-
1
-
-
0028641172
-
Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) Registry
-
Emond M., Mock M.B., Davis K.B., Fisher L.D., Holmes Jr. D.R., Chaitman B.R., Kaiser G.C., Alderman E., and Killip III T. Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) Registry. Circulation 90 6 (1994) 2645-2657
-
(1994)
Circulation
, vol.90
, Issue.6
, pp. 2645-2657
-
-
Emond, M.1
Mock, M.B.2
Davis, K.B.3
Fisher, L.D.4
Holmes Jr., D.R.5
Chaitman, B.R.6
Kaiser, G.C.7
Alderman, E.8
Killip III, T.9
-
2
-
-
0018375301
-
Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations
-
Hammermeister K.E., DeRouen T.A., and Dodge H.T. Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations. Circulation 59 3 (1979) 421-430
-
(1979)
Circulation
, vol.59
, Issue.3
, pp. 421-430
-
-
Hammermeister, K.E.1
DeRouen, T.A.2
Dodge, H.T.3
-
3
-
-
0023219810
-
Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction
-
White H.D., Norris R.M., Brown M.A., Brandt P.W., Whitlock R.M., and Wild C.J. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 76 1 (1987) 44-51
-
(1987)
Circulation
, vol.76
, Issue.1
, pp. 44-51
-
-
White, H.D.1
Norris, R.M.2
Brown, M.A.3
Brandt, P.W.4
Whitlock, R.M.5
Wild, C.J.6
-
4
-
-
0033956375
-
Long term prognosis after CABG in relation to preoperative left ventricular ejection fraction
-
discussion 73-4
-
Herlitz J., Karlson B.W., Sjoland H., Brandrup-Wognsen G., Haglid M., Karlsson T., and Caidahl K. Long term prognosis after CABG in relation to preoperative left ventricular ejection fraction. Int J Cardiol 72 2 (2000) 163-171 discussion 73-4
-
(2000)
Int J Cardiol
, vol.72
, Issue.2
, pp. 163-171
-
-
Herlitz, J.1
Karlson, B.W.2
Sjoland, H.3
Brandrup-Wognsen, G.4
Haglid, M.5
Karlsson, T.6
Caidahl, K.7
-
5
-
-
0028800394
-
Left ventricular end-systolic volume index in patients with ischemic cardiomyopathy predicts postoperative ventricular function
-
Yamaguchi A., Ino T., Adachi H., Mizuhara A., Murata S., and Kamio H. Left ventricular end-systolic volume index in patients with ischemic cardiomyopathy predicts postoperative ventricular function. Ann Thorac Surg 60 4 (1995) 1059-1062
-
(1995)
Ann Thorac Surg
, vol.60
, Issue.4
, pp. 1059-1062
-
-
Yamaguchi, A.1
Ino, T.2
Adachi, H.3
Mizuhara, A.4
Murata, S.5
Kamio, H.6
-
6
-
-
0015620724
-
Left ventricular function and hypertrophy in cardiomyopathy with depressed ejection fraction
-
Feild B.J., Baxley W.A., Russell Jr. R.O., Hood Jr. W.P., Holt J.H., Dowling J.T., and Rackley C.E. Left ventricular function and hypertrophy in cardiomyopathy with depressed ejection fraction. Circulation 47 5 (1973) 1022-1031
-
(1973)
Circulation
, vol.47
, Issue.5
, pp. 1022-1031
-
-
Feild, B.J.1
Baxley, W.A.2
Russell Jr., R.O.3
Hood Jr., W.P.4
Holt, J.H.5
Dowling, J.T.6
Rackley, C.E.7
-
7
-
-
0021319917
-
The relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality in the 2 years after myocardial infarction
-
Bigger Jr. J.T., Fleiss J.L., Kleiger R., Miller J.P., and Rolnitzky L.M. The relationships among ventricular arrhythmias, left ventricular dysfunction, and mortality in the 2 years after myocardial infarction. Circulation 69 2 (1984) 250-258
-
(1984)
Circulation
, vol.69
, Issue.2
, pp. 250-258
-
-
Bigger Jr., J.T.1
Fleiss, J.L.2
Kleiger, R.3
Miller, J.P.4
Rolnitzky, L.M.5
-
8
-
-
0006918490
-
Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators
-
Moss A.J., Hall W.J., Cannom D.S., Daubert J.P., Higgins S.L., Klein H., Levine J.H., Saksena S., Waldo A.L., Wilber D., Brown M.W., and Heo M. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med 335 26 (1996) 1933-1940
-
(1996)
N Engl J Med
, vol.335
, Issue.26
, pp. 1933-1940
-
-
Moss, A.J.1
Hall, W.J.2
Cannom, D.S.3
Daubert, J.P.4
Higgins, S.L.5
Klein, H.6
Levine, J.H.7
Saksena, S.8
Waldo, A.L.9
Wilber, D.10
Brown, M.W.11
Heo, M.12
-
9
-
-
0037149716
-
Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
-
Moss A.J., Zareba W., Hall W.J., Klein H., Wilber D.J., Cannom D.S., Daubert J.P., Higgins S.L., Brown M.W., and Andrews M.L. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346 12 (2002) 877-883
-
(2002)
N Engl J Med
, vol.346
, Issue.12
, pp. 877-883
-
-
Moss, A.J.1
Zareba, W.2
Hall, W.J.3
Klein, H.4
Wilber, D.J.5
Cannom, D.S.6
Daubert, J.P.7
Higgins, S.L.8
Brown, M.W.9
Andrews, M.L.10
-
10
-
-
33748751584
-
Left ventricle volume affects the result of mitral valve surgery for idiopathic dilated cardiomyopathy to treat congestive heart failure
-
Horii T., Suma H., Isomura T., Nomura F., and Hoshino J. Left ventricle volume affects the result of mitral valve surgery for idiopathic dilated cardiomyopathy to treat congestive heart failure. Ann Thorac Surg 82 4 (2006) 1349-1355
-
(2006)
Ann Thorac Surg
, vol.82
, Issue.4
, pp. 1349-1355
-
-
Horii, T.1
Suma, H.2
Isomura, T.3
Nomura, F.4
Hoshino, J.5
-
11
-
-
29344467976
-
Predictors of left ventricular performance after valve replacement in children and adolescents with chronic aortic regurgitation
-
Tafreshi R.I., Shahmohammadi A., and Davari P.N. Predictors of left ventricular performance after valve replacement in children and adolescents with chronic aortic regurgitation. Pediatr Cardiol 26 4 (2005) 331-337
-
(2005)
Pediatr Cardiol
, vol.26
, Issue.4
, pp. 331-337
-
-
Tafreshi, R.I.1
Shahmohammadi, A.2
Davari, P.N.3
-
12
-
-
0028877694
-
Should echocardiography be performed to assess effects of antihypertensive therapy? Test-retest reliability of echocardiography for measurement of left ventricular mass and function
-
Gottdiener J.S., Livengood S.V., Meyer P.S., and Chase G.A. Should echocardiography be performed to assess effects of antihypertensive therapy? Test-retest reliability of echocardiography for measurement of left ventricular mass and function. J Am Coll Cardiol 25 2 (1995) 424-430
-
(1995)
J Am Coll Cardiol
, vol.25
, Issue.2
, pp. 424-430
-
-
Gottdiener, J.S.1
Livengood, S.V.2
Meyer, P.S.3
Chase, G.A.4
-
13
-
-
33846427746
-
Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction
-
Jenkins C., Bricknell K., Chan J., Hanekom L., and Marwick T.H. Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol 99 3 (2007) 300-306
-
(2007)
Am J Cardiol
, vol.99
, Issue.3
, pp. 300-306
-
-
Jenkins, C.1
Bricknell, K.2
Chan, J.3
Hanekom, L.4
Marwick, T.H.5
-
14
-
-
4444381394
-
Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging
-
Malm S., Frigstad S., Sagberg E., Larsson H., and Skjaerpe T. Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 44 5 (2004) 1030-1035
-
(2004)
J Am Coll Cardiol
, vol.44
, Issue.5
, pp. 1030-1035
-
-
Malm, S.1
Frigstad, S.2
Sagberg, E.3
Larsson, H.4
Skjaerpe, T.5
-
15
-
-
0018677179
-
Comparative value of eight M-mode echocardiographic formulas for determining left ventricular stroke volume. A correlative study with thermodilution and left ventricular single-plane cineangiography
-
Kronik G., Slany J., and Mosslacher H. Comparative value of eight M-mode echocardiographic formulas for determining left ventricular stroke volume. A correlative study with thermodilution and left ventricular single-plane cineangiography. Circulation 60 6 (1979) 1308-1316
-
(1979)
Circulation
, vol.60
, Issue.6
, pp. 1308-1316
-
-
Kronik, G.1
Slany, J.2
Mosslacher, H.3
-
16
-
-
0024723470
-
Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
-
Schiller N.B., Shah P.M., Crawford M., DeMaria A., Devereux R., Feigenbaum H., Gutgesell H., Reichek N., Sahn D., Schnittger I., et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 2 5 (1989) 358-367
-
(1989)
J Am Soc Echocardiogr
, vol.2
, Issue.5
, pp. 358-367
-
-
Schiller, N.B.1
Shah, P.M.2
Crawford, M.3
DeMaria, A.4
Devereux, R.5
Feigenbaum, H.6
Gutgesell, H.7
Reichek, N.8
Sahn, D.9
Schnittger, I.10
-
17
-
-
0031254111
-
Freehand three-dimensional echocardiography for determination of left ventricular volume and mass in patients with abnormal ventricles: comparison with magnetic resonance imaging
-
Gopal A.S., Schnellbaecher M.J., Shen Z., Boxt L.M., Katz J., and King D.L. Freehand three-dimensional echocardiography for determination of left ventricular volume and mass in patients with abnormal ventricles: comparison with magnetic resonance imaging. J Am Soc Echocardiogr 10 8 (1997) 853-861
-
(1997)
J Am Soc Echocardiogr
, vol.10
, Issue.8
, pp. 853-861
-
-
Gopal, A.S.1
Schnellbaecher, M.J.2
Shen, Z.3
Boxt, L.M.4
Katz, J.5
King, D.L.6
-
18
-
-
0032758722
-
Real-time three-dimensional echocardiography for measurement of left ventricular volumes
-
Schmidt M.A., Ohazama C.J., Agyeman K.O., Freidlin R.Z., Jones M., Laurienzo J.M., Brenneman C.L., Arai A.E., von Ramm O.T., and Panza J.A. Real-time three-dimensional echocardiography for measurement of left ventricular volumes. Am J Cardiol 84 12 (1999) 1434-1439
-
(1999)
Am J Cardiol
, vol.84
, Issue.12
, pp. 1434-1439
-
-
Schmidt, M.A.1
Ohazama, C.J.2
Agyeman, K.O.3
Freidlin, R.Z.4
Jones, M.5
Laurienzo, J.M.6
Brenneman, C.L.7
Arai, A.E.8
von Ramm, O.T.9
Panza, J.A.10
-
19
-
-
33847126959
-
Real-time three-dimensional echocardiography: technological gadget or clinical tool?
-
Badano L.P., Dall'Armellina E., Monaghan M.J., Pepi M., Baldassi M., Cinello M., and Fioretti P.M. Real-time three-dimensional echocardiography: technological gadget or clinical tool?. J Cardiovasc Med (Hagerstown) 8 3 (2007) 144-162
-
(2007)
J Cardiovasc Med (Hagerstown)
, vol.8
, Issue.3
, pp. 144-162
-
-
Badano, L.P.1
Dall'Armellina, E.2
Monaghan, M.J.3
Pepi, M.4
Baldassi, M.5
Cinello, M.6
Fioretti, P.M.7
-
20
-
-
0028969005
-
Correspondence of left ventricular ejection fraction determinations from two-dimensional echocardiography, radionuclide angiography and contrast cineangiography
-
Naik M.M., Diamond G.A., Pai T., Soffer A., and Siegel R.J. Correspondence of left ventricular ejection fraction determinations from two-dimensional echocardiography, radionuclide angiography and contrast cineangiography. J Am Coll Cardiol 25 4 (1995) 937-942
-
(1995)
J Am Coll Cardiol
, vol.25
, Issue.4
, pp. 937-942
-
-
Naik, M.M.1
Diamond, G.A.2
Pai, T.3
Soffer, A.4
Siegel, R.J.5
-
21
-
-
0035070061
-
Lack of agreement between left ventricular volumes and ejection fraction determined by two-dimensional echocardiography and contrast cineangiography in postinfarction patients
-
Bernard Y., Meneveau N., Boucher S., Magnin D., Anguenot T., Schiele F., Vuillemenot A., and Bassand J.P. Lack of agreement between left ventricular volumes and ejection fraction determined by two-dimensional echocardiography and contrast cineangiography in postinfarction patients. Echocardiography 18 2 (2001) 113-122
-
(2001)
Echocardiography
, vol.18
, Issue.2
, pp. 113-122
-
-
Bernard, Y.1
Meneveau, N.2
Boucher, S.3
Magnin, D.4
Anguenot, T.5
Schiele, F.6
Vuillemenot, A.7
Bassand, J.P.8
-
22
-
-
0020573591
-
Variability in the measurement of regional left ventricular wall motion from contrast angiograms
-
Sheehan F.H., Stewart D.K., Dodge H.T., Mitten S., Bolson E.L., and Brown B.G. Variability in the measurement of regional left ventricular wall motion from contrast angiograms. Circulation 68 3 (1983) 550-559
-
(1983)
Circulation
, vol.68
, Issue.3
, pp. 550-559
-
-
Sheehan, F.H.1
Stewart, D.K.2
Dodge, H.T.3
Mitten, S.4
Bolson, E.L.5
Brown, B.G.6
-
23
-
-
0032439164
-
Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging
-
Iskandrian A.E., Germano G., VanDecker W., Ogilby J.D., Wolf N., Mintz R., and Berman D.S. Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging. J Nucl Cardiol 5 6 (1998) 574-578
-
(1998)
J Nucl Cardiol
, vol.5
, Issue.6
, pp. 574-578
-
-
Iskandrian, A.E.1
Germano, G.2
VanDecker, W.3
Ogilby, J.D.4
Wolf, N.5
Mintz, R.6
Berman, D.S.7
-
24
-
-
0034672579
-
Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy
-
Bax J.J., Lamb H., Dibbets P., Pelikan H., Boersma E., Viergever E.P., Germano G., Vliegen H.W., de Roos A., Pauwels E.K., and Van der Wall E.E. Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol 86 12 (2000) 1299-1305
-
(2000)
Am J Cardiol
, vol.86
, Issue.12
, pp. 1299-1305
-
-
Bax, J.J.1
Lamb, H.2
Dibbets, P.3
Pelikan, H.4
Boersma, E.5
Viergever, E.P.6
Germano, G.7
Vliegen, H.W.8
de Roos, A.9
Pauwels, E.K.10
Van der Wall, E.E.11
-
25
-
-
0035701238
-
Comparison of echocardiography with technetium 99m-gated single photon emission computed tomography as diagnostic tools for left ventricular ejection fraction
-
Choragudi N.L., Prakash A.M., Sun Y., Prasad P., Chiaramida S.A., and Lucariello R.J. Comparison of echocardiography with technetium 99m-gated single photon emission computed tomography as diagnostic tools for left ventricular ejection fraction. Echocardiography 18 8 (2001) 627-632
-
(2001)
Echocardiography
, vol.18
, Issue.8
, pp. 627-632
-
-
Choragudi, N.L.1
Prakash, A.M.2
Sun, Y.3
Prasad, P.4
Chiaramida, S.A.5
Lucariello, R.J.6
-
26
-
-
0028807605
-
Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
-
Germano G., Kiat H., Kavanagh P.B., Moriel M., Mazzanti M., Su H.T., Van Train K.F., and Berman D.S. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 36 11 (1995) 2138-2147
-
(1995)
J Nucl Med
, vol.36
, Issue.11
, pp. 2138-2147
-
-
Germano, G.1
Kiat, H.2
Kavanagh, P.B.3
Moriel, M.4
Mazzanti, M.5
Su, H.T.6
Van Train, K.F.7
Berman, D.S.8
-
27
-
-
0037134836
-
Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis
-
Ioannidis J.P., Trikalinos T.A., and Danias P.G. Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis. J Am Coll Cardiol 39 12 (2002) 2059-2068
-
(2002)
J Am Coll Cardiol
, vol.39
, Issue.12
, pp. 2059-2068
-
-
Ioannidis, J.P.1
Trikalinos, T.A.2
Danias, P.G.3
-
28
-
-
0034744441
-
Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function
-
Hyun I.Y., Kwan J., Park K.S., and Lee W.H. Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function. J Nucl Cardiol 8 2 (2001) 182-187
-
(2001)
J Nucl Cardiol
, vol.8
, Issue.2
, pp. 182-187
-
-
Hyun, I.Y.1
Kwan, J.2
Park, K.S.3
Lee, W.H.4
-
29
-
-
0032981643
-
Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT
-
DePuey E.G., Parmett S., Ghesani M., Rozanski A., Nichols K., and Salensky H. Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT. J Nucl Cardiol 6 3 (1999) 278-285
-
(1999)
J Nucl Cardiol
, vol.6
, Issue.3
, pp. 278-285
-
-
DePuey, E.G.1
Parmett, S.2
Ghesani, M.3
Rozanski, A.4
Nichols, K.5
Salensky, H.6
-
30
-
-
0141430927
-
Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT
-
Lum D.P., and Coel M.N. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 24 3 (2003) 259-266
-
(2003)
Nucl Med Commun
, vol.24
, Issue.3
, pp. 259-266
-
-
Lum, D.P.1
Coel, M.N.2
-
31
-
-
0036642629
-
Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
-
Grothues F., Smith G.C., Moon J.C., Bellenger N.G., Collins P., Klein H.U., and Pennell D.J. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90 1 (2002) 29-34
-
(2002)
Am J Cardiol
, vol.90
, Issue.1
, pp. 29-34
-
-
Grothues, F.1
Smith, G.C.2
Moon, J.C.3
Bellenger, N.G.4
Collins, P.5
Klein, H.U.6
Pennell, D.J.7
-
32
-
-
0029680221
-
Improved reproducibility in measuring LV volumes and mass using multicoil breath-hold cine MR imaging
-
Sakuma H., Globits S., Bourne M.W., Shimakawa A., Foo T.K., and Higgins C.B. Improved reproducibility in measuring LV volumes and mass using multicoil breath-hold cine MR imaging. J Magn Reson Imaging 6 1 (1996) 124-127
-
(1996)
J Magn Reson Imaging
, vol.6
, Issue.1
, pp. 124-127
-
-
Sakuma, H.1
Globits, S.2
Bourne, M.W.3
Shimakawa, A.4
Foo, T.K.5
Higgins, C.B.6
-
33
-
-
0021835512
-
Dimensional accuracy of magnetic resonance in studies of the heart
-
Longmore D.B., Klipstein R.H., Underwood S.R., Firmin D.N., Hounsfield G.N., Watanabe M., Bland C., Fox K., Poole-Wilson P.A., Rees R.S., et al. Dimensional accuracy of magnetic resonance in studies of the heart. Lancet 1 8442 (1985) 1360-1362
-
(1985)
Lancet
, vol.1
, Issue.8442
, pp. 1360-1362
-
-
Longmore, D.B.1
Klipstein, R.H.2
Underwood, S.R.3
Firmin, D.N.4
Hounsfield, G.N.5
Watanabe, M.6
Bland, C.7
Fox, K.8
Poole-Wilson, P.A.9
Rees, R.S.10
-
34
-
-
0034463626
-
Quantification of global and regional ventricular function in cardiac magnetic resonance imaging
-
van der Geest R.J., Lelieveldt B.P., and Reiber J.H. Quantification of global and regional ventricular function in cardiac magnetic resonance imaging. Top Magn Reson Imaging 11 6 (2000) 348-358
-
(2000)
Top Magn Reson Imaging
, vol.11
, Issue.6
, pp. 348-358
-
-
van der Geest, R.J.1
Lelieveldt, B.P.2
Reiber, J.H.3
-
35
-
-
1642290209
-
Assessment of myocardial function with interactive non-breath-hold real-time MR imaging: comparison with echocardiography and breath-hold Cine MR imaging
-
Kuhl H.P., Spuentrup E., Wall A., Franke A., Schroder J., Heussen N., Hanrath P., Gunther R.W., and Buecker A. Assessment of myocardial function with interactive non-breath-hold real-time MR imaging: comparison with echocardiography and breath-hold Cine MR imaging. Radiology 231 1 (2004) 198-207
-
(2004)
Radiology
, vol.231
, Issue.1
, pp. 198-207
-
-
Kuhl, H.P.1
Spuentrup, E.2
Wall, A.3
Franke, A.4
Schroder, J.5
Heussen, N.6
Hanrath, P.7
Gunther, R.W.8
Buecker, A.9
-
36
-
-
21044440990
-
Assessment of reperfused acute myocardial infarction with two-phase contrast-enhanced helical CT: prediction of left ventricular function and wall thickness
-
Koyama Y., Matsuoka H., Mochizuki T., Higashino H., Kawakami H., Nakata S., Aono J., Ito T., Naka M., Ohashi Y., and Higaki J. Assessment of reperfused acute myocardial infarction with two-phase contrast-enhanced helical CT: prediction of left ventricular function and wall thickness. Radiology 235 3 (2005) 804-811
-
(2005)
Radiology
, vol.235
, Issue.3
, pp. 804-811
-
-
Koyama, Y.1
Matsuoka, H.2
Mochizuki, T.3
Higashino, H.4
Kawakami, H.5
Nakata, S.6
Aono, J.7
Ito, T.8
Naka, M.9
Ohashi, Y.10
Higaki, J.11
-
37
-
-
33947145306
-
Acute myocardial infarction early viability assessment by 64-slice computed tomography immediately after coronary angiography: comparison with low-dose dobutamine echocardiography
-
Habis M., Capderou A., Ghostine S., Daoud B., Caussin C., Riou J.Y., Brenot P., Angel C.Y., Lancelin B., and Paul J.F. Acute myocardial infarction early viability assessment by 64-slice computed tomography immediately after coronary angiography: comparison with low-dose dobutamine echocardiography. J Am Coll Cardiol 49 11 (2007) 1178-1185
-
(2007)
J Am Coll Cardiol
, vol.49
, Issue.11
, pp. 1178-1185
-
-
Habis, M.1
Capderou, A.2
Ghostine, S.3
Daoud, B.4
Caussin, C.5
Riou, J.Y.6
Brenot, P.7
Angel, C.Y.8
Lancelin, B.9
Paul, J.F.10
-
38
-
-
0035176983
-
Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm
-
Horiguchi J., Nakanishi T., and Ito K. Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm. AJR Am J Roentgenol 177 6 (2001) 1429-1435
-
(2001)
AJR Am J Roentgenol
, vol.177
, Issue.6
, pp. 1429-1435
-
-
Horiguchi, J.1
Nakanishi, T.2
Ito, K.3
-
39
-
-
0036206953
-
MR imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters
-
Miller S., Simonetti O.P., Carr J., Kramer U., and Finn J.P. MR imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 223 1 (2002) 263-269
-
(2002)
Radiology
, vol.223
, Issue.1
, pp. 263-269
-
-
Miller, S.1
Simonetti, O.P.2
Carr, J.3
Kramer, U.4
Finn, J.P.5
-
40
-
-
0036651194
-
Search for isotropic resolution in CT from conventional through multiple-row detector
-
Mahesh M. Search for isotropic resolution in CT from conventional through multiple-row detector. Radiographics 22 4 (2002) 949-962
-
(2002)
Radiographics
, vol.22
, Issue.4
, pp. 949-962
-
-
Mahesh, M.1
-
41
-
-
42449124018
-
Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: phantom validation
-
Sabir A., Yam C.S., Yoshimura N., Buros J.L., De Grand A.M., Raptopoulos V., and Clouse M.E. Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: phantom validation. AJR Am J Roentgenol 190 4 (2008) W242-W246
-
(2008)
AJR Am J Roentgenol
, vol.190
, Issue.4
-
-
Sabir, A.1
Yam, C.S.2
Yoshimura, N.3
Buros, J.L.4
De Grand, A.M.5
Raptopoulos, V.6
Clouse, M.E.7
-
42
-
-
0033845492
-
Quantification of left ventricular function with magnetic resonance images acquired in real time
-
Setser R.M., Fischer S.E., and Lorenz C.H. Quantification of left ventricular function with magnetic resonance images acquired in real time. J Magn Reson Imaging 12 3 (2000) 430-438
-
(2000)
J Magn Reson Imaging
, vol.12
, Issue.3
, pp. 430-438
-
-
Setser, R.M.1
Fischer, S.E.2
Lorenz, C.H.3
-
43
-
-
0026738437
-
Minimum scan speeds for suppression of motion artifacts in CT
-
Ritchie C.J., Godwin J.D., Crawford C.R., Stanford W., Anno H., and Kim Y. Minimum scan speeds for suppression of motion artifacts in CT. Radiology 185 1 (1992) 37-42
-
(1992)
Radiology
, vol.185
, Issue.1
, pp. 37-42
-
-
Ritchie, C.J.1
Godwin, J.D.2
Crawford, C.R.3
Stanford, W.4
Anno, H.5
Kim, Y.6
-
44
-
-
0033753104
-
Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience
-
Ohnesorge B., Flohr T., Becker C., Kopp A.F., Schoepf U.J., Baum U., Knez A., Klingenbeck-Regn K., and Reiser M.F. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217 2 (2000) 564-571
-
(2000)
Radiology
, vol.217
, Issue.2
, pp. 564-571
-
-
Ohnesorge, B.1
Flohr, T.2
Becker, C.3
Kopp, A.F.4
Schoepf, U.J.5
Baum, U.6
Knez, A.7
Klingenbeck-Regn, K.8
Reiser, M.F.9
-
45
-
-
0034137161
-
Optimizing temporal resolution in CT with retrospective ECG gating [in German]
-
Boese J.M., Bahner M.L., Albers J., and van Kaick G. Optimizing temporal resolution in CT with retrospective ECG gating [in German]. Radiologe 40 2 (2000) 123-129
-
(2000)
Radiologe
, vol.40
, Issue.2
, pp. 123-129
-
-
Boese, J.M.1
Bahner, M.L.2
Albers, J.3
van Kaick, G.4
-
46
-
-
0035176903
-
Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
-
Flohr T., and Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25 6 (2001) 907-923
-
(2001)
J Comput Assist Tomogr
, vol.25
, Issue.6
, pp. 907-923
-
-
Flohr, T.1
Ohnesorge, B.2
-
47
-
-
14644388731
-
Functional cardiac CT and MR: effects of heart rate and software applications on measurement validity
-
Boll D.T., Gilkeson R.C., Merkle E.M., Fleiter T.R., Duerk J.L., and Lewin J.S. Functional cardiac CT and MR: effects of heart rate and software applications on measurement validity. J Thorac Imaging 20 1 (2005) 10-16
-
(2005)
J Thorac Imaging
, vol.20
, Issue.1
, pp. 10-16
-
-
Boll, D.T.1
Gilkeson, R.C.2
Merkle, E.M.3
Fleiter, T.R.4
Duerk, J.L.5
Lewin, J.S.6
-
48
-
-
0345689655
-
Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI
-
Mahnken A.H., Spuentrup E., Niethammer M., Buecker A., Boese J., Wildberger J.E., Flohr T., Sinha A.M., Krombach G.A., and Gunther R.W. Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol 44 6 (2003) 604-611
-
(2003)
Acta Radiol
, vol.44
, Issue.6
, pp. 604-611
-
-
Mahnken, A.H.1
Spuentrup, E.2
Niethammer, M.3
Buecker, A.4
Boese, J.5
Wildberger, J.E.6
Flohr, T.7
Sinha, A.M.8
Krombach, G.A.9
Gunther, R.W.10
-
49
-
-
12144250963
-
Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?
-
Juergens K.U., Maintz D., Grude M., Boese J.M., Heimes B., Fallenberg E.M., Heindel W., and Fischbach R. Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?. Eur Radiol 15 1 (2005) 111-117
-
(2005)
Eur Radiol
, vol.15
, Issue.1
, pp. 111-117
-
-
Juergens, K.U.1
Maintz, D.2
Grude, M.3
Boese, J.M.4
Heimes, B.5
Fallenberg, E.M.6
Heindel, W.7
Fischbach, R.8
-
50
-
-
33746663053
-
Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study
-
Mahnken A.H., Hohl C., Suess C., Bruder H., Muhlenbruch G., Das M., Gunther R.W., and Wildberger J.E. Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study. Invest Radiol 41 5 (2006) 429-435
-
(2006)
Invest Radiol
, vol.41
, Issue.5
, pp. 429-435
-
-
Mahnken, A.H.1
Hohl, C.2
Suess, C.3
Bruder, H.4
Muhlenbruch, G.5
Das, M.6
Gunther, R.W.7
Wildberger, J.E.8
-
51
-
-
33749064744
-
Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function
-
Schepis T., Gaemperli O., Koepfli P., Valenta I., Strobel K., Brunner A., Leschka S., Desbiolles L., Husmann L., Alkadhi H., and Kaufmann P. Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med 47 8 (2006) 1288-1294
-
(2006)
J Nucl Med
, vol.47
, Issue.8
, pp. 1288-1294
-
-
Schepis, T.1
Gaemperli, O.2
Koepfli, P.3
Valenta, I.4
Strobel, K.5
Brunner, A.6
Leschka, S.7
Desbiolles, L.8
Husmann, L.9
Alkadhi, H.10
Kaufmann, P.11
-
52
-
-
37349062021
-
Assessment of global left and right ventricular function using dual-source computed tomography (DSCT) in comparison to MRI: an experimental study in a porcine model
-
Bruners P., Mahnken A.H., Knackstedt C., Luhmann N., Spuntrup E., Das M., Hohl C., Wildberger J.E., Schmitz-Rode T., Gunther R.W., and Muhlenbruch G. Assessment of global left and right ventricular function using dual-source computed tomography (DSCT) in comparison to MRI: an experimental study in a porcine model. Invest Radiol 42 11 (2007) 756-764
-
(2007)
Invest Radiol
, vol.42
, Issue.11
, pp. 756-764
-
-
Bruners, P.1
Mahnken, A.H.2
Knackstedt, C.3
Luhmann, N.4
Spuntrup, E.5
Das, M.6
Hohl, C.7
Wildberger, J.E.8
Schmitz-Rode, T.9
Gunther, R.W.10
Muhlenbruch, G.11
-
53
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
Flohr T.G., McCollough C.H., Bruder H., Petersilka M., Gruber K., Suss C., Grasruck M., Stierstorfer K., Krauss B., Raupach R., Primak A.N., Kuttner A., Achenbach S., Becker C., Kopp A., and Ohnesorge B.M. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 2 (2006) 256-268
-
(2006)
Eur Radiol
, vol.16
, Issue.2
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
Petersilka, M.4
Gruber, K.5
Suss, C.6
Grasruck, M.7
Stierstorfer, K.8
Krauss, B.9
Raupach, R.10
Primak, A.N.11
Kuttner, A.12
Achenbach, S.13
Becker, C.14
Kopp, A.15
Ohnesorge, B.M.16
-
54
-
-
40349094459
-
New applications for noninvasive cardiac imaging: dual-source computed tomography
-
Rist C., Johnson T.R., Becker C.R., Reiser M.F., and Nikolaou K. New applications for noninvasive cardiac imaging: dual-source computed tomography. Eur Radiol 17 Suppl 6 (2007) F16-F25
-
(2007)
Eur Radiol
, vol.17
, Issue.SUPPL. 6
-
-
Rist, C.1
Johnson, T.R.2
Becker, C.R.3
Reiser, M.F.4
Nikolaou, K.5
-
55
-
-
35649008388
-
Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study
-
Brodoefel H., Kramer U., Reimann A., Burgstahler C., Schroeder S., Kopp A., and Heuschmid M. Dual-source CT with improved temporal resolution in assessment of left ventricular function: a pilot study. AJR Am J Roentgenol 189 5 (2007) 1064-1070
-
(2007)
AJR Am J Roentgenol
, vol.189
, Issue.5
, pp. 1064-1070
-
-
Brodoefel, H.1
Kramer, U.2
Reimann, A.3
Burgstahler, C.4
Schroeder, S.5
Kopp, A.6
Heuschmid, M.7
-
56
-
-
34249023378
-
Dose performance of a 64-channel dual-source CT scanner
-
McCollough C.H., Primak A.N., Saba O., Bruder H., Stierstorfer K., Raupach R., Suess C., Schmidt B., Ohnesorge B.M., and Flohr T.G. Dose performance of a 64-channel dual-source CT scanner. Radiology 243 3 (2007) 775-784
-
(2007)
Radiology
, vol.243
, Issue.3
, pp. 775-784
-
-
McCollough, C.H.1
Primak, A.N.2
Saba, O.3
Bruder, H.4
Stierstorfer, K.5
Raupach, R.6
Suess, C.7
Schmidt, B.8
Ohnesorge, B.M.9
Flohr, T.G.10
-
57
-
-
39049158286
-
Radiation dose estimates in dual-source computed tomography coronary angiography
-
Stolzmann P., Scheffel H., Schertler T., Frauenfelder T., Leschka S., Husmann L., Flohr T.G., Marincek B., Kaufmann P.A., and Alkadhi H. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18 3 (2008) 592-599
-
(2008)
Eur Radiol
, vol.18
, Issue.3
, pp. 592-599
-
-
Stolzmann, P.1
Scheffel, H.2
Schertler, T.3
Frauenfelder, T.4
Leschka, S.5
Husmann, L.6
Flohr, T.G.7
Marincek, B.8
Kaufmann, P.A.9
Alkadhi, H.10
-
58
-
-
33750487848
-
Retrospective ECG-gated left ventriculography using multislice CT following left ventricular bolus injection and evaluation of its utility and motion artifact at every cardiac phase
-
Funabashi N., Komiyama N., Kato H., Umekita H., Asano M., and Komuro I. Retrospective ECG-gated left ventriculography using multislice CT following left ventricular bolus injection and evaluation of its utility and motion artifact at every cardiac phase. Int J Cardiol 113 1 (2006) 132-138
-
(2006)
Int J Cardiol
, vol.113
, Issue.1
, pp. 132-138
-
-
Funabashi, N.1
Komiyama, N.2
Kato, H.3
Umekita, H.4
Asano, M.5
Komuro, I.6
-
59
-
-
0347533854
-
Optimal contrast application for cardiac 4-detector-row computed tomography
-
Becker C.R., Hong C., Knez A., Leber A., Bruening R., Schoepf U.J., and Reiser M.F. Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 38 11 (2003) 690-694
-
(2003)
Invest Radiol
, vol.38
, Issue.11
, pp. 690-694
-
-
Becker, C.R.1
Hong, C.2
Knez, A.3
Leber, A.4
Bruening, R.5
Schoepf, U.J.6
Reiser, M.F.7
-
60
-
-
33746700916
-
Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter
-
Rist C., Nikolaou K., Kirchin M.A., van Gessel R., Bae K.T., von Ziegler F., Knez A., Wintersperger B.J., Reiser M.F., and Becker C.R. Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter. Invest Radiol 41 5 (2006) 460-467
-
(2006)
Invest Radiol
, vol.41
, Issue.5
, pp. 460-467
-
-
Rist, C.1
Nikolaou, K.2
Kirchin, M.A.3
van Gessel, R.4
Bae, K.T.5
von Ziegler, F.6
Knez, A.7
Wintersperger, B.J.8
Reiser, M.F.9
Becker, C.R.10
-
61
-
-
33745879781
-
High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400
-
Cademartiri F., de Monye C., Pugliese F., Mollet N.R., Runza G., van der Lugt A., Midiri M., de Feyter P.J., Lagalla R., and Krestin G.P. High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 41 3 (2006) 349-353
-
(2006)
Invest Radiol
, vol.41
, Issue.3
, pp. 349-353
-
-
Cademartiri, F.1
de Monye, C.2
Pugliese, F.3
Mollet, N.R.4
Runza, G.5
van der Lugt, A.6
Midiri, M.7
de Feyter, P.J.8
Lagalla, R.9
Krestin, G.P.10
-
62
-
-
33748471944
-
Cardiac 16-MDCT for anatomic and functional analysis: assessment of a biphasic contrast injection protocol
-
Utsunomiya D., Awai K., Sakamoto T., Nishiharu T., Urata J., Taniguchi A., Nakaura T., and Yamashita Y. Cardiac 16-MDCT for anatomic and functional analysis: assessment of a biphasic contrast injection protocol. AJR Am J Roentgenol 187 3 (2006) 638-644
-
(2006)
AJR Am J Roentgenol
, vol.187
, Issue.3
, pp. 638-644
-
-
Utsunomiya, D.1
Awai, K.2
Sakamoto, T.3
Nishiharu, T.4
Urata, J.5
Taniguchi, A.6
Nakaura, T.7
Yamashita, Y.8
-
63
-
-
31944448689
-
Intravenous contrast material administration in multislice computed tomography coronary angiography
-
Cademartiri F., Luccichenti G., Gualerzi M., Brambilla L., Brambilla V., and Coruzzi P. Intravenous contrast material administration in multislice computed tomography coronary angiography. Acta Biomed 76 2 (2005) 86-94
-
(2005)
Acta Biomed
, vol.76
, Issue.2
, pp. 86-94
-
-
Cademartiri, F.1
Luccichenti, G.2
Gualerzi, M.3
Brambilla, L.4
Brambilla, V.5
Coruzzi, P.6
-
64
-
-
0842302434
-
Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser
-
Cademartiri F., Mollet N., van der Lugt A., Nieman K., Pattynama P.M., de Feyter P.J., and Krestin G.P. Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 14 2 (2004) 178-183
-
(2004)
Eur Radiol
, vol.14
, Issue.2
, pp. 178-183
-
-
Cademartiri, F.1
Mollet, N.2
van der Lugt, A.3
Nieman, K.4
Pattynama, P.M.5
de Feyter, P.J.6
Krestin, G.P.7
-
65
-
-
3142772606
-
Use of saline chaser in the intravenous administration of contrast material in non-invasive coronary angiography with 16-row multislice Computed Tomography
-
Cademartiri F., Luccichenti G., Marano R., Runza G., and Midiri M. Use of saline chaser in the intravenous administration of contrast material in non-invasive coronary angiography with 16-row multislice Computed Tomography. Radiol Med (Torino) 107 5-6 (2004) 497-505
-
(2004)
Radiol Med (Torino)
, vol.107
, Issue.5-6
, pp. 497-505
-
-
Cademartiri, F.1
Luccichenti, G.2
Marano, R.3
Runza, G.4
Midiri, M.5
-
66
-
-
50949087072
-
Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols
-
Nakaura T., Awai K., Yauaga Y., Nakayama Y., Oda S., Hatemura M., Nagayoshi Y., Ogawa H., and Yamashita Y. Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol 43 7 (2008) 512-519
-
(2008)
Invest Radiol
, vol.43
, Issue.7
, pp. 512-519
-
-
Nakaura, T.1
Awai, K.2
Yauaga, Y.3
Nakayama, Y.4
Oda, S.5
Hatemura, M.6
Nagayoshi, Y.7
Ogawa, H.8
Yamashita, Y.9
-
67
-
-
3342875542
-
Computed tomography contrast enhancement principles and the use of high-concentration contrast media
-
Herman S. Computed tomography contrast enhancement principles and the use of high-concentration contrast media. J Comput Assist Tomogr 28 Suppl 1 (2004) S7-S11
-
(2004)
J Comput Assist Tomogr
, vol.28
, Issue.SUPPL. 1
-
-
Herman, S.1
-
68
-
-
16544371386
-
Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique
-
Cademartiri F., Nieman K., van der Lugt A., Raaijmakers R.H., Mollet N., Pattynama P.M., de Feyter P.J., and Krestin G.P. Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233 3 (2004) 817-823
-
(2004)
Radiology
, vol.233
, Issue.3
, pp. 817-823
-
-
Cademartiri, F.1
Nieman, K.2
van der Lugt, A.3
Raaijmakers, R.H.4
Mollet, N.5
Pattynama, P.M.6
de Feyter, P.J.7
Krestin, G.P.8
-
69
-
-
0141478720
-
Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging
-
Grude M., Juergens K.U., Wichter T., Paul M., Fallenberg E.M., Muller J.G., Heindel W., Breithardt G., and Fischbach R. Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging. Invest Radiol 38 10 (2003) 653-661
-
(2003)
Invest Radiol
, vol.38
, Issue.10
, pp. 653-661
-
-
Grude, M.1
Juergens, K.U.2
Wichter, T.3
Paul, M.4
Fallenberg, E.M.5
Muller, J.G.6
Heindel, W.7
Breithardt, G.8
Fischbach, R.9
-
70
-
-
33747431187
-
Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
-
Sugeng L., Mor-Avi V., Weinert L., Niel J., Ebner C., Steringer-Mascherbauer R., Schmidt F., Galuschky C., Schummers G., Lang R.M., and Nesser H.J. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation 114 7 (2006) 654-661
-
(2006)
Circulation
, vol.114
, Issue.7
, pp. 654-661
-
-
Sugeng, L.1
Mor-Avi, V.2
Weinert, L.3
Niel, J.4
Ebner, C.5
Steringer-Mascherbauer, R.6
Schmidt, F.7
Galuschky, C.8
Schummers, G.9
Lang, R.M.10
Nesser, H.J.11
-
71
-
-
79551689848
-
Rawdata-based detection of the optimal reconstruction phase in ECG-gated cardiac image reconstruction
-
Ertel D., Kachelriess M., Pflederer T., Achenbach S., Lapp R.M., Nagel M., and Kalender W.A. Rawdata-based detection of the optimal reconstruction phase in ECG-gated cardiac image reconstruction. Med Image Comput Comput Assist Interv Int Conf Med Image Comput Comput Assist Interv 9 Pt 2 (2006) 348-355
-
(2006)
Med Image Comput Comput Assist Interv Int Conf Med Image Comput Comput Assist Interv
, vol.9
, Issue.PART 2
, pp. 348-355
-
-
Ertel, D.1
Kachelriess, M.2
Pflederer, T.3
Achenbach, S.4
Lapp, R.M.5
Nagel, M.6
Kalender, W.A.7
-
72
-
-
52049107375
-
Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement
-
Puesken M., Fischbach R., Wenker M., Seifarth H., Maintz D., Heindel W., and Juergens K.U. Global left-ventricular function assessment using dual-source multidetector CT: effect of improved temporal resolution on ventricular volume measurement. Eur Radiol 18 10 (2008) 2087-2094
-
(2008)
Eur Radiol
, vol.18
, Issue.10
, pp. 2087-2094
-
-
Puesken, M.1
Fischbach, R.2
Wenker, M.3
Seifarth, H.4
Maintz, D.5
Heindel, W.6
Juergens, K.U.7
-
73
-
-
25644446163
-
Two-phase reconstruction for the assessment of left ventricular volume and function using retrospective ECG-gated MDCT: comparison with echocardiography
-
Kim T.H., Hur J., Kim S.J., Kim H.S., Choi B.W., Choe K.O., Yoon Y.W., and Kwon H.M. Two-phase reconstruction for the assessment of left ventricular volume and function using retrospective ECG-gated MDCT: comparison with echocardiography. AJR Am J Roentgenol 185 2 (2005) 319-325
-
(2005)
AJR Am J Roentgenol
, vol.185
, Issue.2
, pp. 319-325
-
-
Kim, T.H.1
Hur, J.2
Kim, S.J.3
Kim, H.S.4
Choi, B.W.5
Choe, K.O.6
Yoon, Y.W.7
Kwon, H.M.8
-
74
-
-
0036885007
-
Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease
-
Juergens K.U., Grude M., Fallenberg E.M., Opitz C., Wichter T., Heindel W., and Fischbach R. Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease. AJR Am J Roentgenol 179 6 (2002) 1545-1550
-
(2002)
AJR Am J Roentgenol
, vol.179
, Issue.6
, pp. 1545-1550
-
-
Juergens, K.U.1
Grude, M.2
Fallenberg, E.M.3
Opitz, C.4
Wichter, T.5
Heindel, W.6
Fischbach, R.7
-
75
-
-
19944430288
-
Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging
-
Yamamuro M., Tadamura E., Kubo S., Toyoda H., Nishina T., Ohba M., Hosokawa R., Kimura T., Tamaki N., Komeda M., Kita T., and Konishi J. Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging. Radiology 234 2 (2005) 381-390
-
(2005)
Radiology
, vol.234
, Issue.2
, pp. 381-390
-
-
Yamamuro, M.1
Tadamura, E.2
Kubo, S.3
Toyoda, H.4
Nishina, T.5
Ohba, M.6
Hosokawa, R.7
Kimura, T.8
Tamaki, N.9
Komeda, M.10
Kita, T.11
Konishi, J.12
-
76
-
-
33846924519
-
Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography
-
Schuijf J.D., Bax J.J., Jukema J.W., Lamb H.J., Salm L.P., de Roos A., and van der Wall E.E. Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography. Int J Cardiol 116 2 (2007) 201-205
-
(2007)
Int J Cardiol
, vol.116
, Issue.2
, pp. 201-205
-
-
Schuijf, J.D.1
Bax, J.J.2
Jukema, J.W.3
Lamb, H.J.4
Salm, L.P.5
de Roos, A.6
van der Wall, E.E.7
-
77
-
-
33750945800
-
Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging
-
Dewey M., Muller M., Eddicks S., Schnapauff D., Teige F., Rutsch W., Borges A.C., and Hamm B. Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging. J Am Coll Cardiol 48 10 (2006) 2034-2044
-
(2006)
J Am Coll Cardiol
, vol.48
, Issue.10
, pp. 2034-2044
-
-
Dewey, M.1
Muller, M.2
Eddicks, S.3
Schnapauff, D.4
Teige, F.5
Rutsch, W.6
Borges, A.C.7
Hamm, B.8
-
78
-
-
33745577939
-
MDCT determination of volume and function of the left ventricle: are short-axis image reformations necessary?
-
Juergens K.U., Seifarth H., Maintz D., Grude M., Ozgun M., Wichter T., Heindel W., and Fischbach R. MDCT determination of volume and function of the left ventricle: are short-axis image reformations necessary?. AJR Am J Roentgenol 186 6 Suppl. 2 (2006) S371-S378
-
(2006)
AJR Am J Roentgenol
, vol.186
, Issue.6 SUPPL. 2
-
-
Juergens, K.U.1
Seifarth, H.2
Maintz, D.3
Grude, M.4
Ozgun, M.5
Wichter, T.6
Heindel, W.7
Fischbach, R.8
-
79
-
-
1642499210
-
Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience
-
Juergens K.U., Grude M., Maintz D., Fallenberg E.M., Wichter T., Heindel W., and Fischbach R. Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience. Radiology 230 2 (2004) 403-410
-
(2004)
Radiology
, vol.230
, Issue.2
, pp. 403-410
-
-
Juergens, K.U.1
Grude, M.2
Maintz, D.3
Fallenberg, E.M.4
Wichter, T.5
Heindel, W.6
Fischbach, R.7
-
80
-
-
33746185707
-
Multi-slice computer tomography of left ventricular function with automated analysis software in comparison with conventional ventriculography
-
Gilard M., Pennec P.Y., Cornily J.C., Vinsonneau U., Le Gal G., Nonent M., Mansourati J., and Boschat J. Multi-slice computer tomography of left ventricular function with automated analysis software in comparison with conventional ventriculography. Eur J Radiol 59 2 (2006) 270-275
-
(2006)
Eur J Radiol
, vol.59
, Issue.2
, pp. 270-275
-
-
Gilard, M.1
Pennec, P.Y.2
Cornily, J.C.3
Vinsonneau, U.4
Le Gal, G.5
Nonent, M.6
Mansourati, J.7
Boschat, J.8
-
81
-
-
38849175599
-
Automated threshold-based 3D segmentation versus short-axis planimetry for assessment of global left ventricular function with dual-source MDCT
-
Juergens K.U., Seifarth H., Range F., Wienbeck S., Wenker M., Heindel W., and Fischbach R. Automated threshold-based 3D segmentation versus short-axis planimetry for assessment of global left ventricular function with dual-source MDCT. AJR Am J Roentgenol 190 2 (2008) 308-314
-
(2008)
AJR Am J Roentgenol
, vol.190
, Issue.2
, pp. 308-314
-
-
Juergens, K.U.1
Seifarth, H.2
Range, F.3
Wienbeck, S.4
Wenker, M.5
Heindel, W.6
Fischbach, R.7
-
82
-
-
33846094611
-
Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure
-
Butler J., Shapiro M.D., Jassal D.S., Neilan T.G., Nichols J., Ferencik M., Brady T.J., Hoffmann U., and Cury R.C. Comparison of multidetector computed tomography and two-dimensional transthoracic echocardiography for left ventricular assessment in patients with heart failure. Am J Cardiol 99 2 (2007) 247-249
-
(2007)
Am J Cardiol
, vol.99
, Issue.2
, pp. 247-249
-
-
Butler, J.1
Shapiro, M.D.2
Jassal, D.S.3
Neilan, T.G.4
Nichols, J.5
Ferencik, M.6
Brady, T.J.7
Hoffmann, U.8
Cury, R.C.9
-
83
-
-
0037192118
-
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
-
Cerqueira M.D., Weissman N.J., Dilsizian V., Jacobs A.K., Kaul S., Laskey W.K., Pennell D.J., Rumberger J.A., Ryan T., and Verani M.S. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105 4 (2002) 539-542
-
(2002)
Circulation
, vol.105
, Issue.4
, pp. 539-542
-
-
Cerqueira, M.D.1
Weissman, N.J.2
Dilsizian, V.3
Jacobs, A.K.4
Kaul, S.5
Laskey, W.K.6
Pennell, D.J.7
Rumberger, J.A.8
Ryan, T.9
Verani, M.S.10
-
84
-
-
9444223853
-
Noninvasive angiography and assessment of left ventricular function using multislice computed tomography in patients with type 2 diabetes
-
Schuijf J.D., Bax J.J., Jukema J.W., Lamb H.J., Vliegen H.W., Salm L.P., de Roos A., and van der Wall E.E. Noninvasive angiography and assessment of left ventricular function using multislice computed tomography in patients with type 2 diabetes. Diabetes Care 27 12 (2004) 2905-2910
-
(2004)
Diabetes Care
, vol.27
, Issue.12
, pp. 2905-2910
-
-
Schuijf, J.D.1
Bax, J.J.2
Jukema, J.W.3
Lamb, H.J.4
Vliegen, H.W.5
Salm, L.P.6
de Roos, A.7
van der Wall, E.E.8
-
85
-
-
25444508455
-
Comparison of multidetector computed tomography versus echocardiography for assessing regional left ventricular function
-
Lessick J., Mutlak D., Rispler S., Ghersin E., Dragu R., Litmanovich D., Engel A., Reisner S.A., and Agmon Y. Comparison of multidetector computed tomography versus echocardiography for assessing regional left ventricular function. Am J Cardiol 96 7 (2005) 1011-1015
-
(2005)
Am J Cardiol
, vol.96
, Issue.7
, pp. 1011-1015
-
-
Lessick, J.1
Mutlak, D.2
Rispler, S.3
Ghersin, E.4
Dragu, R.5
Litmanovich, D.6
Engel, A.7
Reisner, S.A.8
Agmon, Y.9
-
86
-
-
33747022502
-
Assessment of global and regional left ventricular function and volumes with 64-slice MSCT: a comparison with 2D echocardiography
-
Henneman M.M., Schuijf J.D., Jukema J.W., Holman E.R., Lamb H.J., de Roos A., van der Wall E.E., and Bax J.J. Assessment of global and regional left ventricular function and volumes with 64-slice MSCT: a comparison with 2D echocardiography. J Nucl Cardiol 13 4 (2006) 480-487
-
(2006)
J Nucl Cardiol
, vol.13
, Issue.4
, pp. 480-487
-
-
Henneman, M.M.1
Schuijf, J.D.2
Jukema, J.W.3
Holman, E.R.4
Lamb, H.J.5
de Roos, A.6
van der Wall, E.E.7
Bax, J.J.8
-
87
-
-
33745656204
-
Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance
-
Salm L.P., Schuijf J.D., de Roos A., Lamb H.J., Vliegen H.W., Jukema J.W., Joemai R., van der Wall E.E., and Bax J.J. Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr 7 4 (2006) 308-314
-
(2006)
Eur J Echocardiogr
, vol.7
, Issue.4
, pp. 308-314
-
-
Salm, L.P.1
Schuijf, J.D.2
de Roos, A.3
Lamb, H.J.4
Vliegen, H.W.5
Jukema, J.W.6
Joemai, R.7
van der Wall, E.E.8
Bax, J.J.9
-
88
-
-
0037112104
-
Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography
-
Dirksen M.S., Bax J.J., de Roos A., Jukema J.W., van der Geest R.J., Geleijns K., Boersma E., van der Wall E.E., and Lamb H.J. Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography. Am J Cardiol 90 10 (2002) 1157-1160
-
(2002)
Am J Cardiol
, vol.90
, Issue.10
, pp. 1157-1160
-
-
Dirksen, M.S.1
Bax, J.J.2
de Roos, A.3
Jukema, J.W.4
van der Geest, R.J.5
Geleijns, K.6
Boersma, E.7
van der Wall, E.E.8
Lamb, H.J.9
-
89
-
-
0344826035
-
Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT): phantom and human studies
-
Hosoi S., Mochizuki T., Miyagawa M., Shen Y., Murase K., and Ikezoe J. Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT): phantom and human studies. Radiat Med 21 2 (2003) 62-67
-
(2003)
Radiat Med
, vol.21
, Issue.2
, pp. 62-67
-
-
Hosoi, S.1
Mochizuki, T.2
Miyagawa, M.3
Shen, Y.4
Murase, K.5
Ikezoe, J.6
-
90
-
-
19544387779
-
Assessment of global left ventricular function: comparison of cardiac multidetector-row computed tomography with angiocardiography
-
Hundt W., Siebert K., Wintersperger B.J., Becker C.R., Knez A., Reiser M.F., and Rubin G.D. Assessment of global left ventricular function: comparison of cardiac multidetector-row computed tomography with angiocardiography. J Comput Assist Tomogr 29 3 (2005) 373-381
-
(2005)
J Comput Assist Tomogr
, vol.29
, Issue.3
, pp. 373-381
-
-
Hundt, W.1
Siebert, K.2
Wintersperger, B.J.3
Becker, C.R.4
Knez, A.5
Reiser, M.F.6
Rubin, G.D.7
-
91
-
-
34247856049
-
Accurate estimation of regional and global cardiac function in old myocardial infarction patients by multidetector-row computed tomography
-
Yamaguchi K., Nomura M., Tsujikawa T., Koshiba K., and Ito S. Accurate estimation of regional and global cardiac function in old myocardial infarction patients by multidetector-row computed tomography. J Med Invest 54 1-2 (2007) 72-82
-
(2007)
J Med Invest
, vol.54
, Issue.1-2
, pp. 72-82
-
-
Yamaguchi, K.1
Nomura, M.2
Tsujikawa, T.3
Koshiba, K.4
Ito, S.5
-
92
-
-
34250829739
-
Quantification of right and left ventricular volumes in children with congenital heart disease by multidetector-row computed tomography
-
Matsui H., Yasukochi S., Haseyama K., Kaneko S., and Satomi G. Quantification of right and left ventricular volumes in children with congenital heart disease by multidetector-row computed tomography. Pediatr Cardiol 28 4 (2007) 267-271
-
(2007)
Pediatr Cardiol
, vol.28
, Issue.4
, pp. 267-271
-
-
Matsui, H.1
Yasukochi, S.2
Haseyama, K.3
Kaneko, S.4
Satomi, G.5
-
93
-
-
33344469809
-
Multi-detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonance
-
Raman S.V., Shah M., McCarthy B., Garcia A., and Ferketich A.K. Multi-detector row cardiac computed tomography accurately quantifies right and left ventricular size and function compared with cardiac magnetic resonance. Am Heart J 151 3 (2006) 736-744
-
(2006)
Am Heart J
, vol.151
, Issue.3
, pp. 736-744
-
-
Raman, S.V.1
Shah, M.2
McCarthy, B.3
Garcia, A.4
Ferketich, A.K.5
-
94
-
-
37549042439
-
Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance
-
Annuar B.R., Liew C.K., Chin S.P., Ong T.K., Seyfarth M.T., Chan W.L., Fong Y.Y., Ang C.K., Lin N., Liew H.B., and Sim K.H. Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: a comparison with cardiac magnetic resonance. Eur J Radiol 65 1 (2008) 112-119
-
(2008)
Eur J Radiol
, vol.65
, Issue.1
, pp. 112-119
-
-
Annuar, B.R.1
Liew, C.K.2
Chin, S.P.3
Ong, T.K.4
Seyfarth, M.T.5
Chan, W.L.6
Fong, Y.Y.7
Ang, C.K.8
Lin, N.9
Liew, H.B.10
Sim, K.H.11
-
95
-
-
16244372049
-
Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation
-
Schlosser T., Pagonidis K., Herborn C.U., Hunold P., Waltering K.U., Lauenstein T.C., and Barkhausen J. Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border delineation. AJR Am J Roentgenol 184 3 (2005) 765-773
-
(2005)
AJR Am J Roentgenol
, vol.184
, Issue.3
, pp. 765-773
-
-
Schlosser, T.1
Pagonidis, K.2
Herborn, C.U.3
Hunold, P.4
Waltering, K.U.5
Lauenstein, T.C.6
Barkhausen, J.7
-
96
-
-
33751517766
-
Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature
-
van der Vleuten P.A., Willems T.P., Gotte M.J., Tio R.A., Greuter M.J., Zijlstra F., and Oudkerk M. Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature. Acta Radiol 47 10 (2006) 1049-1057
-
(2006)
Acta Radiol
, vol.47
, Issue.10
, pp. 1049-1057
-
-
van der Vleuten, P.A.1
Willems, T.P.2
Gotte, M.J.3
Tio, R.A.4
Greuter, M.J.5
Zijlstra, F.6
Oudkerk, M.7
|