메뉴 건너뛰기




Volumn 27, Issue 11, 2008, Pages 1611-1621

Fully automated motion correction in first-pass myocardial perfusion MR image sequences

Author keywords

Magnetic resonance imaging (MRI); Myocardial perfusion; Registration

Indexed keywords

ATOMS; FEATURE EXTRACTION; HEMODYNAMICS; IMAGE QUALITY; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; NETWORK PROTOCOLS; RESONANCE; STANDARDS;

EID: 54949100727     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2008.928918     Document Type: Article
Times cited : (77)

References (41)
  • 1
    • 0021132982 scopus 로고
    • Acute myocardial ischemia: Magnetic resonance contrast enhancement with Gadolinium-DTPA
    • M. T. McNamara, C. B. Higgins, R. L. Ehman, D. Revel, R. Sievers, and R. C. Brasch, "Acute myocardial ischemia: Magnetic resonance contrast enhancement with Gadolinium-DTPA," Radiology, vol. 153, pp. 157-163, 1984.
    • (1984) Radiology , vol.153 , pp. 157-163
    • McNamara, M.T.1    Higgins, C.B.2    Ehman, R.L.3    Revel, D.4    Sievers, R.5    Brasch, R.C.6
  • 2
    • 0032755671 scopus 로고    scopus 로고
    • Magnetic resonance first-pass myocardial perfusion imaging: Clinical validation and future applications
    • N. M. Wilke, M. Jerosch-Herold, A. Zenovich, and A. E. Stillman, "Magnetic resonance first-pass myocardial perfusion imaging: Clinical validation and future applications," J. Magn. Reson. Imag., vol. 10, pp. 676-685, 1999.
    • (1999) J. Magn. Reson. Imag , vol.10 , pp. 676-685
    • Wilke, N.M.1    Jerosch-Herold, M.2    Zenovich, A.3    Stillman, A.E.4
  • 3
    • 0035826786 scopus 로고    scopus 로고
    • Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: A comparison with positron emission tomography and coronary angiography
    • J. Schwitter, D. Nanz, S. Kneifel, K. Bertschinger, M. Buchi, P. R. Knusel, B. Marincek, T. F. Luscher, and G. K. v. Schulthess, "Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: A comparison with positron emission tomography and coronary angiography," Circulation, vol. 103, pp. 2230-2235, 2001.
    • (2001) Circulation , vol.103 , pp. 2230-2235
    • Schwitter, J.1    Nanz, D.2    Kneifel, S.3    Bertschinger, K.4    Buchi, M.5    Knusel, P.R.6    Marincek, B.7    Luscher, T.F.8    Schulthess, G.K.V.9
  • 4
    • 0035151744 scopus 로고    scopus 로고
    • Echo-planar magnetic resonance myocardial perfusion imaging: Parametric map analysis and comparison with Thallium SPECT
    • J. R. Panting, P. D. Gatehouse, G. Z. Yang, M. Jerosch-Herold, N. Wilke, D. N. Firmin, and D. J. Pennell, "Echo-planar magnetic resonance myocardial perfusion imaging: Parametric map analysis and comparison with Thallium SPECT," J. Magn. Reson. Imag., vol. 13, pp. 192-200, 2001.
    • (2001) J. Magn. Reson. Imag , vol.13 , pp. 192-200
    • Panting, J.R.1    Gatehouse, P.D.2    Yang, G.Z.3    Jerosch-Herold, M.4    Wilke, N.5    Firmin, D.N.6    Pennell, D.J.7
  • 6
    • 0035193199 scopus 로고    scopus 로고
    • Vergleich verschiedener parameter zur bestimmung eines index der myokardialen perfusionsreserve zur erkennung von koronarstenosen mit kardiovaskulärer magnetresonanztomographie
    • N. Al-Saadi, M. Gross, A. Bornstedt, B. Schnackenburg, C. Klein, E. Fleck, and E. Nagel, "Vergleich verschiedener parameter zur bestimmung eines index der myokardialen perfusionsreserve zur erkennung von koronarstenosen mit kardiovaskulärer magnetresonanztomographie,"Z Kardiol., vol. 90, pp. 824-834, 2001.
    • (2001) Z Kardiol , vol.90 , pp. 824-834
    • Al-Saadi, N.1    Gross, M.2    Bornstedt, A.3    Schnackenburg, B.4    Klein, C.5    Fleck, E.6    Nagel, E.7
  • 7
    • 0041663637 scopus 로고    scopus 로고
    • Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease
    • E. Nagel, C. Klein, I. Paetsch, B. Hettwer, S. Schnackenburg, K. Wegscheider, and E. Fleck, "Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease," Circulation, vol. 18, pp. 432-437, 2003.
    • (2003) Circulation , vol.18 , pp. 432-437
    • Nagel, E.1    Klein, C.2    Paetsch, I.3    Hettwer, B.4    Schnackenburg, S.5    Wegscheider, K.6    Fleck, E.7
  • 8
    • 17644412367 scopus 로고    scopus 로고
    • Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography
    • S. Plein, A. Radjenovic, J. Ridgway, D. Barmby, J. Greenwood, S. Ball, and M. Sivananthan, "Coronary artery disease: Myocardial perfusion MR imaging with sensitivity encoding versus conventional angiography," Radiology, vol. 235, pp. 423-430, 2005.
    • (2005) Radiology , vol.235 , pp. 423-430
    • Plein, S.1    Radjenovic, A.2    Ridgway, J.3    Barmby, D.4    Greenwood, J.5    Ball, S.6    Sivananthan, M.7
  • 9
    • 0034669502 scopus 로고    scopus 로고
    • C. M. Kramer, W. J. R. Jr, S. Mankad, T. M. Theobald, D. L. Pkstis, and Y. L. Hu, Contractile reserve and contrast uptake pattern by magnetic resonance imaging and functional recovery after reperfused myocardial infarction, J. Am. College Cardiol., 36, pp. 1835-1840, 2000.
    • C. M. Kramer, W. J. R. Jr, S. Mankad, T. M. Theobald, D. L. Pkstis, and Y. L. Hu, "Contractile reserve and contrast uptake pattern by magnetic resonance imaging and functional recovery after reperfused myocardial infarction," J. Am. College Cardiol., vol. 36, pp. 1835-1840, 2000.
  • 10
    • 33646032099 scopus 로고    scopus 로고
    • I. Klem, J. F. Heitner, D. J. Shah, M. H. S. Jr, V. Behar, J. Weinsaft, P. Cawley, M. Parker, M. Elliott, R. M. Judd, and R. J. Kim, Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging, J. Am. College Cardiol., 47, pp. 1630-1638, 2006.
    • I. Klem, J. F. Heitner, D. J. Shah, M. H. S. Jr, V. Behar, J. Weinsaft, P. Cawley, M. Parker, M. Elliott, R. M. Judd, and R. J. Kim, "Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging," J. Am. College Cardiol., vol. 47, pp. 1630-1638, 2006.
  • 12
    • 0035077581 scopus 로고    scopus 로고
    • Automated registration of dynamic MR images for the quantification of myocardial perfusion
    • L. M. Bidaut and J. P. Vallee, "Automated registration of dynamic MR images for the quantification of myocardial perfusion "J. Magn. Reson. Imag., vol. 13, pp. 648-655, 2001.
    • (2001) J. Magn. Reson. Imag , vol.13 , pp. 648-655
    • Bidaut, L.M.1    Vallee, J.P.2
  • 14
    • 0041704686 scopus 로고    scopus 로고
    • Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm
    • C. Dornier, M. K. Ivancevic, P. Thevenaz, and J. P. Vallee, "Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm," J. Magn. Reson. Imag., vol. 18, pp. 160-168, 2003.
    • (2003) J. Magn. Reson. Imag , vol.18 , pp. 160-168
    • Dornier, C.1    Ivancevic, M.K.2    Thevenaz, P.3    Vallee, J.P.4
  • 15
    • 0034839755 scopus 로고    scopus 로고
    • Automatic quantitative analysis of cardiac MR perfusion images
    • M. Breeuwer, L. Spreeuwers, and M. Quist, "Automatic quantitative analysis of cardiac MR perfusion images," Proc SPIE Med. Imag., pp. 733-742, 2001.
    • (2001) Proc SPIE Med. Imag , pp. 733-742
    • Breeuwer, M.1    Spreeuwers, L.2    Quist, M.3
  • 16
    • 84974727459 scopus 로고    scopus 로고
    • Integrated image registration for cardiac MR perfusion data
    • R. Bansal and G. Funka-Lea, "Integrated image registration for cardiac MR perfusion data," in Proc. MICCAI, 2002, pp. 659-666.
    • (2002) Proc. MICCAI , pp. 659-666
    • Bansal, R.1    Funka-Lea, G.2
  • 17
    • 12244285689 scopus 로고    scopus 로고
    • Fast method for correcting image misregistration due to organ motion in time-series MRI data
    • S. N. Gupta, M. Solaiyappan, G. M. Beache, A. E. Arai, and T. K. F. Foo, "Fast method for correcting image misregistration due to organ motion in time-series MRI data," Magn. Reson. Med.. vol. 49, pp. 506-514, 2003.
    • (2003) Magn. Reson. Med , vol.49 , pp. 506-514
    • Gupta, S.N.1    Solaiyappan, M.2    Beache, G.M.3    Arai, A.E.4    Foo, T.K.F.5
  • 20
    • 33750474869 scopus 로고    scopus 로고
    • Model-based registration for dynamic cardiac perfusion MRI
    • G. Adluru, E. V. R. DiBella, and M. R. Schabel, "Model-based registration for dynamic cardiac perfusion MRI," Magn. Reson. Med., vol. 24, pp. 1062-1070, 2006.
    • (2006) Magn. Reson. Med , vol.24 , pp. 1062-1070
    • Adluru, G.1    DiBella, E.V.R.2    Schabel, M.R.3
  • 21
    • 84937410940 scopus 로고    scopus 로고
    • Automatic image registration for MR and ultrasound cardiac images
    • C. M. Gallippi and E. T. Gregg, "Automatic image registration for MR and ultrasound cardiac images," in Proc. IPMI, 2001, pp. 148-154.
    • (2001) Proc. IPMI , pp. 148-154
    • Gallippi, C.M.1    Gregg, E.T.2
  • 22
    • 20444449819 scopus 로고    scopus 로고
    • Unsupervised motion-compensation of multi-slice cardiac perfusion MRI
    • M. Stegmann, H. Olafsdottir, and H. Larsson, "Unsupervised motion-compensation of multi-slice cardiac perfusion MRI," Med. Image Anal., vol. 9, pp. 394-410, 2005.
    • (2005) Med. Image Anal , vol.9 , pp. 394-410
    • Stegmann, M.1    Olafsdottir, H.2    Larsson, H.3
  • 23
    • 84886818049 scopus 로고    scopus 로고
    • Motion decoupling and registration for 3D magnetic resonance myocardial perfusion imaging
    • N. A. Ablitt, J. Gao, P. Gatehouse, and G. Z. Yang, "Motion decoupling and registration for 3D magnetic resonance myocardial perfusion imaging," in Proc. ICCS, 2002, pp. 285-294.
    • (2002) Proc. ICCS , pp. 285-294
    • Ablitt, N.A.1    Gao, J.2    Gatehouse, P.3    Yang, G.Z.4
  • 25
    • 0344153792 scopus 로고    scopus 로고
    • Using an adaptive semiautomated self-evaluated registration technique to analyze MRI data for myocardial perfusion assessment
    • T. Delzescaux, F. Frouin, A. D. Cesare, S. Philipp-Foliguet, A. ToddPokropek, A. Herment, and M. Janier, "Using an adaptive semiautomated self-evaluated registration technique to analyze MRI data for myocardial perfusion assessment," J. Magn. Reson. Imag., vol. 18, pp. 681-690, 2003.
    • (2003) J. Magn. Reson. Imag , vol.18 , pp. 681-690
    • Delzescaux, T.1    Frouin, F.2    Cesare, A.D.3    Philipp-Foliguet, S.4    ToddPokropek, A.5    Herment, A.6    Janier, M.7
  • 26
    • 84974695619 scopus 로고    scopus 로고
    • Deformation modeling based on PLSR for cardiac magnetic resonance perfusion imaging
    • J. Gao, N. Ablitt, A. Elkington, and G. Z. Yang, "Deformation modeling based on PLSR for cardiac magnetic resonance perfusion imaging," in Proc. MTCCAI, 2002, pp. 612-619.
    • (2002) Proc. MTCCAI , pp. 612-619
    • Gao, J.1    Ablitt, N.2    Elkington, A.3    Yang, G.Z.4
  • 27
    • 33745176273 scopus 로고    scopus 로고
    • A comparison of FFD-based nonrigid registration and AAMs applied to myocardial perfusion MRI
    • H. Olafsdottir, M. B. Stegmann, B. K. Ersboll, and H. B. W. Larsson, "A comparison of FFD-based nonrigid registration and AAMs applied to myocardial perfusion MRI," Proc. SPIE Med, Imag., pp. 614416-1, 2006.
    • (2006) Proc. SPIE Med, Imag , pp. 614416-614421
    • Olafsdottir, H.1    Stegmann, M.B.2    Ersboll, B.K.3    Larsson, H.B.W.4
  • 28
    • 27644587498 scopus 로고    scopus 로고
    • On the dark RIM artifact in dynamic contrast-enhanced MRI myocardial perfusion studies
    • E. V. R. D. Bella, D. L. Parker, and A. J. Sinusas, "On the dark RIM artifact in dynamic contrast-enhanced MRI myocardial perfusion studies," Magn. Reson. Med., vol. 54, pp. 1295-1299, 2005.
    • (2005) Magn. Reson. Med , vol.54 , pp. 1295-1299
    • Bella, E.V.R.D.1    Parker, D.L.2    Sinusas, A.J.3
  • 29
    • 0032008619 scopus 로고    scopus 로고
    • A survey of medical image registration
    • J. B. A. Maintz and M. A. Viergever, "A survey of medical image registration," Med. Image Anal., vol. 2, pp. 1-36, 1998.
    • (1998) Med. Image Anal , vol.2 , pp. 1-36
    • Maintz, J.B.A.1    Viergever, M.A.2
  • 30
    • 0043028206 scopus 로고    scopus 로고
    • Mutual-information-based registration of medical images: A survey
    • Aug
    • J. P. W. Pluim, J. B. A. Maintz, and M. A. Viergever, "Mutual-information-based registration of medical images: A survey," IEEE Trans. Med. Imag., vol. 22, no. 8, pp. 986-1004, Aug. 2003.
    • (2003) IEEE Trans. Med. Imag , vol.22 , Issue.8 , pp. 986-1004
    • Pluim, J.P.W.1    Maintz, J.B.A.2    Viergever, M.A.3
  • 32
    • 36049040334 scopus 로고    scopus 로고
    • Registration of dynamic contrast-enhanced MRI using a progressive principal component registration (PPCR)
    • A. Melbourne, D. Atkinson, M. White, D. Collins, M. Leach, and D. Hawkes, "Registration of dynamic contrast-enhanced MRI using a progressive principal component registration (PPCR)," Phys. Med. Biol., vol. 52, pp. 5147-5156, 2007.
    • (2007) Phys. Med. Biol , vol.52 , pp. 5147-5156
    • Melbourne, A.1    Atkinson, D.2    White, M.3    Collins, D.4    Leach, M.5    Hawkes, D.6
  • 34
    • 0042826822 scopus 로고    scopus 로고
    • Independent component analysis: Algorithms and applications
    • A. Hyvarinen and E. Oja, "Independent component analysis: Algorithms and applications," Neural Netw., vol. 13, pp. 411-430, 2000.
    • (2000) Neural Netw , vol.13 , pp. 411-430
    • Hyvarinen, A.1    Oja, E.2
  • 35
    • 0036083756 scopus 로고    scopus 로고
    • Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis
    • T. J. Carroll, V. M. Haughton, H. A. Rowley, and D. Cordes, "Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis," Am. J. Neuroradiol., vol. 23, pp. 1007-1012, 2002.
    • (2002) Am. J. Neuroradiol , vol.23 , pp. 1007-1012
    • Carroll, T.J.1    Haughton, V.M.2    Rowley, H.A.3    Cordes, D.4
  • 36
    • 0036150952 scopus 로고    scopus 로고
    • Comparison of independent component analysis and conventional hypothesis-driven analysis for clinical functional MR image processing
    • M. A. Quigley, V. M. Haughton, J. Carew, D. Cordes, C. H. Moritz, and M. E. Meyerand, "Comparison of independent component analysis and conventional hypothesis-driven analysis for clinical functional MR image processing," Am. J. Neuroradiol., vol. 23, pp. 49-58, 2002.
    • (2002) Am. J. Neuroradiol , vol.23 , pp. 49-58
    • Quigley, M.A.1    Haughton, V.M.2    Carew, J.3    Cordes, D.4    Moritz, C.H.5    Meyerand, M.E.6
  • 37
    • 0036840537 scopus 로고    scopus 로고
    • D. E. Bild, D. A. Bluemke, G. L. Burke, R. Detrano, A. V. D. Roux, A. R. Folsom, P. Greenland, D. R. J. Jr, R. Kronmal, K. Liu, J. C. Nelson, D. O'Leary, M. F. Saad, S. Shea, M. Szklo, and R. P. Tracy, Multi-ethnic study of atherosclerosis: Objectives and design, Am. J. Epidemiol., 156, pp. 871-881, 2002.
    • D. E. Bild, D. A. Bluemke, G. L. Burke, R. Detrano, A. V. D. Roux, A. R. Folsom, P. Greenland, D. R. J. Jr, R. Kronmal, K. Liu, J. C. Nelson, D. O'Leary, M. F. Saad, S. Shea, M. Szklo, and R. P. Tracy, "Multi-ethnic study of atherosclerosis: Objectives and design," Am. J. Epidemiol., vol. 156, pp. 871-881, 2002.
  • 39
    • 31644433611 scopus 로고    scopus 로고
    • Coronary risk factors and myocardial perfusion in asymptomatic adults: The multi-ethnic study of atherosclerosis
    • L. Wang, M. Jerosch-Herold, D. R. Jacobs, E. Shahar, and A. R. Folsom, "Coronary risk factors and myocardial perfusion in asymptomatic adults: The multi-ethnic study of atherosclerosis," J. Am. College Cardiol., vol. 47, pp. 565-572, 2006.
    • (2006) J. Am. College Cardiol , vol.47 , pp. 565-572
    • Wang, L.1    Jerosch-Herold, M.2    Jacobs, D.R.3    Shahar, E.4    Folsom, A.R.5
  • 40
    • 0036770501 scopus 로고    scopus 로고
    • A study of the motion and deformation of the heart due to respiration
    • Sep
    • K. McLeish, D. L. G. Hill, D. Atkinson, J. M. Blackall, and R. Razavi, "A study of the motion and deformation of the heart due to respiration," IEEE Trans. Med. Imag., vol. 21, no. 9, pp. 1142-1150, Sep. 2002.
    • (2002) IEEE Trans. Med. Imag , vol.21 , Issue.9 , pp. 1142-1150
    • McLeish, K.1    Hill, D.L.G.2    Atkinson, D.3    Blackall, J.M.4    Razavi, R.5
  • 41
    • 4043151643 scopus 로고    scopus 로고
    • Predicting respiratory motion for four-dimensional radiotherapy
    • S. S. Vedam, P. J. Keall, A. Docef, D. A. Todor, V. R. Kini, and R. Mohan, "Predicting respiratory motion for four-dimensional radiotherapy," Med. Phys., vol. 31, pp. 2274-2283, 2004.
    • (2004) Med. Phys , vol.31 , pp. 2274-2283
    • Vedam, S.S.1    Keall, P.J.2    Docef, A.3    Todor, D.A.4    Kini, V.R.5    Mohan, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.