메뉴 건너뛰기




Volumn 222, Issue 5, 2008, Pages 583-592

Femoral stem wear in cemented total hip replacement

Author keywords

Bone cement; Femoral stem; Simulation; Total hip replacement; Wear

Indexed keywords

ASEPTIC LOOSENING; BONE RESORPTION; CORROSION PRODUCTS; FEMORAL STEM; FEMORAL STEMS; IN-VITRO; IN-VIVO; INITIATION AND PROPAGATION; LOAD-BEARING; NEW MATERIAL; OSTEONECROSIS; REDUCING WEAR; SIMULATION; STEM-CEMENT INTERFACES; TOTAL HIP REPLACEMENT; TOTAL HIP REPLACEMENTS; WEAR; WEAR DEBRIS; WEAR-TESTING; TOTAL HIP REPLACEMENT (THR);

EID: 54749113188     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM346     Document Type: Review
Times cited : (46)

References (60)
  • 1
    • 72849167386 scopus 로고
    • Anchorage of femoral head prosthesis to shaft of femur
    • Charnley, J. Anchorage of femoral head prosthesis to shaft of femur. J. Bone Jt Surg. Br., 1960, 42, 28-30.
    • (1960) J. Bone Jt Surg. Br , vol.42 , pp. 28-30
    • Charnley, J.1
  • 2
    • 8144224048 scopus 로고    scopus 로고
    • Acrylic bone cement in the new millennium - clinical development and current status: Europe
    • Wirz, D., Daniels, A. U., Göpfert, B., and Morscher, E. W. Acrylic bone cement in the new millennium - clinical development and current status: Europe. Orthop. Clin. N. Am., 2005, 36, 63-73.
    • (2005) Orthop. Clin. N. Am , vol.36 , pp. 63-73
    • Wirz, D.1    Daniels, A.U.2    Göpfert, B.3    Morscher, E.W.4
  • 3
    • 1642402000 scopus 로고    scopus 로고
    • Quantitative measurement of the stresses induced during polymerisation of bone cement
    • Roques, A., Browne, M., Taylor, A., New, A., and Baker, D. Quantitative measurement of the stresses induced during polymerisation of bone cement. Biomaterials, 2004, 25, 4415-4424.
    • (2004) Biomaterials , vol.25 , pp. 4415-4424
    • Roques, A.1    Browne, M.2    Taylor, A.3    New, A.4    Baker, D.5
  • 5
    • 0036908878 scopus 로고    scopus 로고
    • Analysis of long term cemented total hip arthro-plasty retrievals
    • Maloney, W. J., Schmalzried, T., and Harris, W. H. Analysis of long term cemented total hip arthro-plasty retrievals. Clin. Orthop. Related Res., 2002, 405, 70-78.
    • (2002) Clin. Orthop. Related Res , vol.405 , pp. 70-78
    • Maloney, W.J.1    Schmalzried, T.2    Harris, W.H.3
  • 6
    • 0031214940 scopus 로고    scopus 로고
    • The effects of cement-stem debonding in THA on the long term failure probability of cement
    • Verdonschot, N. and Huiskes, R. The effects of cement-stem debonding in THA on the long term failure probability of cement. J. Biomechanics, 1997, 30, 795-802.
    • (1997) J. Biomechanics , vol.30 , pp. 795-802
    • Verdonschot, N.1    Huiskes, R.2
  • 7
    • 38749098213 scopus 로고    scopus 로고
    • Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement
    • Mohler, C. G., Callaghan, J. J., Collis, D. K., and Johnston, R. C. Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. J. Bone Jt Surg. Br., 1996, 78, 280-285.
    • (1996) J. Bone Jt Surg. Br , vol.78 , pp. 280-285
    • Mohler, C.G.1    Callaghan, J.J.2    Collis, D.K.3    Johnston, R.C.4
  • 8
    • 0033749234 scopus 로고    scopus 로고
    • The significance of stem-cement loosening of grit-blasted femoral components
    • Schmalzried, T. P., Zahiri, C. A., and Woolson, S. T. The significance of stem-cement loosening of grit-blasted femoral components. Orthopedics, 2000, 23, 1157-1164.
    • (2000) Orthopedics , vol.23 , pp. 1157-1164
    • Schmalzried, T.P.1    Zahiri, C.A.2    Woolson, S.T.3
  • 11
    • 0031733691 scopus 로고    scopus 로고
    • Migration, stem shape, and surface finish in cemented total hip arthroplasty
    • Huiskes, R., Verdonschot, N., and Nivbrant, B. Migration, stem shape, and surface finish in cemented total hip arthroplasty. Clin. Orthop. Related Res., 1998, 355, 103-112.
    • (1998) Clin. Orthop. Related Res , vol.355 , pp. 103-112
    • Huiskes, R.1    Verdonschot, N.2    Nivbrant, B.3
  • 12
    • 38749143769 scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene
    • Wroblewski, B. M., Siney, P. D., Dowson, D., and Collins, S. N. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene. J. Bone Jt Surg. Am., 1995, 77, 1315-1322.
    • (1995) J. Bone Jt Surg. Am , vol.77 , pp. 1315-1322
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 13
    • 0035989711 scopus 로고    scopus 로고
    • Alumina-alumina artificial hip joints: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision
    • Hatton, A., Nevelos, J. E., Nevelos, A. A., Banks, R. E., Fisher, J., and Ingham, E. Alumina-alumina artificial hip joints: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials, 2002, 23, 3429-3440.
    • (2002) Biomaterials , vol.23 , pp. 3429-3440
    • Hatton, A.1    Nevelos, J.E.2    Nevelos, A.A.3    Banks, R.E.4    Fisher, J.5    Ingham, E.6
  • 15
    • 4844231766 scopus 로고    scopus 로고
    • Assessment of wear on the cones of modular stainless steel Exeter hip stems
    • Chaplin, R. P. S., Lee, A. J. C., and Hooper, R. M. Assessment of wear on the cones of modular stainless steel Exeter hip stems. J. Mater. Sci., Mater. Medicine, 2004, 15, 977-990.
    • (2004) J. Mater. Sci., Mater. Medicine , vol.15 , pp. 977-990
    • Chaplin, R.P.S.1    Lee, A.J.C.2    Hooper, R.M.3
  • 17
    • 0016251286 scopus 로고
    • Reaction of bone to methacrylate after hip arthro-plasty: A long term gross, light microscopic and scanning electron microscopic study
    • Willert, H. G., Ludwig, J., and Semlitsch, M. Reaction of bone to methacrylate after hip arthro-plasty: a long term gross, light microscopic and scanning electron microscopic study. J. Bone Jt Surg. Am., 1974, 56, 1368-1382.
    • (1974) J. Bone Jt Surg. Am , vol.56 , pp. 1368-1382
    • Willert, H.G.1    Ludwig, J.2    Semlitsch, M.3
  • 18
    • 0020642078 scopus 로고
    • The incidence and significance of rub marks on the stem of removed total hip replacements
    • Dobbs, H. S. and Robertson, J. L. The incidence and significance of rub marks on the stem of removed total hip replacements. J. Biomed Mater. Res., 1983, 17, 83-89.
    • (1983) J. Biomed Mater. Res , vol.17 , pp. 83-89
    • Dobbs, H.S.1    Robertson, J.L.2
  • 19
    • 0025047558 scopus 로고
    • Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties
    • Anthony, P. P., Gie, G. A., Howie, C. R., and Ling, R. S. M. Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J. Bone Jt Surg. Br., 1990, 72, 971- 979.
    • (1990) J. Bone Jt Surg. Br , vol.72 , pp. 971-979
    • Anthony, P.P.1    Gie, G.A.2    Howie, C.R.3    Ling, R.S.M.4
  • 20
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • Witt, J. D. and Swann, M. Metal wear and tissue response in failed titanium alloy total hip replacements. J. Bone Jt Surg., 1991, 73, 559-563.
    • (1991) J. Bone Jt Surg , vol.73 , pp. 559-563
    • Witt, J.D.1    Swann, M.2
  • 21
    • 0026641070 scopus 로고
    • Titanium wear debris in failed cemented total hip arthroplasty: An analysis of 71 cases
    • Buly, R. L., Huo, M. H., Salvati, E., Brien, W., and Bansal, M. Titanium wear debris in failed cemented total hip arthroplasty: an analysis of 71 cases. J. Arthroplasty, 1992, 7, 315-323.
    • (1992) J. Arthroplasty , vol.7 , pp. 315-323
    • Buly, R.L.1    Huo, M.H.2    Salvati, E.3    Brien, W.4    Bansal, M.5
  • 22
    • 0027296132 scopus 로고
    • Particulate metallic debris in cemented total hip arthroplasty
    • Salvati, E. A., Betts, F., and Doty, S. B. Particulate metallic debris in cemented total hip arthroplasty. Clin. Orthop. Related Res., 1993, 293, 160-173.
    • (1993) Clin. Orthop. Related Res , vol.293 , pp. 160-173
    • Salvati, E.A.1    Betts, F.2    Doty, S.B.3
  • 25
    • 1642477264 scopus 로고    scopus 로고
    • An analysis of fretting damage seen on explanted femoral stems
    • Howell, J. R., Blunt, L. A., and Ling, R. S. M. An analysis of fretting damage seen on explanted femoral stems. J. Bone Jt Surg. Br., 1999, 81(Suppl. 2), 163.
    • (1999) J. Bone Jt Surg. Br , vol.81 , Issue.SUPPL. 2 , pp. 163
    • Howell, J.R.1    Blunt, L.A.2    Ling, R.S.M.3
  • 26
    • 0036528664 scopus 로고    scopus 로고
    • Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry
    • Collis, D. K. and Mohler, C. G. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J. Bone Jt Surg. Am., 2002, 84, 586-592.
    • (2002) J. Bone Jt Surg. Am , vol.84 , pp. 586-592
    • Collis, D.K.1    Mohler, C.G.2
  • 27
    • 67649465936 scopus 로고    scopus 로고
    • Polished versus matte cemented femoral stems: A minimum 10-year follow-up study
    • Lefevre, N., Moussa, H., Kerboull, L., Kerboull, M., and Courpied, J. P. Polished versus matte cemented femoral stems: a minimum 10-year follow-up study. J. Bone Jt Surg. Br., 2004, 86(Suppl. 3), 250.
    • (2004) J. Bone Jt Surg. Br , vol.86 , Issue.SUPPL. 3 , pp. 250
    • Lefevre, N.1    Moussa, H.2    Kerboull, L.3    Kerboull, M.4    Courpied, J.P.5
  • 28
    • 85119385398 scopus 로고    scopus 로고
    • Della Valle, A. G., Zoppi, A., Peterson, M. G., and Salvati, E. A. A rough surface finish adversely affects the survivorship of a cemented femoral stem. Clin. Orthop. Related Res., 2005, 436, 158-163.
    • Della Valle, A. G., Zoppi, A., Peterson, M. G., and Salvati, E. A. A rough surface finish adversely affects the survivorship of a cemented femoral stem. Clin. Orthop. Related Res., 2005, 436, 158-163.
  • 29
    • 1642580585 scopus 로고    scopus 로고
    • In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: The influence of wear mechanism on clinical outcome
    • Howell, J. R., Blunt, L. A., Doyle, D., Hooper, R. M., Lee, A. J. C., and Ling, R. S. M. In vivo surface wear mechanisms of femoral components of cemented total hip arthroplasties: the influence of wear mechanism on clinical outcome. J. Arthro-plasty, 2004, 19, 88-101.
    • (2004) J. Arthro-plasty , vol.19 , pp. 88-101
    • Howell, J.R.1    Blunt, L.A.2    Doyle, D.3    Hooper, R.M.4    Lee, A.J.C.5    Ling, R.S.M.6
  • 30
    • 12344321390 scopus 로고    scopus 로고
    • Analysis of 16 retrieved proxi-mally cemented femoral stems
    • Jones, R. E., Willie, B. M., Hayes, H., and Bloebaum, R. D. Analysis of 16 retrieved proxi-mally cemented femoral stems. J. Arthroplasty, 2005, 20, 84-93.
    • (2005) J. Arthroplasty , vol.20 , pp. 84-93
    • Jones, R.E.1    Willie, B.M.2    Hayes, H.3    Bloebaum, R.D.4
  • 33
    • 0032945469 scopus 로고    scopus 로고
    • Current concepts review: Wear in total hip and knee replacements
    • Schmalzried, T. P. and Callaghan, J. J. Current concepts review: wear in total hip and knee replacements. J. Bone Jt Surg. Am., 1999, 81, 115-136.
    • (1999) J. Bone Jt Surg. Am , vol.81 , pp. 115-136
    • Schmalzried, T.P.1    Callaghan, J.J.2
  • 34
    • 0033861254 scopus 로고    scopus 로고
    • Long term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases
    • Herberts, P. and Malchau, H. Long term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop. Scand., 2000, 71, 111-121.
    • (2000) Acta Orthop. Scand , vol.71 , pp. 111-121
    • Herberts, P.1    Malchau, H.2
  • 35
    • 0026098873 scopus 로고
    • Wear debris in cemented total hip arthroplasty
    • Huo, M. H., Salvati, E. A., and Buly, R. L. Wear debris in cemented total hip arthroplasty. Orthopedics, 1991, 14, 335-340.
    • (1991) Orthopedics , vol.14 , pp. 335-340
    • Huo, M.H.1    Salvati, E.A.2    Buly, R.L.3
  • 36
    • 0026577202 scopus 로고
    • Metallic debris in femoral endosteolysis in failed cemented total hip arthro-plasties
    • Huo, M. H., Salvati, E. A., Lieberman, J. R., Betts, F., and Bansal, M. Metallic debris in femoral endosteolysis in failed cemented total hip arthro-plasties. Clin. Orthop. Related Res., 1992, 276, 157-168.
    • (1992) Clin. Orthop. Related Res , vol.276 , pp. 157-168
    • Huo, M.H.1    Salvati, E.A.2    Lieberman, J.R.3    Betts, F.4    Bansal, M.5
  • 37
    • 0027670415 scopus 로고
    • Clinical reviews: Particulate debris and failure of total hip replacement
    • Jasty, M. Clinical reviews: particulate debris and failure of total hip replacement. J. Appl Biomater, 1993, 4, 273-276.
    • (1993) J. Appl Biomater , vol.4 , pp. 273-276
    • Jasty, M.1
  • 43
    • 0041527161 scopus 로고    scopus 로고
    • Cement particles containing radio-opa-cifiers stimulate pro-osteolytic cytokine production from a human monocytic cell line
    • Shardlow, D. L., Stone, M. H., Ingham, E., and Fisher, J. Cement particles containing radio-opa-cifiers stimulate pro-osteolytic cytokine production from a human monocytic cell line. J. Bone Jt Surg. Br., 2003, 85, 900-905.
    • (2003) J. Bone Jt Surg. Br , vol.85 , pp. 900-905
    • Shardlow, D.L.1    Stone, M.H.2    Ingham, E.3    Fisher, J.4
  • 44
    • 0031915540 scopus 로고    scopus 로고
    • Current concepts review: Corrosion of metal orthopaedic implants
    • Jacobs, J. J., Gilbert, J. L., and Urban, R. M. Current concepts review: corrosion of metal orthopaedic implants. J. Bone Jt Surg. Am., 1998, 80, 268-282.
    • (1998) J. Bone Jt Surg. Am , vol.80 , pp. 268-282
    • Jacobs, J.J.1    Gilbert, J.L.2    Urban, R.M.3
  • 47
    • 0027897650 scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: The effect of crevice, stress, motion, and alloy coupling
    • Gilbert, J. L., Buckley, C. A., and Jacobs, J. J. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: the effect of crevice, stress, motion, and alloy coupling. J. Biomed. Mater. Res., 1993, 27, 1533- 1544.
    • (1993) J. Biomed. Mater. Res , vol.27 , pp. 1533-1544
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 48
    • 0028063951 scopus 로고
    • Corrosion and wear at the modular interface of uncemented femoral stems
    • Cook, S. D., Barrack, R. L., and Clemow, A. J. T. Corrosion and wear at the modular interface of uncemented femoral stems. J. Bone Jt Surg. Br., 1994, 76, 68-72.
    • (1994) J. Bone Jt Surg. Br , vol.76 , pp. 68-72
    • Cook, S.D.1    Barrack, R.L.2    Clemow, A.J.T.3
  • 50
    • 0031864958 scopus 로고    scopus 로고
    • In vivo corrosion of 316L stainless steel hip implants: Morphology and elemental compositions of corrosion products
    • Walczak, J., Shahgaldi, F., and Heatley, F. In vivo corrosion of 316L stainless steel hip implants: morphology and elemental compositions of corrosion products. Biomaterials, 1998, 19, 229-237.
    • (1998) Biomaterials , vol.19 , pp. 229-237
    • Walczak, J.1    Shahgaldi, F.2    Heatley, F.3
  • 51
    • 4544287329 scopus 로고    scopus 로고
    • Corrosion of cemented titanium femoral stems
    • Thomas, S. R., Shukla, D., and Latham, P. D. Corrosion of cemented titanium femoral stems. J. Bone Jt Surg. Br., 2004, 86, 974-978.
    • (2004) J. Bone Jt Surg. Br , vol.86 , pp. 974-978
    • Thomas, S.R.1    Shukla, D.2    Latham, P.D.3
  • 52
    • 67649461749 scopus 로고    scopus 로고
    • Comparison of wear and damage caused by bone cements with barium sulphate and zirconia radiopaque additives
    • Fisher, J., Ingham, E., and Stone, M. Comparison of wear and damage caused by bone cements with barium sulphate and zirconia radiopaque additives. J. Bone Jt Surg. Br., 1997, 79(Suppl. 2), O586.
    • (1997) J. Bone Jt Surg. Br , vol.79 , Issue.SUPPL. 2
    • Fisher, J.1    Ingham, E.2    Stone, M.3
  • 54
    • 19944372088 scopus 로고    scopus 로고
    • Fretting corrosion of materials used as orthopaedic implants
    • Geringer, J., Forest, B., and Combrade, P. Fretting corrosion of materials used as orthopaedic implants. Wear, 2005, 259, 943-951.
    • (2005) Wear , vol.259 , pp. 943-951
    • Geringer, J.1    Forest, B.2    Combrade, P.3
  • 56
    • 0141792462 scopus 로고    scopus 로고
    • Comparative in vitro study on the long term performance of cemented hip stems: Validation of a protocol to discriminate between good and bad designs
    • Cristofolini, L., Teutonico, A. S., Monti, L., Cappello, A., and Toni, A. Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between good and bad designs. J. Biomechanics, 2003, 36, 1603-1615.
    • (2003) J. Biomechanics , vol.36 , pp. 1603-1615
    • Cristofolini, L.1    Teutonico, A.S.2    Monti, L.3    Cappello, A.4    Toni, A.5
  • 57
  • 59
    • 67649504056 scopus 로고    scopus 로고
    • Use of 3D analysis to investigate the surface replication of PMMA bone cement on stainless steel femoral stems. In the National Measurement Conference, Harrogate, UK
    • 6-8 November
    • Brown, L., Blunt, L., and Howell, J. Use of 3D analysis to investigate the surface replication of PMMA bone cement on stainless steel femoral stems. In the National Measurement Conference, Harrogate, UK, 6-8 November 2001, poster presentation.
    • (2001) poster presentation
    • Brown, L.1    Blunt, L.2    Howell, J.3
  • 60
    • 67649504054 scopus 로고    scopus 로고
    • Understanding initiation and propagation of fretting wear on the femoral stem in total hip replacement
    • In the, Huddersfield, UK, 17-20 July
    • Zhang, H., Brown, L., and Blunt, L. Understanding initiation and propagation of fretting wear on the femoral stem in total hip replacement. In the 11th International Conference on Metrology and Properties of Engineering Surfaces, Huddersfield, UK, 17-20 July 2007, pp. 119-123.
    • (2007) 11th International Conference on Metrology and Properties of Engineering Surfaces , pp. 119-123
    • Zhang, H.1    Brown, L.2    Blunt, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.