webb, A.3    Lee, H.4    Morris, D.5    Lauterbur, P.C.6
  • 25
    • 0028936695 scopus 로고
    • Continuous update with random encoding (CURE): A new strategy for dynamic imaging
    • Parrish T, Hu X. Continuous update with random encoding (CURE): a new strategy for dynamic imaging. Magn Reson Med 1995;33:326-336.
    • (1995) Magn Reson Med , vol.33 , pp. 326-336
    • Parrish, T.1    Hu, X.2
  • 27
    • 0029088782 scopus 로고
    • Magnetic resonance fluoroscopy using spirals with variable sampling densities
    • Spielman DM, Pauly JM, Meyer CH. Magnetic resonance fluoroscopy using spirals with variable sampling densities. Magn Reson Med 1995;34:388-394.
    • (1995) Magn Reson Med , vol.34 , pp. 388-394
    • Spielman, D.M.1    Pauly, J.M.2    Meyer, C.H.3
  • 29
    • 0028509723 scopus 로고
    • Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography
    • Du YP, Parker DL, Davis WL, Cao G. Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging 1994;4:733-741.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 733-741
    • Du, Y.P.1    Parker, D.L.2    Davis, W.L.3    Cao, G.4
  • 30
    • 0030012103 scopus 로고    scopus 로고
    • Temporal resolution improvement in dynamic imaging
    • Fredrickson JO, Pelc NJ. Temporal resolution improvement in dynamic imaging. Magn Reson Med 1996;35:621-625.
    • (1996) Magn Reson Med , vol.35 , pp. 621-625
    • Fredrickson, J.O.1    Pelc, N.J.2
  • 31
    • 0028364190 scopus 로고
    • Reduction of field of view for dynamic imaging
    • Hu X, Parrish T. Reduction of field of view for dynamic imaging. Magn Reson Med 1994;31:691-694.
    • (1994) Magn Reson Med , vol.31 , pp. 691-694
    • Hu, X.1    Parrish, T.2
  • 32
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • Scheffler K, Hennig J. Reduced circular field-of-view imaging. Magn Reson Med 1998;40:474-480.
    • (1998) Magn Reson Med , vol.40 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 33
    • 0031400791 scopus 로고    scopus 로고
    • Implementation of a reduced field-of-view method for dynamic MR imaging using navigator echoes
    • Kyriakos WE, Panych LP, Zientara GP, Jolesz FA. Implementation of a reduced field-of-view method for dynamic MR imaging using navigator echoes. J Magn Reson Imaging 1997;7:376-381.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 376-381
    • Kyriakos, W.E.1    Panych, L.P.2    Zientara, G.P.3    Jolesz, F.A.4
  • 34
    • 0027992115 scopus 로고
    • Dynamically adaptive MRI with encoding by singular value decomposition
    • Zientara GP, Panych LP, Jolesz FA. Dynamically adaptive MRI with encoding by singular value decomposition. Magn Reson Med 1994;32: 268-274.
    • (1994) Magn Reson Med , vol.32 , pp. 268-274
    • Zientara, G.P.1    Panych, L.P.2    Jolesz, F.A.3
  • 35
    • 0029923709 scopus 로고    scopus 로고
    • Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging
    • Panych LP, Oesterle C, Zientara GP, Hennig J. Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging. Magn Reson Med 1996;35:554-562.
    • (1996) Magn Reson Med , vol.35 , pp. 554-562
    • Panych, L.P.1    Oesterle, C.2    Zientara, G.P.3    Hennig, J.4
  • 36
    • 0028021032 scopus 로고
    • Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging
    • Panych LP, Jolesz FA. Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging. Magn Reson Med 1994;32: 738-748.
    • (1994) Magn Reson Med , vol.32 , pp. 738-748
    • Panych, L.P.1    Jolesz, F.A.2
  • 37
    • 0030138361 scopus 로고    scopus 로고
    • Multilevel wavelet-transform encoding in MRI
    • Peters RD, Wood ML. Multilevel wavelet-transform encoding in MRI. J Magn Reson Imaging 1996;6:529-540.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 529-540
    • Peters, R.D.1    Wood, M.L.2
  • 42
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo planar imaging using image phase correction
    • Buonocore MH, Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 1997;38:89-100.
    • (1997) Magn Reson Med , vol.38 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 44
    • 0030229278 scopus 로고    scopus 로고
    • Noise in MRI
    • Macovski A. Noise in MRI. Magn Reson Med 1996;36:494-497.
    • (1996) Magn Reson Med , vol.36 , pp. 494-497
    • Macovski, A.1
  • 45
    • 0030885132 scopus 로고    scopus 로고
    • Noise suppression digital filter for functional magnetic resonance imaging based on image reference data
    • Buonocore MH, Maddock RJ. Noise suppression digital filter for functional magnetic resonance imaging based on image reference data. Magn Reson Med 1997;38:456-469.
    • (1997) Magn Reson Med , vol.38 , pp. 456-469
    • Buonocore, M.H.1    Maddock, R.J.2
  • 46
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence
    • Atkinson DJ, Edelman RR. Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. Radiology 1991; 178:357-360.
    • (1991) Radiology , vol.178 , pp. 357-360
    • Atkinson, D.J.1    Edelman, R.R.2
  • 47
    • 0028953895 scopus 로고
    • Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques
    • Foo TKF, Bernstein MA, Aisen AM, Hernandez RJ, Collick BD, Bernstein T. Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques. Radiology 1995;195:471-478.
    • (1995) Radiology , vol.195 , pp. 471-478
    • Foo, T.K.F.1    Bernstein, M.A.2    Aisen, A.M.3    Hernandez, R.J.4    Collick, B.D.5    Bernstein, T.6
  • 48
    • 0028957906 scopus 로고
    • Fast three dimensional magnetic resonance imaging
    • Irrazabal P, Nishimura DG. Fast three dimensional magnetic resonance imaging. Magn Reson Med 1995;33:656-662.
    • (1995) Magn Reson Med , vol.33 , pp. 656-662
    • Irrazabal, P.1    Nishimura, D.G.2
  • 49
    • 0031975491 scopus 로고    scopus 로고
    • Three-dimensional spiral fMRI technique: A comparison with 2D spiral acquisition
    • Lai S, Glover GH. Three-dimensional spiral fMRI technique: a comparison with 2D spiral acquisition. Magn Reson Med 1998;39:68-78.
    • (1998) Magn Reson Med , vol.39 , pp. 68-78
    • Lai, S.1    Glover, G.H.2
  • 52
    • 0342742976 scopus 로고    scopus 로고
    • Contrast in single trial fMRI: Interstimulus interval dependency and comparison with blocked strategies
    • Sydney
    • Bandettini PA, Cox RW. Contrast in single trial fMRI: interstimulus interval dependency and comparison with blocked strategies. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, 1998, p 161.
    • (1998) Proceedings of the 6th Annual Meeting of ISMRM , pp. 161
    • Bandettini, P.A.1    Cox, R.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.