메뉴 건너뛰기




Volumn 107, Issue 5-6, 2004, Pages 497-505

Use of saline chaser in the intravenous, administration of contrast material in non-invasive coronary angiography with 16-row multislice computed tomography;Utilizzo della soluzione salina nella somministrazione endovenosa del mezzo di contrasto in coronarografia non invasiva con TC multistrato a 16 detettori

Author keywords

Computed tomography, multislice CT; Contrast material; Coronary angiography, bolus chaser

Indexed keywords

CONTRAST MEDIUM; IODINATED CONTRAST MEDIUM; SODIUM CHLORIDE;

EID: 3142772606     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (27)

References (22)
  • 1
    • 0345601859 scopus 로고    scopus 로고
    • Angiografia coronarica non invasiva con tomografia computerizzata spirale multistrato: Stato dell'arte e prospettive future
    • Cademartiri F, Luccichenti G, Marano R et al: Angiografia coronarica non invasiva con tomografia computerizzata spirale multistrato: stato dell'arte e prospettive future. Radiol Med 106: 269-283, 2003.
    • (2003) Radiol Med , vol.106 , pp. 269-283
    • Cademartiri, F.1    Luccichenti, G.2    Marano, R.3
  • 2
    • 0345169826 scopus 로고    scopus 로고
    • Angio-TC con apparecchiature spirali ad uno, quattro e sedici strati: Nota tecnica
    • Cademartiri F, Luccichenti G, Marano R et al: Angio-TC con apparecchiature spirali ad uno, quattro e sedici strati: Nota tecnica. Radiol Med 106: 284-296, 2003.
    • (2003) Radiol Med , vol.106 , pp. 284-296
    • Cademartiri, F.1    Luccichenti, G.2    Marano, R.3
  • 3
    • 0036325261 scopus 로고    scopus 로고
    • New technical developments in multislice CT - Part 1: Approaching isotropic resolution withsub-millimeter 16-slice scanning
    • Flohr T, Stierstorfer K, Bruder H et al: New technical developments in multislice CT - Part 1: Approaching isotropic resolution withsub-millimeter 16-slice scanning. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174: 839-845, 2002.
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , pp. 839-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3
  • 4
    • 0036373605 scopus 로고    scopus 로고
    • New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
    • Flohr T, Bruder H, Stierstorfer K et al: New Technical Developments in Multislice CT, Part 2: Sub-Millimeter 16-Slice Scanning and Increased Gantry Rotation Speed for Cardiac Imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174: 1022-1027, 2002.
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , pp. 1022-1027
    • Flohr, T.1    Bruder, H.2    Stierstorfer, K.3
  • 5
    • 2242480111 scopus 로고    scopus 로고
    • Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: First experiences
    • Heuschmid M, Kuttner A, Flohr T et al: [Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174: 721-724, 2002.
    • (2002) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.174 , pp. 721-724
    • Heuschmid, M.1    Kuttner, A.2    Flohr, T.3
  • 6
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • Nieman K, Cademartiri F, Lemos PA et al: Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106: 2051-2054, 2002.
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3
  • 7
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • Ropers D, Baum U, Pohle K et al: Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107: 664-666, 2003.
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3
  • 8
    • 0038287868 scopus 로고    scopus 로고
    • Non-invasive demonstration of coronary artery anomaly performed using 16-slice multidetector spiral computed tomography
    • Cademartiri F, Nieman K, Raaymakers RH et al: Non-invasive demonstration of coronary artery anomaly performed using 16-slice multidetector spiral computed tomography. Ital Heart J 4: 56-59, 2003.
    • (2003) Ital Heart J , vol.4 , pp. 56-59
    • Cademartiri, F.1    Nieman, K.2    Raaymakers, R.H.3
  • 10
    • 0029919444 scopus 로고    scopus 로고
    • Dual-phase helical CT of the liver: Effects of bolus tracking and different volumes of contrast material
    • Kopka L, Rodenwaldt J, Fischer U et al: Dual-phase helical CT of the liver: effects of bolus tracking and different volumes of contrast material. Radiology 201: 321-326, 1996.
    • (1996) Radiology , vol.201 , pp. 321-326
    • Kopka, L.1    Rodenwaldt, J.2    Fischer, U.3
  • 11
    • 0034520475 scopus 로고    scopus 로고
    • Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients
    • Kirchner J, Kickuth R, Laufer U et al: Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients. Clin Radiol 55: 368-373, 2000.
    • (2000) Clin Radiol , vol.55 , pp. 368-373
    • Kirchner, J.1    Kickuth, R.2    Laufer, U.3
  • 12
    • 0034888740 scopus 로고    scopus 로고
    • Automatic bolus tracking in monophasic spiral CT of the liver: Liver-tolesion conspicuity
    • Mehnert F, Pereira PL, Trubenbach J et al: Automatic bolus tracking in monophasic spiral CT of the liver: liver-tolesion conspicuity. Eur Radiol 11: 580-584, 2001.
    • (2001) Eur Radiol , vol.11 , pp. 580-584
    • Mehnert, F.1    Pereira, P.L.2    Trubenbach, J.3
  • 13
    • 0034884814 scopus 로고    scopus 로고
    • Biphasic spiral CT of the liver: Automatic bolus tracking or time delay?
    • Mehnert F, Pereira PL, Trubenbach J et al: Biphasic spiral CT of the liver: automatic bolus tracking or time delay? Eur Radiol 11: 427-431, 2001.
    • (2001) Eur Radiol , vol.11 , pp. 427-431
    • Mehnert, F.1    Pereira, P.L.2    Trubenbach, J.3
  • 14
    • 0034885355 scopus 로고    scopus 로고
    • Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT
    • Sandstede JJ, Tschammler A, Beer M et al: Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol 11: 1396-1400, 2001.
    • (2001) Eur Radiol , vol.11 , pp. 1396-1400
    • Sandstede, J.J.1    Tschammler, A.2    Beer, M.3
  • 15
    • 3142722259 scopus 로고    scopus 로고
    • Tecniche per ottimizzare l'opacizzazione coronarica in angiografia non invasiva con TC multistrato a 16 detettori
    • in press
    • Cademartiri F, Luccichenti G, Marano R et al: Tecniche per ottimizzare l'opacizzazione coronarica in angiografia non invasiva con TC multistrato a 16 detettori. Radiol Med (in press).
    • Radiol Med
    • Cademartiri, F.1    Luccichenti, G.2    Marano, R.3
  • 16
    • 0034112337 scopus 로고    scopus 로고
    • Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    • Haage P, Schmitz-Rode T, Hubner D et al: Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol 174: 1049-1053, 2000.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 1049-1053
    • Haage, P.1    Schmitz-Rode, T.2    Hubner, D.3
  • 17
    • 0030825080 scopus 로고    scopus 로고
    • Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    • Hopper KD, Mosher TJ, Kasales CJ, et al: Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology 205: 269-271, 1997.
    • (1997) Radiology , vol.205 , pp. 269-271
    • Hopper, K.D.1    Mosher, T.J.2    Kasales, C.J.3
  • 18
    • 0033858936 scopus 로고    scopus 로고
    • Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver: Assessment of normal values in 25 volunteers
    • Bader TR, Prokesch RW, Grabenwoger F: Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver: assessment of normal values in 25 volunteers. Invest Radiol 35: 486-492, 2000.
    • (2000) Invest Radiol , vol.35 , pp. 486-492
    • Bader, T.R.1    Prokesch, R.W.2    Grabenwoger, F.3
  • 19
    • 0032721730 scopus 로고    scopus 로고
    • Hepatic CT enhancement: Effect of the rate and volume of contrast medium injection in an animal model
    • Garcia P, Genin G, Bret PM et al: Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model. Abdom Imaging 24: 597-603, 1999.
    • (1999) Abdom Imaging , vol.24 , pp. 597-603
    • Garcia, P.1    Genin, G.2    Bret, P.M.3
  • 20
    • 0034466361 scopus 로고    scopus 로고
    • Factors influencing vascular and hepatic enhancement at CT: Experimental study on injection protocol using a canine model
    • Han JK, Kim AY, Lee KY et al: Factors influencing vascular and hepatic enhancement at CT: experimental study on injection protocol using a canine model. J Comput Assist Tomogr 24:400-406, 2000.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 400-406
    • Han, J.K.1    Kim, A.Y.2    Lee, K.Y.3
  • 21
    • 0033848915 scopus 로고    scopus 로고
    • Abdominal helical CT: Evaluation of optimal doses of intravenous contrast material - A prospective randomized study
    • Yamashita Y, Komohara Y, Takahashi M et al: Abdominal helical CT: evaluation of optimal doses of intravenous contrast material-a prospective randomized study. Radiology 216: 718-723, 2000.
    • (2000) Radiology , vol.216 , pp. 718-723
    • Yamashita, Y.1    Komohara, Y.2    Takahashi, M.3
  • 22
    • 0037378558 scopus 로고    scopus 로고
    • Using a saline chaser to decrease contrast media in abdominal CT
    • Dorio PJ, Lee FT Jr, Henseler KP et al: Using a Saline Chaser to Decrease Contrast Media in Abdominal CT. AJR Am J Roentgenol 180: 929- 34, 2003.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 929-934
    • Dorio, P.J.1    Lee Jr., F.T.2    Henseler, K.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.