메뉴 건너뛰기




Volumn 2006, Issue , 2006, Pages 45-48

Optimal multi-channel time-sequential acquisition in dynamic MRI with parallel coils

Author keywords

[No Author keywords available]

Indexed keywords

ACCELERATION; ADAPTIVE SYSTEMS; COMPUTER SIMULATION; IMAGE CODING; MEDICAL IMAGING;

EID: 33750934590     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (12)

References (7)
  • 1
    • 17144369420 scopus 로고    scopus 로고
    • Dynamic imaging of time-varying objects
    • Qi Zhao, Nitin Aggarwal, and Yoram Bresler, "Dynamic imaging of time-varying objects," in Proc. of ISMRM, 2001, p. 1776.
    • (2001) Proc. of ISMRM , pp. 1776
    • Zhao, Q.1    Aggarwal, N.2    Bresler, Y.3
  • 2
    • 84948653511 scopus 로고    scopus 로고
    • Fast acquisition and sampling in MRI: Introduction to time-sequential sampling of spatio-temporal signals
    • July
    • Yoram Bresler, "Fast acquisition and sampling in MRI: Introduction to time-sequential sampling of spatio-temporal signals," in Proc. ISBI, July 2002, pp. 713-716.
    • (2002) Proc. ISBI , pp. 713-716
    • Bresler, Y.1
  • 3
    • 84948655755 scopus 로고    scopus 로고
    • Spatio-temporal modeling and minimum redundancy adaptive acquisition in dynamic MRI
    • July
    • Nitin Aggarwal, Qi Zhao, and Yoram Bresler, "Spatio-temporal modeling and minimum redundancy adaptive acquisition in dynamic MRI," in Proc. ISBI, July 2002, pp. 737-740.
    • (2002) Proc. ISBI , pp. 737-740
    • Aggarwal, N.1    Zhao, Q.2    Bresler, Y.3
  • 4
    • 0030826830 scopus 로고    scopus 로고
    • Lattice-theoretic analysis of time-sequential sampling of spatio-temporal signals part i
    • January
    • N. P. Willis and Y. Bresler, "Lattice-theoretic analysis of time-sequential sampling of spatio-temporal signals part i," IEEE Trans. Information Theory, pp. 190-207, January 1997.
    • (1997) IEEE Trans. Information Theory , pp. 190-207
    • Willis, N.P.1    Bresler, Y.2
  • 5
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • K. P. Pruessmann et al., "SENSE: Sensitivity encoding for fast MRI," Mag. Res. in Medicine, vol. 42, pp. 952-962, 1999.
    • (1999) Mag. Res. in Medicine , vol.42 , pp. 952-962
    • Pruessmann, K.P.1
  • 6
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • M. A. Griswold et al., "Generalized autocalibrating partially parallel acquisitions (GRAPPA)," Magnetic Resonance in Medicine, vol. 6, pp. 1202-1210, 2002.
    • (2002) Magnetic Resonance in Medicine , vol.6 , pp. 1202-1210
    • Griswold, M.A.1
  • 7
    • 12144280400 scopus 로고    scopus 로고
    • Sensitivity enconding as a means of enhancing the SNR efficiency in steady-state MRI
    • M. Weiger et al., "Sensitivity enconding as a means of enhancing the SNR efficiency in steady-state MRI," Mag. Res. in Medicine, vol. 53, pp. 177-185, 2005.
    • (2005) Mag. Res. in Medicine , vol.53 , pp. 177-185
    • Weiger, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.