메뉴 건너뛰기




Volumn 49, Issue 3, 2003, Pages 506-514

Fast method for correcting image misregistration due to organ motion in time-series MRI data

Author keywords

BOLD imaging; Image registration; Motion correction; Perfusion imaging

Indexed keywords

ALIGNMENT; IMAGE REGISTRATION; TIME SERIES;

EID: 12244285689     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10394     Document Type: Article
Times cited : (41)

References (32)
  • 1
    • 0025269066 scopus 로고
    • First-pass cardiac perfusion: Evaluation with ultrafast MR imaging
    • Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990;174:757-762.
    • (1990) Radiology , vol.174 , pp. 757-762
    • Atkinson, D.J.1    Burstein, D.2    Edelman, R.R.3
  • 5
    • 0025184288 scopus 로고
    • The principal axes transformation - A method for image registration
    • Alpert NM, Bradshaw JF, Kennedy D, Correia JA. The principal axes transformation - a method for image registration. J Nucl Med 1990;31:1717-1722.
    • (1990) J Nucl Med , vol.31 , pp. 1717-1722
    • Alpert, N.M.1    Bradshaw, J.F.2    Kennedy, D.3    Correia, J.A.4
  • 6
    • 0021576797 scopus 로고
    • Automated correction of patient motion and gray values prior to subtraction in digitized angiography
    • Venot A, Leclerc V. Automated correction of patient motion and gray values prior to subtraction in digitized angiography. IEEE Trans Med Imag 1984:3:179-186.
    • (1984) IEEE Trans Med Imag , vol.3 , pp. 179-186
    • Venot, A.1    Leclerc, V.2
  • 7
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and re-slicing PET images
    • Woods RP, Cherry SR, Mazziotta JC. Rapid automated algorithm for aligning and re-slicing PET images. J Comput Assist Tomogr 1992;16:620-633.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 8
    • 0025376174 scopus 로고
    • Correlation methods for the centering, rotation, and alignment of functional brain images
    • Junck L, Moen JG, Hutchins GD, Brown MB, Kuhl DE. Correlation methods for the centering, rotation, and alignment of functional brain images. J Nucl Med 1990;31:1220-1226.
    • (1990) J Nucl Med , vol.31 , pp. 1220-1226
    • Junck, L.1    Moen, J.G.2    Hutchins, G.D.3    Brown, M.B.4    Kuhl, D.E.5
  • 9
    • 84925245477 scopus 로고
    • Registration of translated and rotated images using finite Fourier transforms
    • de Castro E, Morandi C. Registration of translated and rotated images using finite Fourier transforms. IEEE Trans PAMI 1987;9:700-703.
    • (1987) IEEE Trans PAMI , vol.9 , pp. 700-703
    • De Castro, E.1    Morandi, C.2
  • 10
    • 0024142634 scopus 로고
    • An automated system for the registration and comparison of photographic images in medicine
    • Venot A, Devaux JY, Herbin M, Lebruchec JF, Dubertret L. An automated system for the registration and comparison of photographic images in medicine. IEEE Trans Med Imag 1988;7:298-303.
    • (1988) IEEE Trans Med Imag , vol.7 , pp. 298-303
    • Venot, A.1    Devaux, J.Y.2    Herbin, M.3    Lebruchec, J.F.4    Dubertret, L.5
  • 11
    • 0025159488 scopus 로고
    • Landmark based correlation of medical images
    • Boesecke R, Bruckner T, Ende G, Landmark based correlation of medical images. Phys Med Biol 1990;35:121-126.
    • (1990) Phys Med Biol , vol.35 , pp. 121-126
    • Boesecke, R.1    Bruckner, T.2    Ende, G.3
  • 13
    • 0035077581 scopus 로고    scopus 로고
    • Automated registration of dynamic MR images for the quantification of myocardial perfusion
    • Bidaut LM, Vallee JP, Automated registration of dynamic MR images for the quantification of myocardial perfusion. J Magn Reson Imag 2001;13:648-655.
    • (2001) J Magn Reson Imag , vol.13 , pp. 648-655
    • Bidaut, L.M.1    Vallee, J.P.2
  • 14
    • 0025939073 scopus 로고
    • Semi-automated ROI analysis in dynamic MR studies. I. Image analysis tools for automated correction of organ displacements
    • Gerig G, Kikinis R, Kuoni W, von Schultess GK, Kubler O. Semi-automated ROI analysis in dynamic MR studies. I. Image analysis tools for automated correction of organ displacements. J Comput Assist Tomogr 1991;15:725-732.
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 725-732
    • Gerig, G.1    Kikinis, R.2    Kuoni, W.3    Von Schultess, G.K.4    Kubler, O.5
  • 15
    • 0028902898 scopus 로고
    • Simultaneous temporal resolution of cardiac and respiratory motion in MR imaging
    • Fredrickson JO, Wegmuller H, Herfkens RJ, Pelc NJ. Simultaneous temporal resolution of cardiac and respiratory motion in MR imaging. Radiology 1995;195:169-175.
    • (1995) Radiology , vol.195 , pp. 169-175
    • Fredrickson, J.O.1    Wegmuller, H.2    Herfkens, R.J.3    Pelc, N.J.4
  • 16
    • 0014565977 scopus 로고
    • Digital registration of multispectral video imagery
    • Anuta PF. Digital registration of multispectral video imagery. Soc Photo-Optic Instrum Eng J 1969;7:168-175.
    • (1969) Soc Photo-Optic Instrum Eng J , vol.7 , pp. 168-175
    • Anuta, P.F.1
  • 17
    • 0023792253 scopus 로고
    • Objective image alignment for 3-dimensional reconstruction of digital autoradiograms
    • Hibbard LS, Hawkins RA. Objective image alignment for 3-dimensional reconstruction of digital autoradiograms. J NeuroSci Meth 1988;26:55-74.
    • (1988) J NeuroSci Meth , vol.26 , pp. 55-74
    • Hibbard, L.S.1    Hawkins, R.A.2
  • 18
    • 0028932392 scopus 로고
    • 3D reconstruction of serial sections in light-microscopy
    • Kvasnicka HM, Thiele J. 3D reconstruction of serial sections in light-microscopy. Pathologe 1995;19:128-137.
    • (1995) Pathologe , vol.19 , pp. 128-137
    • Kvasnicka, H.M.1    Thiele, J.2
  • 19
    • 0031028413 scopus 로고    scopus 로고
    • Automated 3D registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    • Studholme C, Hill DLG, Hawkes DJ. Automated 3D registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. Med Phys 1997;24:25-35.
    • (1997) Med Phys , vol.24 , pp. 25-35
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 21
    • 0031974802 scopus 로고    scopus 로고
    • Fast 3D registration of MR brain images using the projection correlation registration algorithm
    • Didon JP, Langevin F. Fast 3D registration of MR brain images using the projection correlation registration algorithm. Med Biol Eng Comput 1998:36:107-111.
    • (1998) Med Biol Eng Comput , vol.36 , pp. 107-111
    • Didon, J.P.1    Langevin, F.2
  • 22
    • 0016057067 scopus 로고
    • Correlation techniques of image registration
    • Pratt WK. Correlation techniques of image registration. IEEE Trans Aero Elec Sys1974;10:353-358.
    • (1974) IEEE Trans Aero Elec Sys , vol.10 , pp. 353-358
    • Pratt, W.K.1
  • 23
    • 0015300540 scopus 로고
    • A class of algorithms for fast digital image registration
    • Barnea DI, Silverman HF. A class of algorithms for fast digital image registration. IEEE Trans Comput 1972;C-21:179-186.
    • (1972) IEEE Trans Comput , vol.C21 , pp. 179-186
    • Barnea, D.I.1    Silverman, H.F.2
  • 25
    • 84937655864 scopus 로고
    • Visual pattern recognition by moment-invariants
    • Hu MK. Visual pattern recognition by moment-invariants. IRE Trans Inf Theory 1962;Feb:169-187.
    • (1962) IRE Trans Inf Theory , vol.FEB , pp. 169-187
    • Hu, M.K.1
  • 26
    • 51649199666 scopus 로고
    • On how we know universals: The perception of auditory and visual forms
    • Pitts W, McCulloch W, On how we know universals: the perception of auditory and visual forms, Bull Math Biophys 1947;9:127-147.
    • (1947) Bull Math Biophys , vol.9 , pp. 127-147
    • Pitts, W.1    McCulloch, W.2
  • 27
    • 0031899389 scopus 로고    scopus 로고
    • Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    • Ding S, Wolff SD, Epstein FH. Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI. Magn Reson Med 1998;39:514-519.
    • (1998) Magn Reson Med , vol.39 , pp. 514-519
    • Ding, S.1    Wolff, S.D.2    Epstein, F.H.3
  • 28
    • 84864924563 scopus 로고    scopus 로고
    • Predictive registration of cardiac MR perfusion images using geometric invariants
    • Denver
    • Solaiyappan M, Gupta SN. Predictive registration of cardiac MR perfusion images using geometric invariants. In: Proc 8th Annual Meeting ISMRM, Denver, 2000. 1:37.
    • (2000) Proc 8th Annual Meeting ISMRM , vol.1 , pp. 37
    • Solaiyappan, M.1    Gupta, S.N.2
  • 29
    • 12244249434 scopus 로고    scopus 로고
    • Rapid multi-slice renal perfusion MR imaging with simultaneous angiographic screening
    • Honolulu
    • Slavin GS, Gupta SN, Choyke PL, Foo TKF. Rapid multi-slice renal perfusion MR imaging with simultaneous angiographic screening. In: Proc 10th Annual Meeting ISMRM, Honolulu, 2002. p 2370.
    • (2002) Proc 10th Annual Meeting ISMRM , pp. 2370
    • Slavin, G.S.1    Gupta, S.N.2    Choyke, P.L.3    Foo, T.K.F.4
  • 30
    • 0032911911 scopus 로고    scopus 로고
    • Assessment of myocardial response to pharmacological interventions using an improved MR imaging technique to estimate T2values
    • Li DB, Oellerich WF, Beck G, Gropler RJ. Assessment of myocardial response to pharmacological interventions using an improved MR imaging technique to estimate T2values. AJR 1999;172:141-145.
    • (1999) AJR , vol.172 , pp. 141-145
    • Li, D.B.1    Oellerich, W.F.2    Beck, G.3    Gropler, R.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.