-
1
-
-
0021809649
-
ECG-synchronised cardiac MR imaging-Method and evaluation
-
P. Lanzer, C. Barta, E. H. Botvinick, H. U. D. Wiesendanger, G. Modin, and C. B. Higgins, "ECG-synchronised cardiac MR imaging-Method and evaluation," Radiology, vol. 155, pp. 681-686, 1985.
-
(1985)
Radiology
, vol.155
, pp. 681-686
-
-
Lanzer, P.1
Barta, C.2
Botvinick, E.H.3
Wiesendanger, H.U.D.4
Modin, G.5
Higgins, C.B.6
-
2
-
-
0023017677
-
Respiration artifacts in MR imaging: Reduction by breath-holding
-
M. R. Paling and J. R. Brookeman, "Respiration artifacts in MR imaging: Reduction by breath-holding," J. Comput. Assist. Tomogr., vol. 10, pp. 1080-1082, 1986.
-
(1986)
J. Comput. Assist. Tomogr.
, vol.10
, pp. 1080-1082
-
-
Paling, M.R.1
Brookeman, J.R.2
-
3
-
-
0033845492
-
Quantification of left ventricular function with magnetic resonance images acquired in realtime
-
R. M. Setser, S. E. Fischer, and C. E. Lorenz, "Quantification of left ventricular function with magnetic resonance images acquired in realtime," J. Magn. Resort. Imag., vol. 12, pp. 430-438, 2000.
-
(2000)
J. Magn. Resort. Imag.
, vol.12
, pp. 430-438
-
-
Setser, R.M.1
Fischer, S.E.2
Lorenz, C.E.3
-
4
-
-
0031788545
-
Diaphragmatic and cardiac motion during suspended breathing: Preliminary experience and implications for breath-hold MR imaging
-
A. E. Holland, J. W. Goldfarb, and R. R. Edelman, "Diaphragmatic and cardiac motion during suspended breathing: Preliminary experience and implications for breath-hold MR imaging," Radiology, vol. 209, pp. 483-489, 1998.
-
(1998)
Radiology
, vol.209
, pp. 483-489
-
-
Holland, A.E.1
Goldfarb, J.W.2
Edelman, R.R.3
-
5
-
-
0035043395
-
Sensitivity encoded cardiac MRI
-
K. P. Pruessmann, M. Weiger, and P. Boesiger, "Sensitivity encoded cardiac MRI," J. Cardiovasc. Magn. Reson., vol. 3, no. 1, pp. 1-9, 2001.
-
(2001)
J. Cardiovasc. Magn. Reson.
, vol.3
, Issue.1
, pp. 1-9
-
-
Pruessmann, K.P.1
Weiger, M.2
Boesiger, P.3
-
6
-
-
0021677949
-
Magnetic resonance imaging with respiratory gating: Techniques and advantages
-
R. L. Ehman, M. T. McNamara, M. Pallack, H. Hricak, and C. B. Higgins, "Magnetic resonance imaging with respiratory gating: Techniques and advantages," Amer. J. Roentgenol., vol. 143, pp. 1175-1182, 1984.
-
(1984)
Amer. J. Roentgenol.
, vol.143
, pp. 1175-1182
-
-
Ehman, R.L.1
McNamara, M.T.2
Pallack, M.3
Hricak, H.4
Higgins, C.B.5
-
7
-
-
0024453449
-
Adaptive technique for high-definition MR imaging of moving structures
-
R. L. Ehman and J. P. Felmlee, "Adaptive technique for high-definition MR imaging of moving structures," Radiology, vol. 173, pp. 255-263, 1989.
-
(1989)
Radiology
, vol.173
, pp. 255-263
-
-
Ehman, R.L.1
Felmlee, J.P.2
-
8
-
-
0344132016
-
On the performance and accuracy of 2D navigator pulses
-
K. Nehrke, P. Bornert, J. Groen, J. Smink, and J. C. Bock, "On the performance and accuracy of 2D navigator pulses," Magn. Reson. Imag., vol. 17, no. 8, pp. 1173-1181, 1999.
-
(1999)
Magn. Reson. Imag.
, vol.17
, Issue.8
, pp. 1173-1181
-
-
Nehrke, K.1
Bornert, P.2
Groen, J.3
Smink, J.4
Bock, J.C.5
-
9
-
-
0030977431
-
Prospective navigator correction of image position for coronary MR angiography
-
P. G. Danias, M. V. McConnell, V. C. Khasgiwala, M. L. Chuang, R. R. Edelman, and W. J. Manning, "Prospective navigator correction of image position for coronary MR angiography," Radiology, vol. 203, pp. 733-736, 1997.
-
(1997)
Radiology
, vol.203
, pp. 733-736
-
-
Danias, P.G.1
McConnell, M.V.2
Khasgiwala, V.C.3
Chuang, M.L.4
Edelman, R.R.5
Manning, W.J.6
-
10
-
-
0028929929
-
Respiratory motion of the heart: Kinematics and the implications for the spatial resolution in coronary imaging
-
Y. Wang, S. J. Riederer, and R. L. Ehman, "Respiratory motion of the heart: Kinematics and the implications for the spatial resolution in coronary imaging," Magn. Resort. Med., vol. 33, pp. 713-719, 1995.
-
(1995)
Magn. Resort. Med.
, vol.33
, pp. 713-719
-
-
Wang, Y.1
Riederer, S.J.2
Ehman, R.L.3
-
11
-
-
0033624993
-
The real-time interactive 3D-DVA for robust coronary MRA
-
Feb
-
T. Sachs, C. H. Meyer, J. M. Pauly, B. S. Hu, D. G. Nishimura, and A. Macouski, "The real-time interactive 3D-DVA for robust coronary MRA," IEEE Trans. Med. Imag., vol. 19, pp. 73-79, Feb. 2000.
-
(2000)
IEEE Trans. Med. Imag.
, vol.19
, pp. 73-79
-
-
Sachs, T.1
Meyer, C.H.2
Pauly, J.M.3
Hu, B.S.4
Nishimura, D.G.5
Macouski, A.6
-
12
-
-
0036136070
-
Spherical navigator echoes for full 3D rigid body motion measurement in MRI
-
E. B. Welch, A. Manduca, R. C. Grimm, H. Ward, and C. R. Jack, "Spherical navigator echoes for full 3D rigid body motion measurement in MRI," Magn. Reson. Med., vol. 47, pp. 32-41, 2002.
-
(2002)
Magn. Reson. Med.
, vol.47
, pp. 32-41
-
-
Welch, E.B.1
Manduca, A.2
Grimm, R.C.3
Ward, H.4
Jack, C.R.5
-
13
-
-
0013230884
-
A novel navigator technique for fast and direct detection of 3D displacement of the coronary arteries
-
Glasgow, U.K
-
T. D. Nguyen, Y. Wang, and M. R. Prince, "A novel navigator technique for fast and direct detection of 3D displacement of the coronary arteries," in Proc. 9th Annu. Meeting ISMRM, Glasgow, U.K., 2001, no. 173.
-
(2001)
Proc. 9th Annu. Meeting ISMRM
, vol.173
-
-
Nguyen, T.D.1
Wang, Y.2
Prince, M.R.3
-
14
-
-
0030966347
-
Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
-
M. V. McConnell, V. C. Khasgiwala, B. J. Savord, M. H. Chen, M. L. Chuang, R. R. Edelman, and W. J. Manning, "Comparison of respiratory suppression methods and navigator locations for MR coronary angiography," Amer. J. Roentanol., vol. 168, pp. 1369-1375, 1997.
-
(1997)
Amer. J. Roentanol.
, vol.168
, pp. 1369-1375
-
-
McConnell, M.V.1
Khasgiwala, V.C.2
Savord, B.J.3
Chen, M.H.4
Chuang, M.L.5
Edelman, R.R.6
Manning, W.J.7
-
15
-
-
0034874006
-
Free-breathing cardiac MR imaging: Study of implications of respiratory motion-Initial results
-
K. Nehrke, P. Bornert, D. Manke, and J. C. Bock, "Free-breathing cardiac MR imaging: Study of implications of respiratory motion-Initial results," Radiology, vol. 220, pp. 810-815, 2001.
-
(2001)
Radiology
, vol.220
, pp. 810-815
-
-
Nehrke, K.1
Bornert, P.2
Manke, D.3
Bock, J.C.4
-
16
-
-
0036184676
-
Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging
-
J. Keegan, P. D. Gatehouse, G. Z. Yang, and D. N. Firmin, "Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: Implications for slice-followed coronary artery imaging," Magn. Reson. Med., vol. 47, no. 3, pp. 476-481, 2002.
-
(2002)
Magn. Reson. Med.
, vol.47
, Issue.3
, pp. 476-481
-
-
Keegan, J.1
Gatehouse, P.D.2
Yang, G.Z.3
Firmin, D.N.4
-
17
-
-
0003319780
-
Study of respiratory motion in coronary MRA
-
Glasgow, UK
-
D. Manke, K. Nehrke, P. Rosch, P. Bornert, and O. Dossel, "Study of respiratory motion in coronary MRA," in Proc. 9th Annu. Meeting ISMRM, Glasgow, UK, 2001, no. 1852.
-
(2001)
Proc. 9th Annu. Meeting ISMRM
, vol.1852
-
-
Manke, D.1
Nehrke, K.2
Rosch, P.3
Bornert, P.4
Dossel, O.5
-
18
-
-
0033169211
-
Nonrigid registration using free-form deformations: Applications to breast MR images
-
Aug
-
D. Ruekert, L. I. Sonoda, C. Hayes, D. L. G. Hill, M. O. Leach, and D. J. Hawkes, "Nonrigid registration using free-form deformations: Applications to breast MR images," IEEE Trans. Med. Imag., vol. 18, pp. 712-721, Aug. 1999.
-
(1999)
IEEE Trans. Med. Imag.
, vol.18
, pp. 712-721
-
-
Ruekert, D.1
Sonoda, L.I.2
Hayes, C.3
Hill, D.L.G.4
Leach, M.O.5
Hawkes, D.J.6
-
20
-
-
0033624992
-
Voxel similarity measures for 3D serial MR brain image registration
-
Feb
-
M. Holden, D. L. G. Hill, E. R. E. Denton, J. M. Jarosz, T. C. S. Cox, T. Rohlfing, J. Goodey, and D. J. Hawkes, "Voxel similarity measures for 3D serial MR brain image registration," IEEE Trans. Med. Imag., vol. 19, pp. 92-102, Feb. 2000.
-
(2000)
IEEE Trans. Med. Imag.
, vol.19
, pp. 92-102
-
-
Holden, M.1
Hill, D.L.G.2
Denton, E.R.E.3
Jarosz, J.M.4
Cox, T.C.S.5
Rohlfing, T.6
Goodey, J.7
Hawkes, D.J.8
-
21
-
-
84947426247
-
Consistent linear-elastic transformations for image matching
-
A. Kuba and M. Samal, Eds. Berlin, Germany: Springer-Verlag, Lecture Notes in Computer Science
-
G. E. Christensen, "Consistent linear-elastic transformations for image matching," in Information Processing in Medical Imaging, A. Kuba and M. Samal, Eds. Berlin, Germany: Springer-Verlag, 1999, Lecture Notes in Computer Science, pp. 224-237.
-
(1999)
Information Processing in Medical Imaging
, pp. 224-237
-
-
Christensen, G.E.1
-
22
-
-
0029802526
-
Accurate registration of serial 3D MR brain images and its application to visualizing change in neurodegenerative disorders
-
P. A. Freeborough, R. P. Woods, and N. C. Fox, "Accurate registration of serial 3D MR brain images and its application to visualizing change in neurodegenerative disorders," J. Comput. Assist. Tomogr., vol. 20, no. 2, pp. 1012-1022, 1996.
-
(1996)
J. Comput. Assist. Tomogr.
, vol.20
, Issue.2
, pp. 1012-1022
-
-
Freeborough, P.A.1
Woods, R.P.2
Fox, N.C.3
-
23
-
-
0031910991
-
Automated image registration: 1. General methods and intrasubject, intramodality validation
-
R. P. Woods, S. T. Grafton, C. J. Holmes, S. R. Cherry, and J. C. Mazziotta, "Automated image registration: 1. General methods and intrasubject, intramodality validation," J. Comput. Assist. Tomogr., vol. 22, no. 1, pp. 139-152, 1998.
-
(1998)
J. Comput. Assist. Tomogr.
, vol.22
, Issue.1
, pp. 139-152
-
-
Woods, R.P.1
Grafton, S.T.2
Holmes, C.J.3
Cherry, S.R.4
Mazziotta, J.C.5
-
24
-
-
84991505464
-
Detecting failure, assessing success
-
J. Hajnal, D. J. Hawkes, and D. L. G. Hill, Eds. Boca Raton, FL: CRC Press
-
J. M. Fitzpatrick, "Detecting failure, assessing success," in Medical Image Registration, 1st ed, J. Hajnal, D. J. Hawkes, and D. L. G. Hill, Eds. Boca Raton, FL: CRC Press, 2001, pp. 117-139.
-
(2001)
Medical Image Registration, 1st Ed
, pp. 117-139
-
-
Fitzpatrick, J.M.1
-
25
-
-
0029182228
-
Active shape models-Their training and application
-
T. F. Cootes, C. J. Taylor, and D. H. Cooper, "Active shape models-Their training and application," Comput. Vis. Image Understand., vol. 61, no. 1, pp. 38-59, 1995.
-
(1995)
Comput. Vis. Image Understand.
, vol.61
, Issue.1
, pp. 38-59
-
-
Cootes, T.F.1
Taylor, C.J.2
Cooper, D.H.3
-
26
-
-
0023381475
-
Marching cubes: A high resolution 3D surface reconstruction algorithm
-
W. E. Lorensen and H. E. Cline, "Marching cubes: A high resolution 3D surface reconstruction algorithm," Comp. Graph., vol. 21, no. 4, pp. 163-169, 1987.
-
(1987)
Comp. Graph.
, vol.21
, Issue.4
, pp. 163-169
-
-
Lorensen, W.E.1
Cline, H.E.2
-
27
-
-
79960708807
-
Automatic 3D ASM construction via atlas-based landmarking and volumetric elastic registration
-
M. F. Insana and R. M. Leahy, Eds. Berlin, Germany: Springer-Verlag, Lecture Notes in Computer Science
-
A. F. Frangi, D. Ruekert, J. A. Schnabel, and W. J. Niessen, "Automatic 3D ASM construction via atlas-based landmarking and volumetric elastic registration," in Information Processing in Medical Imaging, M. F. Insana and R. M. Leahy, Eds. Berlin, Germany: Springer-Verlag, 2001, Lecture Notes in Computer Science, pp. 78-91.
-
(2001)
Information Processing in Medical Imaging
, pp. 78-91
-
-
Frangi, A.F.1
Ruekert, D.2
Schnabel, J.A.3
Niessen, W.J.4
-
28
-
-
84958152874
-
A statistical model of respiratory motion and deformation of the liver
-
W. J. Niessen and M. A. Viergever, Eds., Berlin, Germany
-
J. M. Blackall, A. P. King, G. P. Penney, A. Adam, and D. J. Hawkes, "A statistical model of respiratory motion and deformation of the liver," in Proc. Medical Image Computing and Computer-Assisted Intervention (MICCAI 2001), W. J. Niessen and M. A. Viergever, Eds., Berlin, Germany, 2001, pp. 1338-1340.
-
(2001)
Proc. Medical Image Computing and Computer-Assisted Intervention (MICCAI 2001)
, pp. 1338-1340
-
-
Blackall, J.M.1
King, A.P.2
Penney, G.P.3
Adam, A.4
Hawkes, D.J.5
-
29
-
-
0031283439
-
Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
-
Dec
-
D. Atkinson, D. L. G. Hill, P. N. R. Stoyle, P. E. Summers, and S. F. Keevil, "Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion," IEEE Trans. Med. Imag., vol. 16, pp. 903-910, Dec. 1997.
-
(1997)
IEEE Trans. Med. Imag.
, vol.16
, pp. 903-910
-
-
Atkinson, D.1
Hill, D.L.G.2
Stoyle, P.N.R.3
Summers, P.E.4
Keevil, S.F.5
-
30
-
-
0027729937
-
Respiration-synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans
-
K. Toska and M. Eriksen, "Respiration-synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans," J. Physiol., vol. 472, pp, 501-512, 1993.
-
(1993)
J. Physiol.
, vol.472
, pp. 501-512
-
-
Toska, K.1
Eriksen, M.2
-
31
-
-
0031195394
-
Registration of head volume images using implantable fiducial markers
-
Aug
-
C. R. Maurer, J. M. Fitzpatrick, M. Y. Wang, R. L. Galloway, R. J. Maciunas, and G. S. Allen, "Registration of head volume images using implantable fiducial markers," IEEE Trans. Med. Imag., vol. 16, pp. 447-462, Aug. 1997.
-
(1997)
IEEE Trans. Med. Imag.
, vol.16
, pp. 447-462
-
-
Maurer, C.R.1
Fitzpatrick, J.M.2
Wang, M.Y.3
Galloway, R.L.4
Maciunas, R.J.5
Allen, G.S.6
-
32
-
-
84937392349
-
Validation of nonrigid registration using finite element methods
-
M. F. Insana and R. M. Leahy, Eds. Berlin, Germany: Springer-Verlag, Lecture Notes in Computer Science
-
J. A. Schnabel, C. Tanner, A. C. Smith, M. O. Leach, C. Hayes, A. Degenhard, R. Hose, D. L. G. Hill, and D. J. Hawkes, "Validation of nonrigid registration using finite element methods," in Information Processing in Medical Imaging, M. F. Insana and R. M. Leahy, Eds. Berlin, Germany: Springer-Verlag, 2001, Lecture Notes in Computer Science, pp. 344-357.
-
(2001)
Information Processing in Medical Imaging
, pp. 344-357
-
-
Schnabel, J.A.1
Tanner, C.2
Smith, A.C.3
Leach, M.O.4
Hayes, C.5
Degenhard, A.6
Hose, R.7
Hill, D.L.G.8
Hawkes, D.J.9
-
33
-
-
0032941481
-
A method for incorporating organ motion due to breathing into dose calculations
-
A. E. Lujan, E. W. Larsen, J. M. Balter, and R. K. T. Haken, "A method for incorporating organ motion due to breathing into dose calculations," Med. Phys., vol. 26, no. 5, pp. 715-720, 1999.
-
(1999)
Med. Phys.
, vol.26
, Issue.5
, pp. 715-720
-
-
Lujan, A.E.1
Larsen, E.W.2
Balter, J.M.3
Haken, R.K.T.4
|