메뉴 건너뛰기




Volumn 31, Issue 8, 2004, Pages 2274-2283

Predicting respiratory motion for four-dimensional radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE FILTERING; ADAPTIVE FILTERS; BIOMEDICAL SIGNAL PROCESSING; CLUTTER (INFORMATION THEORY); ERRORS; FORECASTING; HOSPITAL DATA PROCESSING; PREDICTIVE ANALYTICS; RADIOTHERAPY; REAL TIME SYSTEMS; RESPIRATORY MECHANICS; RESPONSE TIME (COMPUTER SYSTEMS); TARGET TRACKING; TIME DELAY;

EID: 4043151643     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1771931     Document Type: Article
Times cited : (190)

References (17)
  • 1
    • 0038039003 scopus 로고    scopus 로고
    • A method of calculating a lung clinical target volume DVH for IMRT with intrafractional motion
    • J. H. Kung, P. Zygmanski, N. Choi, and G. T. Chen, "A method of calculating a lung clinical target volume DVH for IMRT with intrafractional motion," Med. Phys. 30(6), 1103-1109 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.6 , pp. 1103-1109
    • Kung, J.H.1    Zygmanski, P.2    Choi, N.3    Chen, G.T.4
  • 2
    • 0031892627 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation
    • C. X. Yu, D. A. Jaffray, and J. W. Wong, "The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation," Phys. Med. Biol. 43, 91-104 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 91-104
    • Yu, C.X.1    Jaffray, D.A.2    Wong, J.W.3
  • 3
    • 0035136220 scopus 로고    scopus 로고
    • Motion adaptive x-ray therapy: A feasibility study
    • P. J. Keall, V. Kini, S. S. Vedam, and R. Mohan, "Motion adaptive x-ray therapy: A feasibility study," Phys. Med. Biol. 46(1), 1-10 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , Issue.1 , pp. 1-10
    • Keall, P.J.1    Kini, V.2    Vedam, S.S.3    Mohan, R.4
  • 4
    • 0038497901 scopus 로고    scopus 로고
    • An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments
    • S. B. Jiang, C. Pope, K. M. Al Jarrah, J. H. Kung, T. Bortfeld, and G. T. Chen, "An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments," Phys. Med. Biol. 48(12), 1773-1784 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , Issue.12 , pp. 1773-1784
    • Jiang, S.B.1    Pope, C.2    Al Jarrah, K.M.3    Kung, J.H.4    Bortfeld, T.5    Chen, G.T.6
  • 6
    • 0038033835 scopus 로고    scopus 로고
    • The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
    • C. S. Chui, E. Yorke, and L. Hong, "The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator," Med. Phys. 30(7), 1736-1746 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.7 , pp. 1736-1746
    • Chui, C.S.1    Yorke, E.2    Hong, L.3
  • 7
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • T. Bortfeld, K. Jokivarsi, M. Goitein, J. Kung, and S. B. Jiang, "Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation," Phys. Med. Biol. 47(13), 2203-2220 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , Issue.13 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 9
    • 0037423954 scopus 로고    scopus 로고
    • Synchronized moving aperture radiation therapy (SMART): Average tumour trajectory for lung patients
    • T. Neicu, H. Shirato, Y. Seppenwoolde, and S. B. Jiang, "Synchronized moving aperture radiation therapy (SMART): Average tumour trajectory for lung patients," Phys. Med. Biol. 48(5), 587-598 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , Issue.5 , pp. 587-598
    • Neicu, T.1    Shirato, H.2    Seppenwoolde, Y.3    Jiang, S.B.4
  • 10
    • 0038530967 scopus 로고    scopus 로고
    • The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
    • L. Papiez, "The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery," Math. Comput. Modell. 37, 735-745 (2003).
    • (2003) Math. Comput. Modell. , vol.37 , pp. 735-745
    • Papiez, L.1
  • 11
    • 0029053404 scopus 로고
    • A singular value decomposition based algorithm for multicomponent exponential fitting of NMR relaxation signals
    • M. Lupu and D. Todor, "A singular value decomposition based algorithm for multicomponent exponential fitting of NMR relaxation signals," Chemom. Intell. Lab. Syst. 29(1), 11-17 (1995).
    • (1995) Chemom. Intell. Lab. Syst. , vol.29 , Issue.1 , pp. 11-17
    • Lupu, M.1    Todor, D.2
  • 15
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    • G. C. Sharp, S. B. Jiang, S. Shimizu, and H. Shirato, "Prediction of respiratory tumour motion for real-time image-guided radiotherapy," Phys. Med. Biol. 49(3), 425-440 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , Issue.3 , pp. 425-440
    • Sharp, G.C.1    Jiang, S.B.2    Shimizu, S.3    Shirato, H.4
  • 16
    • 0037391655 scopus 로고    scopus 로고
    • Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker
    • S. S. Vedam, V. R. Kini, P. J. Keall, V. Ramakrishnan, H. Mostafavi, and R. Mohan, "Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker," Med. Phys. 30(4), 505-513 (2003).
    • (2003) Med. Phys. , vol.30 , Issue.4 , pp. 505-513
    • Vedam, S.S.1    Kini, V.R.2    Keall, P.J.3    Ramakrishnan, V.4    Mostafavi, H.5    Mohan, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.